Laserfiche WebLink
LIGHTING FIXTURE SCHEDULE (FOR REFERENCE ONLY) <br />2X2 RECESSED LED WITH CURVED ACRYLIC LED PANEL. <br />SAME AS CR-22 BUT INCLUDES EMERGENCY BATTERY BACKUP WITH A MINIMUM <br />OUTPUT OF 1100 LUMENS FOR A MINIMUM OF 90 MINUTES. <br />EDGE LIT LED EXIT SIGN, RED LETTERS, FACE AS INDICATED ON PLANS <br />BATTERY BACKUP FOR A MINIMUM OF 90 MINUTES. <br />TRACK MOUNTED LED ACCENT LIGHT. VIOLITE LED PAR30 LAMP, WHITE FINISH. 40 DEGREE <br />BEAM FIXTURE TO BE JUNO LIGHTING, LAMP TO BE SOLAIS LIGHTING. <br />MONOPOINT MOUNTED DUAL HEAD LED ACCENT LIGHT. <br />VIOLITE LED PAR30 LAMP, WHITE FINISH. 40 DEGREEE BEAM. <br />FIXTURE TO BE JUNO LIGHTING, LAMP TO BE SOLAIS LIGHTING. <br />SINGLE CIRCUIT LIGHTING TRACK, WHITE FINISH. TO BE SUSPENDED ON UNISTRUT AT A <br />HEIGHT AS INDICATED ON PLANS. TRACK CAN BE FIELD CUT. <br />IF NOTED, PROVIDE JUNO TRAC-MASTER CURRENT LIMITING DEVICE WITH AMPERAGE <br />INDICATED. <br />DECORATIVE PENDANT LIGHT NOMINAL 16" DIAMETER. EXTERIOR SHADE: MATTE BLACK <br />FINISH + FLAT WHITE UNDERSHADE. BLACK FIELD CUTTABLE CORD. POWER CORD COMES <br />IN 20'. AOR TO VERIFY DROP HEIGHT DOES NOT EXCEED CORD LENGTH. <br />MARK LIGHTING <br />#WHSPR 2X2 3300LM 30K 80CRI MIN1 ZT MVOLT SWC <br />ENCORE LIGHTING <br />MARK LIGHTING <br />#WHSPR 2X2 3300LM 30K 80CRI MIN1 ZT <br />MVOLT SWC E10WLCP <br />JUNO #T831WH <br />SOLAIS LIGHTING #LR30LN/40/30V/1450-WHITE <br />JUNO #T832WH <br />SOLAIS LIGHTING #LR30LN/40/30V/1450-WHITE <br />JUNO #T832WH <br />SOLAIS LIGHTING #LR30LN/40/30V/1450-WHITE <br />BARN LIGHT USA <br />BLE-C-WHA16-106-INSIDE FLAT WHITE-CGB-20FT <br />-LED16-2700K <br />DESCRIPTION LAMP MANUFACTURER <br />LED 29.8W <br />LED 4.2W <br />TYPE CONTROL <br />0-10V <br />0-10V <br />NO CONTROLS <br />CR22 <br />CR-22-EM <br />ES-1 <br />LED 29.8W <br />VOLTS <br />120V <br />120V <br />120V <br />SEE ARCHITECTURAL PLANS AND SPECIFICATIONS FOR ADDITIONAL DETAILS <br />LED 18W FORWARD PHASEF4A120V <br />LED 36W FORWARD PHASEF4A-DH 120V <br />--FORWARD PHASEF4B120V <br />LED 18WF8 120V <br />LINEAR SUSPENDED MOUNTED LED. 800 LM/FT, SILVER HOUSING. AIRCRAFT CABLE <br />SUSPENSION. INTEGRAL 0-10V DIMMING POWER SUPPLY. <br />LED 30W BARTCO LIGHTING <br />BLT205-6-30-D-R-A-C8-ESS <br />0-10VF5120V <br />LINEAR SUSPENDED MOUNTED LED. 800 LM/FT, SILVER HOUSING. AIRCRAFT CABLE <br />SUSPENSION. INTEGRAL 0-10V DIMMING POWER SUPPLY. SAME AS F5 BUT INCLUDES <br />REMOTE MOUNTED EMERGENCY BATTERY BACKUP WITH A MINIMUM OF 1400 LUMENS. <br />LED 30W BARTCO LIGHTING <br />BLT205-6-30-D-R-A-C8-ESS <br />0-10VF5-EM 120V <br />SAME AS CR-22 BUT INCLUDES DRYWALL GRID ADAPTER FOR INSTALLATION IN 0-10VCR-22a LED 29.8W MARK LIGHTING120V <br />HARD CEILING APPLICATION.#WHSPR 2X2 3300LM 30K 80CRI MIN1 ZT MVOLT SWC <br />PROVIDE DRYWALL GRID ADAPTER DGA22 (ORDERED SEPARATELY) <br />#X-RC-1-C-U (TAILOR AS REQUIRED TO MATCH LIGHTING PLANS) <br />DIMMING <br />DIMMING <br />DIMMING <br />DIMMING <br />DIMMING <br />DIMMING <br />DIMMING <br />DIMMING <br />DECORATIVE PENDANT LIGHT NOMINAL 12" DIAMETER. EXTERIOR SHADE: MATTE BLACK <br />FINISH + FLAT WHITE UNDERSHADE. BLACK FIELD CUTTABLE CORD. POWER CORD COMES <br />IN 20'. AOR TO VERIFY DROP HEIGHT DOES NOT EXCEED CORD LENGTH. <br />LED 18W BARN LIGHT USA <br />BLE-C-WHA12-106-INSIDE FLAT WHITE-CGB-20FT <br />-LED16-2700K <br />F9 120V <br />0-10V <br />DIMMING <br />0-10V <br />DIMMING <br />OUTDOOR EGRESS EMERGENCY FIXTURE WITH BATTERY BACKUP. FIXTURE <br />SHALL BE NORMALLY 'OFF' AND SHALL TURN 'ON' WHEN NORMAL POWER IS LOST. <br />EMERGENCY FIXTURE SHALL BE CONNECTED TO BRANCH CIRCUIT UNSWITCHED, AHEAD. <br />LED 10W SIGNTEX INC <br />MAE-BB10BW-SD <br />(REPLACEMENT SPECIFICATION) <br />KK 120V UNSWITCHED <br />OF LOCAL SWITCHING OR CONTACTOR CONTROL. <br />A. VERIFY CEILING CONDITIONS AND COORDINATE LIGHT FIXTURE MOUNTING HARDWARE AND TRIMS <br />NEEDED TO SUIT CEILING CONDITIONS PRIOR TO ORDERING. <br />B. VERIFY QUANTITIES, MODEL NUMBERS AND DESCRIPTIONS WITH MANUFACTURER PRIOR TO <br />PLACING ORDER. <br />C. VERIFY FINISH AND COLOR WITH ARCHITECT PRIOR TO PLACING ORDER. <br />D. REFER TO ARCHITECTURAL DRAWINGS AND DETAILS FOR EXACT LOCATIONS, MOUNTING HEIGHTS <br />AND ADDITIONAL MOUNTING INFORMATION. CONTACT ARCHITECT IMMEDIATELY IF THERE ARE <br />DISCREPANCIES BETWEEN THE ARCHITECTURAL AND ELECTRICAL LIGHTING PLANS. <br />E. CATALOG NUMBERS SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE <br />ORDERED BY MANUFACTURER AND CATALOG NUMBERS ONLY. FIRST READ THE COMPLETE <br />DESCRIPTION, NOTES AND SPECIFICATIONS IN CONJUNCTION WITH THE CATALOG NUMBER TO <br />DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE MANUFACTURES <br />LISTED ARE THE BASIS FOR THE DESIGN <br />F. REFER TO DIVISION 16 SPECIFICATIONS FOR ACCEPTABLE LAMP AND BALLAST MANUFACTURERS <br />AND ADDITIONAL INFORMATION. <br />G. REFER TO LIGHTING CONTACTOR SCHEDULE AND PANELBOARD SCHEDULES FOR CONTROL <br />INFORMATION. <br />LIGHTING SCHEDULE NOTES <br />NOTES: <br />1. PROVIDE SUBMITTAL FOR ARCHITECT, LIGHTING DESIGNER, AND ENGINEER APPROVAL PRIOR TO <br />RELEASE OF ORDER. SUBMITTAL TO INCLUDE DETAILS OF ALL MOUNTING AND ELECTRICAL <br />COMPONENTS AS REQUIRED BY THE CONTRACTOR FOR A COMPLETE INSTALLATION. <br />2. DUE TO AESTHETIC OR PERFORMANCE CRITERIA, SPECIFIED MANUFACTURER SHALL BE THE ONLY <br />MANUFACTURER ALLOWED TO BID UNLESS OTHERWISE APPROVED BY ARCHITECT. <br />3. CONTRACTOR SHALL SUPPLY A COMPLETE AND OPERATIONAL SYSTEM TO COMPLY WITH DESIGN <br />INTENT. <br />4. CONFIRM FINAL FIXTURE LENGTHS WITH FIELD-CONFIRMED CONDITIONS PRIOR TO ORDERING. <br />5. PROVIDE TRACK, FEEDS, FITTINGS FOR CONTINUOUS ROW MOUNTING PER PLANS. TRACK TO BE <br />SUSPENDED ON UNISTRUT (UNISTRUT TO BE PROVIDED AND INSTALLED BY CONTRACTOR AND <br />PAINTED TO MATCH THE CEILING) AT HEIGHTS AS INDICATED ON THE PLANS. <br />CALLOUT SYMBOL MANUFACTURER CATALOG #DESCRIPTION <br />LOW VOLTAGE <br />CEILING SENSOR LMDC-100 <br />CEILING MOUNT LOW VOLTAGE DUAL <br />TECHNOLOGY SENSOR, EXTENDED <br />RANGE 360 COVERAGE. <br />LIGHTING CONTROL DEVICE SCHEDULE <br />WATTSTOPPEROS <br />LOW VOLTAGE <br />SWITCH <br />LOW VOLTAGE ON/OFF SWITCH WITH <br />INDICATOR LIGHTS INDICATING <br />ON/OFF. <br />POWER PACK <br />WATTSTOPPER LOW VOLTAGE 0-10V <br />DIMMING POWER/RELAY PACK, AUTO <br />ON, 120/277 VAC. <br />LMSW-101WATTSTOPPER <br />LMRC-211WATTSTOPPER <br />LOW VOLTAGE <br />DIMMER <br />LOW VOLTAGE DIMMER WITH PRESET <br />SWITCH AND INDICATOR LIGHTS <br />INDICATINGON/OFF. <br />LMDM-101WATTSTOPPER <br />COMBINATION <br />OCCUPANCY <br />SENSOR DIMMER <br />SWITCH <br />0-10V WALL DIMMER SWITCH WITH <br />DUAL TECHNOLOGY OCCUPANCY <br />SENSOR. <br />DW-311WATTSTOPPER <br />COMBINATION <br />OCCUPANCY <br />SENSOR SWITCH <br />DW-100WATTSTOPPER WALL SWITCH WITH DUAL <br />TECHNOLOGY OCCUPANCY SENSOR. <br />PP1 <br />LV <br />LV <br />OS <br />OS <br />POWER PACK <br />WATTSTOPPER LOW VOLTAGE <br />UNIVERSAL DIMMING POWER/RELAY <br />PACK, AUTO ON, 120/277 <br />VAC WITH WATTSTOPPER 0-10V TO <br />PHASE ADAPTIVE CONVERTER. <br />PROVIDE CONVERTER QUANTITIES AS <br />REQUIRED PER POWER LIMITATIONS, <br />750W MAX AT 120V; 1300W MAX AT <br />277V. <br />LMRC-211 WITH <br />BF-SDS-10V-AST <br />(QUANTITIES AS <br />REQUIRED) <br />WATTSTOPPERPP2 <br />A. OCCUPANCY SENSOR LAYOUT BASED ON WATTSTOPPER COVERAGE PATTERNS. <br />ADJUST QUANTITIES AND LOCATIONS FOR EQUIVALENT MANUFACTURERS LISTED <br />BELOW PER MANUFACTURER-SPECIFIC SPACING CRITERIA. <br />B. MANUFACTURERS CONSIDERED EQUIVALENT FOR SUBMISSION ARE LISTED IN <br />'EQUIVALENT MANUFACTURER' COLUMN IN SCHEDULE. DURING SUBMITTALS, <br />PROVIDE PRODUCT CUTSHEETS AND SHOP DRAWINGS (AS FURTHER DEFINED IN <br />GENERAL NOTES OF THIS SCHEDULE) FOR ENGINEER'S REVIEW. <br />C. SHOP DRAWINGS FOR LIGHTING CONTROL DEVICES THAT ARE INTENDED FOR USE <br />AS A LIGHTING CONTROL SYSTEM SHALL INCLUDE PROJECT SPECIFIC LIGHTING <br />CONTROL SCHEMATICS AND SCHEDULES. ALSO, AT ENGINEER'S REQUEST, <br />PROVIDE A SCALED EQUIPMENT PLAN FOR REVIEW OF EQUIPMENT LOCATIONS <br />WITHIN PROJECT SPACE CONSTRAINTS. <br />D. OCCUPANCY SENSOR SHOP DRAWINGS SHALL INCLUDE LIGHTING PLANS <br />SHOWING LOCATION, MOUNTING HEIGHT, ORIENTATION AND COVERAGE AREAS <br />FOR EACH OCCUPANCY. <br />E. PROVIDE ALL OCCUPANCY SENSORS BY THE SAME MANUFACTURER <br />F. VERIFY COLOR(S) FOR ALL WALL AND CEILING MOUNTED LIGHTING CONTROL <br />DEVICES WITH THE ARCHITECT. <br />G. PROVIDE COPIES OF OPERATION INSTRUCTIONS FOR ALL DEVICES TO OWNER. <br />H. ALL WALL SWITCH AND CEILING SENSORS SHALL HAVE AN ADJUSTABLE TIME <br />DELAY RANGE OF 0-20 MIN, UON. <br />I. DO NOT INSTALL LINE VOLTAGE SENSORS ON GFCI PROTECTED CIRCUITS. <br />J. LIGHTING CONTROLS PRICING SHALL BE COMPLETELY SEPARATE OF ANY LIGHT <br />FIXTURE PRICING. ANY LIGHTING CONTROLS PRICING THAT IS SUBMITTED WITH <br />LIGHT FIXTURE PRICING (UNIT OR MINI-LOT) WILL BE IMMEDIATELY REJECTED IN <br />ITS ENTIRETY. <br />K. INSTALL WALL BOX DIMMERS TO ACHIEVE FULL RATING SPECIFIED AND INDICATED <br />AFTER DE-RATING FOR GANGING AS INSTRUCTED BY MANUFACTURER. <br />L. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING COMPATIBILITY OF ALL <br />LIGHTING CONTROL DEVICES IN THIS SCHEDULE THAT ARE INTENDED TO <br />OPERATE TOGETHER. <br />M. PROVIDE A NEUTRAL CONDUCTOR TO ALL WALL BOX DIMMERS. DO NOT SHARE <br />NEUTRAL CONDUCTOR ON LOAD SIDE OF DIMMER. <br />LIGHTING CONTROL NOTES <br />SCHEDULED NOTES: <br />1. REQUIRES A NEUTRAL CONDUCTOR FOR OPERATION <br />Mechanical and Electrical Engineers <br />Lilker Associates <br />1001 Avenue of the Americas <br />New York, NY 10018 <br />tel 212.695.1000 <br />fax 212.695.1299 <br />www.lilker.com <br />Kenneth A. Gruskin AIA <br />No. Date Description <br />Consultant: <br />Checked By: <br />Drawn By: <br />Job Address: <br />Drawing Title: <br />Revision Issue: <br />Professional Seal: <br />Drawing Number: <br />2024 Gruskin Architecture + Design, P.C.c <br />This document and the ideas and designs incorporated <br />herein, as an instrument of professional service, is the <br />property of GRUSKIN ARCHITECTURE + DESIGN, P.C., <br />and is not to be used in whole or in part for any other <br />project without the written authorization of GRUSKIN <br />ARCHITECTURE + DESIGN, P.C. <br />North <br />Arrow: <br />Job Name and Number: <br />Date Issued For <br />All Rights Reserved <br />Client: <br />Landlord: <br />Permit: <br />Bid: <br />Construction: <br />0006261 <br />AR91629 <br />5421 <br />9613 <br />39209 <br />10635 <br />2537 <br />11016 <br />5734 <br />ARC 2596 <br />4674 <br />2666 <br />AI 09999 <br />2796 <br />0401 011223 <br />2572 <br />17680 <br />RA-015432-B <br />025528-1 NY <br />TX <br />VA <br />VT <br />MA <br />MT <br />RI <br />PA <br />NY <br />NJ <br />NH <br />MD <br />LA <br />ME <br />KS <br />FL <br />DE <br />CT <br />AZ <br />AL <br />C-1967WY <br />RA011075GA <br />AR10400066IN <br />C-29898CA <br />NM 004168 <br />ARC-400347CO <br />HI AR 11489 <br />PR 19965 <br />OR 4899 <br />SC 6834 <br />NC 9961 <br />13761OH <br />05713IA <br />WV 3727 <br />IL 001-019152 <br />UT 5881358-0301 <br />ID AR-984459 <br />1301052379MI <br />ARC100723DC <br />WI 9900-005MN44326 <br />A-3547NE <br />3811AR <br />5967KY 101374TN <br />MS 3860 <br />1666ND <br />A-2005029740MO <br />a4895OK <br />NV 5521 <br />WA 10344 <br />13167AK <br />SD 11532 <br />C: <br />\ <br />R <br />e <br />v <br />i <br />t <br /> <br />L <br />o <br />c <br />a <br />l <br /> <br />F <br />i <br />l <br />e <br />s <br />\ <br />2 <br />4 <br />0 <br />0 <br />1 <br />3 <br />0 <br />8 <br />_ <br />V <br />E <br />R <br />I <br />Z <br />O <br />N <br />_ <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />_ <br />C <br />A <br />_ <br />EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br />_ <br />v <br />2 <br />3 <br />_ <br />D <br />B <br />e <br />l <br />l <br />B <br />R <br />N <br />E <br />Z <br />. <br />r <br />v <br />t <br />2023-0069 <br />Proposed <br />Store Design <br />for: VERIZON <br />Metro Pointe <br />3500 South Bristol Street <br />Suite 100 <br />Santa Ana, CA 92704 <br />3/15/24 <br />3/15/24 <br />LIGHTING SCHEDULE <br />AND CONTROLS <br />E.1.4 <br />DB <br />MH <br />53 OF 81 <br />NOTE: <br />LIGHTING FIXTURES TO BE PROVIDED BY VERIZON. <br />3500 S Bristol St Unit# 100 - <br />101119098, 20182666 & <br />401390437/11/2024