My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
302 E Santa Clara Ave - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Santa Clara Ave
>
302 E Santa Clara Ave
>
302 E Santa Clara Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:33:13 AM
Creation date
6/5/2025 7:33:06 AM
Metadata
Fields
Template:
Plan
Permit Number
101120053
Full Address
302 E Santa Clara Ave
Text box
ID:
1
Creator:
Import Agent
Created:
6/5/2025 7:33 AM
Modified:
6/4/2025 2:40 PM
Text:
http://www.icc-es.org/reports/pdf_files/ICC-ES/ESR-1709.pdf
ID:
2
Creator:
Import Agent
Created:
6/5/2025 7:33 AM
Modified:
6/4/2025 2:40 PM
Text:
http://www.icc-es.org/Reports/pdf_files/ESR-2015P.pdf
ID:
3
Creator:
Import Agent
Created:
6/5/2025 7:33 AM
Modified:
6/4/2025 2:40 PM
Text:
http://www.icc-es.org/Reports/pdf_files/ESR-2015P.pdf
ID:
4
Creator:
Import Agent
Created:
6/5/2025 7:33 AM
Modified:
6/4/2025 2:40 PM
Text:
http://www.icc-es.org/Reports/pdf_files/ESR-2015P.pdf
ID:
5
Creator:
Import Agent
Created:
6/5/2025 7:33 AM
Modified:
6/4/2025 2:40 PM
Text:
http://www.icc-es.org/reports/pdf_files/ICC-ES/ESR-2015P.pdf
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ESR-1900 | Most Widely Accepted and Trusted Page 2 of 4 <br /> <br />Section R902.1. When roof tiles are installed with a roof tile <br />adhesive, installation must be in accordance with <br />ESR-1709. <br />4.4 Wind Resistance: <br />4.4.1 2012 IBC: For ultimate design wind speeds (Vult) of <br />130 mph (209 km/h) or less and mean roof heights of <br />60 feet (18.3 m) or less, tiles must be installed in <br />accordance with the prescriptive parameters of Table <br />1507.3.7 of the IBC. For applications beyond these <br />prescriptive parameters, the tiles and the fastening <br />systems must be designed in accordance with Figure 1 of <br />ESR-2015P, Design Considerations for High Wind <br />Applications Under the 2012 IBC and IRC (ASCE 7-10). <br />4.4.2 2012 IRC: For basic wind speeds of 100 mph <br />(161 km/h) or less and mean roof heights of 40 feet <br />(12.2 m) or less, tiles must be installed in accordance with <br />the prescriptive parameters of Section R905.3.7 of <br />the IRC. For applications beyond these prescriptive <br />parameters, the tiles and the fastening systems must be <br />designed in accordance with Figure 1 of ESR-2015P, <br />Design Considerations for High Wind Applications Under <br />the 2012 IBC and IRC (ASCE 7-10). <br />4.4.3 2009 IBC and IRC: For basic wind speeds <br />(3-second gust) of 100 mph (161 (kmh) or less and mean <br />roof heights of 60 feet (18 288 mm) or less for the IBC or <br />40 feet (12 192 mm) or less for the IRC, tiles must be <br />installed in accordance with the prescriptive parameters of <br />Table 1507.3.7 of the IBC or Section R905.3.7 of the IRC, <br />as applicable. For applications beyond these prescriptive <br />parameters, the tiles and the fastening systems must <br />be designed to withstand the aerodynamic wind uplift <br />moment in accordance with the section on Design <br />Considerations for High Wind Applications in Appendix B <br />of the TRI/WSRCA installation manual (ESR-2015P). The <br />generic required aerodynamic uplift moment, determined in <br />accordance with Tables 5A through 6D of the TRI/WSRCA <br />installation manual, must be multiplied by the tile factor <br />ratio in Table 2 of this report to obtain the required <br />aerodynamic uplift moment for the specific roof tile being <br />installed. The allowable aerodynamic uplift moment for the <br />roof tile fastening system selected from Table 7A of the <br />TRI/WSRCA installation manual, must be equal to or <br />greater than the required aerodynamic uplift moment for <br />the specific roof tile being installed. <br />4.5 Reroofing: <br />Eagle® and Eaglelite® tiles may be installed over existing <br />asphalt shingles, provided the requirements set forth in <br />IBC Section 1510 or IRC Section R907, as applicable, are <br />met. Damaged or rusted flashing must be replaced. <br />Existing framing must be adequate for the additional load. <br />Structural data verifying adequacy must be submitted to <br />the code official. The existing roof must be inspected in <br />accordance with the requirements of the applicable code. <br />The roof classification is as noted in Section 4.3. <br />When reroofing wood shake roofs, existing shakes must <br />be removed and solid decking and tile must be installed, <br />as with new construction. When installation is over <br />existing spaced sheathing boards, underlayment <br />complying with the requirements of the applicable code or <br />an underlayment recognized specifically for this type of use <br />in an ICC-ES evaluation report, installed with or without <br />battens, may be used. One layer of ASTM D226, Type II <br />(No. 30) felt or approved equivalent underlayment must be <br />installed on the roof prior to application of tile. Details not <br />covered under this section are identical to those described <br />in Section 4.1. <br />5.0 CONDITIONS OF USE <br />The Eagle® and Eaglelite® concrete roof tiles described in <br />this report comply with, or are suitable alternatives to what <br />is specified in, those codes listed in Section 1.0 of this <br />report, subject to the following conditions: <br />5.1 The roof tiles must be installed in accordance with this <br />report, the applicable code and the TRI/WSRCA <br />installation manual (ESR-2015P). In case of a conflict <br />between the installation manual and this report, this <br />report governs. <br />5.2 The roof decking and roof framing system must be <br />designed for the appropriate loads determined in <br />accordance with the applicable code. <br />5.3 The tiles are limited to installation on roofs with a <br />slope of 60 degrees or less from horizontal. <br /> Exception: Installation on roof slopes exceeding 60 <br />degrees from the horizontal require an approved wind <br />clip on the bottom edge of each tile in addition to two <br />fasteners per tile. <br />5.4 The Eagle® and Eaglelite® concrete tiles are produced <br />at the manufacturing facilities specified in Table 1 <br />under a quality control program with inspections by <br />ICC-ES. <br />6.0 EVIDENCE SUBMITTED <br />Data in accordance with the ICC-ES Acceptance Criteria <br />for Clay and Concrete Roof Tiles (AC180), dated February <br />2012. <br />7.0 IDENTIFICATION <br />Each Eagle field tile is imprinted with the EAGLE logo <br />(see Figure 2). Tiles produced at the Sumterville, Florida, <br />plant have the EAGLE logo and “FLORIDA” (see Figure 3) <br />imprinted on each field tile. Each Eaglelite tile is identified <br />by the product name “Eaglelite” on a tag and a light- <br />colored strip across the headlap area. Each shipping pallet <br />must have a label bearing the Eagle Roofing Products <br />name; the tile designation; manufacturing location and <br />address; color; quantity of tiles per pallet; production date; <br />installed weight; and the evaluation report number <br />(ESR-1900). <br /> <br /> <br /> <br /> <br /> <br />302 E Santa Clara Ave <br />9/25/2024
The URL can be used to link to this page
Your browser does not support the video tag.