My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
214 W Alton Ave - Plan
PBA
>
Building
>
ProjectDox
>
A
>
Alton Ave
>
214 W Alton Ave
>
214 W Alton Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:34:34 AM
Creation date
6/5/2025 7:34:17 AM
Metadata
Fields
Template:
Plan
Permit Number
20183957
101120794
Full Address
214 W Alton Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
125
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PV 2 <br />TED BAKER <br />C10 & C46 <br />LIC# 858088 <br />PH <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br /> <br />S <br />I <br />Z <br />E <br />: <br />7. <br />2 <br />3 <br />0 <br /> <br />k <br />W <br />AP <br />N <br />: <br /> <br />41 <br />0 <br />- <br />2 <br />8 <br />2 <br />- <br />2 <br />0 <br />21 <br />2 <br />0 <br /> <br />H <br />A <br />R <br />M <br />O <br />N <br />Y <br /> <br />G <br />R <br />O <br />V <br />E <br /> <br />R <br />D <br />ES <br />C <br />O <br />N <br />D <br />I <br />D <br />O <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />0 <br />2 <br />9 <br />PH <br />O <br />N <br />E <br /> <br />( <br />8 <br />7 <br />7 <br />) <br /> <br />5 <br />7 <br />8 <br />- <br />8 <br />0 <br />8 <br />0 <br />21 <br />4 <br /> <br />W <br /> <br />A <br />L <br />T <br />O <br />N <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />CM <br />06/17/2024DATE: <br />DRAWN BY: <br />JOB NO: <br />SINGLE LINE <br />DIAGRAM <br />REVISIONS: <br />LICENSED PROFESSIONAL <br />S45017 <br />EXP. 4/30/2025 <br />EN <br />E <br />R <br />G <br />Y <br /> <br />S <br />T <br />O <br />R <br />A <br />G <br />E <br /> <br />S <br />I <br />Z <br />E <br />: <br />5 <br />k <br />W <br /> <br />/ <br /> <br />1 <br />3 <br />. <br />5 <br /> <br />k <br />W <br />h <br />NEW 125A SOLAR READY <br />PANEL & METER <br />SERIAL # MBED2040PV 125A <br />BF OR EQUIVALENT <br />(NOT CENTER FED) <br />UPGRADED FROM 100A <br />SEE ATTACHED SPEC SHEET <br />(N) 125A MAIN BREAKER <br />(SOLAR READY PANEL) <br />225A BUS RATING <br />Gi <br />b <br />b <br />s <br /> <br /> Re <br />s <br />i <br />d <br />e <br />n <br />c <br />e <br />EXISTING UFER IDENTIFIED <br />PER NEC SECTION 250.52(A)(3) <br />(SEE ELECTRICAL NOTE #7) <br />M <br />(N) 60A PV / ESS BREAKER <br />(SEE NOTE #1 FOR LOCATION; <br />SEE NOTE #2 FOR SHUT DOWN) <br />(N) TESLA <br />AC POWERWALL 3 <br />#1707000-XX-Y <br />11.5kW / 13.5 kWH, <br />NEMA 3R <br />(OUTSIDE WALL) <br />PROVIDE ARRAY <br />JUNCTION BOX <br />ON ROOF (AS <br />REQUIRED) <br />A <br />TESLA BATTERY <br />TESLA INVERTER <br />INTEGRATED <br />CT <br />R <br />L <br />. <br />. <br /> <br />. <br />. <br />. <br /> <br />. <br />HANWHA MODULES <br />Q.TRON BLK M-G2+ 425 <br />MODULE(s) <br />(9x) MODULES PER BRANCH <br />(2x) AWG #10 (PVWIRE) PER STRING <br />& (1x) #6 BARE COPPER GROUND <br />SEE NOTE # 5 <br />SOLAR SHUTDOWN DEVICE <br />(3x) MCI-1 PER BRANCH CIRCUIT <br />INTEGRATED DC ISOLATED GROUND <br />HANWHA MODULES <br />Q.TRON BLK M-G2+ 425 <br />MODULE(s) <br />(8x) MODULES PER BRANCH <br />SOLAR SHUTDOWN DEVICE <br />(3x) MCI-1 PER BRANCH CIRCUIT <br />INTEGRATED DC ISOLATED GROUND <br />ELECTRICAL NOTES: <br />TAG <br />A <br />B <br />DESCRIPTION & <br />CONDUCTOR TYPE <br />CONDUCTOR <br />SIZE <br />NUMBER OF <br />CONDUCTORS <br />CONDUIT/CONDUCTOR/ <br />CABLE TYPE <br />CONDUIT <br />SIZE <br />CURRENT-CARRYING <br />CONDUCTORS: (FOR <br />EACH BRANCH CIRCUIT) <br />EGC <br />EGC <br />CURRENT-CARRYING <br />CONDUCTORS: (FOR <br />EACH BRANCH CIRCUIT) <br />10 <br />10 <br />2x <br />1x <br />6 OR 4 <br />10 <br />3x <br />1x <br />3/4" <br />1" <br />EMT <br />EMT OR ROMEX <br />CONDUIT & WIRING SCHEDULE <br />OCPD <br />60A <br />TERMINALS ARE RATED AT THE 75°C COLUMN FOR EMT <br /> TERMINALS ARE RATED AT THE 60°C COLUMN FOR ROMEX <br /> AS PER NEC 310.15 FOR TEMPERATURE RATING OF <br /> CONDUCTOR <br />C <br />EGC <br />CURRENT-CARRYING <br />CONDUCTORS: (FOR <br />EACH BRANCH CIRCUIT) <br />18 2x <br />3/4"EMT OR ROMEX <br />D <br />EGC <br />CURRENT-CARRYING <br />CONDUCTORS: (FOR <br />EACH BRANCH CIRCUIT) <br />16 2x <br />3/4"EMT OR ROMEX <br />1.THE PHOTOVOLTAIC CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT <br />LOCATION PER CEC ART. 690.64 WHEN USING THE 120% OF RATING ALLOWANCE FOR DETERMINING THE TOTAL RATING OF OVER CURRENT DEVICE AS PER 705.12(B)(3)(2). <br />A CONNECTION AT EITHER END, BUT NOT BOTH ENDS, OF A CENTER-FED PANEL BOARD IN DWELLINGS SHALL BE PERMITTED WHERE THE SUM OF 125 PERCENT OF THE <br />POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR DOES NOT EXCEED 120 PERCENT OF THE CURRENT <br />RATING OF THE BUSBAR AS PER 705.12(B)(3)(4). <br />2.SOLAR CIRCUIT BREAKERS SHALL BE SUITABLE FOR BACKFEED AND WILL SERVE AS RAPID SHUTDOWN DEVICES AT MSP. (CIRCUIT BREAKERS THAT ARE MARKED "LINE" <br />AND "LOAD" ARE NOT SUITABLE FOR BACKFEED.) <br />3.LABELS ARE REQUIRED ON ALL INTERIOR AND EXTERIOR PHOTOVOLTAIC DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES. LABEL SHALL READ "WARNING: <br />PHOTOVOLTAIC POWER SOURCE" WITH A RED BACKGROUND, WHITE LETTERING, MINIMUM 3/8" LETTER HEIGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, <br />NON-BOLD, AND ON A RED BACKGROUND. THE MATERIALS USED SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. LABEL SHALL BE <br />LOCATED AT EVERY 10 FEET OF CONDUIT, WITHIN 1' OF TURNS OR BENDS, WITHIN 1' ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS, OR <br />BARRIERS AND AT ALL PV COMBINER AND JUNCTION BOXES. <br />4.IDENTIFICATION FOR UNGROUNDED CONDUCTORS OF BRANCH CIRCUITS SUPPLIED FROM DIRECT-CURRENT SYSTEMS SHALL COMPLY WITH 210.5(C)(2)(a) AND (b). <br />IDENTIFICATION AND GROUPING OF PHOTOVOLTAIC DC CIRCUITS SHALL COMPLY WITH NEC 690.31(B) AND SHALL BE SEPARATED FROM OTHER NON PV SYSTEM <br />CONDUCTORS. PHOTOVOLTAIC SYSTEM GROUNDING COMPLIES WITH 690.41 & 690.45. <br />5.AUXILIARY GROUNDING IS PROVIDED FOR THE MOUNTING RAILS AT EACH ROW UTILIZING THE BURNDY WEEB-LUG 8.0 (UL 2703) AS PER CEC 690.47. PHOTOVOLTAIC <br />SYSTEM GROUNDING COMPLIES WITH 690.41 & 690.45. EXPOSED NON-CURRENT CARRYING METAL PARTS OF PHOTOVOLTAIC RACKING, EQUIPMENT, AND CONDUCTOR <br />ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE TO NEC 690.47, 250.64(C), 250.66, & 250.134 OR 250.136(A), AND SIZED PER 250.166 REGARDLESS OF VOLTAGE. THE <br />GEC / EGC SHALL BE CONTINUOUS, OR WHEN SPLICED, THE SPLICE SHALL BE MADE BY IRREVERSIBLE CRIMP PER NEC 250.64 (C) <br />6.EACH MODULE SHALL BE GROUNDED PER THE MANUFACTURER'S INSTRUCTIONS USING THE INTEGRATED BONDING MIDCLAMP / COMPONENTS (SEE SOLAR MOUNT SPEC <br />SHEET), AND AT EACH ROW UTILIZING THE SUPPLIED GROUND LUG (UL 2703). SEE GROUNDING LUG SPEC SHEET. <br />7.IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED, OR IS ONLY METALLIC WATER PIPING, OR IT HAS A RESISTANCE GREATER THAN 25 OHMS, IT IS <br />THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE AT LEAST 6' FROM THE EXISTING GROUNDING ELECTRODE. GROUNDING <br />ELECTRODE CONDUCTOR SHALL BE SIZED PER CEC 250.66. <br />8.ELECTRICAL EQUIPMENT INSTALLED SHALL BE LISTED, LABELED, OR CERTIFIED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL). <br />9.ALL SERVICES SUPPLYING DWELLING UNITS SHALL BE PROVIDED WITH A SURGE-PROTECTIVE DEVICE (SPD) AT THE MAIN SERVICE PANEL PER 230.67 OF THE 2022 CEC. <br />10.INVERTER IS NEC 690.12 RAPID SHUTDOWN COMPLIANT; SEE SPECS. UPON TURNING OFF THE INTEGRATED DC DISCONNECT, AND/OR THE INVERTER OCPD AT THE <br />MSP, THE PV CONDUCTORS SHUTDOWN WITHIN 30 SECONDS AS PER NEC 690.12(2) <br />11.THE ENERGY STORAGE DEVICE END OF THE CIRCUIT HAS AN OVERCURRENT DEVICE FOR DISCONNECTING MEANS PER 690.71(H)(1) AND IS WITHIN SIGHT OF THE PV <br />SYSTEM AC AND DC DISCONNECTING MEANS AS PER 690.71(H)(5) ; SINCE BOTH ARE INTERCONNECTED AT THE CRITICAL LOADS SUB PANEL. A SECOND DISCONNECTING <br />MEANS ADJACENT TO THE MSP SHALL BE INSTALLED IF THE ENERGY STORAGE DEVICE IS IN THE GARAGE AND / OR NOT WITHIN VIEW OF THE MSP CONNECTED <br />EQUIPMENT AS PER 690.71(H)(4). <br />(N) TESLA <br />GATEWAY 2.0 <br />200A, NEMA 3R WITH <br />INTERNAL PANELBOARD <br />CT <br />R <br />L <br /> <br />NON-BACKUPBACKUP <br />(N) 100A / 240V <br />BREAKER <br />(N) 15A / 240V <br />BREAKER FOR <br />NEURIO <br />(N) ENERGY <br />STORAGE <br />EMERGENCY SHUT <br />OFF DISCONNECT <br />ADJACENT TO MSP <br />D <br />(N) 100A / 240V <br />BREAKER <br /> (N) 200A PROTECTED <br />LOADS SUB PANEL <br />(OUTSIDE WALL) <br />RELOCATED <br />HOUSE CIRCUITS NOT <br />TO EXCEED 100A / 240V <br />(N) 100A / 240V <br />BREAKER <br />E <br />EGC <br />CURRENT-CARRYING <br />CONDUCTORS: (FOR <br />EACH BRANCH CIRCUIT) <br />1-1/4" <br />OR <br />1-1/2'' <br />EMT OR ROMEX <br />3 OR 1 <br />6 <br />3x <br />1x <br />100A <br />B <br />E <br />E <br />C <br />RELOCATED CIRCUITS TO <br />PROTECTED LOADS PANEL AMPS <br />WASHER 20/20 <br />DRYER/G. DISP <br />DW/FAU <br />KITCHEN <br />KITCHEN <br />LIGHTS <br />15 <br />20/20 <br />20/20 <br />20/20 <br />20/20 <br />15/15 <br />NOTE: GATEWAY 2 IS LISTED AS PCS & EMS EQUIPMENT <br />1.) PCS LIMIT SET TO: 16AMPS x 125% + MAIN BREAKER (100A)= 120A <br />2.) 120% BUS RATING 100A) = 120A <br />THE VALUE OF 1.) IS LESS THAN OR EQUAL TO 2.) <br />DESIGN IS COMPLIANT SEE NOTE #1 <br />705.12 (B)(2)(3)(b) RULE FOR INTERCONNECTION <br />(N) 240V CIRCUIT <br />EV OUTLET <br />(INSIDE GARAGE) <br />(N) 50A / 240V <br />GFCI BREAKER <br />F <br />EGC <br />CURRENT-CARRYING <br />CONDUCTORS: (FOR <br />EACH BRANCH CIRCUIT)1''EMT OR ROMEX <br />6 1x <br />50A <br />8 OR 6 3x <br />F <br />214 W Alton Ave <br />10/8/2024
The URL can be used to link to this page
Your browser does not support the video tag.