GENERAL NOTES <br />100SN001 <br />1. INTERPRETATION OF DRAWINGS & SPECIFICATIONS <br />A. WHERE SPECIFICATIONS HAVE BEEN PREPARED FOR THIS PROJECT, THEY ARE ARRANGED <br />IN SEVERAL SECTIONS, BUT SUCH SEPARATION SHALL NOT BE CONSIDERED AS THE LIMITS <br />OF THE WORK REQUIRED OF ANY SEPARATE TRADE. THE TERMS AND CONDITIONS OF <br />SUCH LIMITATIONS ARE WHOLLY BETWEEN THE CONTRACTOR AND THEIR <br />SUBCONTRACTORS. <br />B. IN GENERAL, THE WORKING DETAILS WILL INDICATE DIMENSIONS, POSITION AND KIND OF <br />CONSTRUCTION, AND THE SPECIFICATIONS, QUALITIES AND METHODS. ANY WORK <br />INDICATED ON THE WORKING DETAILS AND NOT MENTIONED IN THE SPECIFICATIONS, OR <br />VICE VERSA, SHALL BE FURNISHED AS THOUGH FULLY SET FORTH IN BOTH. WORK NOT <br />PARTICULARLY DETAILED, MARKED OR SPECIFIED, SHALL BE IDENTICAL OR SIMILAR TO LIKE <br />CASES OF CONSTRUCTION THAT ARE DETAILED, MARKED OR SPECIFIED. IF CONFLICTS <br />OCCUR ON DRAWINGS AND/OR SPECIFICATIONS, THE MOST EXPENSIVE MATERIALS OR <br />METHODS WILL PREVAIL. <br />C. SHOULD AN ERROR APPEAR IN THE WORKING DETAILS OR SPECIFICATIONS OR IN WORK <br />DONE BY OTHERS AFFECTING THIS WORK, THE CONTRACTOR SHALL NOTIFY THE <br />ARCHITECT AT ONCE AND IN WRITING. IF THE CONTRACTOR PROCEEDS WITH THE WORK <br />SO AFFECTED WITHOUT HAVING GIVEN SUCH WRITTEN NOTICE AND WITHOUT RECEIVING <br />THE NECESSARY APPROVAL, DECISION OR INSTRUCTIONS IN WRITING FROM THE OWNER, <br />THEN THE CONTRACTOR SHALL HAVE NO VALID CLAIM AGAINST THE OWNER, FOR THE <br />COST OF SO PROCEEDING AND SHALL MAKE GOOD ANY RESULTING DAMAGE OR DEFECT. <br />NO VERBAL APPROVAL, DECISION, OR INSTRUCTION SHALL BE VALID OR BE THE BASIS FOR <br />ANY CLAIM AGAINST THE OWNER, ITS OFFICERS, EMPLOYEES OR AGENTS. THE <br />FOREGOING INCLUDES TYPICAL ERRORS IN THE SPECIFICATIONS OR NOTATIONAL ERRORS <br />IN THE WORKING DETAILS WHERE THE INTERPRETATION IS DOUBTFUL OR WHERE THE <br />ERROR IS SUFFICIENTLY APPARENT AS TO PLACE A REASONABLY PRUDENT CONTRACTOR <br />ON NOTICE THAT, SHOULD THE CONTRACTOR ELECT TO PROCEED, THEY ARE DOING SO AT <br />THEIR OWN RISK. <br />2. CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS. <br />3. SHOP DRAWING NOTE: <br />A. WHEN NOT ADDRESSED BY DIVISION 1 OF THE SPECIFICATIONS, SUBMITTALS SHALL BE <br />ELECTRONIC PDF FORMAT. <br />B. THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE <br />TO THE STRUCTURAL ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN <br />CONCEPT BY INDICATING WHICH MATERIAL THE CONTRACTOR INTENDS TO FURNISH AND <br />INSTALL, AND BY DETAILING THE FABRICATION AND INSTALLATION METHODS THE <br />CONTRACTOR INTENDS TO USE ON A STAND ALONE SET OF DOCUMENTS. DUPLICATION OF <br />DESIGN DOCUMENTS FOR THE PURPOSE OF SHOP DRAWINGS IS NOT ACCEPTABLE. <br />C. PRIOR TO FABRICATION, SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW BY THE <br />STRUCTURAL ENGINEER. SHOP DRAWING SUBMITTALS SHALL INCLUDE, BUT ARE NOT <br />NECESSARILY LIMITED TO, STRUCTURAL STEEL, REINFORCING STEEL, & GLUE-LAMINATED <br />BEAMS. <br />D. PRIOR TO SUBMISSION THE CONTRACTOR SHALL REVIEW ALL SUBMITTALS FOR <br />CONFORMANCE WITH THE CONTRACT DOCUMENTS AND SHALL STAMP SUBMITTALS AS <br />BEING "REVIEWED FOR CONFORMANCE". <br />E. SHOP DRAWING SUBMITTALS PROCESSED BY THE STRUCTURAL ENGINEER ARE NOT <br />CHANGE ORDERS. <br />F. ANY DETAIL ON THE SHOP DRAWINGS THAT DEVIATES FROM THE CONTRACT DOCUMENTS <br />SHALL CLEARLY BE MARKED WITH THE NOTE "THIS IS A CHANGE". <br />G. SHOP DRAWINGS OR CALCULATIONS SUBMITTED FOR REVIEW THAT REQUIRE <br />RESUBMITTAL FOR RE-REVIEW SHALL BE BILLED HOURLY FOR SUCH TIME TO THE GENERAL <br />CONTRACTOR. RE-REVIEW WILL NOT PROCEED WITHOUT WRITTEN APPROVAL FROM THE <br />GENERAL CONTRACTOR FOR ADDITIONAL ENGINEERING REVIEW SERVICES. <br />4. SAFETY NOTE: <br />A. IT IS THE CONTRACTORS RESPONSIBILITY TO COMPLY WITH THE PERTINENT SECTIONS, AS <br />THEY APPLY TO THIS PROJECT, OF THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE <br />STATE OF CALIFORNIA LATEST EDITION, AND ALL OSHA REQUIREMENTS. <br />B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE DESIGN AND CONSTRUCTION <br />OF ALL FORMS AND SHORING REQUIRED. SHORING INDICATIONS (LOCATION, DIRECTION, <br />DURATION, ETC.) ARE ONLY SHOWN ON THE STRUCTURAL DWGS WHEN REQUIRED TO <br />IMPLEMENT THE DESIGN INTENT OF THE FINAL WORK PRODUCT. DETERMINATION <br />WHETHER SHORING IS REQUIRED FOR TEMPORARY OR INTERMEDIATE CONDITIONS <br />DURING CONSTRUCTION IS WHOLLY THE RESPONSIBILITY OF THE CONTRACTOR. <br />C. THE OWNER AND THE STRUCTURAL ENGINEER DO NOT ACCEPT ANY RESPONSIBILITY FOR <br />THE CONTRACTOR'S FAILURE TO COMPLY WITH THESE REQUIREMENTS. <br />5. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER WHERE A <br />CONFLICT OR DISCREPANCY OCCURS BETWEEN THE STRUCTURAL DRAWINGS AND ANY <br />OTHER PORTION OF THE CONTRACT DOCUMENTS OR EXISTING FIELD CONDITIONS. SUCH <br />NOTIFICATION SHALL BE GIVEN IN DUE TIME SO AS NOT TO AFFECT THE CONSTRUCTION <br />SCHEDULE. IN CASE OF A CONFLICT BETWEEN STRUCTURAL DRAWINGS AND SPECIFICATIONS <br />THE MORE RESTRICTIVE CONDITION SHALL TAKE PRECEDENCE UNLESS WRITTEN APPROVAL <br />HAS BEEN GIVEN FOR THE LEAST RESTRICTIVE. CONTRACTOR SHALL VERIFY ALL DIMENSIONS <br />WITH ARCHITECTURAL PRIOR TO COMMENCING ANY WORK. <br />6. WHEN CONSTRUCTION ATTACHES TO OR IS WITHIN AN EXISTING BUILDING, A COMPLETE SET <br />OF DRAWINGS OF THE EXISTING BUILDING SHALL BE KEPT ON THE JOB SITE. CONTRACTOR TO <br />OBTAIN THESE DRAWINGS FROM THE OWNER (IF THEY ARE AVAILABLE). <br />7. ANY SUBSTITUTIONS FOR STRUCTURAL MEMBERS, HARDWARE OR DETAILS SHALL BE <br />REVIEWED BY THE ARCHITECT AND STRUCTURAL ENGINEER. SUCH REVIEW WILL BE BILLED <br />ON A TIME AND MATERIALS BASIS TO THE GENERAL CONTRACTOR WITH NO GUARANTEE THAT <br />THE SUBSTITUTION WILL BE ALLOWED. <br />8. DO NOT SCALE DRAWINGS. CONTACT THE ARCHITECT OR STRUCTURAL ENGINEER FOR ANY <br />DIMENSIONS NOT SHOWN. <br />9. THESE DRAWINGS ARE NOT COMPLETE UNTIL REVIEWED AND ACCEPTED BY LOCAL BUILDING <br />OFFICIALS AND THE OWNER AND SIGNED BY THE STRUCTURAL ENGINEER. <br />POST-INSTALLED ANCHORS <br />305SN001 <br />1. FOR CONCRETE CONSTRUCTION, POST-INSTALLED ANCHORS SHALL BE ONE OF THE <br />FOLLOWING: <br />A. ADHESIVE ANCHORS FOR THRD ROD & REBAR: <br />a. HILTI HIT-HY 200 V3 PER ESR-4868 <br />b. HILTI HIT-RE500 V3 PER ESR-3814 <br />c. SIMPSON SET-3G PER ESR-4057 <br />d. DEWALT PURE 110+ ESR-3298 <br />B. EXPANSION ANCHORS: <br />a. HILTI KB-TZ2 PER ESR-4266 <br />b. SIMPSON STRONG BOLT 2 PER ESR-3037 <br />c. DEWALT POWER-STUD+ SD2, SD4 OR SD6 AS NOTED PER ESR-2502 <br />C. SCREW ANCHORS: <br />a. HILTI KWIK HUS-EZ (KH-EZ) PER ESR-3027 <br />b. SIMPSON TITEN HD PER ESR-2713 <br />c. DEWALT SCREWBOLT+ PER ESR-3889 <br />2. ANCHOR TYPE, SIZE & EMBEDMENT SHALL BE AS INDICATED IN DRAWINGS. POST-INSTALLED <br />ANCHORS FOR REPAIR SHALL BE EVALUATED ON A CASE BY CASE BASIS. NOTIFY STRUCTURAL <br />ENGINEER FOR REPAIRS. <br />3. ALL EMBEDMENT DEPTHS CALLED OUT IN DRAWINGS REFER TO EFFECTIVE EMBEDMENT <br />UNLESS OTHERWISE NOTED. SEE DIAGRAM BELOW AND ICC REPORTS. <br />4. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS GIVEN IN THE <br />EVALUATION REPORT. PROVIDE MINIMUM EMBEDMENT PROVIDED IN ICC ESR REPORT UNLESS <br />NOTED OTHERWISE. <br />5. PROVIDE SPECIAL INSPECTION AS INDICATED IN THE STATEMENT OF STRUCTURAL SPECIAL <br />INSPECTIONS AND TESTING AND THE EVALUATION REPORT. <br />6. WHEN INSTALLING POST-INSTALLED ANCHORS IN EXISTING CONCRETE OR MASONRY, USE <br />CARE AND CAUTION TO AVOID CUTTING OR DAMAGING EXISTING REINFORCING BARS. <br />7. ANCHORS INSTALLED FROM THE BOTTOM INTO METAL DECK WITH CONCRETE SHALL BE <br />INSTALLED IN THE CENTER OF THE LOW FLUTE OF THE DECKING UNLESS NOTED OTHERWISE <br />IN EVALUATION REPORT. THE DECKING SHALL HAVE A MINIMUM THICKNESS OF 20 GAUGE. <br />THE MINIMUM THICKNESS OF THE CONCRETE ABOVE THE HIGH FLUTE OF THE METAL DECK <br />SHALL BE AS INDICATED IN THE EVALUATION REPORT. SEE EVALUATION REPORT FOR <br />ADDITIONAL REQUIREMENTS, INCLUDING MINIMUM DIMENSIONS FOR FLUTE WIDTH AND DEPTH. <br />8. THE CONCRETE SHALL HAVE ATTAINED ITS MINIMUM DESIGN STRENGTH PRIOR TO <br />INSTALLATION OF THE ANCHORS. <br />9. ADHESIVE ANCHORS SHALL BE INSTALLED IN CONCRETE HAVING A MINIMUM AGE OF 21 DAYS <br />AT THE TIME OF ANCHOR INSTALLATION PER ACI 318, CHAPTER 17. <br />10. INSTALLER CERTIFICATION AND INSPECTION IS REQUIRED FOR HORIZONTAL AND UPWARDLY <br />INCLINED ADHESIVE ANCHORS SUBJECTED TO SUSTAINED TENSION LOADING IN ACCORDANCE <br />WITH ACI 318, CHAPTER 17. <br />11. IF TEMPERATURE OF BASE MATERIAL AT TIME OF ADHESIVE ANCHOR INSTALLATION IS 45 <br />DEGREES FARENHEIT OR LOWER, AN "ACRYLIC" OR COLD WEATHER ADHESIVE IS REQUIRED. <br />USE DEWALT AC200+, SIMPSON AT-XP, OR HILTI HIT-HY200 WHEN THIS OCCURS. <br />12. THE INSPECTION OF THE ANCHORS SHALL BE DONE BY A QUALIFIED INSPECTION AGENCY AND <br />A REPORT OF THE INSPECTION RESULTS SHALL BE SUBMITTED TO THE GOVERNING AGENCY <br />AND ARCHITECT/STRUCTURAL ENGINEER. <br />INSTALLED ANCHOR DIAGRAMS <br />EM <br />B <br />E <br />D <br />EF <br />F <br />E <br />C <br />T <br />I <br />V <br />E <br />EM <br />B <br />E <br />D <br />NO <br />M <br />I <br />N <br />A <br />L <br />PE <br />R <br /> <br />R <br />E <br />P <br />O <br />R <br />T <br />HO <br />L <br />E <br /> <br />D <br />E <br />P <br />T <br />H <br />EM <br />B <br />E <br />D <br />EF <br />F <br />E <br />C <br />T <br />I <br />V <br />E <br />EM <br />B <br />E <br />D <br />NO <br />M <br />I <br />N <br />A <br />L <br />PE <br />R <br /> <br />R <br />E <br />P <br />O <br />R <br />T <br />HO <br />L <br />E <br /> <br />D <br />E <br />P <br />T <br />H <br />EXPANSION ANCHOR SCREW ANCHOR <br />CONCRETE <br />300SN001 <br />1. CONCRETE SHALL ATTAIN 28 DAY COMPRESSIVE STRENGTH AS REQUIRED IN NOTE #28. <br />SLUMP SHALL BE 4 INCHES ± 1 INCH WITHOUT ADMIXTURES UNLESS NOTED OTHERWISE IN THE <br />SPECIFICATIONS. <br />2. CONCRETE MIX DESIGNS SHALL BE PREPARED ACCORDING TO ACI 318 CHAPTER 26.4 AND <br />ACI 301 SECTION 4, REVIEWED BY OWNER'S TESTING LABORATORY AND SUBMITTED TO THE <br />STRUCTURAL ENGINEER FOR REVIEW. <br />3. CEMENTITIOUS MATERIALS: <br />CEMENT SHALL CONFORM TO ASTM C-150 TYPE II OR V. <br />FLY ASH SHALL CONFORM TO ASTM C-618. MAX. QUANTITY OF FLY ASH BY MASS SHALL BE 25% <br />UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS. <br />SLAG SHALL CONFORM TO ASTM C989. MAX. QUANTITY OF SLAG BY MASS SHALL BE 25% <br />UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS. <br />TERNARY SYSTEMS ARE PROHIBITED. <br />4. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C-33 FOR NORMAL WEIGHT CONCRETE <br />AND ASTM C-330 FOR LIGHTWEIGHT CONCRETE. <br />5. NON-SHRINK GROUT OR DRYPACK SHALL CONSIST OF A PREMIXED NONMETALLIC FORMULA. <br />6. REINFORCING STEEL SHALL CONFORM TO ASTM A-615 GRADE 60 UNO. REINFORCING STEEL <br />TO BE WELDED SHALL CONFORM TO ASTM A-706 GRADE 60. CONTRACTOR SHALL SUBMIT <br />REBAR MILL CERTIFICATES. REINFORCING STEEL IN SPECIAL REINFORCED SHEAR WALLS OR <br />MOMENT FRAMES, EXCEPT TIES AND HOOPS, SHALL CONFORM TO ASTM A-706. <br />7. ALL PREHEATING AND WELDING OF REINFORCING BARS SHALL BE DONE IN ACCORDANCE WITH <br />AWS D1.4 LATEST EDITION AND SHALL BE CONTINUOUSLY INSPECTED BY A QUALIFIED <br />LABORATORY. CONTRACTOR SHALL FURNISH WPS FOR ALL REBAR WELDING TO THE <br />LABORATORY. <br />8. REINFORCING STEEL SHALL BE FABRICATED ACCORDING TO "MANUAL OF STANDARD <br />PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION". <br />9. WIRE FABRIC SHALL CONFORM TO ASTM A1064. <br />10. DIMENSIONS SHOWN FOR LOCATION OF REINFORCING ARE TO THE FACE OF BARS LISTED AND <br />DENOTE CLEAR COVERAGE. NON-PRESTRESSED, CAST-IN-PLACE CONCRETE COVERAGE <br />SHALL BE AS FOLLOWS, UNO: <br />CONCRETE DEPOSITED DIRECTLY AGAINST GROUND (EXCEPT SLABS)--------- 3" <br />CONCRETE EXPOSED TO GROUND OR WEATHER BUT PLACED IN FORMS: <br />#5 AND SMALLER-------------------------------------------------------------------------- 1-1/2" <br />#6 AND LARGER--------------------------------------------------------------------------- 2" <br />BEAMS & COLUMNS (TIES)------------------------------------------------------------------------- 1-1/2" <br />BEAMS & COLUMNS (MAIN REINFORCING)-------------------------------------------------- 2" <br />CAST-IN-PLACE WALLS (EXTERIOR FACE & SOIL SIDE)-------------------------------- SEE ABOVE <br />CAST-IN-PLACE WALLS (INTERIOR FACE-#11 & SMALLER)--------------------------- 3/4" <br />TILT-UP WALLS--------------------------------------------------------------------------------------- SEE DETAILS <br />SLABS (ON FORMS)--------------------------------------------------------------------------------- 3/4" <br />SLABS (ON GROUND)------------------------------------------------------------------------------- 2" CLEAR FROM <br /> TOP <br />11. SPLICES IN CONTINUOUS REINFORCEMENT SHALL BE LAPPED UNO, SEE SCHEDULE THIS <br />SHEET. SPLICES IN ADJACENT BARS SHALL BE GREATER THAN 5'-0" APART. SPLICE <br />CONTINUOUS BARS IN SOIL-BEARING GRADE BEAMS, STRUCTURAL SLABS ON GRADE AND MAT <br />FOUNDATIONS AS FOLLOWS UNO: TOP BARS AT CENTERLINE OF SUPPORT; BOTTOM BARS AT <br />MID-SPAN. SPLICE CONTINUOUS BARS IN ELEVATED SLABS AND BEAMS, ETC. AS FOLLOWS <br />UNO: TOP BARS AT MID-SPAN; BOTTOM BARS AT CENTERLINE OF SUPPORT. ALL BARS SIZE #14 <br />AND LARGER SHALL BE CONTINUOUS FOR FULL LENGTH SHOWN OR SPLICED WITH <br />MECHANICAL COUPLERS AS NOTED IN DETAILS. SPLICES IN WWF SHALL BE 1-1/2 MESHES WIDE. <br />12. THE MINIMUM CLEAR SPACING BETWEEN PARALLEL BARS IN A LAYER SHALL NOT BE LESS <br />THAN THE LARGER OF BAR DIAMETER, 1", OR 33% GREATER THAN THE MAXIMUM AGGREGATE <br />SIZE (NOMINAL), WHICHEVER IS GREATEST. THIS REQUIREMENT ALSO APPLIES TO THE CLEAR <br />SPACING BETWEEN DIFFERENT LAYERS OF PARALLEL BARS AND TO THE CLEAR DISTANCE <br />BETWEEN A CONTACT LAP SPLICE AND ADJACENT SPLICES OR BARS. <br />13. ALL HOOKS SHALL BE STANDARD HOOKS UNLESS OTHERWISE SHOWN OR NOTED. AT WALLS, <br />PROVIDE HOOKS AT ENDS OF ALL REINFORCING AT ENDS, CORNERS AND INTERSECTIONS, <br />UNO. <br />14. CONSTRUCTION JOINTS SHALL BE MADE ROUGH AND ALL LAITANCE REMOVED FROM THE <br />SURFACE. CONCRETE MAY BE ROUGHENED BY CHIPPING THE ENTIRE SURFACE, SAND <br />BLASTING, OR RAKING THE SURFACE TO PROVIDE 1/4" DEEP DEFORMATIONS. <br />15. REMOVE ALL DEBRIS FROM FORMS BEFORE CASTING ANY CONCRETE. <br />16. REINFORCING, DOWELS, BOLTS, ANCHORS, SLEEVES, ETC. TO BE EMBEDDED IN CONCRETE <br />SHALL BE SECURELY POSITIONED BEFORE PLACING CONCRETE. <br />17. ANCHOR BOLTS (AB'S) CAST IN CONCRETE FOR WALL SILL AND LEDGER APPLICATIONS SHALL <br />BE HEADED BOLTS WITH CUT THREADS CONFORMING TO ASTM F1554, UNO. REFER TO "WOOD" <br />NOTES FOR ADDITIONAL REQUIREMENTS FOR BOLTS IN CONTACT WITH PRESSURE TREATED <br />OR FIRE RETARDANT MATERIAL. REFER TO 'STRUCTURAL STEEL' NOTE FOR REQUIREMENTS <br />FOR ANCHOR RODS (AR'S) CAST IN CONCRETE FOR COLUMN BASE PLATE AND STEEL EMBED <br />APPLICATIONS. <br />18. WALLS SHALL BE CAST IN HORIZONTAL LAYERS OF 2'-0" MAXIMUM DEPTH. <br />19. CONCRETE IN WALLS, PIERS OR COLUMNS SHALL SET AT LEAST 2 HOURS BEFORE PLACING <br />CONCRETE IN BEAMS, SPANDRELS, OR SLABS SUPPORTED THEREON. <br />20. HORIZONTAL WALL BARS IN MULTI-CURTAIN CAST IN PLACE WALLS SHALL BE STAGGERED. <br />21. DOWEL ALL VERTICAL REINFORCING IN WALLS AND COLUMNS FROM FOUNDATION WITH SAME <br />SIZE BAR. <br />22. CONSOLIDATE CONCRETE PLACED IN FORMS BY MECHANICAL VIBRATING EQUIPMENT <br />SUPPLEMENTED BY HAND-SPADING, RODDING OR TAMPING. USE EQUIPMENT AND <br />PROCEDURES FOR CONSOLIDATION OF CONCRETE IN ACCORDANCE WITH THE <br />RECOMMENDED PRACTICES OF ACI 309 TO SUIT THE TYPE OF CONCRETE AND PROJECT <br />CONDITIONS. CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL (AS IN <br />WALLS) SO AS TO CAUSE SEGREGATION OF AGGREGATES. IN SUCH CASES HOPPERS AND <br />CHUTES OR TRUNKS OF VARIABLE LENGTHS SHALL BE USED SO THAT THE FREE UNCONFINED <br />FALL OF CONCRETE SHALL NOT EXCEED 6 FEET. <br />23. NO WOOD SPREADERS ALLOWED. NO WOOD STAKES ALLOWED IN AREAS TO BE CONCRETED. <br />24. ADDITIONAL REINFORCING IN PRECAST OR TILT-UP PANELS REQUIRED FOR LIFTING STRESSES <br />SHALL BE SUPPLIED BY CONTRACTOR. <br />25. PROVIDE #4x4'-0" DIAGONAL REINFORCING AT EACH REINFORCING LAYER OF SLAB AT ALL RE- <br />ENTRANT CORNERS TYPICAL UNO. THIS APPLIES TO SLAB ON GRADE, CONCRETE OVER METAL <br />DECK, AND ELEVATED STRUCTURAL SLAB CONDITIONS. <br />26. ALL SAW CUTTING SHALL BE DONE AFTER INITIAL SET HAS OCCURRED TO AVOID TEARING OR <br />DAMAGE BY THE SAW BLADE, BUT BEFORE INITIAL SHRINKAGE HAS OCCURRED. <br />27. NOTIFY STRUCTURAL ENGINEER A MINIMUM OF 48 HOURS BEFORE PLACING ANY CONCRETE. <br />28. CONCRETE STRENGTHS & MIX PROPERTIES: <br /> F'C @ MAX AGGR MAX W/CM* <br />ITEM 28 DAYS SIZE WEIGHT RATIO <br />A. SLAB ON GRADE 3500 PSI 1" NW 0.45 <br />* W/CM = WATER : CEMENTITIOUS MATERIAL RATIO <br />DESIGN CRITERIA <br />100SN002 <br />1. CODES AND STANDARDS <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />ASCE 7-16 <br />ACI 318-19 <br />AISC 360-16, 341-16, 358-16 <br />AISI S100-16 w/ S2-20, S240-20, S400-20 <br />TMS 402/602-16 <br />2018 NDS, 2021 SDPWS <br />SEISMIC: <br />SITE CLASS D (DEFAULT) <br />SS = 1.304 ; SDS = 1.043 <br />RISK CATEGORY: II <br />IP = 1.0 <br />4.LATERAL LOADS <br />(A) - <br />AB - <br />ABV - <br />ADDL - <br />AHU - <br />ALT - <br />APPROX - <br />ARCH - <br />(B) - <br />BLDG - <br />BLKG - <br />BLW - <br />BM - <br />B.O. - <br />BOF - <br />BOTT - <br />BRCG - <br />BRG - <br />BTWN - <br />BYND - <br />CC - <br />CG - <br />CJ - <br />CJP - <br />CL - <br />CLG - <br />CLR - <br />CMU - <br />COL - <br />CONC - <br />CONN - <br />CONT - <br />CONTR - <br />COORD - <br />CSK - <br />DBL - <br />DF - <br />DIAG - <br />DL - <br />DWG - <br />(E) - <br />EA - <br />EF - <br />EJ - <br />ELEV - <br />EN - <br />EOS - <br />EQ - <br />EW - <br />FB - <br />FC - <br />FDN - <br />FF - <br />FRMG - <br />FRT - <br />FS - <br />FTG - <br />GA - <br />GALV - <br />GLB - <br />GR - <br />GYP - <br />HD - <br />HDR - <br />HGR - <br />HK - <br />HORIZ - <br />HSB - <br />HSS - <br />HT - <br />OCCURS ABOVE <br />ANCHOR BOLT <br />ABOVE <br />ADDITIONAL <br />AIR HANDLING UNIT <br />ALTERNATE <br />APPROXIMATE <br />ARCHITECTURAL <br />OCCURS BELOW <br />BUILDING <br />BLOCKING <br />BELOW <br />BEAM <br />BOTTOM OF <br />BOTTOM OF FOOTING <br />BOTTOM <br />BRACING <br />BEARING <br />BETWEEN <br />BEYOND <br />CENTER TO CENTER <br />CENTER OF GRAVITY <br />CONSTRUCTION JOINT <br />COMPLETE JOINT PENETRATION <br />CENTERLINE <br />CEILING <br />CLEAR <br />CONCRETE MASONRY UNIT <br />COLUMN <br />CONCRETE <br />CONNECTION <br />CONTINUOUS <br />CONTRACTOR <br />COORDINATE <br />COUNTERSINK <br />DOUBLE <br />DOUGLAS FIR <br />DIAGONAL <br />DEAD LOAD <br />DRAWING <br />EXISTING <br />EACH <br />EACH FACE OR EDGE FASTENER <br />EXPANSION JOINT <br />ELEVATION <br />EDGE NAILING <br />EDGE OF SLAB <br />EQUAL <br />EACH WAY <br />FACE OF BLOCK/BRICK OR FLAT BAR <br />FACE OF CONCRETE <br />FOUNDATION <br />FINISH FLOOR <br />FRAMING <br />FIRE RETARDANT TREATED <br />FACE OF STUD OR FAR SIDE <br />FOOTING <br />GAUGE OR GAGE <br />GALVANIZED <br />GLUED LAMINATED BEAM <br />GRADE <br />GYPSUM <br />HOLDOWN <br />HEADER <br />HANGER <br />HOOK <br />HORIZONTAL <br />HIGH STRENGTH BOLT <br />HOLLOW STRUCTURAL SECTION <br />HEIGHT <br />JH - <br />LL - <br />LLH - <br />LLV - <br />LONGIT - <br />LS - <br />LW - <br />MECH - <br />MFR - <br />MI - <br />× - <br />MTL - <br />(N) - <br />NIC - <br />NS - <br />NTS - <br />NW - <br />o/ - <br />OH - <br />OPNG - <br />OSB - <br />PC - <br />PERP - <br />PJP - <br />PL - <br />PT - <br />PW - <br />REINF - <br />REQD - <br />RWD - <br />SC - <br />SCH - <br />SEOR - <br />SHTG - <br />SIM - <br />SJ - <br />SMS - <br />SOG - <br />SP - <br />SPCG - <br />SQ - <br />STD - <br />STFNR - <br />STGRD - <br />STL - <br />STRUCT - <br />SW - <br />T&B - <br />T&G - <br />THRD - <br />TN - <br />T.O. - <br />TOC - <br />TOF - <br />TOS - <br />TOW - <br />TRANS - <br />TYP - <br />UNO - <br />VERT - <br />VIF - <br />WF - <br />WHS - <br />WP - <br />WS - <br />WWF - <br />XS - <br />XXS - <br />Ø - <br />JOIST HANGER <br />LIVE LOAD <br />LONG LEG HORIZONTAL <br />LONG LEG VERTICAL <br />LONGITUDINAL <br />LAG SCREW <br />LIGHTWEIGHT <br />MECHANICAL <br />MANUFACTURER <br />MALLEABLE IRON <br />MARK <br />METAL <br />NEW <br />NOT IN CONTRACT <br />NEAR SIDE <br />NOT TO SCALE <br />NORMAL WEIGHT <br />OVER <br />OPPOSITE HAND <br />OPENING <br />ORIENTED STRAND BOARD <br />PIECE <br />PERPENDICULAR <br />PARTIAL JOINT PENETRATION <br />PLATE <br />PRESSURE TREATED <br />PUDDLE WELD <br />REINFORCING OR REINFORCEMENT <br />REQUIRED <br />REDWOOD <br />SLIP CRITICAL <br />SCHEDULE <br />STRUCTURAL ENGINEER OF RECORD <br />SHEATHING <br />SIMILAR <br />SLAB CONTROL JOINT <br />SHEET METAL SCREW <br />SLAB-ON-GRADE <br />STRUCTURAL PANEL <br />SPACING <br />SQUARE <br />STANDARD <br />STIFFENER <br />STAGGERED <br />STEEL <br />STRUCTURAL <br />SHEAR WALL <br />TOP & BOTTOM <br />TONGUE & GROOVE <br />THREADED <br />TOE NAIL <br />TOP OF <br />TOP OF CONCRETE (SLAB UNO) <br />TOP OF FOOTING OR TOP OF FRAMING <br />TOP OF STEEL <br />TOP OF WALL <br />TRANSVERSE <br />TYPICAL <br />UNLESS NOTED OTHERWISE <br />VERTICAL <br />VERIFY IN FIELD <br />WIDE FLANGE <br />WELDED HEADED STUD <br />WORK POINT <br />WOOD SCREW <br />WELDED WIRE FABRIC <br />EXTRA STRONG <br />DOUBLE EXTRA STRONG <br />ROUND OR DIAMETER <br />ABBREVIATIONS <br />100SN003 <br />ACI 318 <br />CBC/IBC <br />f'c= 3500 PSI CONC <br />LAP SPLICE LENGTHS FOR GRADE 60 REINFORCING BARS IN TENSION (Lst) <br />300SN002 <br />(ALL LENGTHS SHOWN ARE IN INCHES) <br />DEFINITIONS: <br />LD = DEVELOPMENT LENGTH OF DEFORMED BARS IN TENSION <br />LST = TENSION LAP SPLICE LENGTH <br />TOP = HORIZONTAL REINFORCEMENT LOCATED SUCH THAT MORE THAN 12 INCHES OF FRESH <br />CONCRETE IS CAST IN THE MEMBER BELOW THE SPLICE. <br />NOTES: <br />1. SCHEDULE APPLIES TO NORMAL WEIGHT CONCRETE WITH UNCOATED, GRADE 60 <br />REINFORCING STEEL FOR #3 BARS AND LARGER. <br />2. ROUND UP TO THE NEAREST WHOLE NUMBER FOR ALL LENGTH CALCULATIONS. <br />3. Lst SHALL BE 12 INCHES MINIMUM. <br />4. WHERE EPOXY-COATED BARS ARE USED, MULTIPLY LAP LENGTHS BY 1.2, BUT WHERE EPOXY- <br />COATED BARS HAVE CLEAR COVER LESS THAN 3 BAR DIA. OR CLEAR SPACING LESS THAN 6 <br />BAR DIA., MULTIPLY LAP LENGTHS BY 1.31 FOR TOP REBAR AND 1.5 FOR OTHER REBAR. <br />5. WHEN LIGHTWEIGHT CONCRETE IS USED, MULTIPLY LAP LENGTHS BY 1.33. <br />6. WHERE CLEAR SPACING OF BARS BEING SPLICED IS LESS THAN 2 BAR DIA. OR WHERE CLEAR <br />COVER OF BARS BEING SPLICED IS LESS THAN 1 BAR DIA., MULTIPLY LAP LENGTHS BY 1.50, <br />UNO. <br />7. WHERE CLASS A LAP SPLICE IS NOTED IN DETAIL, DIVIDE LENGTHS ABOVE BY 1.30. <br />8. DEVELOPMENT LENGTH OF DEFORMED BARS, Ld, SHALL BE CALCULATED BY DIVIDING THE <br />LENGTH ABOVE BY 1.30. Ld SHALL BE 12 INCHES MINIMUM. <br />9. WHEN SPLICING DIFFERENT SIZE BARS, Lst SHALL BE THE GREATER OF Ld OF THE LARGER <br />BAR AND Lst OF THE SMALLER BAR. <br />10. INDIVIDUAL BAR SPLICES WITHIN A BUNDLE SHALL NOT OVERLAP. INCREASE LAP LENGTHS BY <br />20 PERCENT FOR A THREE-BAR BUNDLE AND 33 PERCENT FOR A FOUR-BAR BUNDLE <br />11. THE LENGTHS SHOWN IN THE SCHEDULE SHALL BE INCREASED BY ALL APPLICABLE <br />MULTIPLIERS LISTED IN THE NOTES ABOVE. <br />#11#10#9#8#5 #6 #7 <br />121 <br />93 <br />109 <br />84 <br />97 <br />75 <br />86 <br />66 <br />43 <br />33 <br />52 <br />40 <br />75 <br />58 <br />#4#3 <br />35 <br />27 <br />26 <br />20 <br />A <br />REINF <br />LOCATION <br />SPLICE <br />CLASS <br />TOP <br />OTHER <br />INCH POUND <br />BAR SIZE <br />DIAMETER (in)METRIC BAR SIZE DIAMETER (mm) <br />#3 <br />#4 <br />#5 <br />#6 <br />#7 <br />#8 <br />#9 <br />#10 <br />#11 <br />#14 <br />#18 <br />0.375 <br />0.500 <br />0.625 <br />0.750 <br />0.875 <br />1.000 <br />1.128 <br />1.270 <br />1.410 <br />1.693 <br />2.257 <br />#10 <br />#13 <br />#16 <br />#19 <br />#22 <br />#25 <br />#29 <br />#32 <br />#36 <br />#43 <br />#57 <br />9.5 <br />12.7 <br />15.9 <br />19.1 <br />22.2 <br />25.4 <br />28.7 <br />32.3 <br />35.8 <br />43.0 <br />57.3 <br />STANDARD REBAR SIZES <br />INCH AND METRIC EQUIVALENTS <br />300SN003 <br />600 Q STREET, SUITE 200 <br />SACRAMENTO, CA 95811 <br />916 443 0303 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />. <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />14 <br />0 <br />1 <br /> <br />N <br />. <br /> <br />T <br />U <br />S <br />T <br />I <br />N <br /> <br />A <br />V <br />E <br />. <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br /># <br />1 <br />7 <br />0 <br />SI <br />M <br />O <br />N <br />M <br />E <br />D <br /> <br />I <br />M <br />A <br />G <br />I <br />N <br />G <br />06/19/2024 <br />24-004 <br />GKA ARCHITECTS. ALL RIGHTS RESERVED <br />COPYRIGHT © 2024 <br />WWW.GKA-ARC.COM <br />(213) 200-0030 <br />LOS ANGELES, CA 90071 <br />633 W 5TH ST, STE 2607 <br />SHEET NUMBER: <br />SHEET TITLE: <br />ISSUE DATE: <br />PROJECT NUMBER: <br />EN <br />G <br />I <br />N <br />E <br />E <br />R <br />I <br />N <br />G <br /> <br />C <br />O <br />N <br />S <br />U <br />L <br />T <br />A <br />N <br />T <br />DESCRIPTIONDATEREV <br />6/ <br />2 <br />4 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />1 <br />0 <br />: <br />4 <br />8 <br />: <br />1 <br />7 <br /> <br />A <br />M <br />C: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />K <br />e <br />i <br />t <br />h <br />S <br />\ <br />O <br />n <br />e <br />D <br />r <br />i <br />v <br />e <br /> <br />- <br /> <br />B <br />u <br />e <br />h <br />l <br />e <br />r <br /> <br />E <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br />, <br /> <br />I <br />n <br />c <br />\D <br />o <br />c <br />u <br />m <br />e <br />n <br />t <br />s <br />\ <br />2 <br />0 <br />2 <br />4 <br />- <br />0 <br />1 <br />3 <br />7 <br />_ <br />S <br />i <br />m <br />o <br />n <br />M <br />e <br />n <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />_ <br />R <br />v <br />t <br />2 <br />3 <br />_ <br />C <br />e <br />n <br />t <br />r <br />al <br />_ <br />k <br />s <br />o <br />w <br />l <br />e <br />y <br />. <br />r <br />v <br />t <br />GENERAL NOTES <br />S1.01 <br />APPLICABLE TO ALL DRAWINGS UNLESS NOTED OR SHOWN OTHERWISE <br />GENERAL NOTES <br />STRUCTURAL SHEET INDEX <br />S1.01 GENERAL NOTES <br />S1.02 GENERAL NOTES / STRUCTURAL SPECIAL <br />INSPECTIONS & TESTING <br />S2.01 FLOOR FRAMING PLAN <br />S5.01 CONCRETE DETAILS <br />S5.11 COMMON DETAILS <br />S5.12 METAL STUD COMMON DETAILS <br />S5.13 METAL STUD COMMON DETAILS <br />SEOR STAMP IS APPLICABLE ONLY <br />TO THE STRUCTURAL CONTENT OF <br />THE FOLLOWING DETAILS ON THIS <br />PAGE: <br />1401 N Tustin Ave Unit# <br />170 - TI1/27/2025