My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2130 N Grand Ave - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Grand Ave
>
2130 N Grand Ave
>
2130 N Grand Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:34:34 AM
Creation date
6/5/2025 7:34:17 AM
Metadata
Fields
Template:
Plan
Permit Number
20182937
101119452
Full Address
2130 N Grand Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1-1-1 <br />1-1-2 <br />1-2-1 <br />1-2-2 <br />1-3-2 <br />1-3-3 <br />1-3-1 <br />INV AC <br />REVISION <br />REV DATE DESCRIPTION <br />A 9/11/2024 PERMIT PLANS <br />DATE: 9/11/2024 <br />DRAFTED BY: PRIYANGA <br />CHECKED BY: JOHN <br />NAME: VIETNAMESE ALLIANCE CHURCH OF ORANGE <br />PROJECT NO: 2308-02 <br />ADDRESS: 2130 N GRAND AVE, SANTA ANA, CA 92705. <br />COORDINATES: 33.764726, -117.852604 <br />APN: 396-191-44 <br />AHJ: CITY OF SANTA ANA <br />UTILITY: SCE <br />58.85kW DC (STC) SYSTEM, 55.16kW DC (PTC) VALUE, <br />50.00kW AC (NAMEPLATE) SYSTEM, 54.34 kW AC (CEC) VALUE <br />MODULES: (107) ZNSHINE SOLAR ZXM7-SHLD144-550W <br />INVERTER(S): (1) CHINT CPS SCA50KTL-DO/US-480 <br />MLPE: (56) AP SMART RSD-D-20 <br />PAGE NO: E-1.0 <br />PROJECT INFORMATIONSYSTEM INFORMATIONCONTRACTOR INFORMATION <br />THE INFORMATION CONTAINED IN THIS DRAWING IS PROPRIETARY AND <br />CONFIDENTIAL AND SHALL ONLY BE USED FOR THE PURPOSES OF THIS <br />PROJECT. <br />ELECTRICAL <br />STRINGING LAYOUT <br />SCALE: 1/8"=1'-0" <br />NEGATIVE <br />TERMINAL <br />POSITIVE <br />TERMINAL <br />NO. OF INVERTER <br />NO.OF STRING <br />NO. OF MPPT <br />1 - 1 - 1 <br />MIDPOINT OF <br />STRING <br />WIRING "LOOP <br />BACK"POINT. <br />NOTE: <br />WIRING AND WIRING METHODS: <br />1. EXPOSED PV SOLAR MODULE WIRING AND PV SOURCE CIRCUITS TO BE UV RESISTANT <br />1,000V PV WIRE, 90° C, AND RATED FOR WET CONDITIONS. <br />2. ALL EXPOSED CABLES, SUCH AS MODULE LEADS SHALL BE SECURED IN A NEAT <br />WORKMAN LIKE MANNER TO PREVENT CHAFFING, SWINGING, AND EXCEEDING MINIMUM <br />BEND RADIUS WITH PROPER MECHANICAL SUNLIGHT RESISTANT MEANS AND ROUTED <br />TO AVOID DIRECT EXPOSURE TO SUNLIGHT AT ALL TIMES. <br />3. ALL FIELD WIRING THAT IS NOT COLOR CODED SHALL BE TAGGED AT BOTH ENDS WITH <br />PERMANENT WIRE MARKERS TO IDENTIFY POLARITY AND GROUND. <br />4. FLEXIBLE METAL CONDUIT IS SUITABLE FOR INSTALLATION OF AC CONDUCTORS IN DRY <br />LOCATIONS. SHOULD IT BE EMPLOYED, SUPPORTS WILL BE NO MORE THAN 12 INCHES <br />FROM BOXES (JUNCTION BOX, CABINETS OR CONDUIT FITTING) AND NO MORE THAN 48 <br />INCHES APART. <br />5. LIQUID TIGHT FLEXIBLE METAL AND NON-METALLIC CONDUIT IS SUITABLE FOR <br />INSTALLATION IN WET AND DRY LOCATIONS. SHOULD IT BE EMPLOYED, SUPPORTS <br />WILL BE NO MORE THAN 12 INCHES FROM BOXES (JUNCTION BOX, CABINETS, OR <br />CONDUIT FITTING) AND NO MORE THAN 36 INCHES APART. <br />6. PVC CONDUIT AND FITTINGS SHALL NOT BE USED ON ROOFTOP CONDITIONS OR <br />EXPOSED TO DIRECT SUNLIGHT.WHEN USED IN ACCEPTABLE LOCATION CONDUIT <br />SHALL BE SCHEDULE 80 UV RESISTANT UNLESS NOTED OTHERWISE. <br />7. FUSES AND WIRES SUBJECT TO TEMPERATURES CONDITIONS GREATER THAN 100°F OR <br />TRANSFORMER INRUSH CURRENT SHALL BE SIZED ACCORDINGLY. <br />8. THE PHOTOVOLTAIC SOURCE CIRCUITS AND PHOTOVOLTAIC OUTPUT CIRCUITS OF THIS <br />PROPOSED SOLAR SYSTEM SHALL NOT BE CONTAINED IN THE SAME RACEWAY CABLE <br />TRAY, CABLE, OUTLET BOX, JUNCTION BOX, OR SIMILAR FITTING AS FEEDERS OR <br />BRANCH CIRCUITS OF OTHER SYSTEMS UNLESS THE CONDUCTORS OF THE DIFFERENT <br />SYSTEMS ARE SEPARATED BY A PARTITION OR ARE CONNECTED TOGETHER. <br />9. ALL TERMINATIONS SHALL HAVE ANTI-OXIDANT COMPOUND AND BE TORQUED PER <br />DEVICE LISTING, OR MANUFACTURER'S RECOMMENDATIONS. 10. SPLIT BOLTS /SPLICES <br />/ CONNECTORS ARE PERMITTED ON THE AC CONDUCTORS AND SHALL BE INSULATED <br />WITH APPROVED MEANS. SPLICES ON THE DC CONDUCTORS IS NOT PERMITTED IN ANY <br />LOCATION. <br />11.NO PVC CONDUIT ALLOWED ON ROOF, UNLESS OPEN ENDED WIRE MANAGEMENT <10'. <br />ELECTRICAL STRINGING LAYOUT : <br />STRING QTY. <br />1-1-1 16 <br />1-1-2 16 <br />1-2-1 15 <br />1-2-2 15 <br />1-3-1 15 <br />1-3-2 15 <br />1-3-3 15 <br />PHOTOVOLTAIC ARRAY ON ROOF <br />4' FIRE SETBACK <br />(N) INVERTER <br />(EXTERIOR WALL OF THE BUILDING) <br />(N) UTILITY AC NON FUSED <br />DISCONNECT SWITCH-2(DH363URK), <br />(24/7 UTILITY ACCESSIBLE) <br />(EXTERIOR WALL OF THE BUILDING) <br />N <br />S <br />EW <br />2130 N Grand Ave <br />10/1/2024
The URL can be used to link to this page
Your browser does not support the video tag.