Laserfiche WebLink
12" <br />12 <br />" <br />GALVANIZED <br />12"x12"x7 GAGE <br />"T" W/6-5/8" Ø LAGS <br />4"x POST <br />4"x BEAM <br />DETAIL "D" <br />12 <br />" <br />ANCHOR <br />BOLT <br />STAND-OFF <br />POST <br />BASE <br />8" <br />STANDOFF 1" <br />EMBED <br />ANCHORS IN <br />CONCRETE <br />DETAIL "C" <br />GRADE <br />1" STAND-OFF <br />1"x6" KNEE <br />BRACE <br />2' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />2-1/2" Ø x 5" LONG LAGS SCREWS <br />EACH END <br />(SEE DETAIL "E") <br />45∞ <br />4"x4" POST MINIMUM <br />DETAIL "B" <br />APPROVED CAPGALVANIZED 21/2"x 12"x 7 GAGE THICK <br />STEEL STRAP W/4-5/8"Ø LAGS <br />3 1/2" <br />3 1/2" <br />2" <br />2" <br />4"x BEAM <br />DETAIL "B" ALTERNATE <br />4"x4"POST 5-8D NAILS, <br />EACH END <br />4"x BEAM <br />2" <br />4"x POST <br />4"x4" KNEE BRACE <br />2-1/2" Ø x5" LONG LAG SCREWS <br />DETAIL "E" <br />4"x4" KNEEBRACE <br />Page 2 of 2 <br />NOTES: <br />1. ALL MATERIALS: LUMBER, HARDWARE, PLYWOOD, ROOFING, ETC. SHALL BE NEW <br /> AND BEAR MANUFACTURER'S OR CERTIFIED AGENCY'S GRADE MARK. <br />2. ALL CONSTRUCTION SHALL CONFORM TO THE CALIFORNIA BUILDING <br /> CODE CURRENTLY IN EFFECT. <br />3. CONCRETE SLAB TO BE MINIMUM 3 1/2" THICK. <br />4. POSTS SHALL BE MINIMUM 4"x4". <br />5. BOTTOM OF POSTS SHALL BE ONE INCH (1") ABOVE SLAB. <br />6. ROOF SHEATING SHALL BE: <br /> a. 1/2" PLYWOOD, CDX, 5 PLY EXTERIOR GLUE, WITH INDEX 32/16, T & G <br /> STRUCTURAL I, WITH 10 d AT 6" O/C AT SUPPORTED ENDS, AND12" O/C ALONG <br /> INTERMEDIATE FRAMING MEMBERS, OR <br /> b. 1" BOARD SPAN 32"; 2" SOLID T&G SPAN 8'-0"; 2"x2" SELF-SPACED SPAN 6'-0". <br />7. ROOFING SHALL BE MIN. CLASS "C" ROOF COVERING (CBC TABLE 1505.1) OF: <br /> a. WOOD SHAKES: 4/12 PITCH <br /> b. WOOD SHINGLES: 3/12 PITCH <br /> c. BUILT-UP ROOF SLOPE TO DRAIN (MINIMUM 1/4"/FT.) <br /> d. CLAY AND CONCRETE ROOF TILES INSTALLED IN ACCORDANCE WITH <br /> MANUFACTURER'S INSTRUCTIONS. <br />8. MAXIMUM HEIGHT FOR A PATIO COVER IS TWELVE FEET. <br />9. PATIO COVER SHALL BE USED ONLY FOR RECREATIONAL OUTDOOR LIVING <br /> PURPOSE AND NOT AS CARPORT, GARAGE, STORAGE ROOM OR HABITABLE ROOM. <br />10. ENCLOSURE WALLS MAY HAVE ANY CONFIGURATION, PROVIDED THE OPEN AREA <br /> OF THE LONGER WALL AND ONE ADDITIONAL WALL IS EQUAL TO AT LEAST SIXTY- <br /> FIVE PERCENT OF THE AREA BELOW A MINIMUM OF 6'-8" OF EACH WALL, <br /> MEASURED FROM THE FLOOR. <br />11. OPENINGS MAY BE ENCLOSED WITH INSECT SCREENING OR PLASTIC THAT IS <br /> READILY REMOVABLE, TRANSLUCENT, OR TRANSPARENT PLASTIC NOT MORE THAN <br /> 1/8 INCH IN THICKNESS. <br />12. EMERGENCY EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOMS MAY OPEN <br /> INTO AN AREA OF AN UNENCLOSED PATIO COVER. <br />13. PATIO COVER MUST BE AT LEAST 5 FEET FROM PROPERTY LINES. <br />PERSON RESPONSIBLE FOR DESIGN AND CONSTRUCTION OF PATIO COVER: <br />______________________________________ ________________________________________ __________________ <br /> PRINT NAME SIGNATURE DATE <br />rev: 07/19/2011 <br />2513 W Occidental <br />St11/14/2024