Laserfiche WebLink
LOW HIGH <br />FE <br />FE <br />BOTTLELESS WATER COOLER BY <br />VERIZON. PIPING BY PLUMBING <br />CONTRACTOR. PROVIDE RECESSED <br />VALVE BOX BEHIND (VB-1) AT +12" A.F.F. <br />TO CENTERLINE. <br />LAMINATE COUNTER WITH <br />CABINETS ABOVE AND <br />BELOW. SEE SHEET A.4.0 <br />FLOOR MOUNTED JANITOR SINK, SEE <br />PLUMBING PLAN FOR SPEC. <br />NEW TENANT DEMISING PARTITION, RUN <br />TO UNDERSIDE OF DECK ABOVE. <br />PROVIDE TYPE 5/8" 'X' GYPSUM BOARD <br />ON BOTH SIDES (1- HOUR FIRE RATED <br />WALL) SEE DETAIL 3/A.5.0. <br />PROVIDE AN INTERNATIONAL <br />ACCESSIBILITY SYMBOL. SEE <br />SHEET G.2.0. <br />PROVIDE DIRECTIONAL SIGNAGE TO ACCESSIBLE RESTROOM <br />AS PER CODE. SEE DETAIL 7/G.2.0. <br />LINE OF CLEAR FLOOR SPACE. SEE <br />ACCESSIBILITY DETAILS ON SHEET G.2.0. <br />LINE OF 5'-0" ∅WHEELCHAIR TURNING SPACE. SEE <br />ACCESSIBILITY DETAILS ON SHEET G.2.0. <br />PROVIDE A TACTILE EXIT SIGN WITH THE <br />WORD "EXIT." SEE SHEET G.2.0 <br />MOTORIZED SECURITY SHUTTERS BEHIND <br />STOREFRONT WINDOWS AND GLASS <br />ENTRY DOORS (TYP.). SEE SECURITY <br />SHUTTER NOTES. <br />PROVIDE VISIBLE DURABLE SIGN ON OR ADJACENT TO THE <br />DOOR STATING "THIS DOOR MUST REMAIN UNLOCKED WHEN <br />BUILDING IS OCCUPIED". THIS SIGN SHALL BE LETTERS NOT <br />LESS THAN 1 INCH HIGH ON A CONTRASTING BACKGROUND. <br />FIRE EXTINGUISHER WITH CABINET, RECESSED IN WALL <br />NEW DOOR. CONTRACTOR SHALL PROVIDE HINGES AT DOOR WHICH WILL NOT ALLOW <br />REMOVAL OF HINGE PIN WHEN DOOR IS IN LOCKED POSITION. STEEL PINS SHALL BE SET IN <br />DOOR WHICH ENGAGE FRAME WHEN DOOR IS CLOSED. <br />WALL MOUNTED FIRE EXTINGUISHER <br />PROVIDED BY GENERAL CONTRACTOR.. <br />STORAGE CABINET <br />DRINKING FOUNTAIN. PIPING BY PLUMBING <br />CONTRACTOR. SEE PLUMBING PLAN. <br />NEW ELECTRICAL PANELS, SEE ELECTRICAL PLANS <br />PROVIDE (1) LAYER 3/4" CDX FIRE <br />RETARDANT PLYWOOD ON ALL WALLS, <br />FULL HEIGHT OF ROOM. <br />PLYWOOD SHALL BE PRIMED AND PAINTED. <br />CONTRACTOR SHALL PROVIDE 1/2" THICK CORIAN <br />TOP AT MODIFIED SILL. SEE DETAIL 8/A.5.0 <br />FOR TELCO LAYOUT, SEE ELECTRICAL <br />DRAWINGS FOR MORE INFORMATION. <br />SOLAR FILM ON INSIDE FACE OF ALL <br />EXTERIOR WINDOWS BY GENERAL <br />CONTRACTOR. SEE NOTES. <br />DOOR DESIGNATION, SEE <br />DOOR SCHEDULE, SHEET A.6.0 <br />ALIGN <br />FINISHES <br />PROVIDE (2) 4X8 PRECAST CONCRETE <br />LINTELS WITH 8" MINIMUM BEARING <br />EACH END. <br />FURR OUT WALL <br />CORNER, ALIGN <br />FINISHES <br />NEW 3'-0" x 8'-0" ALUMINUM AND GLASS ENTRY <br />DOORS, SEE GENERAL NOTES FOR SPECIFICATION. <br />PANIC HARDWARE BY SECURITY VENDOR (TYP.) <br />INFILL EXISTING ENTRY DOOR WITH <br />1" INSULATED GLAZING. MULLIONS TO MATCH <br />EXISTING. SEE GENERAL NOTES FOR <br />SPECIFICATIONS <br />PROVIDE METAL STRAPPING <br />ON STUDS FOR DEVICE <br />DISPLAY FIXTURE. SEE <br />FURNITURE PLAN FOR <br />FIXTURE LAYOUT AND DETAIL <br />2/A.3.2 FOR STRAPPING <br />MOUNTING HEIGHT (TYP.). <br />WALL MOUNTED SMART BOARD @ <br />62" A.F.F. O.C. PROVIDE <br />BLOCKING 8" HIGH 20 GA <br />HORIZONTAL STRAPPING ON <br />STUDS. REFER TO DETAIL 6/A.3.2. <br />PROVIDE (1) LAYER 3/4" CDX FIRE <br />RETARDANT PLYWOOD, FULL HEIGHT <br />TO DECK ABOVE. PROVIDE (1) <br />LAYER OF GYP BD ON PLYWOOD UP <br />TO 6" ABOVE CEILING (TYP. ON ALL <br />WALLS IN INVENTORY U.O.N.) <br />RECESSED SLATWALL, SEE DETAIL 2/A.5.0 <br />CONTRACTOR SHALL PROVIDE SHELF <br />BELOW CEILING FOR WATER HEATER <br />SUPPORT, SEE PLUMBING PLANS. BOTTOM <br />OF SHELF TO BE 7'-0" A.F.F. <br />HOLD <br />37'-9 3/4" <br />(FINISHED OPENING) <br />5'-0" <br />RETAIL SALES <br />101 <br />RESTROOM <br />102 <br />RESTROOM <br />103 <br />OPEN OFFICE <br />104 <br />INVENTORY <br />105 <br />MANAGER <br />106 <br />J.C. <br />107 <br />TELCO <br />108 <br />A.3.1 <br />2 <br />FI <br />N <br /> <br />H <br />O <br />L <br />D <br />8" <br />9'-1 1/4" <br />EX. FIN. TO FRAME <br />2'-1 5/8" <br />3 5/8" <br />A.4.02 <br />3 5/8" <br />EX. FIN. <br />T <br />O FR <br />A <br />M <br />E <br />2'-1 <br />5 <br />/ <br />8 <br />" <br />3 5/8" <br />11'-8 <br />1/2"3 5/8" <br />3 5/8" <br />6'-7 3/8" <br />3 5/8" <br />(FIN) <br />2'-8 5/8" <br />3 5/8" <br />7'-6 1/4" <br />3 5/8" <br />7'-6 1/4" <br />3 5/8" <br />± 7'-2 1/4" <br />MI <br />N <br />. <br />(F <br />I <br />N <br />) <br />1' <br />- <br />2 <br />" <br />7' <br />- <br />1 <br /> <br />1 <br />/ <br />4 <br />" <br />3 <br />5 <br />/ <br />8 <br />" <br />14 <br />' <br />- <br />9 <br />" <br /> <br />( <br />T <br />O <br /> <br />L <br />E <br />A <br />S <br />E <br /> <br />L <br />I <br />N <br />E <br />) <br />9' <br />- <br />3 <br /> <br />1 <br />/ <br />4 <br />" <br />3 <br />5 <br />/ <br />8 <br />" <br />18 <br />' <br />- <br />7 <br /> <br />1 <br />/ <br />4 <br />" <br />3 <br />5 <br />/ <br />8 <br />" <br />FIN. <br />1'-0" <br />FIN. <br />3'-4" CLR <br />3'-0" <br />A.4.0 <br />1 <br />1'-3" <br />2'-7" <br />7'-9 1/4" <br />EX. FIN. TO FRAME <br />2'-1 5/8" <br />A.3.1 <br />4EXISTING STAIR <br />(N.I.C.) <br />FUTURE TENANT <br />(N.I.C.) <br />EXISTING STOREFRONT <br />TO REMAIN. <br />EXISTING STOREFRONT <br />TO REMAIN. <br />EXSITING EXTERIOR <br />WALL TO REMAIN, TYP. <br />EXISTING STOREFRONT <br />AND ENTRY DOORS TO <br />REMAIN (N.I.C.) <br />2 3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />TO REMAIN <br />EXISTING STOREFRONT <br />3 5/8" <br />FI <br />N <br />. <br />5' <br />- <br />4 <br />" <br />CL <br />EQ <br />. <br />EQ <br />. <br />CL <br />APPROXIMATE LOCATION OF <br />NEW LEASE LINE <br />PROVIDE COOL GRAY 10 WINDOW FILM AT <br />THESE STOREFRONTS ONLY (EXISTING <br />SOREFRONT TO REMAIN) <br />PROVIDE METAL STRAPPING ON STUDS FOR 2-XX/4-XX <br />FIXTUES. SEE FURNITURE PLAN FOR FIXTURE LAYOUT AND <br />DETAIL 1/A.3.2 FOR STRAPPING MOUNTING HEIGHT (TYP.) <br />PROVIDE METAL STRAPPING ON <br />STUDS FOR 2-XX/4-XX FIXTUES. SEE <br />FURNITURE PLAN FOR FIXTURE <br />LAYOUT AND DETAIL 1/A.3.2 FOR <br />STRAPPING MOUNTING HEIGHT (TYP.) <br />MODIFIED PLANTER, SEE <br />DETAIL 9/A.5.0 <br />1 <br />1 <br />4A <br />4A <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />2 <br />LAMINATE COUNTER WITH CABINETS ABOVE <br />AND BELOW. SEE SHEET A.4.0. <br />A.3.1 <br />3 <br />A.3.1 <br />1 <br />A.4.0 <br />3 <br />A.3.3 <br />1 <br />6A <br />6A <br />COOL GRAY 10 WINDOW FILM COOL GRAY 10 WINDOW FILM <br />DEMISING WALL TO START AT CORNER OF <br />EXISTING PERIMETER WALL <br />CL <br />CL <br />6 <br />LAVLAVWCWC <br />PS <br />MS <br />FURR EXISTING COLUMN WITH 2 1/2" <br />STUDS AND 5/8" GYPSUM BOARD <br />4A <br />4A <br />NO PLYWOOD <br />REQUIRED AT <br />STAIR WALL <br />4A <br />EXISTING COLUMN TO REMAIN, <br />PATCH ANY HOLES PRIOR TO <br />PAINTING <br />FIN. <br />8" <br />A.3.2 <br />4 <br />1 <br />NEW STOREFRONT <br />15'-11" <br />1 <br />EXISTING OVERHANG TO <br />REMAIN, TYP. <br />3 5/8" <br />FURR OUT CORNER <br />12" MIN. <br />2'-0" <br />V. <br />I <br />. <br />F <br />. <br />24 <br />' <br />- <br />4 <br /> <br />3 <br />/ <br />4 <br />" <br />V.I.F. <br />24'-3 9/16" <br />T <br />THERMOSTAT. <br />THERMOSTAT. <br />T <br />S <br />REMOTE SENSOR FOR T-STAT <br />ALIGN FINISHES <br />3 5/8" <br />CLR. <br />14 <br />' <br />- <br />7 <br /> <br />3 <br />/ <br />1 <br />6 <br />" <br /> <br />F <br />R <br />A <br />M <br />E <br /> <br />T <br />O <br /> <br />E <br />X <br />. <br /> <br />F <br />I <br />N <br />. <br />3 <br />5 <br />/ <br />8 <br />" <br />90° <br />9 <br />A.5.0 <br />ALIGN CAP OF PLANTER <br />WALL TO EDGE OF MULLION <br />A.3.0 <br />1 <br />A.3.02 <br />A.3.03 <br />A.3.0 <br />4 <br />8 <br />A.5.0 <br />AT REAR DOOR, PROVIDE 4" THICK <br />CONCRETE LANDING FLUSH WITH DOOR, <br />HAUNCH EDGES DOWN TO 6" BELOW <br />PAVEMENT. PROVIDE GRAVEL AS REQIRED. <br />5' <br />- <br />0 <br />" <br />1'-10"8" <br />NOTE: <br />ATTACH BOTTOM OF BRACE TO TOP TRACK OF <br />WALL WITH (3) #8 SHEET METAL SCREWS EACH <br />BRACE. DO NOT ATTACH THROUGH CEILING TILE. <br />ICC-ES # FOR METAL STUDS.........ESR-4205 <br />(STUDS SHALL BE PER "STEEL STUD <br />MANUFACTURERS ASSOCIATION") <br />ICC-ES # FOR FASTENERS..........ER-3056 <br />(ITW "SHEET METAL" BUILDEX SCREWS) <br />ICC-ES # FOR SHOT PINS..........ESR-1663 <br />(.145" ∅POWDER DRIVEN HILTI PINS) <br />WALLS SHALL BE HORIZONTALLY AND LATERALLY <br />BRACED AS PER SEISMIC CODE ZONE 4. <br />ALL PROPOSED CONSTRUCTION, ALTERATION OR <br />DEMOLITION SHALL BE IN ACCORDANCE WITH THE <br />2022 CFC. <br />DECORATIVE MATERIALS SHALL BE MAINTAINED IN A <br />FLAME RETARDANT CONDITION IN ACCORDANCE <br />WITH THE 2022 CFC. <br />FIRE CODE NOTES: <br />FIRE EXTINGUISHERS SHALL BE 2A10 BC TYPE AND <br />SHALL CONFORM TO CHAPTERS 9 & 10 OF THE 2022 <br />CFC (CALIFORNIA FIRE CODE). <br />VERIZON SHALL POST "NO SMOKING" SIGNS AS PER <br />CALIFORNIA STATE LABOR CODE. <br />(IF APPLICABLE) FIRE ALARM PLANS AND ANY OTHER <br />FIRE PROTECTION SYSTEM PLANS SHALL BE <br />SUBMITTED TO FIRE AND LIFE SAFETY FOR REVIEW <br />AND APPROVAL PRIOR TO INSTALLATION PER THE <br />2022 CFC. <br />SECURITY SHUTTERS NOTE: <br />CONTRACTOR SHALL INSTALL NEW SECURITY SHUTTERS <br />BEHIND ALL STOREFRONT WINDOWS AND GLASS ENTRY <br />DOORS. SECURITY SHUTTERS SHALL BE MODEL # AL7- <br />E, PUNCH STYLE 51 BY QMI, W/ END RETENTION CLEAR <br />ANODIZED CURTAIN RAIL AND HOUSING TO <br />COMPLEMENT OR MATCH STOREFRONT. SHUTTERS <br />SHALL BE MOTORIZED AT STOREFRONT WINDOWS AND <br />MANUAL WITH THUMB TURN AT ENTRANCE DOORS. <br />PROVIDE BEST CONSTRUCTION CORE LOCK. QMI <br />SHALL BE RESPONSIBLE FOR FIELD DIMENSIONS AND <br />FINAL INSTALLATION. <br />GENERAL CONTRACTOR SHALL CONTACT KEVIN <br />BECERRA AT (800) 446-2500. <br />KBECERRA@QMIUSA.COM GENERAL CONTRACTOR <br />MUST REFERENCE THAT THIS DOOR IS FOR A VERIZON <br />PROJECT. <br />NOTE: <br />FREESTANDING FIXTURES ARE SHOWN FOR CLARITY <br />FOR FLOOR SLAB DEMOLITION. PLEASE REFER TO <br />ELECTRICAL PLANS FOR FLOOR BOX LOCATIONS AND <br />FURNITURE PLANS FOR FIXTURE LOCATIONS. <br />ARCHITECTURAL NOTES: <br />1. ALL NEW WALLS SHALL BE 3-5/8" OR 6" (20 GAUGE) METAL STUDS AT 16" O.C. WITH <br />5/8" GYPSUM BOARD BOTH SIDES AND FULL INSULATION, UNLESS OTHERWISE NOTED. <br />2. RATED WALL CONSTRUCTION SHALL BE 3 5/8" METAL STUDS AT 16" O.C. WITH (1) <br />LAYER 5/8" TYPE 'X' GYPSUM BOARD BOTH SIDES, FULL HEIGHT TO UNDERSIDE OF <br />STRUCTURE ABOVE AND FULL INSULATION. U.L. DESIGN NO. U419. <br />3. ALL NEW WALLS SHALL EXTEND 6" ABOVE SUSPENDED CEILING, UNLESS OTHERWISE <br />NOTED. <br />4. ALL DIMENSIONS ARE FRAMING DIMENSIONS, UNLESS OTHERWISE NOTED. <br />5. ALL NEW DOORS SHALL BE 4" OFF WALL (AT HINGE SIDE), UNLESS OTHERWISE NOTED. <br />6. CONTRACTOR SHALL PAINT ALL DOORS UNLESS OTHERWOSE NOTED. SEE FINISH <br />SCHEDULE. <br />7. PROVIDE (2) ROWS MINIMUM 8" HIGH, 20 GAUGE HORIZONTAL STRAPPING ON STUDS <br />AT ALL WALLS WITH CABINETS. <br />8. ANY DRYWALL FINISH WHICH IS EXISTING TO REMAIN SHALL BE PATCHED, PRIMED AND <br />PAINTED TO LEVEL 5 CONDITION AND TO ACCEPT NEW FINISHES. CONTRACTOR <br />SHALL DETERMINE BEST METHODS FOR PATCHING, OR IF DRYWALL WILL NEED TO BE <br />REMOVED OR REPLACED TO ACHIEVE DESIRED FINISH. EXAMPLE: PATCH DRYWALL <br />WHERE ITEMS ARE REMOVED SUCH AS, BUT NOT LIMITED TO, ELECTRICAL BOXES, <br />TRIM, MIRRORS, DOOR JAMBS, WALLCOVERING, ETC. <br />9. IT IS THE CONTRACTOR’S RESPONSIBILITY TO SMOOTH ALL ROUGH SURFACES ON <br />FLOORS OR PATCH, FILL OR FLOAT EXISTING FLOORS TO A SMOOTH CONDITION <br />CAPABLE OF RECEIVING NEW FINISHED FLOOR COVERING. EXAMPLE: AT ALL <br />REMOVED WALL AREAS, STRIPPED MATERIAL LOCATIONS (I.E. VINYL TILE, CERAMIC <br />TILE, CARPET, ETC.), CONDUIT FEEDS AND CHIPPED CONCRETE, ETC. <br />10. PATCH AND LEVEL EXISTING CONCRETE SLAB AS REQUIRED FOR NEW FINISHES. <br />11. CONTRACTOR SHALL PROVIDE OPTIONAL PRICING TO LEVEL OR SMOOTH FLOORS <br />THAT HAVE DEPRESSIONS OR DIPS GREATER THAN 1" WITH GYPCRETE OR OTHER <br />SELF-LEVELING COMPOUND. <br />12. G.C. SHALL CONTACT VERIZON PROJECT MANAGER TO OBTAIN AND ORDER ALL <br />LIGHT FIXTURES. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. <br />13. PATCH ALL EXISTING WALLS AS REQUIRED DUE TO NEW WORK. <br />14. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF THE EXISTING COLUMN <br />LOCATIONS AND SIZES ARE DIFFERENT FROM WHAT OCCURS IN THESE DRAWINGS, <br />AND OF ANY UNDOCUMENTED STRUCTURAL COLUMNS OR CONDITIONS, PIPES, ETC., <br />WHICH ARE LOCATED IN THE TENANT SPACE BUT DO NOT APPEAR IN THESE <br />DRAWINGS, SO THE DRAWINGS CAN BE REVISED TO ACCOMMODATE THE AS-BUILT <br />CONDITIONS. <br />15. CONTRACTOR SHALL PROVIDE FIRE RATED BLOCKING/PLYWOOD AT THE <br />FOLLOWING LOCATIONS: TELCO RACK, GRAB BARS, HANDRAILS, WALL HUNG <br />FURNITURE, WALL HUNG CABINETS AND SHELVES, HANGING GLASS WINDOW DISPLAYS <br />AT STOREFRONTS, HANGING POSTERS AND AT ALL OTHER LOCATIONS WHERE <br />EQUIPMENT IS BEING WALL OR CEILING/SOFFIT HUNG. <br />16. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO CUT AND PATCH SLAB AS <br />REQUIRED FOR NEW UNDER SLAB. ELECTRICAL CONDUITS. SEE ELECTRICAL PLANS. <br />17. ALL SAW CUTS SHALL BE DOWELED, ALTERNATING SIDES AT 18", OR AS PER CODE, <br />PRIOR TO POUR BACK. <br />18. NEW RESTROOMS. CONTRACTOR SHALL LOCATE (2) SINK-1, (1) SINK-2, (2) WC-1 AND <br />ACCESSORIES TO COMPLY WITH ADA AND ANSI. SEE ACCESSIBILITY DETAILS ON <br />SHEET G.2.0. SAW CUT SLAB AS REQUIRED FOR PLUMBING LINES <br />19. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO SAW CUT AND REMOVE <br />EXISTING CONCRETE SLAB FOR TRENCHING AS REQUIRED FOR NEW PLUMBING <br />FIXTURES; COORDINATE WITH PLUMBING CONTRACTORS TO IDENTIFY PRECISE <br />LOCATIONS AND DEPTH IN FIELD AS REQUIRED. VERIFY ALL OR ANY STRUCTURAL <br />MEMBERS WHICH MAY INTERFERE WITH TRENCH. EXCAVATE ADDITIONAL TRENCH AS <br />REQUIRED TO CONNECT NEW SOIL LINES TO EXISTING MAIN, V.I.F., VERIFY WITH <br />LANDLORD AND EXISTING BUILDING SYSTEM FOR PRECISE LOCATION AND <br />DIRECTION. SEE PLUMBING PLANS. <br />20. CONTRACTOR SHALL COORDINATE WITH VERIZON PROJECT MANAGER FOR <br />TEMPORARY CONSTRUCTION SIGNAGE FOR ALL WINDOWS. <br />21. CONTRACTOR SHALL NOT INSTALL GYPSUM BOARD BEHIND SLATWALL IN INVENTORY <br />ROOM. <br />22. SEE DETAIL 6/A.5.0 FOR SECURITY SHUTTERS AT BOH, AND DETAIL 7/A.5.0 FOR <br />SECURITY SHUTTERS AT FRONT OF HOUSE. SHUTTERS TO BE MOTORIZED EXCEPT AT <br />ENTRY DOORS. <br />EXISTING WALL TO REMAIN <br />1 3 5/8" METAL STUD WITH 5/8" GYPSUM <br />BOARD BOTH SIDES, UP TO 6" ABOVE <br />ACT. WITH FULL BATT INSULATION. <br />SEE DETAIL 1/A.5.0 <br />WALL TYPES LEGEND: <br />3 5/8" METAL STUD WITH 5/8" GYPSUM BOARD <br />ON NON-TELCO SIDE AND 5/8" GYPSUM BOARD <br />ON 3/4" CDX PLYWOOD ON TELCO SIDE, UP TO <br />6" ABOVE ACT. WITH FULL BATT INSULATION. <br />SEE DETAIL 1/A.5.0 <br />2 <br />4A <br />6 <br />3 5/8" METAL STUD @ 8" O.C. WITH 5/8" GYPSUM <br />BOARD ON NON-INVENTORY SIDE AND 5/8" <br />GYPSUM BOARD UP TO 6" ABOVE ACT ON 3/4" <br />CDX PLYWOOD UP TO DECK ABOVE ON <br />INVENTORY SIDE, WITH FULL BATT INSULATION. <br />SEE DETAIL <br />3 5/8" METAL STUD WITH 5/8" GYPSUM BOARD <br />BOTH SIDES, UP TO STRUCTURE ABOVE WITH <br />FULL BATT INSULATION. 1 HOUR RATED WALL <br />(U.L. DESIGNATION U419). <br />SEE DETAIL 3/A.5.0 <br />/2 A.5.0 <br />6A 3 5/8" METAL STUD WITH 5/8" GYPSUM BOARD <br />BOTH SIDES, UP TO STRUCTURE ABOVE WITH <br />FULL BATT INSULATION. 1 HOUR RATED WALL <br />(U.L. DESIGNATION U419). PROVIDE 3/4 CDX <br />PLYWOOD UP TO 6" ABOVE CEILING. <br />SEE DETAIL 3/A.5.0 <br />1/4" = 1'-0"1 ARCHITECTURAL PLAN <br />Kenneth A. Gruskin AIA <br />No. Date Description <br />Consultant: <br />Checked By: <br />Drawn By: <br />Job Address: <br />Drawing Title: <br />Revision Issue: <br />Professional Seal: <br />Drawing Number: <br />2024 Gruskin Architecture + Design, P.C.c <br />This document and the ideas and designs incorporated <br />herein, as an instrument of professional service, is the <br />property of GRUSKIN ARCHITECTURE + DESIGN, P.C., <br />and is not to be used in whole or in part for any other <br />project without the written authorization of GRUSKIN <br />ARCHITECTURE + DESIGN, P.C. <br />North <br />Arrow: <br />Job Name and Number: <br />Date Issued For <br />All Rights Reserved <br />Client: <br />Landlord: <br />Permit: <br />Bid: <br />Construction: <br />0006261 <br />AR91629 <br />5421 <br />9613 <br />39209 <br />10635 <br />2537 <br />11016 <br />5734 <br />ARC 2596 <br />4674 <br />2666 <br />AI 09999 <br />2796 <br />0401 011223 <br />2572 <br />17680 <br />RA-015432-B <br />025528-1 NY <br />TX <br />VA <br />VT <br />MA <br />MT <br />RI <br />PA <br />NY <br />NJ <br />NH <br />MD <br />LA <br />ME <br />KS <br />FL <br />DE <br />CT <br />AZ <br />AL <br />C-1967WY <br />RA011075GA <br />AR10400066IN <br />C 29898CA <br />NM 004168 <br />ARC-400347CO <br />HI AR 11489 <br />PR 19965 <br />OR 4899 <br />SC 6834 <br />NC 9961 <br />13761OH <br />05713IA <br />WV 3727 <br />IL 001-019152 <br />UT 5881358-0301 <br />ID AR-984459 <br />1301052379MI <br />ARC100723DC <br />WI 9900-005MN 44326 <br />A-3547NE <br />3811AR <br />5967KY 101374TN <br />MS 3860 <br />1666ND <br />A-2005029740MO <br />a4895OK <br />NV 5521 <br />WA 10344 <br />13167AK <br />SD 11532 <br />J: <br />\ <br />V <br />e <br />r <br />i <br />z <br />o <br />n <br />\ <br />0 <br />0 <br /> <br />S <br />t <br />o <br />r <br />e <br />s <br /> <br />b <br />y <br /> <br />S <br />t <br />a <br />t <br />e <br />\ <br />C <br />a <br />l <br />i <br />f <br />o <br />r <br />n <br />i <br />a <br />\ <br />2 <br />0 <br />2 <br />3 <br />- <br />0 <br />0 <br />6 <br />9 <br /> <br />M <br />e <br />t <br />r <br />o <br /> <br />P <br />o <br />i <br />n <br />t <br />e <br />- <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br />\ <br />2 <br />. <br />D <br />r <br />a <br />w <br />i <br />n <br />g <br />s <br />\ <br />2 <br />. <br />4 <br /> <br />C <br />D <br />\ <br />0 <br />0 <br />- <br />2 <br />0 <br />2 <br />3 <br />- <br />0 <br />0 <br />6 <br />9 <br />- <br />C <br />u <br />r <br />r <br />e <br />n <br />t <br />\ <br />2 <br />0 <br />2 <br />3 <br />- <br />0 <br />0 <br />6 <br />9 <br />- <br />B <br />I <br />M <br />2 <br />3 <br />. <br />r <br />v <br />t <br />2023-0069 <br />Proposed <br />Store Design <br />for: VERIZON <br />Metro Pointe <br />3500 South Bristol Street <br />Suite 100 <br />Santa Ana, CA 92704 <br />3/15/24 <br />3/15/24 <br />ARCHITECTURE PLAN <br />AND WALL TYPES <br />A.1.0 <br />MB <br />KG <br />11 OF 81 <br />3500 S Bristol St Unit# 100 - <br />101119098, 20182666 & <br />401390437/11/2024