My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1011 W Second St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Second St
>
1011 W Second St
>
1011 W Second St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 2:15:26 PM
Creation date
6/5/2025 7:35:36 AM
Metadata
Fields
Template:
Plan
Permit Number
101120893
Full Address
1011 W Second St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
127
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Project <br />1011 <br />Job Ref. <br />Section <br />LINE-1 <br />Sheet no./rev. <br /> 5 <br />Calc. by <br />N.K <br />Date <br />19/12/2023 <br />Chk'd by Date App'd by Date <br />fc / Fc' = 0.010 <br />PASS - Design compressive stress exceeds maximum applied compressive stress <br />Wind load deflection <br />Design shear force;Vw = fWserv W = 1.02 kips <br />Deflection limit;w_allow= h / 500 = 0.2 in <br />Induced unit shear;vw_max = Vw / (Co bi) = 75.8 lb/ft <br />Anchor tension force;T = max(0 kips,vw_max h - 0.6 (D + Swt h) b / 2) = 0.000 kips <br />Chord compression force;C = max(0 kips,vw_max h + 0.6 (D + Swt h) b / 2) = 2.538 kips <br />Vertical elongation at anchor;T = T / ka = 0.000 in <br />Vertical compression at chord;C = 0.04 in C / (Ae Fc_perp) = 0.013 in <br />Total vertical deflection ;a = (T + C) (b / beff) = 0.014 in <br />Shear wall deflection – Eqn. 4.3-1;sww = 2 vw_max h3 / (3 E Ae bi) + vw_max h / (Ga) + h a / bi = <br />0.049 in <br />sww / w_allow = 0.245 <br />PASS - Shear wall deflection is less than deflection limit <br />Seismic deflection <br />Design shear force;Vs = Eq = 1.928 kips <br />Deflection limit;s_allow= 0.025 h = 2.5 in <br />Induced unit shear;vs_max = Vs / (Co bi) = 143.27 lb/ft <br />Anchor tension force;T = max(0 kips,vs_max h - (0.6 - 0.2 SDS) (D + Swt h) b / 2) = <br />0.000 kips <br />Chord compression force;C = max(0 kips,vs_max h + (0.6 - 0.2 SDS) (D + Swt h) b / 2) = <br />2.442 kips <br />Vertical elongation at anchor;T = T / ka = 0.000 in <br />Vertical compression at chord;C = 0.04 in C / (Ae Fc_perp) = 0.013 in <br />Total vertical deflection ;a = (T + C) (b / beff) = 0.013 in <br />Shear wall elastic deflection – Eqn. 4.3-1;swse = 2 vs_max h3 / (3 E Ae bi) + vs_max h / (Ga) + h a / bi = <br />0.085 in <br />Deflection ampification factor;Cd = 4 <br />Seismic importance factor;Ie = 1 <br />Amp. seis. deflection – ASCE7 Eqn. 12.8-15;sws = Cd swse / Ie = 0.34 in <br />sws / s_allow = 0.136 <br />PASS - Shear wall deflection is less than deflection limit <br />Page 41 of 108 <br />1011 W Second St <br />5/1/2025
The URL can be used to link to this page
Your browser does not support the video tag.