My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3500 S Bristol St Unit# 100 - 101119098, 20182666 & 40139043 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bristol St
>
3500 S Bristol St Unit# 100
>
3500 S Bristol St Unit# 100 - 101119098, 20182666 & 40139043 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 6:26:27 AM
Creation date
6/5/2025 7:36:36 AM
Metadata
Fields
Template:
Plan
Permit Number
20182666
40139043
101119098
Full Address
3500 S Bristol St Unit# 100
Street Number
3500
Street Direction
S
Street Name
Bristol
Street Suffix
St
Unit Number
100
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FUNCTION 2 <br />SALES <br />A#2 <br />C2 <br />LED DRIVER 0-10V DIMMING <br />LED LUMINAIRES <br />120 VOLT <br />D LOW VOLTAGE <br />DIMMER <br />24 VOLT <br />LED DRIVER <br />0-10V PENDANTS & <br />FOWARD PHASE <br />DUAL HEADS <br />120 VOLT <br />D LOW VOLTAGE <br />DIMMER <br />24 VOLT <br />LED DRIVER FORWARD PHASE <br />TRACK LIGHTING <br />LIGHTING SEQUENCE: {LD-1} <br />LIGHTING SEQUENCE: {LD-1} <br />LIGHTING SEQUENCE: {LD-1}120 VOLT <br />CONTACTOR-C2 <br />NOTE: <br />LIGHTING CONTROL DIAGRAM IS GENERIC IN <br />NATURE AND MAY NOT SHOW ALL CONNECTIONS <br />REQUIRED. <br />H N <br />120 VOLT CIRCUIT <br />SECURITY SYSTEM <br />EMS <br />MOMENTARY <br />OVERRIDE <br />FUNCTION 1 <br />MERCHANDISE <br />C1 <br />SPARE <br />CONTACTOR-C1 <br />SPARE <br />SPARE <br />SPARE <br />H N <br />120 VOLT CIRCUIT <br />EMS <br />MOMENTARY <br />OVERRIDE <br />LED DRIVER 0-10V DIMMING <br />LED SIGNAGE120 VOLT <br />FUNCTION 4 <br />SIGNAGE <br />H N <br />120 VOLT CIRCUIT <br />PHOTOCELL <br />C5 <br />FUNCTION 5 <br />EXTERIOR <br />H N <br />120 VOLT CIRCUIT <br />PHOTOCELL <br />C6 <br />SPARE <br />LIGHTING SEQUENCE: {LD-6} <br />CONTACTOR-C5 <br />CONTACTOR-C6 <br />EMSMOMENTARY <br />OVERRIDE <br />EMSMOMENTARY <br />OVERRIDEFUNCTION 3 <br />SPARE <br />C4 <br />SPARE <br />CONTACTOR-C4 <br />SPARE <br />SPARE <br />SPARE <br />SPARE <br />SPARE <br />A#4 <br />A#6 <br />B#42 <br />B#33 <br />H N <br />120 VOLT CIRCUIT <br />FSG CONTACTOR ENCLOSURE, SEE EMS SHEET <br />120 VOLT EXHAUST <br />FAN <br />SPARE <br />D LOW VOLTAGE <br />DIMMER <br />24 VOLT <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />INDICATES SWITCHING CONTACTOR. <br />LIGHTING CONTROL DIAGRAM NOTES <br />INDICATES POTENTIAL LOW VOLTAGE TRANSFORMER <br />INDICATES CONTACTORC# <br />OC <br />LS <br />{LD-4} <br />INDICATES OCCUPANCY/VACANCY SENSOR. <br />INDICATES DIMMING DAYLIGHT SENSOR. <br />INDICATES SEQUENCE OF OPERATION. <br />INDICATES PHOTO CELL PC <br />LED DRIVER FORWARD PHASE <br />TRACK LIGHTING <br />LIGHTING SEQUENCE: {LD-1}120 VOLTA#22 <br />D LOW VOLTAGE <br />DIMMER <br />24 VOLT <br />LED DRIVER 0-10V DIMMING <br />LED SIGNAGE120 VOLT LIGHTING SEQUENCE: {LD-6}B#19 <br />LED DRIVER 0-10V DIMMING <br />LED SIGNAGE120 VOLT LIGHTING SEQUENCE: {LD-6}A#41 <br />CONTACTOR No.CIRCUIT No. OPERATED BY LOAD DESCRIPTION <br />C1 EMS & WALL SWITCH <br />(EMS CONTROLED)MERCHANDISE LIGHTS <br />C2 <br />C3 <br />EMS & WALL SWITCH <br />(KEYPAD CONTROLLED)SALES LIGHTS <br />CONTACTOR SCHEDULE <br />CONTACTOR NOTES: <br />1. ALL CONTACTORS SHALL BE NORMALLY CLOSED, ELECTRICALLY OPERATED AND ELECTRICALLY HELD. <br />2. PROVIDE ALL REQUIRED CONTROL ACCESSORIES NECESSARY FOR THE OPERATION AS DESCRIBED ABOVE. <br />3. PROVIDE LABELS FOR EACH CONTACTOR INDICATING THE LOAD CONTROLLED. <br />4. NUMBER ALL WIRES AT EACH CONTACTOR. <br />C4 <br />XX:XX <br />A#2, A#4, A#6, A#22, B#42 <br />B#42 <br />C5 EMS SIGN LIGHTINGB#19, B#33, A#41 <br />C6 EMS EXTERIOR / SITE LIGHTINGXX:XX <br />SPAREXX:XX <br />EMS & WALL SWITCH <br />(KEYPAD CONTROLLED)EXHAUST FAN <br />LIGHTING FUNCTIONS – SEQUENCE OF OPERATION <br />FUNCTION #1: (CONTACTOR 'C1'): MERCHANDISE LIGHTING <br />THE CONTACTOR SHALL BE ENABLED ANY TIME ONE OF THE FOLLOWING CONDITIONS ARE TRUE, OTHERWISE THE CONTACTOR SHALL BE DISABLED <br />IF ALL OF THE CONDITIONS ARE FALSE. <br />1. MERCHANDISE LIGHTING IS ENABLED ONE HOUR BEFORE STORE OPENING AND DISABLED ONE HOUR AFTER STORE CLOSE (TIMES MAY BE <br />ADJUSTED PER LOCATION). <br />FUNCTION #2: (CONTACTOR 'C2' & 'C3'): SALES LIGHTING <br />THE CONTACTOR SHALL BE ENABLED ANY TIME ONE OF THE FOLLOWING CONDITIONS ARE TRUE, OTHERWISE THE CONTACTOR SHALL BE DISABLED <br />IF ALL OF THE CONDITIONS ARE FALSE. <br />1. STORE IS DISARMED – SEE SECURITY PANEL. <br />FUNCTION #3: (CONTACTOR 'C4'): NOT USED <br />FUNCTION #4: (CONTACTOR C5'): SIGN LIGHTING <br />THE SIGN LIGHITNG CONTACTOR SHALL BE ENABLED 24/7 AND ENABLED BY PHOTOCELL (TIMES MAY BE ADJUSTED PER LOCATION). <br />FUNCTION #5: (CONTACTOR 'C6'): EXTERIOR / SITE LIGHTING, WHERE APPLICABLE <br />THE CONTACTOR SHALL BE ENABLED ANY TIME ONE OF THE FOLLOWING CONDITIONS ARE TRUE, OTHERWISE THE CONTACTOR SHALL BE DISABLED <br />IF ALL OF THE CONDITIONS ARE FALSE. <br />1. EXTERIOR /SITE LIGHTNG IS DISABLED AT MIDNIGHT AND ENABLED AT 6 AM AND ENABLED BY PHOTOCELL (TIMES MAY BE ADJUSTED PER <br />LOCATION). <br />OVERRIDES <br />LIGHTING CAN BE OVERRIDDEN USING THE MOMENTARY PUSH BUTTONS LOCATED ON THE BOTTOM OF THE EMS PANEL LABELED 'INDOOR LIGHTING <br />OVERRIDE' AND 'OUTDOOR LIGHTING OVERRIDE'. PUSHING THESE BUTTONS WILL OVERRIDE LIGHTS ON FOR 2 HRS. IF LIGHTS DO NOT COME ON <br />WHEN OVERRIDDEN, THE 'EMERGENCY LIGHTING OVERRIDE' SWITCH LOCATED ON THE EMS LIGHTING CONTROL PANEL CAN BE USED TO BYPASS THE <br />EMS AND FORCE ALL LIGHTS ON. <br />SECURITY SYSTEM (INSTALLED AND WIRED BY OTHERS) <br />WHEN THE SECURITY SYSTEM IS ARMED (UNOCCUPIED), THE RELAY CONTACTS SHALL OPEN. WHEN THE SECURITY SYSTEM IS DISARMED <br />(OCCUPIED), THE RELAY CONTACTS SHALL CLOSE. <br />ID LIGHTING CONTROL SPACE TYPE <br />LD-1 SEQUENCE: DIMMED AND SWITCHED LUMINAIRES ARE CONTROLLED IN THIS SPACE. <br />ON: THE LUMINAIRES TURN ON VIA EMS CENTRAL TIME CLOCK AND RELAY PANEL. LOCAL OVERRIDE SWITCHES, LOCATED IN SECURE AREAS, SHALL PROVIDE UP TO 120 MIN. OF ADDITIONAL <br />ILLUMINATION. THE OVERRIDE SWITCHES SHALL BE LOCATED IN A POSITION WHERE THE OCCUPANT CAN SEE THE LUMINAIRES THEY ARE CONTROLLING. <br />ADJUST: GENERAL LED LUMINAIRE OUTPUT SHALL BE MANUALLY ADJUSTED VIA RAISE LOWER LOCAL DIMMERS AS SHOWN ON DRAWINGS. <br />ADDITIONAL CONTROL: THE GENERAL LIGHTING WITHIN EACH DAYLIGHT ZONE (PRIMARY AS WELL AS SECONDARY), AS DEFINED BY STATE AND LOCAL CODES, SHALL AUTOMATICALLY CONTINUOUSLY <br />ADJUST TO MAINTAIN A PRESET FOOT-CANDLE LEVEL OF NO LESS THAN 50FC AT +30" BASED ON THE AVAILABLE DAYLIGHT IN EACH DAYLIGHT ZONE. <br />ADDITIONAL CONTROLS: DISPLAY LUMINAIRES SHALL BE CONTROLLED SEPARATELY FROM GENERAL LIGHTING VIA ON/OFF CONTROLS AS SHOWN ON DRAWINGS. <br />OFF: THE EMS CENTRAL TIME CLOCK OR THE ACTIVATION OF THE SECURITY SYSTEM SHALL TURN OFF THE NORMAL POWER, WHICHEVER COMES FIRST. LOCAL OVERRIDES ARE AVAILABLE AS <br />INDICATED ON DRAWINGS. <br />RETAIL SALES; <br />POS <br />LD-2 <br />LD-3 <br />LIGHTING SEQUENCE OF OPERATION <br />LD-4 <br />LD-5 EXTERIOR LIGHTING <br />BACK OF HOUSE <br />STORAGE; JANITOR; <br />TELCO; CORRIDOR <br />RESTROOM <br />SEQUENCE: DIMMED LUMINAIRES ARE CONTROLLED IN THIS SPACE. <br />ON: LUMINAIRES MANUALLY TURN ON VIA LOCAL DIMMERS. <br />ADJUST: LUMINAIRE OUTPUT SHALL BE MANUALLY ADJUSTED VIA RAISE LOWER CONTROL DIMMERS AS SHOWN ON DRAWINGS. <br />OFF: AFTER THE SPACE HAS BEEN VACANT FOR 15 MIN., VACANCY SENSOR SHALL AUTOMATICALLY TURN THE NORMAL LUMINAIRES OFF. NIGHTLIGHTS SHALL REMAIN ON AT ALL TIMES. <br />ON: WHEN ACTIVITY IS DETECTED, SWITCHED RECEPTACLES SHALL AUTOMATICALLY BE TURNED ON. <br />OFF: AFTER THE SPACE HAS BEEN VACANT FOR 15 MIN., SWITCHED RECEPTACLES SHALL AUTOMATICALLY TURN OFF. <br />ON: LUMINAIRES MANUALLY TURN ON VIA LOCAL DIMMERS. <br />ADJUST: LUMINAIRE OUTPUT SHALL BE MANUALLY ADJUSTED VIA RAISE LOWER DIMMER. <br />OFF: AFTER THE SPACE HAS BEEN VACANT FOR 15 MIN., ALL LUMINAIRES SHALL AUTOMATICALLY TURN OFF VIA VACANCY SENSOR. <br />SEQUENCE: DIMMED LUMINAIRES ARE CONTROLLED IN THIS SPACE. <br />ON: LUMINAIRES MANUALLY TURN ON TO 50% VIA OCCUPANCY SENSOR. <br />ADJUST: LIGHT OUTPUT SHALL MANUALLY BE ADJUSTED VIA LOCAL DIMMER. <br />OFF: OCCUPANCY SENSOR SHALL TURN THE LIGHTS OFF AFTER THE SPACE HAS BEEN VACANT FOR 15 MIN. <br />SEQUENCE: DIMMED LUMINAIRES ARE CONTROLLED IN THIS SPACE. <br />ON: THE LUMINAIRES TURN ON VIA PHOTOCELL PROTOCOL THROUGH EMS CONTROL PANEL. LOCAL OVERRIDE SWITCHES, LOCATED IN SECURE AREAS, SHALL PROVIDE UP TO 120 MIN. OF ADDITIONAL <br />ILLUMINATION. THE OVERRIDE SWITCHES SHALL BE LOCATED IN A POSITION WHERE THE OCCUPANT CAN SEE THE LUMINAIRES THEY ARE CONTROLLING. <br />ADJUST: LED LUMINAIRE OUTPUT SHALL BE MANUALLY ADJUSTED VIA RAISE LOWER LOCAL DIMMERS AS SHOWN ON DRAWINGS. <br />OFF: THE EMS CENTRAL TIME CLOCK SHALL TURN THE NORMAL POWER LUMINAIRES OFF AT MIDNIGHT. <br />MS + MS - 10V 10V 0V 0V <br />MAN. <br />SW. <br />DIM 1 <br />VIO GRY <br />DIM 2 <br />VIO GRY <br />CLASS 1 OR CLASS 2 <br />(SELV) <br />0 -10V DIMMER W/ <br />ON/OFF CONTROL <br />PU <br />R <br />P <br />L <br />E <br />GR <br />A <br />Y <br />PURPLE <br />GRAY <br />BLACK <br />WHITE <br />LOAD 2 <br />OUT L2 <br />LOAD 2 <br />IN L2 <br />CONTACTOR <br />NEUTRAL <br />WHITE <br />BLACK <br />LP-1-# <br />LIGHTING <br />LOADRED <br />LOAD 1 <br />OUT L1 <br />LINE L1 <br />CONSTANT HOT <br />NEUT. N <br />WH <br />I <br />T <br />E <br />WHITE <br />PCC2D-00W <br />POWER PACKWHITE <br />BLACKCONSTANT HOT <br />NEUTRAL RED <br />RED CONSTANT HOT <br />OCC2 <br />SWITCH <br />RE <br />D <br />BL <br />A <br />C <br />K <br />GR <br />E <br />Y <br />ELECTRONIC <br />DIMMING BALLAST <br />(O-10 VDC) <br />LAMP <br />LAMP <br />BLUE <br />BLUE <br />RED <br />RED <br />VIOLET (-) <br />GREY (-) <br />YELLOW <br />YELLOW <br />RED <br />BLACK <br />VI <br />O <br />L <br />E <br />T <br />GR <br />E <br />Y <br />LS-301 <br />AC BALLAST <br />EMERGENCY BATTERY <br />HOT <br />COM <br />CONTACTOR <br />EMERGENCY / NIGHT LIGHT (N.L.) FIXTUREEMERGENCY ONLY FIXTURE <br />AC BALLAST <br />EMERGENCY BATTERY <br />HOT <br />COM <br />Mechanical and Electrical Engineers <br />Lilker Associates <br />1001 Avenue of the Americas <br />New York, NY 10018 <br />tel 212.695.1000 <br />fax 212.695.1299 <br />www.lilker.com <br />Kenneth A. Gruskin AIA <br />No. Date Description <br />Consultant: <br />Checked By: <br />Drawn By: <br />Job Address: <br />Drawing Title: <br />Revision Issue: <br />Professional Seal: <br />Drawing Number: <br />2024 Gruskin Architecture + Design, P.C.c <br />This document and the ideas and designs incorporated <br />herein, as an instrument of professional service, is the <br />property of GRUSKIN ARCHITECTURE + DESIGN, P.C., <br />and is not to be used in whole or in part for any other <br />project without the written authorization of GRUSKIN <br />ARCHITECTURE + DESIGN, P.C. <br />North <br />Arrow: <br />Job Name and Number: <br />Date Issued For <br />All Rights Reserved <br />Client: <br />Landlord: <br />Permit: <br />Bid: <br />Construction: <br />0006261 <br />AR91629 <br />5421 <br />9613 <br />39209 <br />10635 <br />2537 <br />11016 <br />5734 <br />ARC 2596 <br />4674 <br />2666 <br />AI 09999 <br />2796 <br />0401 011223 <br />2572 <br />17680 <br />RA-015432-B <br />025528-1 NY <br />TX <br />VA <br />VT <br />MA <br />MT <br />RI <br />PA <br />NY <br />NJ <br />NH <br />MD <br />LA <br />ME <br />KS <br />FL <br />DE <br />CT <br />AZ <br />AL <br />C-1967WY <br />RA011075GA <br />AR10400066IN <br />C-29898CA <br />NM 004168 <br />ARC-400347CO <br />HI AR 11489 <br />PR 19965 <br />OR 4899 <br />SC 6834 <br />NC 9961 <br />13761OH <br />05713IA <br />WV 3727 <br />IL 001-019152 <br />UT 5881358-0301 <br />ID AR-984459 <br />1301052379MI <br />ARC100723DC <br />WI 9900-005MN44326 <br />A-3547NE <br />3811AR <br />5967KY 101374TN <br />MS 3860 <br />1666ND <br />A-2005029740MO <br />a4895OK <br />NV 5521 <br />WA 10344 <br />13167AK <br />SD 11532 <br />C: <br />\ <br />R <br />e <br />v <br />i <br />t <br /> <br />L <br />o <br />c <br />a <br />l <br /> <br />F <br />i <br />l <br />e <br />s <br />\ <br />2 <br />4 <br />0 <br />0 <br />1 <br />3 <br />0 <br />8 <br />_ <br />V <br />E <br />R <br />I <br />Z <br />O <br />N <br />_ <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />_ <br />C <br />A <br />_ <br />EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br />_ <br />v <br />2 <br />3 <br />_ <br />D <br />B <br />e <br />l <br />l <br />B <br />R <br />N <br />E <br />Z <br />. <br />r <br />v <br />t <br />2023-0069 <br />Proposed <br />Store Design <br />for: VERIZON <br />Metro Pointe <br />3500 South Bristol Street <br />Suite 100 <br />Santa Ana, CA 92704 <br />3/15/24 <br />3/15/24 <br />LIGHTNG CONTROL <br />DIAGRAMS <br />E.2.2 <br />DB <br />MH <br />56 OF 81 <br />N.T.S.1 CONTACTOR DIAGRAM <br />N.T.S.3 DAYLIGHT ZONE CONTROL DIAGRAM <br />N.T.S.4 DAYLIGHT ZONE WIRING DIAGRAM <br />N.T.S.2 EMERGENCY BALLAST DIAGRAM <br />NOT U <br />S <br />E <br />D <br />NOT U <br />S <br />E <br />D <br />3500 S Bristol St Unit# 100 - <br />101119098, 20182666 & <br />401390437/11/2024
The URL can be used to link to this page
Your browser does not support the video tag.