Laserfiche WebLink
<br />Vietnamese Alliance Church PV Orie2 Engineering <br />Santa Ana, CA February 14th, 2024 <br />2 <br /> <br />3.0 EXISTING STRUCTURES  <br />  <br />1) Alliance Church  <br />This building consists of a roof at a height of 31’‐0” with Spray on foam built up roofing on rigid  <br />insulation over ½” plywood decking. The plywood deck spans across TJI joists that are supported by  <br />glulam girder beams. The structure is approximately 71’‐6” wide by 105’‐6” long with wood stud walls.   <br />  <br />  <br />4.0 PHOTOVOLTAIC PANEL RACKING SYSTEM & COMPONENTS  <br />  <br />The racking system utilizes PanelClaw’s FR10 racking system. The solar module, racking, & racking components  <br />are designed and verified by PanelClaw’s engineering team. Please refer to the PanelClaw drawings for  <br />information on ballast block & attachment quantities and locations. Orie2 has coordinated with the racking  <br />company by providing the mechanical attachment capacity for anchorage to the existing roof of the structure.  <br />See Table 1 below for a summary of the PV array weights, maximum localized array distributed load, and  <br />quantity of modules. The table provides our recommendations on the PV system size (to meet structural  <br />constraints only, sizing for space and electrical constraints may be less), and weight limitations based on our  <br />analysis. Note that the values in the table are from the racking company submittal and is for reference only.  <br />  <br /> Table 1: Photovoltaic Panel System Summary  <br />Building Structure Amazon Fresno (DSJ5)  <br />PV System Weight 13,841 lbs     <br />Number of PV Modules 107 modules     <br />Max Array Distributed Load 3.75 psf  <br />*The quantity of modules will be limited due to the area of the roof that is available for solar, the   <br />quantity shown here is based solely on seismic mass/structural constraints.  <br />  <br />  <br />5.0 FINDINGS, RECOMMENDATIONS, & POTENTIAL DESIGN CHALLENGES  <br />  <br />Based on our review of the as‐built roof framing plans, it is our professional opinion that the existing roof  <br />framing members and structural elements are okay to support the weight and imposed loading from the  <br />addition of the photovoltaic panel system & its racking components. The existing roof framing has been  <br />checked for a maximum solar dead load of 5.0 psf (actual max array distributed load is shown in table 1), and  <br />we determined that the PV system is okay to be installed on the existing structure. It is recommended that the  <br />distributed array weight of the PV system be limited to 5 psf max.   <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />2130 N Grand Ave <br />10/1/2024