Laserfiche WebLink
RAFTER SIZE & SPACING <br />RAFTER SPAN ___' _____" <br />CONTINUOUS LEDGER <br />12" <br />MAX. <br />6" <br />MIN. <br />FOR HEADER SIZE <br />SEE TABLE "B" <br />2500 P.S.I. CONCRETE <br />SEE TABLE "A" <br />DETAIL <br />"A" <br />DETAIL "C" <br />2X CONTINUOUS LEDGER <br />3/8"ø X 5" LONG LAG SCREWS <br />INTO STUDS AT 16" O.C. <br />JOIST HANGER OR SOLID BLOCKINGNAIL RAFTER TO BLOCKING <br />SEE ROOFING NOTE <br />SPECIFY ROOFING & SHEATHING OR OPEN LATTICE <br />____' ____" POST SPACING <br />OVERALL LENGTH <br />LONG SIDE MUST BE 65% OPEN <br />DETAIL "D" <br />DETAIL "B" <br />6" <br />MIN. <br />6' <br /> <br />8 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />E <br />A <br />R <br />A <br />N <br />C <br />E <br />FOOTING 12" <br />BELOW GRADE <br />SEE TABLE <br />"C" FOR SIZE <br />EXISTING <br />HOUSE <br />WALL <br />END VIEW <br />SIDE VIEW <br />DETAIL "A" <br />SLOPE TO DRAIN <br />___" OVERHANG <br />12 <br />IMPORTANT NOTE TO PERMIT APPLICANT: <br />Prior to expending time, money or effort in plan preparation, the applicant should contact the Planning Division at (714) 647-5804 <br />regarding zoning, setbacks, landscape, aesthetics and other requirements. A fully dimensioned SITE PLAN shall be required on a <br />separate 8 1/2” x 11” sheet of paper. Ask for handout on Residential Site Plan Information (patio cover is not permitted within 5 feet of a property line). <br />PLANNING& BUI LDINGAGENCY <br />SANTAANACITY OF PATIO COVER FOR ONE AND <br />TWO FAMILY DWELLINGS <br />STD-02 CBC 2010 <br /> FOOTINGS: <br />CBC APPENDIX I. A PATIO COVER MAY BE SUPPORTED ON A CONCRETE SLAB ON <br />GRADE WITHOUT FOOTINGS, PROVIDED THE SLAB IS NO LESS THAN 3 1/2" THICK AND <br />FURTHER PROVIDED THAT THE COLUMNS DO NOT SUPPORT LIVE AND DEAD LOADS IN <br />AN EXCESS OF 750 POUNDS PER COLUMN. <br />TABLE A USE: <br />1. DETERMINE ROOF SLOPE <br />2. SELECT RAFTER SPAN <br /> RETNEC RETFAR TCELES .3 <br />TO CENTER SPACING <br />4. SELECT RAFTER SIZE <br />TABLE B USE: <br />1. SELECT SPAN OF RAFTER <br />2. SELECT POST SPACING <br />3. SELECT HEADER SIZE <br />TABLE C USE: <br />1. SELECT SPAN OF RAFTER <br />2. SELECT POST SPACING <br />3. SELECT FOOTING SIZE <br />RAFTER SPACING ROOF SLOPE ROOF SLOPE <br /> SIZE C. TO C. < 4:12 ≥ 4:12 <br /> 12" 8'-0" 8'-6" <br /> 2X4 16" 7'-0" 7'-6" <br /> 24" 6'-0" 6'-6" <br /> 12" 13'-0" 13'-6" <br /> 2X6 16" 11'-6" 12'-0" <br /> 24" 10'-0" 10'-6" <br /> 12" 17'-0" 17'-6" <br /> 2X8 16" 15'-6" 16'-0" <br />24" 13'-6" 14'-0" <br />PATIO SIZE ___________________________ <br />POST SIZE ___________________________ <br />POST SPACING________________________ <br />HEADER SIZE _________________________ <br />RAFTER SPAN ________________________ <br />RAFTER SIZE <br /> & SPACING _________________________ <br />ROOF PITCH __________________________ <br />ROOFING MATERIAL ___________________ <br />GRADE OF LUMBER: D.F. NO.1 <br /> D.F. NO.2 <br />x <br />x @ " O.C. <br />x <br />x <br />SPAN OF POST SPACING / HEADER SIZE <br />RAFTER 4x4 4x6 4x8 4x10 <br /> 10'-0" 5'-6" 9'-0" 11'-6" 15'-0" <br /> 12'-0" 5'-6" 8'-6" 11'-0" 14'-0" <br /> 14'-6" 5'-0" 8'-0" 10'-6" 13'-0" <br /> 16'-0" - 7'-6" 10'-0" 12'-0" <br /> 18'-0" - 7'-0" 9'-6" 11'-6" <br />Page 1 of 2 <br />Planning & Building Agency <br />Building Safety Division <br />20 Civic Center Plaza <br />P.O. Box 1988 (M-19) <br />Santa Ana, CA 92702 <br />(714) 647-5800 <br />www.santa-ana.org <br />TABLE A <br />ROOF RAFTER SPAN <br />SPAN OF <br />RAFTER <br />10'-0" 5'-6"/15" sq. 9'-0"/18" sq. 11'-6"/21" sq. 15'-0"/24" sq. <br /> 12'-0" 5'-6"/16" sq. 8'-6"/20" sq. 11'-0"/22" sq. 14'-0"/26" sq. <br /> 14'-6" 5'-0"/16" sq. 8'-0"/20" sq. 10'-6"/24" sq. 13'-0"/26" sq. <br /> 16'-0" - 7'-6"/21" sq. 10'-0"/24" sq. 12'-0"/27" sq. <br /> 18'-0" - 7'-0"/21" sq. 9'-6"/26" sq. 11'-6"/28" sq. <br />TABLE B <br />TABLE C <br />POST SPACING / FOOTING SIZE <br />rev: 07/19/2011 <br />2513 W Occidental <br />St11/14/2024