Laserfiche WebLink
1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL CEILING <br />ACCESS PANELS IN GYPSUM BOARD CEILINGS AS REQUIRED FOR <br />MECHANICAL, ELECTRICAL AND PLUMBING ACCESS PER LOCAL CODES, <br />WHETHER INDICATED ON DRAWINGS OR NOT. COORDINATE LOCATIONS SIZE <br />AND TYPE WITH ARCHITECT PRIOR TO INSTALLATION. <br />PRIOR TO CLOSING UP AND SEALING, ALL PLENUM SYSTEMS (HVAC, <br />PLUMBING, ELECTRICAL, ETC.) SHALL BE INSPECTED AND WHERE REQUIRED, <br />TESTED BY CONTRACTOR'S ENGINEERS, TO INSURE THEIR PROPER <br />INSTALLATION AND FUNCTION. <br />CEILING IN CLOSETS SHALL BE OF THE SAME HEIGHTS AND CONSTRUCTION <br />AS THAT OF ADJOINING SPACE, EXCEPT AS OTHERWISE NOTED. <br />THE GENERAL CONTRACTOR SHALL PROVIDE CUT-OUTS AND OTHER SPECIAL <br />PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES, <br />REGISTERS, AND DIFFUSERS AND OTHER INSERTED ITEMS. <br />ALL DOWNLIGHTS, WALL WASHERS, SPRINKLER HEADS, ETC., SHALL ALIGN IN <br />STRAIGHT LINE, UNLESS OTHERWISE NOTED. <br />FASCIAS OR ANY BREAK IN THE CEILING HEIGHTS SHALL BE AS SHOWN ON <br />DRAWINGS AND SHALL BE FORMED OF GYPSUM WALLBOARD ON TYPICAL <br />PROJECT FRAMING TYPE. <br />CEILING HEIGHTS SHALL BE AS SHOWN ON DRAWINGS AND DETAILS. ANY <br />DEVIATION FROM HEIGHTS SHOWN BASED UPON EXISTING FIELD CONDITIONS <br />SHALL BE SUBMITTED TO ARCHITECT FOR REVIEW PRIOR TO START OF WORK <br />IN QUESTION, OR RELATED WORK. <br />ALL SPRINKLERS IN DRYWALL CEILING AREAS SHALL HAVE CONCEALED HEAD <br />ASSEMBLIES. COLOR OF TRIM SHALL MATCH ADJACENT CEILING. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />WALLCOVERING SUBCONTRACTOR TO REVIEW PERTINENT WALL PATCHING <br />NOTES IN "PATCHING AND CUTTING ” ON THIS SHEET, AND ENSURE SURFACES <br />ARE PROPERLY PREPPED PRIOR TO COMMENCING WORK. <br />WALLS SHALL INCLUDE SURFACES FROM FLOOR TO CEILING, INCLUDING <br />PILASTERS, FASCIAS AND ALL VERTICAL SURFACES NOT INCLUDED IN <br />CEILING, UNLESS OTHERWISE NOTED. <br />THE GENERAL CONTRACTOR SHALL SUBMIT THREE (3) SAMPLES 12 X 12 OF <br />EACH FINISH FOR REVIEW BY ARCHITECT. THIS INCLUDES, BUT IS NOT <br />LIMITED TO ALL PAINT, WALLCOVERING, ETC. <br />ALL WALLS AND CEILINGS SHALL BE PROPERLY PREPARED, PATCHED, <br />SANDED, ETC., TO PROVIDE A LEVEL 4 FINISH. PROVIDE LEVEL 5 FINISH ONLY <br />WHERE INDICATED ON PLAN. <br />THE CONTRACTOR SHALL REMOVE ALL ELECTRICAL SWITCH PLATES AND <br />OUTLET PLATES, SURFACE HARDWARE, ETC., PRIOR TO PAINTING, <br />PROTECTING AND REPLACING SAME WHEN PAINTING HAS BEEN COMPLETED. <br />HE SHALL REMOVE ALL PAINT FROM WHERE IT HAS SPILLED, SPLASHED OR <br />SPLATTERED ON SURFACES, INCLUDING BUT NOT LIMITED TO LIGHT <br />FIXTURES, DIFFUSERS, REGISTERS, ETC. <br />EXISTING LOOSE PAINT SHALL BE REMOVED AND THE SURFACE SANDED <br />SMOOTH TO RECEIVE NEW FINISH. <br />UNEVENNESS IN EXISTING PARTITIONS SHALL BE SANDED OR CHIPPED AWAY <br />AND SURFACES PATCHED TO INSURE A PERFECTLY EVEN SURFACE. <br />THE CONTRACTOR SHALL EXAMINE ALL AREAS OF CONSTRUCTION AFTER <br />COMPLETION OF WORK BY ALL TRADES (INCLUDING TELEPHONE <br />INSTALLATION, FLOORING, ETC.) AND COMPLETE ALL NECESSARY “TOUCH- <br />UP” PAINTING AND/OR PATCHING PRIOR TO SCHEDULING A PUNCH-WALK. <br />IT IS THE INTENT OF THE DRAWINGS THAT ALL EXPOSED SURFACES RECEIVE <br />FINISHES UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. ANY <br />SURFACES WHICH DO NOT HAVE A SPECIFIC FINISH NOTED, OR ARE NOTED <br />TO REMAIN UNFINISHED, SHALL BE BROUGHT TO THE ATTENTION OF THE <br />ARCHITECT AND FINISHED PER ARCHITECT'S INSTRUCTIONS. <br />09 WALL FINISHES <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />GENERAL CONTRACTOR SHALL SUBMIT ALL REQUESTED FABRICATION <br />SHOP DRAWINGS, SAMPLES AND FIXTURE CUTS TO ARCHITECT FOR <br />REVIEW. DIGITAL PDF FILES SHALL BE SUBMITTED FOR DRAWINGS AND <br />FIXTURE CUTS. ALL SHOP DRAWINGS AND CUT SHEETS SIGNED <br />“REVIEWED ” SHALL SUPERSEDE ORIGINAL DRAWINGS IN DESIGN <br />APPEARANCE ONLY. SUBCONTRACTORS SHALL ASSUME RESPONSIBILITY <br />FOR ERRORS IN THEIR DRAWINGS. <br />GENERAL CONTRACTOR SHALL REVIEW SUBCONTRACTOR(S) SUBMITTED <br />DRAWINGS AND DATA, VERIFY FIELD MEASUREMENTS, APPLY REVIEW <br />STAMP AND SUBMIT TO ARCHITECT PROMPTLY. <br />GENERAL CONTRACTOR SHALL INDICATE ON REVIEW STAMP THAT THE <br />CONTRACTOR HAS REVIEWED SUBCONTRACTOR(S) SUBMITTAL FOR <br />CONFORMANCE TO THE SPECIFIED PRODUCT. <br />GENERAL CONTRACTOR SHALL DISAPPROVE AND RETURN TO <br />SUBCONTRACTOR ANY SUBMITTALS NOT MEETING THE REQUIREMENTS OF <br />THE CONTRACT DOCUMENTS. GENERAL CONTRACTOR SHALL MAINTAIN AN <br />UP-TO-DATE SUBMITTAL LOG, AND DISTRIBUTE THE LOG WEEKLY. <br />THE ARCHITECT WILL REVIEW AND EITHER ACCEPT OR REJECT, WITH <br />REASONABLE PROMPTNESS AND AS OUTLINED IN THE ACCEPTED <br />SUBMITTAL SCHEDULE, DATA AND DRAWINGS SUBMITTED BY THE <br />CONTRACTOR. THE ARCHITECT WILL REVIEW SUBMITTALS FOR <br />CONFORMANCE WITH THE INTENT OF THE DESIGN, AND FOR COMPLIANCE <br />WITH SPECIFIC AND RELEVANT REQUIREMENTS OF THE CONTRACT <br />DOCUMENTS. <br />THE ARCHITECT WILL REJECT AND RETURN TO THE CONTRACTOR, SHOP <br />DRAWINGS AND PROJECT LITERATURE SUBMITTED WITHOUT THE <br />CONTRACTOR(S) REVIEW STAMP AND/OR NOT THOROUGHLY REVIEWED BY <br />THE CONTRACTOR PRIOR TO SUBMITTAL. <br />THE ARCHITECT IS NOT RESPONSIBLE FOR DELAYS CAUSED BY REJECTION <br />OF SHOP DRAWINGS SUBMITTED BY THE CONTRACTOR. <br />REVIEW WILL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR <br />ERRORS. <br />REVIEW OF SUBMITTALS BY THE ARCHITECT SHALL NOT BE CONSTRUED AS <br />AUTHORIZING CHANGES IN THE CONTRACT SUM OR CONTRACT TIME, NOR <br />SHALL IT BE CONSTRUED AS RELIEVING THE CONTRACTOR OF HIS <br />RESPONSIBILITY FOR COORDINATION OF WORK WITH OTHER TRADES, OR <br />INTERPRETED AS APPROVING QUANTITIES AND DIMENSIONS. <br />THE ARCHITECTS REVIEW OF SUBMITTALS OR DATA SHALL NOT RELIEVE <br />THE CONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM <br />CONTRACT DRAWINGS OR SPECIFICATIONS UNLESS THE CONTRACTOR <br />HAS CALLED THE ARCHITECTS AND OWNER ’S ATTENTION TO SUCH <br />DEVIATIONS AND SECURED WRITTEN ACCEPTANCE, NOR SHALL IT RELIEVE <br />HIM OF RESPONSIBILITY FOR ERRORS IN SHOP DRAWINGS OR OTHER DATA. <br />SUBMITTAL PROCEDURES <br />1. <br />2. <br />3. <br />THE HVAC CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD SUPERVISION <br />OF ALL THEIR WORK DURING INSTALLATION AND SHALL INSPECT ALL <br />SYSTEMS FOR PROPER OPERATIONS AT COMPLETION OF JOB. <br />INSTALLATION SHALL BE COORDINATED WITH ALL TRADES AS REQUIRED FOR <br />PROPER ASSEMBLY. CEILING DIFFUSERS TO BE RELOCATED TO <br />ACCOMMODATE NEW LIGHT FIXTURE PATTERNS. <br />INTERIOR SPACES SHALL BE MECHANICALLY VENTILATED IN ACCORDANCE <br />WITH APPLICABLE CODES. <br />23 MECHANICAL <br /> SUBMITTAL & SHOP DRAWING LIST (MIN.) <br />1. <br />2. <br />ROOF SCREEN <br />PAINT <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS AS <br />REQUIRED TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS <br />INDICATED IN DRAWINGS OR AS OTHERWISE DIRECTED BY ARCHITECT. <br />THE GENERAL CONTRACTOR SHALL FURNISH OWNER WITH A COMPLETE <br />INVENTORY LIST OF ALL ITEMS THAT CAN BE REUSED AND/OR STORED IN <br />BUILDING STOCK, OBTAIN DIRECTIVE REGARDING THEIR DISPOSITION. <br />THE GENERAL CONTRACTOR SHALL EXECUTE ALL WORK WITHIN THE <br />REGULATION OF PROPERTY MANAGEMENT, CLIENT AND/OR OWNER FOR <br />DEMOLITION AND REMOVAL OF DEBRIS, INCLUDING AFTER HOURS WORK, AS <br />MAY BE REQUIRED. <br />ALL WORK DEMOLISHED SHALL BE REMOVED FROM THE PREMISES, EXCEPT <br />ITEMS TO BE REUSED OR RETURNED TO OWNER OR AS OTHERWISE NOTED. <br />THE GENERAL CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE <br />MATERIALS, BOTH FROM HIS OWN AND OTHER SUBCONTRACTORS <br />EMPLOYEES, AND PROVIDE FOR ITS REMOVAL FROM THE SITE. <br />THE GENERAL CONTRACTOR SHALL REMOVE FROM PREMISES ALL <br />CONDUITS, BOXES, PLATES, BRIDGED OR ANY OTHER TELEPHONE AND/OR <br />ELECTRICAL WIRING AND EQUIPMENT LEFT AFTER WALL DEMOLITION. <br />THE GENERAL CONTRACTOR SHALL PROVIDE A VISQUEEN SEAL FROM FLOOR <br />TO CEILING AT ALL INTERFACES TO PROTECT ADJACENT BUILDING PROPERTY <br />WHILE DEMOLITION AND CONSTRUCTION ARE IN PROGRESS. THIS SEAL IS TO <br />BE KEPT CLOSED AT ALL TIMES. <br />THE GENERAL CONTRACTOR SHALL CAP AND FLUSH OFF BEHIND FINISHED <br />SURFACES ALL PROJECTING PLUMBING, FLOOR ELECTRICAL/TELEPHONE <br />OUTLETS, AND ALL OTHER PROJECTING ITEMS WHICH ARE BEING <br />ABANDONED. <br />UPON COMPLETION OF THE DEMOLITION WORK, THE GENERAL CONTRACTOR <br />SHALL ENSURE THAT ALL AREAS ARE LEFT BROOM CLEAN. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />THE GENERAL CONTRACTOR SHALL DO ALL CUTTING, FITTING AND PATCHING <br />WORK THAT MAY BE REQUIRED TO MAKE ALL PARTS COME TOGETHER <br />PROPERLY, AND FIT TO RECEIVE OR BE RECEIVED BY WORK OF OTHER <br />CONTRACTORS WHERE SHOWN, OR REASONABLY IMPLIED BY THE DRAWINGS <br />AND NOTES. <br />THE GENERAL CONTRACTOR SHALL PROVIDE ALL FLOOR CUT-OUTS AND <br />PATCHING REQUIRED FOR THE INSTALLATION OF ALL WORK. <br />THE GENERAL CONTRACTOR SHALL SURVEY ALL EXISTING FINISHED <br />SURFACES TO REMAIN FOR CHIPS, CRACKS, HOLES, AND OTHER DAMAGE. <br />THESE DEFECTIVE SURFACES SHALL BE REPAIRED OR IF BEYOND REPAIRING, <br />THEN THE GENERAL CONTRACTOR SHALL REMOVE ALL EXISTING AND <br />REPLACE WITH NEW TO MATCH EXISTING TO THE SATISFACTION OF OWNER <br />AND TENANT. <br />THE GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING SURFACES TO <br />REMAIN, AFTER DEMOLITION OF EXISTING FINISHES, (I.E. WALL COVERING, <br />WALL BASE, ETC.) IF SURFACE IS NOT SMOOTH AND FLUSH TO RECEIVE NEW <br />FINISH, SUBCONTRACTOR SHALL SKIM COAT AND SAND SMOOTH. <br />IN ALL AREAS WHERE DEMOLITION CAUSES AN UNEVENNESS IN SLAB OR <br />LIGHTWEIGHT CONCRETE, THE CONTRACTOR SHALL PATCH TO LEVEL AS <br />REQUIRED TO RECEIVE NEW FLOORING FINISH. <br />ALL EXISTING OR NEW CONSTRUCTION WORK SHOWN ON DRAWINGS THAT IS <br />DAMAGED AS A RESULT OF WORK FOR THIS PROJECT SHALL BE PATCHED AS <br />REQUIRED TO MATCH IMMEDIATE EXISTING ADJACENT AREAS IN MATERIALS, <br />FIRE RATING, FINISH AND COLOR, UNLESS OTHERWISE NOTED. <br />CONTRACTOR TO DOWEL/FILL/PATCH SLAB AFTER SAWCUTTING TO ENSURE <br />SLAB STRUCTURAL INTEGRITY. <br />THE GENERAL CONTRACTOR SHALL PATCH ALL CRACKS, HOLES OR OTHER <br />IMPERFECTIONS (PROJECTIONS SHALL BE REMOVED AND PATCHED) TO <br />PROVIDE A CONTINUOUS SMOOTH FLOOR SURFACE. <br />THE GENERAL CONTRACTOR SHALL NOTIFY ARCHITECT AFTER FLOOR <br />PATCHING IS DONE AND RECEIVE THEIR REVIEW PRIOR TO INSTALLATION OF <br />FINISHED FLOORING. <br />PATCHING AND CUTTING <br />09 PAINT <br />A. <br />A. <br />1. <br />2. <br />A. <br />B. <br />1. <br />2. <br />A. <br />B. <br />A. <br />B. <br />C. <br />1. <br />2. <br />A. <br />A. <br />1. <br />2. <br />3. <br />A. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />A. <br />B. <br />1. <br />2. <br />3. <br />A. <br />B. <br />C. <br />D. <br />1. <br />2. <br />3. <br />4. <br />A. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />B. <br />C. <br />D. <br />E. <br />1. <br />2. <br />3. <br />F. <br />1. <br />2. <br />G. <br />H. <br />PART 1 - GENERAL <br />1.1 RELATED DOCUMENTS <br />DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING <br />GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 SPECIFICATION <br />SECTIONS, APPLY TO THIS SECTION. <br />1.2 SUMMARY <br />THIS SECTION INCLUDES THE FOLLOWING: <br />SURFACE PREPARATION. <br />FIELD APPLICATION OF PAINTS, STAINS, VARNISHES, AND OTHER <br />COATINGS. <br />1.3 SUBMITTALS <br />PRODUCT DATA - SUBMIT PRODUCT DATA SHEETS FOR EACH PRODUCT. <br />SAMPLES: <br />SUBMIT TWO PAINTED SAMPLES, ILLUSTRATING SELECTED COLORS AND <br />TEXTURES FOR EACH COLOR AND SYSTEMS SELECTED WITH SPECIFIED <br />COATS CASCADED. <br />SUBMIT ON SUITABLE BACKING, 8X10 INCH SIZE. <br />1.4 DELIVERY, STORAGE, AND PROTECTION <br />DELIVER PRODUCTS TO SITE IN SEALED AND LABELED CONTAINERS; INSPECT <br />TO VERIFY ACCEPTABILITY. <br />CONTAINER LABEL: INCLUDE MANUFACTURER'S NAME, TYPE OF PAINT, <br />BRAND NAME, LOT NUMBER, BRAND CODE, COVERAGE, SURFACE <br />PREPARATION, DRYING TIME, CLEANUP REQUIREMENTS, COLOR <br />DESIGNATION, AND INSTRUCTIONS FOR MIXING AND REDUCING. <br />1.5 ENVIRONMENTAL REQUIREMENTS <br />DO NOT APPLY MATERIALS WHEN SURFACE AND AMBIENT TEMPERATURES <br />ARE OUTSIDE THE TEMPERATURE RANGES REQUIRED BY THE PAINT <br />PRODUCT MANUFACTURER. <br />PROVIDE LIGHTING LEVEL OF 80 FT CANDLES MEASURED MID-HEIGHT AT <br />SUBSTRATE SURFACE. <br />ENVIRONMENT REQUIREMENTS: <br />COMPLY WITH MANUFACTURER'S RECOMMENDATIONS AS TO <br />ENVIRONMENTAL CONDITIONS UNDER WHICH COATINGS AND COATING <br />SYSTEMS CAN BE STORED AND APPLIED. <br />DO NOT PAINT WHEN THERE IS A THREAT OF RAIN WITHIN 24 HOURS OR <br />WHEN SURFACE OR AIR TEMPERATURES ARE AT OR BELOW 40 DEGREES. <br />1.6 WARRANTY <br />INSTALLER WARRANTY: 1 YEAR. <br />1.7 EXTRA STOCK <br />PROVIDE FOLLOWING: <br />MINIMUM 1 GALLON EACH PRODUCT IN ORIGINAL OR NEW 1 GALLON <br />CANS. <br />COLOR SPOT EACH LID. <br />IDENTIFY WITH FORMULA, LOCATION, PRODUCT AND DATE. <br />PART 2 - PRODUCTS <br />2.1 MANUFACTURERS <br />PAINTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE EITHER <br />THE NAMED PRODUCT OR AN EQUAL PRODUCT BY ONE OF THE OTHER <br />MANUFACTURERS SPECIFIED. <br />SHERWIN WILLIAMS. (BASIS OF DESIGN) <br />DUNN-EDWARDS. <br />GLIDDEN (ICI) PAINTS. <br />FRAZEE PAINT. <br />VISTA PAINT. <br />OR EQUAL. <br />2.2 PAINTS AND COATINGS <br />READY MIXED, EXCEPT FIELD-CATALYZED COATINGS. <br />PREPARE PIGMENTS: <br />TO A SOFT PASTE CONSISTENCY, CAPABLE OF BEING READILY AND <br />UNIFORMLY DISPERSED TO A HOMOGENOUS COATING. <br />FOR GOOD FLOW AND BRUSHING PROPERTIES. <br />CAPABLE OF DRYING OR CURING FREE OF STREAKS OR SAGS. <br />PART 3 - EXECUTION <br />3.1 EXAMINATION <br />VERIFY THAT SURFACES ARE READY TO RECEIVE WORK AS INSTRUCTED BY <br />THE PRODUCT MANUFACTURER. <br />EXAMINE SURFACES SCHEDULED TO BE FINISHED PRIOR TO <br />COMMENCEMENT OF WORK. REPORT ANY CONDITION THAT MAY <br />POTENTIALLY AFFECT PROPER APPLICATION. DO NOT PROCEED UNLESS <br />SUBSTRATE IS SUITABLE. <br />TEST SHOP-APPLIED PRIMER FOR COMPATIBILITY WITH SUBSEQUENT COVER <br />MATERIALS. <br />MEASURE MOISTURE CONTENT OF SURFACES USING AN ELECTRONIC <br />MOISTURE METER. DO NOT APPLY FINISHES UNLESS MOISTURE CONTENT OF <br />SURFACES ARE BELOW THE FOLLOWING MAXIMUMS: <br />PLASTER AND GYPSUM WALLBOARD: 12 PERCENT <br />MASONRY, CONCRETE, AND CONCRETE UNIT MASONRY: 12 PERCENT <br />INTERIOR WOOD: 15 PERCENT, MEASURED IN ACCORDANCE WITH <br />ASTMD4442. <br />EXTERIOR WOOD: 15 PERCENT, MEASURED IN ACCORDANCE WITH <br />ASTMD4442. <br />3.2 PREPARATION OF SURFACE <br />GENERAL: <br />CLEAN ALL EXTERIOR WALLS AND SURFACES OF LOOSE AND SCALY <br />PAINT, DIRT, DUST, CHALK, AND OTHER FOREIGN MATTER BY WATER- <br />BLASTING USING CARE NOT TO DAMAGE SUBSTRATE FOLLOWED BY <br />HAND SCRAPING, SANDING OR WIRE BRUSHING AFTER SURFACES ARE <br />DRY. MILDEW MUST BE TREATED WITH HOUSEHOLD BLEACH SOLUTION <br />AND RINSED THOROUGHLY. <br />PATCH, CAULK, SET PROTRUDING NAILS AND REPAIR ALL SURFACES AND <br />CRACKS WHERE NECESSARY WITH SUITABLE PATCHING MATERIALS AND <br />SMOOTH OFF TO MATCH ADJACENT SURFACES. <br />SAND GLOSSY SURFACES TO DULL SURFACE AND REMOVE RESIDUE. <br />REMOVE MILDEW FROM AFFECTED SURFACES WITH A SOLUTION OF TRI- <br />SODIUM PHOSPHATE AND BLEACH. RINSE WITH CLEAN WATER AND <br />ALLOW TO DRY COMPLETELY. <br />EXISTING SURFACES TO BE RECOATED SHALL BE THOROUGHLY CLEANED <br />AND DE-GLOSSED BY SANDING OR OTHER MEANS PRIOR TO PRIMING AND <br />PAINTING. PATCHED AND BARE AREAS SHALL BE SPOT PRIMED WITH THE <br />SAME PRIMER AS SPECIFIED FOR NEW WORK. <br />RUSTY METAL: SCRAPE, SAND OR WIRE WHEEL, FEATHERING EDGES TO <br />SOUND COATING. DUST SURFACES. <br />TOPCOAT. <br />REMOVE SOIL AND BODY OILS COMPLETELY FROM SURFACES, INCLUDING <br />HANDRAILS, DOOR EDGES AND POSTS. TREAT WITH LIQUID SANDPAPER <br />OR DULL-N-BOND. <br />REMOVE HARDWARE, ACCESSORIES, PLATES, FIXTURES AND SIMILAR <br />ITEMS NOT TO BE FINISHED. <br />REINSTALL AT COMPLETION. <br />PAINT EDGES OF SINK CUT-OUTS. <br />GALVANIZED SURFACES: REMOVE ALL OILS AND CONTAMINATION FROM <br />GALVANIZED SURFACES SCHEDULED TO BE PAINTED BY WASHING WITH A <br />COMPLIANT SOLVENT WASH. <br />FERROUS METAL: REMOVE GREASE, RUST, SCALE, DIRT AND DUST FROM <br />FERROUS METAL SURFACES. PRIMER COAT SHALL BE APPLIED NOT LESS <br />THAN 30 MINUTES, NOR MORE THAN 3 HOURS AFTER PREPARATION OF <br />SURFACE. <br />PRIMED METAL: SAND AND SCRAPE SHOP PRIMED METAL TO REMOVE LOOSE <br />PRIMER AND RUST. TOUCH-UP BARE, ABRADED AND DAMAGED AREAS WITH <br />METAL PRIMER. FEATHER EDGES TO MAKE TOUCH-UP PATCHES <br />INCONSPICUOUS. <br />WOOD SURFACES: <br />REMOVE DUST, GRIT AND FOREIGN MATTER FROM WOOD SURFACES. <br />SAND SURFACES AND DUST CLEAN. SPOT PRIME KNOTS, PITCH STREAKS <br />AND SAPPY SECTIONS WITH A STAIN BLOCKING PRIMER WHERE <br />SURFACES ARE TO BE PAINTED. FILL NAIL HOLES, CRACKS AND OTHER <br />DEFECTS AFTER PRIMING AND SPOT PRIME REPAIRS AFTER PATCHING <br />MATERIAL HAS FULLY CURED. <br />WOOD SURFACES WITH PEELING AREAS ARE TO HAVE EDGES OF <br />BROKEN PAINT FILM SANDED TO A FEATHER EDGE. <br />BACK PRIME WOOD TRIM. PAINT TOPS, BOTTOMS, EDGES AND CUT-OUTS <br />OF DOORS. <br />PLASTER SURFACES: <br />PLASTER SURFACES SHALL BE DRY AND FREE FROM EFFLORESCENCE, <br />ENCRUSTATIONS AND FOREIGN MATTER. FILL CRACKS, HOLES AND <br />IMPERFECTIONS, SMOOTHING REPAIRS TO MATCH ADJACENT TEXTURE. <br />ALLOW REPAIRS TO FULLY CURE BEFORE PRIMING. <br />PRIME PLASTER SURFACES WITH SPECIFIED PRIMER. CAULK ALL CRACKS. <br />GYPSUM BOARD: GYPSUM BOARD SHALL BE DUSTED CLEAN AND FREE FROM <br />ENCRUSTATIONS AND OTHER FOREIGN MATTER. <br />PREPARATION OF OTHER SURFACES SHALL BE PERFORMED FOLLOWING <br />SPECIFIC RECOMMENDATIONS OF THE COATING MANUFACTURER. <br />A. <br />B. <br />C. <br />D. <br />E. <br />F. <br />G. <br />H. <br />I. <br />J. <br />A. <br />A. <br />1. <br />2. <br />B. <br />1. <br />2. <br />3. <br />A. <br />B. <br />1. <br />2. <br />C. <br />1. <br />2. <br />3. <br />4. <br />A. <br />1. <br />2. <br />B. <br />1. <br />2. <br />C. <br />1. <br />2. <br />D. <br />1. <br />2. <br />E. <br />1. <br />2. <br />A. <br />1. <br />2. <br />B. <br />1. <br />2. <br />C. <br />1. <br />2. <br />D. <br />1. <br />2. <br />E. <br />1. <br />2. <br />F. <br />1. <br />2. <br />G. <br />1. <br />2. <br />H. <br />1. <br />2. <br />A. <br />3.3 APPLICATION <br />APPLY PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />WHERE ADJACENT SEALANT IS TO BE PAINTED, DO NOT APPLY FINISH <br />COATS UNTIL SEALANT IS APPLIED. <br />DO NOT APPLY FINISHES TO SURFACES THAT ARE NOT DRY. ALLOW APPLIED <br />COATS TO DRY BEFORE NEXT COAT IS APPLIED. <br />APPLY EACH COAT TO UNIFORM APPEARANCE. APPLY EACH COAT OF PAINT <br />SLIGHTLY DARKER THAN PRECEDING COAT UNLESS OTHERWISE APPROVED <br />SAND WOOD SURFACES LIGHTLY BETWEEN COATS TO ACHIEVE REQUIRED <br />FINISH. <br />VACUUM CLEAN SURFACES OF LOOSE PARTICLES. USE TACK CLOTH TO <br />REMOVE DUST PARTICLES JUST PRIOR TO APPLYING NEXT COAT. <br />STIPPLE ALL EDGES AND CORNERS TO CONCEAL BRUSH MARKS. <br />PAINT ENTIRE TRIM ELEMENT WITH LIKE COLOR. PAINTING OF FACES ONLY <br />IS UNACCEPTABLE. TRIM SURFACES MUST BE WRAPPED WITH THE TRIM <br />COLOR AND NOT "FACED OFF" OR "HOLLYWOODED". <br />DOORS: PAINT ENTIRE DOOR UNLESS OTHERWISE NOTED, INCLUDING DOOR <br />TOP AND BOTTOM EDGE SURFACES. <br />TINTING: TINT EACH PRIMER A LIGHTER SHADE TO FACILITATE <br />IDENTIFICATION OF EACH COAT WHERE MULTIPLE COATS OF THE SAME <br />MATERIAL ARE APPLIED. TINT PRIMER TO MATCH THE COLOR OF THE FINISH <br />COAT, BUT PROVIDE SUFFICIENT DIFFERENCES IN SHADE OF PRIMER TO <br />DISTINGUISH EACH SEPARATE COAT. <br />3.4 PROTECTION <br />PROTECT WORK OF OTHER TRADES AND ITEMS NOT INTENDED TO RECEIVE <br />PAINT. INSTALL "WET PAINT" SIGNS TO PROTECT NEWLY PAINTED <br />SURFACES. <br />3.5 CLEANING <br />PROTECTION - CAREFULLY PROTECT AREAS WHERE WORK IS IN PROGRESS <br />FROM DAMAGE. <br />PROVIDE AND SPREAD CLEAN DROP CLOTHS WHEN AND WHERE <br />REQUIRED TO PROVIDE THE NECESSARY PROTECTION. <br />IMMEDIATELY CLEAN-UP ALL ACCIDENTAL SPATTER, SPILLAGE, <br />MISPLACED PAINT AND RESTORE THE AFFECTED SURFACE TO ITS <br />ORIGINAL CONDITION. <br />CLEAN-UP: <br />CLEAN UP DEBRIS DAILY PER OSHA REQUIREMENTS. <br />AT COMPLETION OF WORK, REMOVE ALL MATERIALS, SUPPLIES, DEBRIS <br />AND RUBBISH AND LEAVE EACH AREA IN A CLEAN, ACCEPTABLE <br />CONDITION. <br />COLLECT WASTE MATERIAL WHICH MAY CONSTITUTE A FIRE HAZARD, <br />PLACE IN CLOSED METAL CONTAINERS, AND REMOVE DAILY FROM SITE. <br />3.6 SURFACES TO BE FINISHED <br />PAINT ALL NEW WORK AND AREAS AFFECTED BY NEW WORK, UNLESS <br />NOTED OTHERWISE. <br />DO NOT PAINT OR FINISH THE FOLLOWING ITEMS: <br />ITEMS FULLY FACTORY-FINISHED UNLESS SPECIFICALLY NOTED. <br />FIRE RATING LABELS, EQUIPMENT SERIAL NUMBER AND CAPACITY <br />LABELS. <br />MECHANICAL AND ELECTRICAL: USE PAINT SYSTEMS DEFINED FOR THE <br />SUBSTRATES TO BE FINISHED. <br />PAINT ALL INSULATED AND EXPOSED PIPES OCCURRING IN FINISHED <br />AREAS TO MATCH BACKGROUND SURFACES, UNLESS OTHERWISE <br />INDICATED. <br />PAINT SHOP PRIMED ITEMS OCCURRING IN FINISHED AREAS. <br />PAINT INTERIOR SURFACES OF AIR DUCTS AND CONVECTOR AND <br />BASEBOARD HEATING CABINETS THAT ARE VISIBLE THROUGH GRILLES <br />AND LOUVERS WITH ONE COAT OF FLAT BLACK PAINT. <br />PAINT DAMPERS EXPOSED BEHIND LOUVERS, GRILLES AND CONVECTOR <br />AND BASEBOARD CABINETS TO MATCH FACE PANELS. <br />3.7 PAINT SYSTEMS - EXTERIOR <br />PLASTER/STUCCO, OPAQUE, EGGSHELL, LATEX, 3 COAT: <br />ONE COAT: LOXON MASONRY PRIMER A24W300. <br />TWO COATS (UPGRADE): S-W SUPER PAINT EXTERIOR LATEX (1.4 MILS <br />DFT PR/CT). <br />FERROUS METALS, UNPRIMED, LATEX, 3 COAT: <br />ONE COAT: PRO-CRYL PRIMER UNIVERSAL PRIMER <br />TWO COATS: PRO INDUSTRIAL WATER BASED ALKYD <br />GALVANIZED METALS, SEMI-GLOSS, ALKYD, 3 COAT: <br />ONE COAT: PRO-CRYL UNIVERSAL PRIMER B66-310. <br />TWO COATS: PRO INDUSTRIAL WATER BASED ALKYD. <br />WOOD AND COMPOSITE WOOD, FLAT, OPAQUE, LATEX, 3 COAT: <br />ONW COAT: A-100 EXTERIOR LATEX PRIMER B42W41 <br />TWO COATS: A-100 FLAT A6W851. <br />WOOD AND COMPOSITE WOOD, SEMI-GLOSS, OPAQUE, LATEX, 3 COAT <br />ONE COAT: A-100 EXTERIOR LATEX PRIMER B42W41. <br />TWO COATS: SOLO 100% ACRYLIC A76 SERIES. <br />3.8 PAINT SYSTEMS -INTERIOR (NO VOC) <br />GYPSUM BOARD, LATEX EGG-SHELL: <br />ONE COAT: HARMONY INTERIOR LATEX PRIMER B11W900. <br />TWO COATS: HARMONY INTERIOR LATEX EG-SHELL, B9 SERIES. <br />GYPSUM BOARD, ACRYLIC SEMI-GLOSS ENAMEL: <br />ONE COAT: HARMONY INTERIOR LATEX PRIMER B11W900. <br />TWO COATS: HARMONY INTERIOR LATEX SEMI-GLOSS B10 SERIES. <br />MASONRY, LATEX EGG-SHELL: <br />ONE COAT: HARMONY INTERIOR LATEX PRIMER B11W900. <br />TWO COATS: HARMONY INTERIOR LATEX EGG-SHELL, B9 SERIES. <br />PLASTER, LATEX EGG-SHELL: <br />ONE COAT: HARMONY INTERIOR LATEX PRIMER B11W900. <br />TWO COATS: HARMONY INTERIOR LATEX EG-SHELL, B9 SERIES. <br />PLASTER, ACRYLIC SEMI-GLOSS ENAMEL: <br />ONE COAT: HARMONY INTERIOR LATEX PRIMER B11W900. <br />TWO COATS: HARMONY INTERIOR LATEX SEMI-GLOSS B10 SERIES. <br />WOOD, COMPOSITION BOARD, LATEX EGG-SHELL: <br />ONE COAT: HARMONY INTERIOR LATEX PRIMER B11W900. <br />TWO COATS: HARMONY INTERIOR LATEX EG-SHELL, B9 SERIES. <br />WOOD, ACRYLIC SEMI-GLOSS ENAMEL <br />ONE COAT: HARMONY INTERIOR LATEX PRIMER B11W900. <br />TWO COATS: SOLO 100% ACRYLIC SEMI-GLOSS A76 SERIES. <br />METAL - STEEL, ALUMINUM, GALVANIZED, ACRYLIC SEMI-GLOSS ENAMEL: <br />ONE COAT: ONE COAT: PRO-CRYL UNIVERSAL PRIMER B66-310. <br />TWO COATS: PRO INDUSTRIAL WATER BASED ALKYD. <br />3.9 COLORS <br />TO BE SELECTED BY ARCHITECT FROM DISTRICT ’S STANDARD COLOR <br />PALETTE. <br />09 PAINT (CONT.)DEMOLITION <br />CEILINGS <br />No. C31793W <br />REN. 02-28-25 <br />L <br />AINROFILACFOETATS <br />ICENSED A RCHITECT <br />N <br />I <br />LL M I TZE <br />I A <br />Job. No. <br />Date <br />Drawn/Checked by <br />Scale <br />FOR PLAN <br />REVIEW ONLY <br />This and all other project documents and all ideas, aesthetics and <br />designs incorporated therein are instruments of service. <br />All project documents are the registered property of ITZEN. (ITZEN) <br />and cannot be lawfully used in whole or in part for any project or <br />purpose except as described in the contractual agreement between <br />ITZEN and Client. ITZEN hereby gives formal notice that any such <br />project document use, reproduction or modification (misuse) is not only <br />unlawful but automatically binds all parties involved with misuse to fully <br />indemnify and defend ITZEN and ITZEN's Consultants to the maximum <br />legal extent against all losses, demands, claims or liabilities arising <br />directly or indirectly from project document misuse. <br />Project documents describe design intent of work and are not a <br />representation of as-built or existing conditions. ITZEN and ITZEN's <br />Consultants make no representations concerning the accuracy of <br />documents and are not responsible for any discrepancies between <br />project documents and the existing conditions. <br />Copyright 2021C <br />mailing: <br />1800 N. Bristol Street #C-418 <br />Santa Ana CA 92706 <br />714-716-5042 <br />sayhello@ITZEN.com <br />www.ITZEN.com <br /> 12" = 1'-0" <br />23014 <br />04-08-2024 <br />WBI/AT <br />AS <br />S <br />I <br />S <br />T <br />A <br />N <br />C <br />E <br /> <br />L <br />E <br />A <br />G <br />U <br />E <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />10 <br />3 <br />1 <br /> <br />W <br /> <br />F <br />I <br />R <br />S <br />T <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />ME <br />C <br />H <br />A <br />N <br />I <br />C <br />A <br />L <br /> <br />E <br />Q <br />U <br />I <br />P <br />M <br />E <br />N <br />T <br /> <br />S <br />C <br />R <br />E <br />E <br />N <br />SHEET <br />SPECIFICATIONS <br />A0.1 <br />REV DESCRIPTION DATE <br />1031 W 1st St - <br />101119950 & 4013927010/18/2024