My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3500 S Bristol St Unit# 100 - 101119098, 20182666 & 40139043 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bristol St
>
3500 S Bristol St Unit# 100
>
3500 S Bristol St Unit# 100 - 101119098, 20182666 & 40139043 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 6:26:27 AM
Creation date
6/5/2025 7:36:36 AM
Metadata
Fields
Template:
Plan
Permit Number
20182666
40139043
101119098
Full Address
3500 S Bristol St Unit# 100
Street Number
3500
Street Direction
S
Street Name
Bristol
Street Suffix
St
Unit Number
100
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CEILING <br />FINISHED FLOOR <br />FIRE TREATED PLYWOOD. <br />REFERENCE ARCHITECTURAL <br />DRAWINGS. <br />MAIN EMS PANEL <br />LIGHTING CONTACTOR <br />PANEL <br />(1) CONDUIT FOR EMS PHASE <br />LOSS RELAY LEADS. (1) CONDUIT <br />FOR EMS PANEL POWER. <br />CONDUITS FOR CONTROL WIRING <br />FROM EMS TO LIGHTING <br />CONTACTORS. <br />LIGHTING BRANCH <br />CIRCUIT CONDUITS <br />FLOOR <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />PROVIDE (1) 24" LONG 2" SLEEVE WITH <br />BUSHINGS IN CEILING FOR ANTENNA <br />CABLE ACCESS. <br />EVDO REPEATER <br />CDMA REPEATER <br />REPEATER <br />6' <br /> <br />- <br /> <br />6 <br />" <br />4 1/2" <br />6' <br /> <br />- <br /> <br />2 <br />" <br />PROVIDE (2) DEDICATED 30A <br />TWIST LOCK OUTLETS (L6-30R) <br />LABELED "BDA" <br />FLOOR <br />OVERHEAD 12" CABLE RUNWAY <br />BY CCCABLE RUNWAY WALL SUPPORT <br />BRACKET BY CC <br />D-RINGS FOR CABLE <br />MANAGEMENT (AS REQUIRED) BY CC <br />4" CONDUIT SLEEVE THRU <br />CEILING FOR TELCO <br />COPPER GROUND <br />BUS BAR BY EC <br />2" CONDUIT SLEEVE THRU <br />CEILING FOR TELCO <br />DOUBLE DUPLEX RECEPTACLE <br />120V, 20A BY EC <br />OUTLINE OF TELCO RACK <br />TELCO ROOM ELEVATION FOR <br />REFERENCE ONLY, REFER TO <br />ELECTRICAL PLAN FOR EXACT ROOM <br />LAYOUT AND PLACEMENT OF THE <br />FIXTURES <br />SHALL BE CIRCUITED TO THE SAME <br />PHASE IN PANELBOARD. <br />(2) 4" CONDUITS FROM BUILDING DEMARC <br />LOCATION TO TELCO ROOM. COORDINATE <br />EXACT LOCATION OF DEMARC WITH <br />LANDLORD. PROVIDE LABELED PULL <br />STRING IN BOTH CONDUITS. <br />1' <br /> <br />- <br /> <br />6 <br />" <br />MOTOR <br />3 <br />MOTOR <br />2 <br />MOTOR <br />1 <br />MOTOR 1 - DIR2 - BLK <br />MOTOR 1 - DIR1 - RED <br />MOTOR 2 - DIR2 - BLK <br />MOTOR 2 - DIR1 - RED <br />MO <br />T <br />O <br />R <br /> <br />3 <br /> <br />- <br /> <br />D <br />I <br />R <br />2 <br /> <br />- <br /> <br />B <br />L <br />K <br />MO <br />T <br />O <br />R <br /> <br />3 <br /> <br />- <br /> <br />D <br />I <br />R <br />1 <br /> <br />- <br /> <br />R <br />E <br />D <br />MOTOR 3 - NEUTRAL - WHT <br />MOTOR 3 - GROUND - GRN <br />MOTOR 2 - NEUTRAL - WHT <br />MOTOR 2 - GROUND - GRN <br />MO <br />T <br />O <br />R <br /> <br />1 <br /> <br />- <br /> <br />N <br />E <br />U <br />T <br />R <br />A <br />L <br /> <br />- <br /> <br />W <br />H <br />T <br />MO <br />T <br />O <br />R <br /> <br />1 <br /> <br />- <br /> <br />G <br />R <br />O <br />U <br />N <br />D <br /> <br />- <br /> <br />G <br />R <br />N <br />GANG BOX ABOVE <br />EACH SHUTTER, TYPICALLY <br /><6' FROM CONDUIT EXIT <br />FROM SHUTTER HOUSING <br />110v INPUT FROM PANEL, <br />15A CIRCUIT PER RELAY <br />GROUP <br />KEY SWITCH <br />[IF APPLICABLE] <br />FROM PANEL - GROUND - GRN <br />FROM PANEL - LINE - BLK <br />FROM PANEL - NEUTRAL - WHT <br />CTRL PWR TO SW - LINE - BLK <br />DI <br />R <br />1 <br /> <br />F <br />R <br />O <br />M <br /> <br />S <br />W <br /> <br />- <br /> <br />Y <br />E <br />L <br />DIR2 FROM SW - BLUE <br />INDEPENDENT <br />DIRECTIONAL, NEUTRAL, <br />AND GROUND WIRES MUST <br />BE RUN TO EACH MOTOR, <br />DO NOT JOIN TOGETHER <br />MOTOR <br />6 <br />MOTOR <br />5 <br />MOTOR <br />4 <br />MOTOR 1 - DIR2 - BLK <br />MOTOR 1 - DIR1 - RED <br />MOTOR 2 - DIR2 - BLK <br />MOTOR 2 - DIR1 - RED <br />MO <br />T <br />O <br />R <br /> <br />3 <br /> <br />- <br /> <br />D <br />I <br />R <br />2 <br /> <br />- <br /> <br />B <br />L <br />K <br />MO <br />T <br />O <br />R <br /> <br />3 <br /> <br />- <br /> <br />D <br />I <br />R <br />1 <br /> <br />- <br /> <br />R <br />E <br />D <br />MOTOR 3 - NEUTRAL - WHT <br />MOTOR 3 - GROUND - GRN <br />MOTOR 2 - NEUTRAL - WHT <br />MOTOR 2 - GROUND - GRN <br />MO <br />T <br />O <br />R <br /> <br />1 <br /> <br />- <br /> <br />N <br />E <br />U <br />T <br />R <br />A <br />L <br /> <br />- <br /> <br />W <br />H <br />T <br />MO <br />T <br />O <br />R <br /> <br />1 <br /> <br />- <br /> <br />G <br />R <br />O <br />U <br />N <br />D <br /> <br />- <br /> <br />G <br />R <br />N <br />GANG BOX ABOVE <br />EACH SHUTTER, TYPICALLY <br /><6' FROM CONDUIT EXIT <br />FROM SHUTTER HOUSING <br />110v INPUT FROM PANEL, <br />15A CIRCUIT PER RELAY <br />FROM PANEL - GROUND - GRN <br />FROM PANEL - LINE - BLK <br />FROM PANEL - NEUTRAL - WHT <br />INDEPENDENT <br />DIRECTIONAL, NEUTRAL, <br />AND GROUND WIRES MUST <br />BE RUN TO EACH MOTOR, <br />DO NOT JOIN TOGETHER <br />DI <br />R <br />2 <br /> <br /> <br />- <br /> <br />S <br />W <br />I <br />T <br />C <br />H <br /> <br />B <br />U <br />S <br /> <br />B <br />E <br />T <br />W <br />E <br />E <br />N <br /> <br />R <br />E <br />L <br />A <br />Y <br />S <br />DI <br />R <br />1 <br /> <br />- <br /> <br />S <br />W <br />I <br />T <br />C <br />H <br /> <br />B <br />U <br />S <br /> <br />B <br />E <br />T <br />W <br />E <br />E <br />N <br /> <br />R <br />E <br />L <br />A <br />Y <br />S <br />NOTES: <br />1. If the shutter does not move in the intended direction, reverse the black and red directional wires. <br />2. Homerun all motor wires (up and down directionals, neutral, and ground from motor relay board to <br />each shutter motor. <br />3. Do NOT pigtail any motors together. All motor wires (4) must be run from each motor directly to <br />the relay with no junctions or joins. Each motor will require (4) wires (16 AWG MIN) from the <br />motor junction box to the relay junction box. <br />4. Strict adhearance to this schematic is required for proper operation. Installation variance from this <br />drawing will result in damage to the relay boards, motor, or both. <br />5. WARNING: Motors joined together on the same wiring downstream of the relay can cause <br />PERSONAL INJURY. <br />Improperly wired shutters shutters will not stop at their setpoints. <br />6. FOR TECHNICAL SUPPORT, PLEASE CALL QMI 800 446 2500. <br />7. Wiring diagram to be printed in color• ALL WIRES MUST BE 16/4 WIRE HOME RUNS. <br />• ALL WIRING TO BE INSTALLED BY ELECTRICAL CONTRACTOR. <br />4 X 4 PULL BOX, BY ELECTRICAL CONTRACTOR <br />1" Ø CONDUIT TO TELCO ROOM, BY <br />ELECTRICAL CONTRACTOR <br />1/2" Ø SURFACE CONDUIT IF WALL ACCESS IS NOT <br />POSSIBLE, BY ELECTRICAL CONTRACTOR <br />ELECTRICAL CONTRACTOR TO PROVIDE 30" <br />OF WIRE WHIP AT 2X4 J-BOX FOR QMI <br />CONNECTION TO MOTOR, TYP. <br />MANUAL GATE <br />2 X 4 J-BOX (HORIZONTAL) BY ELECTRICAL CONTRACTOR <br />IN WALL CONDUIT OR WIRE, BY ELECTRICAL CONTRACTOR <br />FLEXIBLE CONDUIT WITH COVERPLATE, BY QMI <br />TYP. <br />6" <br />TY <br />P <br />. <br /> <br /> <br />1 <br />3 <br /> <br />" <br />INVENTORY <br />OPEN OFFICE <br />RETAIL SALES <br />J.C.RESTROOM RESTROOM <br />MANAGER <br />TELCO <br />4 X 4 J-BOX, LOCATE HIGH ON WALL, BY <br />ELECTRICAL CONTRACTOR <br />2 X 4 J-BOX (TYP.) MOUNT <br />HORIZONTALLY AT GATE MOTOR <br />LOCATION, BY ELECTRICAL <br />CONTRACTOR <br />1/2" Ø CONDUIT (TYP.) FROM 4 X <br />4 BOX TO GATE MOTOR <br />LOCATIONS. CONDUIT TO BE <br />INSTALLED INSIDE WALL WHEN <br />POSSIBLE, BY ELECTRICAL <br />CONTRACTOR <br />1" Ø CONDUIT, MOUNT HIGH AT <br />ROOF JOISTS, BY ELECTRICAL <br />CONTRACTOR. IF MORE THAN 6 <br />MOTORIZED SHUTTERS ARE <br />REQUIRED, PROVIDE LARGER <br />CONUDIT. <br />MASTER KEY SWITCH SUPPLIED <br />AND INSTALLED BY ELECTRICAL <br />CONTRACTOR. SEE <br />SPECIFICATION <br />POWER FEED TO <br />RELAY PROVIDED BY <br />ELECTRIAL <br />CONTRACTOR <br />RELAY, PROVIDED <br />AND INSTALLED BY <br />QMI <br />ELECTRICAL <br />PANEL <br />CONTROL WIRE ABOVE CEILING <br />FROM RELAY TO KEY SWITCH BY <br />ELECTRICAL CONTRACTOR <br />(3) MOTORS PER <br />RELAY, PROVIDE <br />ADDITIONAL RELAYS <br />AS NEEDED <br />MASTER KEY SWITCH SPECIFICATION <br />HBF-1 KEYED CONTROL <br />TYPE: FLUSH MOUNT KEYSWITCH <br />OPERATION: TWO POSITION (OPEN-CLOSE) <br />BACK BOX: SINGLE GANG <br />FACEPLATE: STAINLESS STEEL <br />FACEPLATE SIZE: 2 3/4" X 4 1/2" <br />CYLINDER: MORTISE TYPE (5 PIN) <br />SIZE: 1 1/8" ⌀X 1" LENGTH <br />SWITCH: 15A @ 125/250 VAC <br />NEMA 1 <br />CORE: BEST OR EQUIVALENT <br />FIRE TREATED PLYWOOD BACKER <br />FINISHED FLOOR <br />NOTES: <br />1. ALL CONNECTIONS IN THE "ONE BOX" ENCLOSURE BY SC <br />2. SEE LOW VOLTAGE DRAWINGS FOR ADDITIONAL INFORMATION <br />3. EC TO HARDWIRE OUTLET INSIDE OF THE "ONE BOX" <br />4. EC TO POWER DOOR BELL FROM THE "ONE BOX" <br />"ONE BOX" ENCLOSURE SUPPLIED <br />BY SC AND INSTALLED BY EC. TOP <br />OF BOX TO BE MOUNTED AT 72" <br />A.F.F. <br />(3) 2" CONDUIT BY EC FOR <br />- CABLE BETWEEN INTRUSION AND LIGHTING CONTROL <br />- ALARM CABLES <br />-ACCESS CONTROL CABLES <br />-DATA FEED <br />CEILING <br />BUSHING, TYP. <br />6' <br /> <br />- <br /> <br />0 <br />" <br />APPROXIMATE LOCATION OF <br />UTILITY BOX WITH DUPLEX OUTLET <br />IN "ONE BOX" TO BE DIRECTLY <br />HARDWIRED BY EC <br />7" <br />3' <br /> <br />- <br /> <br />3 <br />" <br />CL <br />CL <br />1/2" POWER CONDUIT FROM THE <br />"ONE BOX" <br />4" SQUARE JUNCTION BOX WITH <br />DOOR BELL TRANSFORMER <br />MOUNTED TO BOX <br />CONDUIT FOR LOW VOLTAGE <br />WIRING FROM THE DOOR <br />BELL <br />3/4" CONDUIT BY EC FOR CABLE TO FIRE ALARM RELAY (AS <br />REQUIRED) <br />Mechanical and Electrical Engineers <br />Lilker Associates <br />1001 Avenue of the Americas <br />New York, NY 10018 <br />tel 212.695.1000 <br />fax 212.695.1299 <br />www.lilker.com <br />Kenneth A. Gruskin AIA <br />No. Date Description <br />Consultant: <br />Checked By: <br />Drawn By: <br />Job Address: <br />Drawing Title: <br />Revision Issue: <br />Professional Seal: <br />Drawing Number: <br />2024 Gruskin Architecture + Design, P.C.c <br />This document and the ideas and designs incorporated <br />herein, as an instrument of professional service, is the <br />property of GRUSKIN ARCHITECTURE + DESIGN, P.C., <br />and is not to be used in whole or in part for any other <br />project without the written authorization of GRUSKIN <br />ARCHITECTURE + DESIGN, P.C. <br />North <br />Arrow: <br />Job Name and Number: <br />Date Issued For <br />All Rights Reserved <br />Client: <br />Landlord: <br />Permit: <br />Bid: <br />Construction: <br />0006261 <br />AR91629 <br />5421 <br />9613 <br />39209 <br />10635 <br />2537 <br />11016 <br />5734 <br />ARC 2596 <br />4674 <br />2666 <br />AI 09999 <br />2796 <br />0401 011223 <br />2572 <br />17680 <br />RA-015432-B <br />025528-1 NY <br />TX <br />VA <br />VT <br />MA <br />MT <br />RI <br />PA <br />NY <br />NJ <br />NH <br />MD <br />LA <br />ME <br />KS <br />FL <br />DE <br />CT <br />AZ <br />AL <br />C-1967WY <br />RA011075GA <br />AR10400066IN <br />C-29898CA <br />NM 004168 <br />ARC-400347CO <br />HI AR 11489 <br />PR 19965 <br />OR 4899 <br />SC 6834 <br />NC 9961 <br />13761OH <br />05713IA <br />WV 3727 <br />IL 001-019152 <br />UT 5881358-0301 <br />ID AR-984459 <br />1301052379MI <br />ARC100723DC <br />WI 9900-005MN44326 <br />A-3547NE <br />3811AR <br />5967KY 101374TN <br />MS 3860 <br />1666ND <br />A-2005029740MO <br />a4895OK <br />NV 5521 <br />WA 10344 <br />13167AK <br />SD 11532 <br />C: <br />\ <br />R <br />e <br />v <br />i <br />t <br /> <br />L <br />o <br />c <br />a <br />l <br /> <br />F <br />i <br />l <br />e <br />s <br />\ <br />2 <br />4 <br />0 <br />0 <br />1 <br />3 <br />0 <br />8 <br />_ <br />V <br />E <br />R <br />I <br />Z <br />O <br />N <br />_ <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />_ <br />C <br />A <br />_ <br />EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br />_ <br />v <br />2 <br />3 <br />_ <br />D <br />B <br />e <br />l <br />l <br />B <br />R <br />N <br />E <br />Z <br />. <br />r <br />v <br />t <br />2023-0069 <br />Proposed <br />Store Design <br />for: VERIZON <br />Metro Pointe <br />3500 South Bristol Street <br />Suite 100 <br />Santa Ana, CA 92704 <br />3/15/24 <br />3/15/24 <br />TELCO ELEVATIONS AND <br />DETAILS <br />E.2.3 <br />DB <br />MH <br />57 OF 81 <br />3/8" = 1'-0"2 TYPICAL EMS ELEVATION <br />Version: 020221 <br />3/8" = 1'-0"3 TYPICAL BDA ELEVATION <br />Version: 020221 <br />3/8" = 1'-0"4 TYPICAL TELCO RACK ELEVATION <br />Version: 020221 <br />3/16" = 1'-0"5 SHUTTER WIRE REFERENCE DIAGRAM <br />Version: 033021 <br />3/16" = 1'-0"6 SECURITY SHUTTER DIAGRAM (REFERENCE ONLY) <br />Version: 012621 <br />N.T.S. 3/8" = 1'-0"7 TYPICAL SECURITY SHUTTER WIRING ELEVATION DIAGRAM <br />Version: 020221 <br />1/8" = 1'-0"8 TYPICAL SECURITY SHUTTER WIRING PLAN DIAGRAM <br />Version: 020221 <br />3/8" = 1'-0"1 TYPICAL ONE BOX ELEVATION <br />Version: 100521 <br />NOT U <br />S <br />E <br />D <br />3500 S Bristol St Unit# 100 - <br />101119098, 20182666 & <br />401390437/11/2024
The URL can be used to link to this page
Your browser does not support the video tag.