My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
302 E Santa Clara Ave - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Santa Clara Ave
>
302 E Santa Clara Ave
>
302 E Santa Clara Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:33:13 AM
Creation date
6/5/2025 7:33:06 AM
Metadata
Fields
Template:
Plan
Permit Number
101120053
Full Address
302 E Santa Clara Ave
Text box
ID:
1
Creator:
Import Agent
Created:
6/5/2025 7:33 AM
Modified:
6/4/2025 2:40 PM
Text:
http://www.icc-es.org/
ID:
2
Creator:
Import Agent
Created:
6/5/2025 7:33 AM
Modified:
6/4/2025 2:40 PM
Text:
http://www.eagleroofing.com/
ID:
3
Creator:
Import Agent
Created:
6/5/2025 7:33 AM
Modified:
6/4/2025 2:40 PM
Text:
http://www.icc-es.org/reports/pdf_files/ICC-ES/ESR-2015P.pdf
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed <br />as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as <br />to any finding or other matter in this report, or as to any product covered by the report. <br />Copyright © 2014 Page 1 of 4 <br />1000 <br /> <br />ICC-ES Evaluation Report ESR-1900* Reissued February 2014 <br /> This report is subject to renewal March 1, 2016. <br />www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council <br />® <br /> <br />DIVISION: 07 00 00—THERMAL AND MOISTURE <br />PROTECTION <br />Section: 07 32 16—Concrete Roof Tiles <br /> <br />REPORT HOLDER: <br /> <br />EAGLE ROOFING PRODUCTS, A DIVISION OF <br />BURLINGAME INDUSTRIES, INC. <br />3546 NORTH RIVERSIDE AVENUE <br />RIALTO, CALIFORNIA 92377 <br />(909) 822-6000 <br />www.eagleroofing.com <br /> <br />EVALUATION SUBJECT: <br /> <br />EAGLE® AND EAGLELITE® INTERLOCKING CONCRETE <br />ROOFING TILES: CAPISTRANO, MALIBU, BEL AIR <br />ESTATE, DOUBLE EAGLE BEL AIR, PONDEROSA, <br />DOUBLE EAGLE PONDEROSA, GOLDEN EAGLE, <br />ARTISAN AND TAPERED ARTISAN <br /> <br />1.0 EVALUATION SCOPE <br />Compliance with the following codes: <br /> 2012 and 2009 International Building Code® (IBC) <br /> 2012 and 2009 International Residential Code® (IRC) <br />Properties evaluated: <br /> Fire classification <br /> Weather resistance <br /> Wind-uplift resistance <br />2.0 USES <br />The Eagle® and Eaglelite® concrete roof tiles installed over <br />solid sheathing are used as Class A roof coverings in <br />accordance with IBC Section 1505.2 and IRC Section <br />R902.1. <br />3.0 DESCRIPTION <br />3.1 Eagle® Tiles: <br />These roof tiles are interlocking extruded concrete roof <br />tiles composed of Type II portland cement, washed sand, <br />and proprietary additives and comply with ASTM C1492. <br />Mineral coloring oxides are mixed with the portland cement <br />and water for through-color or for surface application <br />following extrusion. All roof tiles are cured to reach <br />required strength before shipment. Tiles are manufactured <br />with 3/4-inch-wide (19 mm) interlocking sidelaps designed <br />to resist surface water penetration and maintain proper <br />alignment. All tiles have protruding head lugs on the <br />underside, which provide for mechanical attachment over <br />battens, or provide a stable foundation for nail attachment <br />to solid decking. Two nail holes are provided for low profile <br />tiles. Three nail holes are provided for medium and high <br />profile tiles. <br />Product designations, dimensions and installed dry <br />weights are indicated in Table 1. Roof tile profiles are <br />illustrated in Figure 1. <br />3.2 Eaglelite® Tiles: <br />Eaglelite® tiles are produced in the same size, manner and <br />shapes as the conventional-weight Eagle® tiles described <br />in Section 3.1, except for substitution of lightweight <br />aggregates and additives for sand. Product designations, <br />dimensions and installed dry weights are indicated in <br />Table 1. Roof tile profiles are illustrated in Figure 1. <br />4.0 INSTALLATION <br />4.1 General: <br />Installation of the Eagle® and Eaglelite® concrete roof tiles <br />must be in accordance with the Concrete and Clay Roof <br />Tile Installation Manual for Moderate Climate Regions, <br />dated March 2010, published by the Tile Roofing Institute <br />and Western States Roofing Contractors Association <br />(hereinafter referred to as the TRI/WSRCA installation <br />manual), and recognized in ICC-ES ESR-2015P, except as <br />otherwise noted in this report. This report and the <br />TRI/WSRCA installation manual must be available at the <br />jobsite at all times during installation. The minimum roof <br />slope on which the roof tiles are installed must be 21/2:12 <br />(20.83%). Care must be taken during field installation to <br />ensure that horizontal joints are kept parallel to the eave <br />and vertical joints are at right angles to the eave in order to <br />ensure uniform contact between the tiles and proper fit. <br />All cracked and broken roof tiles must be replaced. <br />Underlayment must comply with and be installed in <br />accordance with IBC Section 1507.3.3 or IRC Section <br />R905.3.3, as applicable. <br />4.2 Adhesive Set Systems: <br />The roof tiles may be installed with roof tile adhesives that <br />are recognized in a current ICC-ES evaluation report for <br />use in concrete roofing tile applications. Installation of tiles <br />using these adhesive set systems must be in accordance <br />with the adhesive manufacturer’s ICC-ES evaluation <br />report. <br />4.3 Fire Classification: <br />When installed in accordance with this report, the Eagle® <br />and Eaglelite® concrete roof tiles are Class A roof <br />coverings in accordance with IBC Section 1505.2 and IRC <br />*Revised June 2014 <br />302 E Santa Clara Ave <br />9/25/2024
The URL can be used to link to this page
Your browser does not support the video tag.