PLUMBING - GENERAL NOTES <br />1.THESE PLANS ARE INTENDED FOR DIAGRAMMATIC DISPLAY. SHOWING THE GENERAL <br />LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE <br />SCALED FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL DRAWINGS FOR <br />DIMENSIONS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR <br />EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. PROVIDE PIPING, <br />CONNECTIONS, FITTINGS, VALVES, OFFSETS AND ALL MATERIALS NECESSARY FOR A <br />COMPLETE SYSTEM. SUBMIT SHOP DRAWINGS WHEN SPECIFIED. <br />2.EXACT LOCATION OF PLUMBING FIXTURES SHALL BE DETERMINED FROM ARCH DESIGN <br />AND COORDINATED IN FIELD. <br />3.ALL BURIED SANITARY SHALL HAVE A MINIMUM SLOPE OF 2% FOR LESS THAN 2.5" INCH <br />SIZE AND A MINIMUM SLOPE OF 1% FOR 3-6 INCH SIZE. <br />4.ALL FLOOR CLEANOUTS SHALL HAVE ROUND POLISHED BRONZE TOP COVERS WITH <br />BRASS CLEAN-OUT PLUG. COVERS SHALL BE SET SO THAT THEY ARE FLUSH WITH <br />SURROUNDING FLOOR SURFACES. COVERS SHALL BE SECURED WITH STANDARD <br />SCREWS. SEE SCHEDULE. <br />5.ALL FLOOR DRAINS SHALL BE 3" PIPE SIZE UNLESS NOTED OTHERWISE. ALL DRAIN <br />COVERS SHALL BE SECURED WITH STANDARD SCREWS. PVC NOT ALLOWED FOR THE <br />FIRST 8'. <br />6.ALL PIPING IN FINISHED AREAS SHALL BE CONCEALED. <br />7.ALL VENT PIPING SHALL PITCH TO DRAIN. <br />8.REFER TO THE FIXTURE SCHEDULES ON THIS ARCHITECTURAL SHEETS FOR PIPING <br />CONNECTION SIZES AND MOUNTING HEIGHTS OF FIXTURES IF NOT SHOWN HERE. <br />9.COORDINATE ALL UNDER-SLAB PIPING LOCATIONS WITH ALL OTHER DISCIPLINES. <br />VERIFY EXISTING STRUCTURAL MEMBERS FOOTINGS PRIOR TO CONSTRUCTION TO <br />ENSURE THE SANITARY PIPING WILL NOT INTERFERE WITH THE STRUCTURAL MEMBER. <br />NOTIFY GENERAL CONTRACTOR AND ENGINEER IF THERE ARE ANY POTENTIAL <br />CONFLICTS. <br />10.PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING OR DRILLING ANY <br />HOLES IN THE MILLWORK AS REQUIRED FOR PLUMBING CONNECTIONS. <br />11.ALL BURIED WATER PIPING SHALL BE INSTALLED USING UNBROKEN LENGTHS OF TYPE <br />"K" COPPER. NO BURIED JOINTS. INSTALL 1/2" THICK BITUMINOUS PIPE WRAP INSULATION <br />ON ALL BURIED PIPING. <br />12.ALL WATER PIPING SHUT-OFF VALVES SHALL BE LOCATED NO MORE THAN 24" ABOVE <br />FINISHED CEILINGS OF ALL WATER BRANCHES WHEN WATER PIPES ARE RAN RIGHT <br />ABOVE THE CEILINGS AND NOT IN JOIST SPACE. <br />13.CONDENSATE DRAIN PIPING SHALL BE INSULATED WITH 1/2" INSULATION ANYWHERE <br />ROUTED ABOVE GRADE INSIDE BUILDING. <br />14.CONTRACTOR SHALL SCOPE AND VERIFY INVERT ELEVATIONS OF SEWERS TO WHICH <br />NEW WASTE LINES ARE TO BE CONNECTED BEFORE ANY PURCHASING, ROUGHING-IN OR <br />INSTALLATION OF NEW WASTE SYSTEM. <br />15.CONTRACTOR SHALL VERIFY AND COORDINATE LOCATION OF ALL PLUMBING LINES WITH <br />DUCTWORK, FIRE PROTECTION AND ELECTRICAL SERVICES. VERIFY WITH GENERAL <br />CONTRACTOR BEFORE BEGINNING WORK. <br />16.THE INSTALLATION OF ALL VALVES, UNIONS, THERMOMETERS, GAUGES, OR OTHER <br />INDICATING RECORDING EQUIPMENT AND SPECIALTIES REQUIRING FREQUENT READING, <br />REPAIRS, ADJUSTMENT, INSPECTION, REMOVAL OR REPLACEMENT SHALL BE <br />CONVENIENTLY AND ACCESSIBLY LOCATED WITH REFERENCE TO THE FINISHED <br />BUILDING. <br />17.WASTE PIPING UNDER SLAB SHALL BE A MINIMUM OF 2" DIAMETER. <br />18.SUSPEND ALL HORIZONTAL SERVICE PIPING SHOWN ON THIS PROJECT SUCH AS, BUT <br />NOT LIMITED TO; WATER, SANITARY WASTE/VENT, GAS FROM UNDERSIDE OF ROOF <br />AND/OR FLOOR STRUCTURE, UNLESS OTHERWISE NOTED OR INDICATED. HOLD SUCH <br />PIPING AS HIGH AS <br />19.CONTRACTORS AND SUB-CONTRACTORS SHALL CAREFULLY REVIEW THE <br />CONSTRUCTION DOCUMENTS INCLUDING BUT NOT LIMITED TO THESE DRAWINGS AND <br />SPECIFICATIONS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED <br />THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED <br />WITHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. <br />20.COORDINATE WITH THE WORK OF OTHER SECTIONS, EQUIPMENT FURNISHED BY <br />OTHERS, REQUIREMENTS OF THE OWNER, AND WITH THE CONSTRAINTS OF THE <br />EXISTING CONDITIONS OF THE PROJECT SITE. PROVIDE PIPE RISES, DROPS, AND <br />OFFSETS, AS REQUIRED FOR FIELD INSTALLATION AND TRADE COORDINATION. NOTIFY <br />ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING WORK. <br />21.ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS AS APPROVED <br />AND AMENDED BY THE GOVERNING CITY, INCLUDING APPLICABLE SECTIONS OF ANY <br />INTERIM AMENDMENTS AT THE TIME OF THE PROPOSAL. PURCHASE ALL PERMITS <br />ASSOCIATED WITH THE WORK. OBTAIN ALL INSPECTIONS REQUIRED BY CODE. <br />22.DOMESTIC HOT WATER PIPING AND DOMESTIC COLD WATER PIPING SHALL BE <br />INSULATED PER SPECIFICATIONS A SECTION C404.4 OF 2015 IECC AND PROJECT <br />SPECIFICATIONS. ALL DOMESTIC HOT WATER PIPING AND DOMESTIC COLD WATER <br />PIPING SHALL BE INSULATED WITH FIBERGLASS PIPE INSULATED WITH FOIL-CRAFT <br />LAMINATE VAPOR BARRIER FASTENED WITH PRESSURE SENSITIVE TAPE AND LAPPED 12" <br />MINIMUM. ALL FITTINGS, VALVES, FLANGES, ETC. SHALL BE COVERED WITH PVC FITTING <br />COVER, TAPED AND TACKED FASTED AND LABELED. <br />PIPE Ø INSULATION THICKNESS <br />1/2" 1" <br />3/4" 1" <br />1" 1" <br />1-1/4"1-1/2" <br />1-1/2"1-1/2" <br />2"1-1/2" <br />2-1/2"1-1/2" <br />3"2" <br />23.VERIFY SERVICE CONNECTION POINTS, SIZES, ELEVATIONS, AND METERING LOCATIONS <br />FOR PROJECT WITH LOCAL UTILITIES COMPANY'S AND/OR CIVIL ENGINEER. SERVICES TO <br />INCLUDE BUT NOT LIMITED TO DOMESTIC WATER, FIRE, SANITARY SEWER, STORM <br />SEWER. <br />24.CONTRACTOR SHALL INSTALL CLEANOUTS IN ACCESSIBLE LOCATIONS ON ALL SANITARY <br />STACKS AND PIPING PER CODE. ACCESSIBLE CLEANOUTS SHALL ALSO BE INSTALLED AT <br />ANY CHANGE IN DIRECTION AS PER CODE. <br />25.CONTRACTOR IS TO SURVEY ALL EXISTING SANITARY, VENT, AND STORM PIPING THAT IS <br />TO REMAIN, OR TO BE RESUED AND REPAIR AS NEEDED PER CODE. <br />26.CONTRACTOR IS TO COORDINATE PAINTING OF PIPES WITH THE ARCHITECTURAL <br />SHEETS. ALL PIPING SHALL BE LABELED, AND INSTALLED PER CODE. <br />27.CONTRACTOR SHALL INSTALL SHUT OFF VALVES AT EVERY WATER BRANCH EVEN IF <br />NOT SHOWN ON PLANS. <br />28.IN ACCORDANCE WITH NFPA 13 ALL PENETRATIONS (PIPE, DUCTWORK, CONDUIT, ETC.) <br />PASSING THROUGH CONCRETE SLABS SHALL BE INSTALLED WITH ONE INCH CLEARANCE <br />ON ALL SIDES FOR PENETRATIONS THREE INCHES IN DIAMETER OR SMALLER AND WITH <br />TWO INCHES CLEARANCE ON ALL SIDES FOR PENETRATIONS FOUR INCHES IN DIAMETER <br />AND LARGER. CONTRACTOR SHALL FILL ALL PENETRATIONS WITH APPROVED FIRE <br />RATED MASTIC. <br />PLUMBING - PIPING SYSTEMS <br />1.ALL PLUMBING WORK IS TO BE DONE IN ACCORDANCE WITH THE <br />REQUIREMENTS OF THE 2015 INTERNATIONAL PLUMBING CODE AND LOCAL <br />AMENDMENTS. <br />2.THE CONTRACTOR SHALL COORDINATE WITH ALL STATE AND LOCAL BUILDING <br />REGULATION AGENCIES AND UTILITY COMPANY(S) IN THE PROCUREMENT OF <br />AND PAYMENT OF ALL PERMITS, LICENSES, FEES AND CHARGES REQUIRED <br />FOR THE PERFORMANCE OF THE WORK <br />3.THE CONTRACTOR IS RESPONSIBLE FOR ALL FEES AND DIRECT EXPENSES <br />INVOLVED IN ANY INSPECTION REQUIRED FOR THE PROJECT. <br />4.PIPING MATERIAL SHALL BE AS CALLED FOR IN THE SPECIFICATIONS OR AS <br />DETAILED ON THE DRAWING(S), AND SHALL BE PLENUM RATED. <br />5.VALVES ON WATER LINES SHALL BE TWO PIECE BRONZE BALL VALVES. DO <br />NOT SUBSTITUTE GATE OR GLOBE VALVES. VALVES SHALL BE FULL PORT, THE <br />SAME SIZE AS THEIR INLET PIPING. <br />6.ALL PLUMBING FIXTURES ARE TO BE FURNISHED COMPLETE WITH <br />NECESSARY STOPS, TRAPS, TAILPIECES, TRIM, SHUT-OFF VALVES, BFP, ETC, <br />EVEN IF NOT SHOWN IN THE DRAWINGS. SINKS SHALL HAVE A SLIP JOINT <br />P-TRAP. <br />7.THE CONTRACTOR SHALL COOPERATE AND COORDINATE HIS WORK WITH THE <br />WORK OF OTHER SUB-CONTRACTORS ON THE PROJECT. <br />8.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING A COMPLETE <br />AND FUNCTIONAL SYSTEM IN ACCORDANCE WITH THE INTENT OF THE PLANS, <br />WHETHER OR NOT EVERY ELEMENT THEREOF IS SPECIFICALLY CALLED OUT. <br />9.DO NOT INSTALL CAPPED AIR CHAMBERS AT FIXTURES. INSTALL WATER <br />HAMMER ARRESTERS AS SHOWN ON DETAIL 10/P400, AND AT THE END OF <br />EVERY WATER LINE BRANCH EVEN IF NOT SHOWN ON PLANS. ARRESTERS <br />ARE TO BE RATED FOR INSTALLATION IN CONCEALED LOCATIONS. <br />10.PLUMBING PIPING SHALL NOT BE INSTALLED ABOVE ELECTRICAL PANELS. <br />PROVIDE REQUIRED CLEARANCES PER "N.E.C." COORDINATE ELECTRICAL <br />PANELS LOCATIONS WITH THE ELECTRICAL CONTRACTOR. <br />11.PIPE INSULATION SHALL BE AS CALLED FOR IN THE SPECIFICATIONS OR AS <br />DETAILED ON THE DRAWING(S). <br />12.CONTRACTOR SHALL PROVIDE ONE YEAR WARRANTY ON ALL WORK <br />PERFORMED. <br />13.PROVIDE CHROME ESCUTCHEON COVER PLATES AT ALL PIPE PENETRATIONS <br />OF FINISHED WALL SURFACES. <br />14.PLUMBING SUB-CONTRACTOR SHALL INFORM THE ELECTRICAL <br />SUB-CONTRACTOR OF THE VOLTAGE AND POWER REQUIREMENTS OF ALL <br />PLUMBING EQUIPMENT TO BE INSTALLED AND ENSURE THAT THE PLUMBING <br />EQUIPMENT IS IN THE CORRECT VOLTAGE. <br />15.IT IS THE CONTRACTOR'S RESPONSIBILITY TO ROUTE ALL WATER PIPING <br />AROUND SPACES WITH TEMPERATURES BELOW FREEZING (i.e. ABOVE <br />CEILING SPACES, CHASES, EXTERIOR WALLS, ETC.). IF FREEZING OF ANY <br />WATER PIPING OCCURS IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY TO <br />REPAIR THE PIPING THRU A NON-FREEZING SPACE TO THE <br />FIXTURE/APPLIANCE ORIGINALLY SERVED BY THE FROZEN PIPING. <br />16.ALL CAULKING ON BUILDING PENETRATIONS SHALL BE ELASTOMERIC <br />POLYURETHANE (NO EXCEPTIONS) EQUAL TO "VULKEM" ANY CONTRACTOR <br />WHO USES SILICONE OR ANY OTHER CAULKING WILL BE REQUIRED TO <br />REMOVE AND REPLACE WITH ELASTOMERIC POLYURETHANE. <br />17.INSTALL ACCESS PANELS OR DOORS WHERE EQUIPMENT AND/OR VALVES <br />ARE LOCATED IN CONCEALED SPACES. COORDINATE LOCATIONS WITH ARCH <br />DRAWINGS. <br />18.ALL WATER HEATERS AND HOT WATER STORAGE TANKS SHALL HAVE A DRAIN <br />VALVE INSTALLED AT THE BOTTOM OF THE TANK AS REQUIRED BY CODE AND <br />SHALL DRAIN TO FLOOR DRAIN OR MOP SINK. DRAIN PANS SHOULD BE <br />INCLUDED WITH ALL WATER HEATERS. ALL WATER HEATERS SHALL DRAIN <br />INTO MOP SINKS, FLOOR DRAIN, FLOOR SINK VIA INDIRECT CONNECTION. <br />WH'S ARE TO BE SET TO 140F. <br />19.CONTRACTOR SHALL PROVIDE THE ENGINEER WITH PLUMBING SUBMITTALS <br />CONTAINING INFORMATION SHEETS ON ALL PLUMBING FIXTURES, PIPE, <br />MATERIALS, VALVES, AND ALL INDIVIDUAL ITEMS SPECIFIED IN NOTES ON THE <br />PLANS. <br />20.BEFORE BEING PLACED IN SERVICE AND AFTER TESTING IS COMPLETED, ALL <br />POTABLE WATER PIPING SHALL BE CHLORINATED AS SPECIFIED HEREIN, IN <br />ACCORDANCE WITH AWWA STANDARD C651 OR AWWA C652 AND AS <br />REQUIRED BY THE LOCAL HEALTH DEPARTMENT CODES. <br />21.SANITARY WASTE & VENT PIPING SHALL FLOW BY GRAVITY WITHOUT THE USE <br />OF ANY PUMPS. VENT PIPING SHALL BE PIPED SEPARATELY FROM INDIRECT <br />WASTE VENT PIPING. <br />22.ALL LAVATORY AND SINKS SHALL BE PROVIDED WITH PRESSURE BALANCING <br />TEMPERING VALVES LOCATED BELOW SINK TO LIMIT THE HOT WATER <br />TEMPERATURE TO 105 AND 110 DEGREE F. MAXIMUM. <br />23.HOT & COLD WATER PIPING SYSTEMS SHALL BE INSTALLED PER PLUMBING ND <br />HEALTH CODES FOR ALL FOOD PREPORATIONSINKS AND EQUIPMENT SHALL <br />BE SERVED BY A HOT WATER PIPING SYSTEM WITH 140 DEGREE F. HOT <br />WATER AND RECIRCULATING SYSTEM <br />24.CONTRACTOR IS TO VERIFY THE EXISTING WATER PRESSURE PRIOR TO <br />CONSTRUCTION. THE PURESSURE AFTER THE RPZ AND BFP LOCATED INSIDE <br />OF THE BUILDING SHALL BE A MIN OF 65 PSI. CONTACT GC AND ENGINEER IF <br />THIS IS NOT THE CASE. <br />25.AUTOMATIC FIRE PROTECTION AND FIRE SPRINKLER TO BE ENGINEERED AND <br />DESIGNED UNDER THE GC SCOPE OF WORK. RELOCATION AND REROUTING <br />OF RISERS AND ASSOCIATED PIPING IS TO BE DONE BY FIRE ROTECTION <br />CONTRACTOR. <br />26.CONTRACTOR IS TO FIELD VERIFY LOCATIONS OF EXISTING HOSE BIBBS AND <br />RECONNECT THEM TO THE NEW WATER SYSTEM WITH A SHUT OFF VALVE, <br />AND PER CODE. SEE PLUMBING SCHEDULE NEW HOSE BIBBS IF NEEDED. <br />1.ALL DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR SHALL CAREFULLY EXAMINE EXISTING CONDITION <br />BEFORE STARTING ANY WORK. <br />2.ALL CONNECTION TO EXISTING SERVICE SHALL BE MADE IN AN APPROVED MANNER. <br />3.THE EXISTING SYSTEM SHALL BE LEFT IN PERFECT ORDER UPON COMPLETION OF NEW WORK. <br />4.LOCATION AND SIZES OF EXISTING PIPING ARE APPROXIMATE. EXACT SIZES AND LOCATION OF ALL EXISTING <br />PIPE SHALL BE VERIFIED IN THE FIELD. <br />5.ALL EXISTING PIPING, VALVES, INSULATION ETC DAMAGED BY NEW WORK SHALL BE REPAIRED AND <br />REPLACED WITHOUT EXTRA CHARGES TO THE OWNER. <br />6.BEFORE SUBMITTING PROPOSAL, BIDDERS SHALL CAREFULLY EXAMINE FIELD CONDITIONS AND CONTRACT <br />DRAWINGS OF ALL TRADES. SUBMISSION OF PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT REQUIRED <br />EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR EXTRA LABOR, EQUIPMENT OR MATERIALS REQUIRED DUE <br />TO DIFFICULTIES WHICH COULD OF BEEN FORESEEN WILL BE BE RECOGNIZED. <br />7.COORDINATE INSTALLATION OF NEW WASTE PIPING IN CEILIGN BELOW THE EXISTING CONDITION. RESTORE <br />ORIGINAL CONDITIONS OF ANY DISTURBED WORK. <br />8.REMOVE ALL EXISTING INACTIVE OR ABANDONED WASTE, VENT, WATER LINES WITHIN CONTRACT AREA. CAP <br />LINES AT SOURCE AND REMOVE FIXTURES AS INDICATED. <br />9.THOROUGHLY CLEAN EXISTING HOUSE TRAPS & HOUSE SEWERES TO POINT OF CONNECTION WITH <br />MUNICIPAL SEWER. MECHANICALLY ROD & POWER FLUSH HOUSE SEWERS TO INSURE NO BROKEN PIPE, <br />BLOCKAGE AND / OR IMPROPER PIPE PITCH. REPLACE AS REQUIRED <br />GENERAL NOTES <br />PLUMBING PIPE MATERIAL SCHEDULE <br />PIPING SYSTEM ABR.PIPING MATERIAL <br />SANITARY DRAINAGE & VENT (ABOVE GRADE)SAN, GW, OR V HUB-LESS CAST IRON OR PVC (MATCH WITH EXISTING) <br />STORM DRAINAGE (ABOVE GRADE)STORM HUB-LESS CAST IRON OR PVC (MATCH WITH EXISTING) <br />SANITARY DRAINAGE & VENT (BELOW GRADE)S, W, OR V HUB-LESS CAST IRON <br />STORM DRAINAGE (BELOW GRADE)STORM HUB-LESS CAST IRON (MATCH WITH EXISTING <br />POTABLE WATER (DOMESTIC ABOVE GRADE)CW OR HW TYPE L HARD DRAWN COPPER OR PEX TUBING AS <br />ALLOWED <br />POTABLE WATER - 2" & SMALLER (DOM. BELOW <br />GRADE)CW OR HW TYPE K SOFT ANNEALED COPPER <br />PIPE SPECIFICATIONS <br />SYSTEM <br />ABOVE GRADE <br />PIPE <br />FITTINGS <br />COUPLINGS <br />SERVICE WEIGHT HUBLESS CAST IRON SOIL PIPE: CISP1 301 <br />HUBLESS CAST IRON SOIL PIPE FITTINGS: CISP1 301 <br />STANDARDM, SHEILDED, STAINLESS STEEL COUPLINGS: CISP1 310, <br />WITH STAINLESS STEEL CORRUGATED SHIELD;STAINLESS STEEL <br />BANDS AND TIGHTENING DEVICES; AND ASTM C 564, RUBBER SLEEVE.WHERE INDICATED <br />PIPE <br />FITTINGS <br />COUPLINGS <br />BELOW GRADE <br />PIPE <br />FITTINGS <br />BELOW GRADE, ALT. <br />PIPE <br />FITTINGS <br />COUPLINGS <br />ABOVE GRADE <br />PIPE <br />FITTINGS <br />COUPLINGS <br />BELOW GRADE <br />PIPE <br />FITTINGS <br />JOINTS <br />INDIRECT <br />ABOVE GRADE <br />PIPE <br />FITTINGS <br />SERVICE WEIGHT HUBLESS CAST IRON SOIL PIPE: CISP1 301 <br />HUBLESS CAST IRON SOIL PIPE FITTINGS: CISP1 301 <br />STANDARDM, SHEILDED, STAINLESS STEEL COUPLINGS: CISP1 310, <br />WITH STAINLESS STEEL CORRUGATED SHIELD;STAINLESS STEEL <br />BANDS AND TIGHTENING DEVICES; AND ASTM C 564, RUBBER SLEEVE. <br />SERVICE WEIGHT HUB & SPIGOT, CAST IRON SOIL PIPE ASTM A74 <br />SERVICE WEIGHT HUB & SPIGOT, CAST IRON SOIL PIPE FITTINGS: ASTM A74 <br />SERVICE WEIGHT HUBLESS CAST IRON SOIL PIPE: CISPI 301 <br />HUBLESS CAST IRON SOIL PIPE FITTINGS: CISPI 301 <br />HEAVY DUTY, SHIELDED, CAST IRON COUPLINGS: ASTM A 48/A <br />48M, TWO-PIECE, CAST IRON HOUSING; STAINLESS STEEL <br />BOLTS AND NUTS; AND ASTM C 564, RUBBER SLEEVE. <br />(ONLY WHEN CORROSIVE SOILS EXIST) <br />SOLID WALL ABS, SCHEDULE 40, ASTM D 2661 <br />DWV PATTERN ABS SOCKET FITTINGS, ASTM D 2661 <br />ASTM D 2235 <br />NOTE: SOLID WALL ABS PIPE IS NOT ALLOWED FOR RESIDENTIAL <br />PROJECTS THAT ARE THREE STORIES OR OVER <br />BELOW GRADE, ALT. <br />PIPE <br />FITTINGS <br />COUPLINGS <br />BELOW GRADE, ALT. <br />PIPE <br />FITTINGS <br />JOINTS <br />HARD COPPER TUBE: ASTM B 88, TYPE L WATER TUBE, DRAWN TEMPER. <br />ASME B16.18, CAST COPPER ALLOY OR ASME B16.22, WROUGHT COPPER, <br />SOLDER-JOINT FITTINGS. <br />ASTM B 813, WATER-FLUSHABLE, LEAD-FREE FLUX; ASTM B 32, LEAD-FREE <br />ALLOY SOLDER; AND ASTM B 828 PROCEDURE. <br />SOFT COPPER TUBE: ASTM B 88, TYPE L WATER TUBE, ANNEALED TEMPER. <br />ASME B16.18, CAST COPPER ALLOY OR ASME B16.22, WROUGHT COPPER, <br />SOLDER-JOINT FITTINGS. <br />ASTM B 813, WATER-FLUSHABLE, LEAD-FREE FLUX; ASTM B 32, LEAD-FREE <br />ALLOY SOLDER; AND ASTM B 828 PROCEDURE. <br />HARD COPPER TUBE: ASTM B 88, TYPE M WATER TUBE, DRAWN TEMPER. <br />ASME B16.18, CAST COPPER ALLOY OR ASME BI 6.22, WROUGHT COPPER, <br />SOLDER-JOINT FITTINGS. <br />ASTM B 813, WATER FLUSHABLE, LEAD-FREE FLUX; ASTM B 32, <br />LEAD-FREE ALLOY SOLDER; AND ASTM B 828 PROCEDURE. <br />COPPER TYPE “M” WITH 95-5 SOLDER JOINTS. <br />THREADED END, STANDARD WEIGHT STEEL PIPE: ASTM A 53/A 53M, ASTM A <br />135, OR ASTM A 795, WITH FACTORY OR FIELD FORMED THREADED ENDS. <br />MALLEABLE IRON THREADED FITTINGS: ASME B16.3. <br />FIRE PROTECTION <br />DOMESTIC WATER <br />SANITARY SEWER & VENT <br />CONDENSATE AND INDIRECT <br />ABOVE GRADE, ALT. <br />PIPE <br />FITTINGS <br />COUPLINGS <br />GROOVED END, SCHEDULE 10 STEEL PIPE: ASTM A 135 OR ASTM A 795, <br />WITH FACTORY OR FIELD FORMED, ROLL-GROOVED ENDS. <br />GROOVED END FITTINGS: UL—LISTED, ASTM A 536, DUCTILE IRON <br />CASTING WITH OD MATCHING STEEL PIPE OD. <br />GROOVED END PIPE COUPLINGS: UL 213 AND AWWA C606, RIGID <br />PATTERN; GASKETED FITTING MATCHING STEEL PIPE OD, DUCTILE IRON <br />HOUSING WITH KEYS MATCHING STEEL PIPE AND FITTING GROOVES, <br />RUBBER GASKET LISTED FOR USE WITH HOUSING, AND STEEL BOLTS <br />AND NUTS <br />INSULATION <br />ALL HOT WATER PIPING, VALVES AND FILLINGS ABOVE THE CEILING WITHIN THE BUILDING <br />SHALL BE INSULATED WITH CERTAIN-TEED, SNAP-ON OR JOHNS MANVILLE MICRO-LOK <br />INSULATION. ALL HOT AND COLD WATER PIPING, VALVES AND FITTINGS OUTSIDE OF BUILDING <br />SHALL BE INSULATED WITH CERTAIN-TEED, SNAP-ON OR JOHNS MANVILLE MICRO-LOK <br />INSULATION WITH CHILDERS ALUMINUM ROLL JACKETING. AIR CONDITIONING CONDENSATION <br />DRAIN PIPING & ROOF DRAIN PIPING SHALL BE INSULATED W/ JOHNS MANVILLE "AEROTUBE” <br />FOAM PLASTIC PIPE INSULATION. MATERIAL TO BE APPROVED FOR R.A. PLENUM <br />APPLICATION. <br />CLEANOUTS <br />SHALL BE MANUFACTURED BY MIFAB, J.R. SMITH, OR ZURN OR SIMILAR, AS FOLLOWS: <br />A.FINISHED ROOM FLOORS: MIFAB C1100 W/NB. TOP AND GASKETED WATER-TIGHT COVER. <br />B.WALLS: MIFAB C1460-RD W/ BRONZE PLUG AND CHROME PLATED COVER. <br />C.YARD AND PARKING LOT: MIFAB C1300-MF CAST IRON SURFACE LEVEL CLEANOUT. <br />SAME AS ABOVE GRADE <br />SPECIFICATION CONTRACTOR IS TO COORDINATE/PERFORM A WATER FLOW TEST, AND PROVIDE RESULTS TO PROJECT <br />MANAGER/ENGINEER FOR REVIEW. SHOULD THE FLOW TEST RESULTS PROVE THAT THE EXISTING WATER SERVICE <br />IS INADEQUATE FOR THE PROPOSED WATER DEMAND, CONTRACTOR TO SUBMIT A WRITTEN COST PROPOSAL <br />INCLUDING TIME ESTIMATE TO COMPLETE UPGRADING THE EXISTING WATER SERVICE TO THE PROJECT MANAGER. <br />SHOULD THE EXISTING INCOMING WATER PRESSURE BE INADEQUATE FOR PROPOSED FIXTURE DEMAND, <br />CONTRACTOR TO PROVIDE AN ALTERNATE BID, AND TIME ESTIMATE, FOR THE ADDITION OF A WATER PRESSURE <br />BOOSTER PUMP TO THE PROPOSED DESIGN. <br />SEE WATER AND WASTE SERVICE CALCULATIONS BELOW. IMMEDIATELY NOTIFY PROJECT MANAGER/ENGINEER OF <br />ANY DISCREPANCIES BETWEEN DATA BELOW AND EXISTING CONDITIONS. <br />FIELD VERIFY ALL EXISTING CONDITIONS, REQUIREMENTS AND EXTENT OF WORK <br />WATER SERVICE UPGRADE NOTE <br />WATER EFFICIENCY AND CONSERVATION: <br />NEW PLUMBING FIXTURES AND FITTINGS SHALL NOT EXCEED THE MAXIMUM ALLOWABLE FLOW RATE <br />SPECIFIED IN TABLE 5.303.2.3. (5.303.2.1) <br />RESOURCE EFFICIENCY: <br />CONTRACTOR SHALL TEST AND ADJUST THE NEW WATER HEATERS AS PER THE MANUFACTURER'S <br />COMMISSIONING REQUIREMENTS IN THE INSTALLATION OPERATION AND MAINTENANCE MANUAL (IOM), (5.410.4.2) <br />TESTING AND ADJUSTING: <br />A FINAL REPORT FOR THE TESTING AND ADJUSTING OF ALL NEW SYSTEMS SHALL BE COMPLETED PRIOR TO <br />FINAL APPROVAL BY THE FIELD INSPECTOR. THIS REPORT SHALL BE SIGNED BY THE INDIVIDUAL RESPONSIBLE <br />FOR PERFORMING THESE SERVICES. (5.410.4.4) <br />AN OPERATION & SYSTEMS MANUAL SHALL BE PROVIDED TO THE OWNER OR REPRESENTATIVE AND TO THE <br />FIELD INSPECTOR AT THE TIME OF FINAL INSPECTION (5.410.4.5) <br />CALIFORNIA GREEN BUILDING CODE <br />1.DESIGN AND INSTALL A COMPLETE WET AUTOMATIC FIRE SPRINKLER SYSTEM WITH <br />COVERAGE FOR ALL AREAS. <br />2.ALL WORK SHALL BE IN ACCORDANCE WITH THE 1999 NFPA 1 <br />3.STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS AND AUTHORITIES HAVING <br />JURISDIC11ON. 3. MODIFY THE EXISTING SPRINKLER SYSTEM TO MEET THE NEEDS OF THE <br />NEW TENANT SPACE. PROVIDE NEW PIPING AND SPRINKLER HEADS. <br />4.VERIFY ALL EXISTING UTILITIES INCLUDING SIZE, LOCATION, INVERT, PRESSURE AND <br />AVAILABILITY PRIOR TO THE START OF WORK. <br />5.COORDINATE SPRINKLER PIPING WITH DUCTS, PIPING, CABLE TRAYS, CONDUITS, OTHER <br />CEILING ACCESSORIES AND EXISTING CONDITIONS. COORDINATE SPRINKLER HEAD <br />LAYOUT WITH REFLECTED CEILING PLANS, GRILLES, AND LIGHT FIXTURES. LOCATE <br />SPRINKLER HEADS SYMMETRICALLY AND IN THE CENTER OF CEILING TILES. <br />6.PRIOR TO COMMENCING WORK, SUBMIT AND OBTAIN APPROVALS FOR PIPING DRAWINGS, <br />HEAD LAYOUTS, HYDRAULIC CALCULATIONS AND MATERIALS FROM THE ARCHITECT AND <br />ALL AUTHORITIES HAVING JURISDICTION INCLUDING THE LOCAL FIRE MARSHALL AND THE <br />OWNER’S INSURANCE UNDERWRITER. <br />T.I. FIRE PROTECTION NOTES <br />SUPPLY PIPING NOTES: <br />1.AT THE POINTS OF INTERCONNECTION BETWEEN THE HOT AND COLD WATER SUPPLY PIPING SYSTEMS AND THE INDIVIDUAL <br />FIXTURES, APPLIANCES OR DEVICES, PROVISIONS SHALL BE MADE TO PREVENT UNDESIRED FLOW BETWEEN SUCH PIPING <br />SYSTEMS. <br />2.LAVATORY FAUCETS SHALL BE OF THE METERING TYPE WHEN LOCATED IN THE FOLLOWING PUBLIC RESTROOMS: <br />2.1.IN ALL OCCUPANCIES IN RESTROOMS THAT HAVE SIX OR MORE LAVATORIES. <br />2.2.IN SCHOOL OCCUPANCIES IN STUDENT-USE RESTROOMS <br />2.3.IN ASSEMBLY OCCUPANCIES IN ALL CUSTOMER OR PUBLIC-USE RESTROOMS. <br />3.THE FIXTURE SUPPLY PIPE SHALL TERMINATE NOT MORE THAN 36 INCHES FROM THE POINT OF CONNECTION TO THE <br />FIXTURE. A REDUCED-SIZE FLEXIBLE WATER CONNECTOR INSTALLED BETWEEN THE SUPPLY PIPE AND THE FIXTURE SHALL <br />BE OF AN APPROVED TYPE. THE SUPPLY PIPE SHALL EXTEND TO THE FLOOR OR WALL ADJACENT TO THE FIXTURE. <br />4.WHERE WATER PRESSURE WITHIN A BUILDING EXCEEDS 80 PSI STATIC, AN APPROVED WATER PRESSURE-REDUCING VALVE <br />CONFORMING TO ASSE 1003 OR CSA B356 WITH STRAINER SHALL BE INSTALLED TO REDUCE THE PRESSURE IN THE WATER <br />DISTRIBUTION PIPING TO NOT GREATER THAN 80 PSI STATIC. <br />4.1.THE PRESSURE-REDUCING VALVE SHALL BE DESIGNED TO REMAIN OPEN TO PERMIT UNINTERRUPTED WATER FLOW IN <br />CASE OF VALVE FAILURE. <br />5.A WATER-HAMMER ARRESTOR SHALL BE INSTALLED WHERE QUICK-CLOSING VALVES AND METALLIC PIPING ARE USED. NOT <br />REQUIRED WHERE PLASTIC PIPE IS USED FOR WATER DISTRIBUTION PIPING. <br />6.PIPE AND PIPE FITTINGS, INCLUDING VALVES AND FAUCETS, UTILIZED IN THE WATER SUPPLY SYSTEM SHALL HAVE NOT <br />MORE THAN 8-PERCENT LEAD CONTENT. <br />6.1.PIPE, PIPE FITTINGS, JOINTS, VALVES, FAUCETS AND FIXTURE FITTINGS UTILIZED TO SUPPLY WATER FOR DRINKING OR <br />COOKING PURPOSES SHALL COMPLY WITH NSF 372 AND SHALL HAVE A WEIGHTED AVERAGE LEAD CONTENT OF 0.25 <br />PERCENT OR LESS. <br />7.THE DEVELOPED LENGTH OF HOT OR TEMPERED WATER PIPING, FROM THE SOURCE OF HOT WATER TO THE FIXTURES THAT <br />REQUIRE HOT OR TEMPERED WATER, SHALL NOT EXCEED 50 FEET. <br />8.THE WATER SUPPLY CONNECTION TO COFFEE MACHINES AND NONCARBONATED BEVERAGE DISPENSERS SHALL BE <br />PROTECTED AGAINST BACKFLOW BY A BACKFLOW PREVENTER CONFORMING TO ASSE 1022 OR BY AN AIR GAP. <br />9.THE SUPPLY LINES AND FITTINGS FOR PLUMBING FIXTURES SHALL BE INSTALLED SO AS TO PREVENT BACKFLOW. PLUMBING <br />FIXTURE FITTINGS SHALL PROVIDE BACKFLOW PROTECTION IN ACCORDANCE WITH ASME A112.18.1/CSA B125.1. <br />SANITARY PIPING <br />1.HORIZONTAL DRAINAGE PIPING SHALL BE INSTALLED IN UNIFORM ALIGNMENT AT UNIFORM SLOPES. THE SLOPE OF A <br />HORIZONTAL DRAINAGE PIPE SHALL BE NOT LESS THAN; <br />[PIPE SIZE (INCHES): MINIMUM SLOPE (IN/FT)] <br />2 1/2 OR LESS 1/4 <br />3 TO 6 1/8 <br />8 OR LARGER 1/16 <br />2.THE SIZE OF THE DRAINAGE PIPING SHALL NOT BE REDUCED IN SIZE IN THE DIRECTION OF THE FLOW. <br />3.HORIZONTAL DRAINAGE PIPES IN BUILDINGS SHALL HAVE CLEANOUTS LOCATED AT INTERVALS OF NOT MORE THAN 100 <br />FEET. <br />4.ONE CLEANOUT SHALL BE REQUIRED FOR EVERY FOUR HORIZONTAL 45-DEGREE CHANGES LOCATED IN SERIES.2401027 <br />STB <br />SN <br />I <br />P <br />S <br /> <br />C <br />U <br />L <br />T <br />I <br />V <br />A <br />T <br />I <br />O <br />N <br />, <br />32 <br />0 <br />1 <br /> <br />H <br />A <br />L <br />L <br />A <br />D <br />A <br />Y <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br />AN <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />SN <br />I <br />P <br />S <br /> <br />C <br />U <br />L <br />T <br />I <br />V <br />A <br />T <br />I <br />O <br />N <br />LL <br />C <br />, <br /> <br />3 <br />2 <br />0 <br />1 <br /> <br />S <br /> <br />H <br />A <br />L <br />L <br />A <br />D <br />A <br />Y <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />03-19-2024 <br />PROFESSIONAL SEAL <br />Dr. Al Gonzalez P.E. <br />DOTec Engineering <br />424 Jefferson Street <br />St. Charles, MO 63301 <br />Ph 636-724-9872 <br />Fx 636-724-9032 <br />WWW.DOTECENGINEERING.COM <br />ALG@DOTECENGINEERING.COM <br />SHEET NUMBER: <br />P0 <br />PROJECT NUMBER: <br />DRAWN BY: <br />CHECKED BY: <br />FOR CONSTRUCTION <br />ALG <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />CL <br />I <br />E <br />N <br />T <br />: <br />DATE: <br />SHEET NAME: <br />PLUMBING NOTES <br />THIS DRAWING IS PRELIMINARY <br />UNTIL SIGNED AND SEALED BY <br />THE LICENSED PROFESSIONAL <br />NOTED BELOW. <br />THE PROFESSIONAL ENGINEER WAIVES ANY AND ALL RESPONSIBILITY <br />AND LIABILITY FOR PROBLEMS WHICH ARISE FROM FAILURE TO <br />FOLLOW THESE PLANS, SPECIFICATIONS AND DESIGN INTENT THEY <br />CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHER'S FAILURE <br />TO OBTAIN AND OR/ FOLLOW THE PROFESSIONAL ENGINEER <br />GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, <br />INCONSISTENCIES, AMBIGUITIES, OR CONFLICTS WHICH ARE <br />ALLEGED. BUILDINGS TO BE CONSTRUCTED IN FULL CONFORMANCE <br />WITH ALL APPLICABLE CODES AND RESTRICTIONS. PROFESSIONAL <br />ENGINEER TO BE NOTIFIED PRIOR TO CONSTRUCTION IN THE EVENT <br />OF CODE REVISION OR CHANGES. <br /># <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br /> <br />D <br />A <br />T <br />E <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />1 <br />12 <br />/ <br />1 <br />7 <br />/ <br />2 <br />4 <br />AH <br />J <br /> <br />C <br />O <br />M <br />M <br />E <br />N <br />T <br /> <br />R <br />E <br />V <br />2 <br />2/ <br />1 <br />4 <br />/ <br />2 <br />5 <br />AH <br />J <br /> <br />C <br />O <br />M <br />M <br />E <br />N <br />T <br /> <br />R <br />E <br />V <br />2/14/25 <br />9/30/26 <br />3201 S Halladay St <br />5/5/2025