Laserfiche WebLink
WH <br />DryerWasher <br />Re <br />f <br />r <br />i <br />g <br />e <br />r <br />a <br />t <br />o <br />r <br />13 <br />' <br /> <br />- <br /> <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />11 <br />' <br /> <br />- <br /> <br />5 <br />" <br />6' <br /> <br />- <br /> <br />7 <br />" <br />10 <br />' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />22' - 4"11' - 7 1/2"13' - 7 1/2" <br />10 <br />' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />13' - 8 1/2" <br />13' - 1"2' - 6"7' - 5" <br />17 <br />' <br /> <br />- <br /> <br />3 <br />" <br />7' - 5" <br />13' - 5 1/2"13' - 5 1/2" <br />LIVING <br />DINING <br />KITCHEN <br />BED <br />BATH <br />LIVING #2 <br />BED BED <br />HALLWAY <br />HALLWAY <br />BATH <br />CLOSET <br />CL <br />O <br />S <br />E <br />T <br />CL <br />O <br />S <br />E <br />T <br />CL <br />O <br />S <br />E <br />T <br />EXISTING CMU <br />WALL TO REMAIN <br />EXISTING GATE <br />FENCE TO REMAIN <br />EXISTING <br />PERIMETER WALL: <br />6' HIGH MASONRY <br />EXISTING <br />PERIMETER WALL: <br />6' HIGH MASONRY <br />EXISTING WATER <br />HEATER <br />EXISTING WASHER & DRYER <br />4' - 8" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />TOILET CLEARANCE <br />SLAB ELEVATION CHANGE <br />SMOKE DETECTOR <br />CO2 DETECTOR <br />EXHAUST FAN (50 CFM MIN. REQ'D) <br />CLEARANCE IN FRONT OF TOILET <br />SHALL BE 24" DEPTH & 30" WIDTH <br />REFER TO BUILDING ELEVATIONS & SITE PLAN FOR <br />ADDT'L INFORMATION <br />FANS SHALL BE ENERGY STAR COMPLIANT AND BE <br />DUCTED TO TERMINATE TO THE OUTSIDE OF THE <br />BUILDING. FANS, NOT FUNCTIONING AS A COMPONENT <br />OF A WHOLE HOUSE VENTILATION SYSTEM, MUST BE <br />CONTROLLED BY A HUMIDITY CONTROL <br />NEW EXT. WALL -7/AD-1.0 <br />EXISTING WALL <br />CM <br />SD <br />1. NEW PLUMBING FIXTURES AND FITTINGS SHALL NOT EXCEED <br />THE MAXIMUM ALLOWABLE FLOW RATES SPECIFIED IN SECTION <br />5.303.3. <br />2. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, <br />THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS AND/OR <br />OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE <br />SHALL NOT EXCEED 2.0 GALLONS / MINUTE AT 80 PSI, OR THE <br />SHOWER SHALL BE DESIGNED TO ONLY ALLOW ONE <br />SHOWERHEAD TO BE IN OPERATION AT A TIME. <br />3. A FINAL REPORT FOR THE RESTING AND ADJUSTING OF ALL NEW <br />SYSTEMS SHALL BE COMPLETED PRIOR TO FINAL APPROVAL BY <br />THE FIELD INSPECTOR. THIS REPORT SHALL BE SIGNED BY THE <br />INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES. <br />4. AN OPERATION & SYSTEMS MANUAL, SHALL BE PROVIDED TO <br />THE OWNER OR REPRESENTATIVE AND TO THE FIELD INSPECTOR <br />AT THE TIME OF THE FINAL INSPECTION. <br />5. IF THE NEW HVAC SYSTEM IS USED DURING CONSTRUCTION, USE <br />RETURN AIR FILTERS WITH A MERV OF 8. REPLACE ALL FILTERS <br />IMMEDIATELY PRIOR TO OCCUPANCY. <br />6. ALL DUCT AND OTHER RELATED AIR DISTRUBTION COMPONENT <br />OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC OR SHEET <br />METAL UNTIL THE FINAL STARTUP OF THE HEATING, COOLING <br />AND VENTILATION EQUIPMENT. <br />7. ARCHITECTURAL PAINTS AND COATINGS, ADHESIVES, CAULKS <br />AND SEALANTS SHALL COMPLY WITH THE VOLATIVE ORGANIC <br />COMPOUND LIMITS LISTED IN TABLES 5.04.41-5.504.4.3. <br />8. THE VOC CONENTENT VERIFICATION CHECKLIST, FORM GRN 2, <br />SHALL BE COMPLTED AND VERIFIED PRIOR TO FINAL INSPECTION <br />APPROVAL.THE MANUFACTURER'S SPECIFICATIONS SHOWING <br />VOC CONTENT FOR ALL APPLICABLE PRODUCTS SHALL BE <br />READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE <br />FIELD INSPECTOR FOR VERIFICATION. <br />9. AN AIR FILTER WITH A MINIMUM EFFICIENCY REPORTING VALVE <br />(MERV) OF 8 OR HIGHER SHALL BE INSTALLED IN THE <br />MECHANICAL SYSTEM FOR OUTSIDE AND RETURN AIR PRIOR TO <br />OCCUPANCY. <br />10. DESIGNATED OUTDOOR SMOKING AREA SHALL BE AT LEAST 25 <br />FEET FROM THE BUILDING ENTRIES, OUTDOOR AIR INTAKES OR <br />OPERABLE WINDOWS. <br />11. THRESHOLDS MUST BE 1/2" MAX. HEIGHT. <br />12. ASSISTED LISTENING DEVICES - 4% MIN. IN CONFERENCE ROOM, <br />BASED ON $ OF SEATS <br />13. DOOR HARDWARE TO COMPLY PER CBC SECTION 11B-404.2.7 & <br />11B-309.4. <br />14. ALL TABLES TO PROVIDE 28-34" CLEAR HEIGHT, KNEE & TOE <br />CLEARNACE OF 27" HEIGHT AND 19-25" DEPTH. PROVIDE A 30" X <br />48: CLEAR FRONT APPROACH. <br />15. ALL FUTURE FURNITURE LAYOUT TO MAINTAIN 36" CLEAR <br />ACCESSIBLE AISLES AT ALL TIMES. <br />*SEE SHEET A-6.1 FOR WALL DETAILS <br />NEW INT. WALL -9/AD-1.0 <br />EXISTING CMU WALL <br />NEW 1-HR FIRE RATED -8/AD-1.0 <br />JOB NO.SCALE <br />AS NOTED <br />SHEET NO. <br />SHEET TITLE. <br />APPROVALS: <br />THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF <br />THE DRAFTER AND MAY NOT BE REPRODUCED WITHOUT THE <br />DESIGNERS PERMISSION AND UNLESS THE REPRODUCTION CARRIES <br />THE DRAFTERS NAME. ALL DESIGN AND OTHER INFORMATION SHOWN <br />ON THE DRAWINGS ARE FOR USE ON THE SPECIFIC PROJECT ONLY <br />AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION <br />FROM THE DRAFTER. <br />[DESIGN GROUP NAME][DESIGN GROUP NAME][DESIGN GROUP NAME][DESIGN GROUP NAME] <br />1610 W. 7TH ST. LOS ANGELES, CA. 90017 <br />benny@designgroupname.com <br />marino@designgroupname.com <br />LEGEND <br />PLAN NOTES <br />KEYNOTES <br />8/ <br />2 <br />7 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />7 <br />: <br />4 <br />3 <br />: <br />5 <br />1 <br /> <br />A <br />M <br />A-0.2 <br />EXISTING <br />RESIDENCE <br />[DGN-2200] <br />1621 w 10th ST. & #2 <br />SANTA ANA, CA. <br />10th ADU <br />No. Description Date <br />1 PLANNING - REV 1 05 06 24 <br />2 PLANNING - REV 1 06 06 24 <br />SCALE <br />1/4" = 1'-0"1(E) FLOOR PLAN <br />1621 W Tenth St & <br />#29/30/2024