Laserfiche WebLink
23XX <br />26575 Ruether Ave 2nd floor <br />CH <br />A <br />R <br />C <br />Santa Clarita, CA 91350 <br />661.383.2352 - 818.919.2248 <br />VFD VARIABLE FREQUENCY DRIVE <br />WT <br />WP <br />WATERTIGHT, WEIGHT <br />WEATHER PROOF <br />UNLESS OTHERWISE NOTED <br />UNINTERRUPTIBLE POWER SUPPLY <br />VOLT <br />VOLT-AMPERE <br />VACUUM <br />VERTICAL <br />VELOCITY <br />VENT THROUGH ROOF <br />VITRIFIED CLAY PIPE <br />VARIABLE AIR VOLUME <br />VOLUME DAMPER <br />UNDERWRITERS LABORATORIES, INC. <br />WITH <br />WATT, WIDTH <br />WITHOUT <br />WET BULB <br />WATER PRESSURE DROP <br />TRANSFORMER <br />UON <br />UPS <br />UL <br />VAC <br />VA <br />V <br />VD <br />VEL <br />VTR <br />VERT <br />VCP <br />VAV <br />W <br />W/ <br />W/O <br />WPD <br />WB <br />XFMR <br />SOUND LINED(SL) <br />TSTAT <br />TEMP <br />INCHES OF WATER COLUMNIN WC <br />SERVICE SINK <br />STRUC STRUCTURAL <br />POINT OF DISCONNECTIONPOD <br />POC POINT OF CONNECTION <br />AHU AIR HANDLING UNIT <br />GRAVITY VENTILATORGV <br />FC FAN COIL <br />RTU ROOFTOP UNIT <br />EF EXHAUST FAN <br />FPI FINS PER INCH <br />PRESS PRESSURE <br />EXT EXTERNAL <br />OSA OUTSIDE AIR <br />APD <br />DISCH DISCHARGE <br />SYM SYMBOL <br />PLUMBING <br />PANEL <br />POUNDS PER SQUARE INCH <br />POUNDS PER SQUARE FOOT <br />POLYVINYL CHLORIDE <br />POUNDS PER SQUARE INCH GAUGE <br />POUNDS PER SQUARE INCH ABSOLUTE <br />QUANTITY <br />ROOF DRAIN <br />REINFORCING <br />RECIRCULATE <br />RETURN AIR <br />REINFORCED CONCRETE PIPE <br />REFLECTED CEILING PLAN, <br />REFERENCE, REFER <br />REQUIRED <br />ROOM <br />REVOLUTIONS PER MINUTE <br />REFRIGERANT LIQUID <br />REFRIGERANT SUCTION <br />REVISION, REVISE <br />SQUARE FEET <br />SUPPLY AIR <br />SIMILAR <br />SHEET <br />SECTION <br />SPECIFICATION <br />SHEET METAL <br />CONDITIONING CONTRACTOR'S <br />NATIONAL ASSOCIATION <br />STATIC PRESSURE <br />SMOKE DAMPER, STORM DRAIN <br />SHEET METAL AND AIR <br />SURFACE <br />SUSPEND <br />STANDARD <br />STEEL <br />THROUGH <br />SOUND TRAP, STEAM TRAP <br />TOTAL PRESSURE <br />TOTAL DYNAMIC HEAD <br />SQUARE <br />STAINLESS STEEL, SANITARY SEWER, <br />PSIA <br />PSIG <br />PLBG <br />PSF <br />PSI <br />PNL <br />PVC <br />GAUGE <br />GALLON <br />GA <br />GAL <br />HEIGHTH <br />GPH <br />GPM <br />GC <br />GALV <br />GPD <br />GALVANIZED <br />GALLONS PER DAY <br />GALLONS PER HOUR <br />GENERAL CONTRACTOR <br />GALLONS PER MINUTE <br />AIR PRESSURE DROP <br />AMPERES <br />ABOVE FINISHED GRADE <br />ABOVE FINISHED FLOOR <br />ABOVE FINISHED CEILING <br />ARCHITECT, ARCHITECTURAL <br />ADJUSTABLE <br />AFF <br />AFG <br />ARCH <br />ANSI <br />AMPS <br />ACCU <br />AFC <br />ADJ <br />AIR COOLED CONDENSING UNIT <br />AMERICAN NATIONAL STANDARDS INSTITUTE <br />QTY <br />RD <br />RE: <br />REINF <br />RA <br />RCP <br />RL <br />REV <br />REQD <br />RPM <br />RS <br />RM <br />HEATING <br />HEATER <br />HERTZ <br />HW <br />HZ <br />HORIZ <br />HP <br />HOA <br />HVAC <br />HTR <br />HTG <br />INCH <br />ID <br />IE <br />IN <br />(IN WG)INCHES WATER GAUGE <br />HORSEPOWER, HEAT PUMP <br />HORIZONTAL <br />HOT WATER <br />INSIDE DIAMETER <br />INVERT ELEVATION <br />HAND-OFF-AUTOMATIC <br />HEATING, VENTILATING AND <br />SF <br />SIM <br />SHT <br />SA <br />SECT <br />SD <br />SPEC <br />SP <br />SURF <br />SUSP <br />SS <br />ST <br />STL <br />STD <br />TP <br />THRU <br />TDH <br />SQ <br />KILOWATT <br />KILOVOLTKV <br />KWH <br />KVA <br />KW <br />LENGTH <br />POUND(S) <br />LIGHTING <br />L <br />LF <br />LAT <br />LRA <br />LDB <br />LB(S),# <br />LTG <br />LWB <br />LSTM <br />KILOWATT-HOUR <br />KILOVOLT-AMPS <br />LINEAR FEET <br />LEAVING DRY BULB <br />LEAVING WET BULB <br />LEAVING AIR TEMPERATURE <br />LOCKED ROTOR AMPS <br />LOW PRESSURE STEAM (15 PSIG) <br />AND AIR CONDITIONING ENGINEERS <br />AUXILIARY <br />BUILDING <br />BACKDRAFT DAMPER <br />BOTTOM OF PIPE <br />BOTTOM OF DUCT <br />BOTTOM OF STRUCTURE <br />BDD <br />BOD <br />BOP <br />BOS <br />BLDG <br />ASHRAE <br />ASME <br />ASTM <br />AUX <br />BRITISH THERMAL UNIT <br />CUBIC FEET PER SECOND <br />CUBIC FEET PER MINUTE <br />CUBIC FEET PER HOUR <br />CIRCUIT <br />CEILING <br />CONDENSING UNIT <br />COLUMN <br />CONCRETE MASONRY UNIT <br />COLD WATER <br />CLEANOUT <br />CENTERLINE <br />CIRCULATING <br />COL <br />CW <br />CU <br />CO <br />CKT <br />CIRC <br />LC <br />CFH <br />CFM <br />CFS <br />CLG <br />CMU <br />BTU <br />AMERICAN SOCIETY OF HEATING, REFRIGERATION <br />AMERICAN SOCIETY OF TESTING AND MATERIALS <br />AMERICAN SOCIETY OF MECHANICAL ENGINEERS <br />AIR CONDITIONING AND REFRIGERATION INSTITUTEARI <br />SHT MTL <br />SMACNA <br />RECIRC <br />THERMOSTAT <br />TYPICAL <br />UNDERSLAB <br />UNDERGROUND <br />UNDERFLOOR <br />TOTAL STATIC PRESSURETSP <br />TYP <br />U/S <br />U/F <br />U/G <br />MAXIMUM <br />LWT <br />MECH <br />MFR <br />MD <br />MAX <br />MBH <br />MCA <br />MOUNTED <br />MINIMUM <br />NEMA <br />N/A <br />NC <br />NEC <br />MIN <br />MTD <br />LEAVING WATER TEMPERATURE <br />MECHANICAL <br />MANUFACTURER <br />MOTORIZED DAMPER <br />NOT APPLICABLE <br />MINIMUM CIRCUIT AMPACITY <br />1000 BTU PER HOUR <br />NATIONAL ELECTRICAL CODE <br />NOISE CRITERIA, NORMALLY CLOSED <br />NATIONAL ELECTRICAL <br />OBD <br />OD <br />OC <br />OA <br />NFPA <br />N.O. <br />NTS <br />NIC <br />OPENING <br />OVERHEAD <br />OSHA <br />OH <br />OPNG <br />ON CENTER <br />OUTSIDE AIR <br />OUTSIDE DIAMETER <br />OPPOSED BLADE DAMPER <br />OCCUPATIONAL SAFETY <br />NORMALLY OPEN <br />NOT TO SCALE <br />NOT IN CONTRACT <br />ASSOCIATION <br />NATIONAL FIRE PROTECTION <br />MANUFACTURER'S ASSOCIATION <br />DECIBEL <br />DOWN <br />DIAMETER <br />DEGREES <br />DISCONNECT <br />DIMENSION <br />DRY BULB <br />DRAWING(S) <br />EXHAUST AIR, EACH <br />DIRECT EXPANSION <br />ENTERING DRY BULB <br />ENTERING AIR TEMPERATURE <br />ECCENTRIC <br />EAT <br />EDB <br />ECC <br />EA <br />DISC <br />DN <br />DIM <br />DWG(S) <br />DX <br />dB <br />DB <br />DEG <br />DIA <br />EXISTING <br />EXHAUST <br />ENTERING WET BULB <br />EXTERNAL STATIC PRESSURE <br />EFFICIENCY <br />ELECTRICAL <br />EQUIPMENT <br />ELEVATION <br />DEGREES FAHRENHEIT <br />FOOT, FEET <br />FIRE ALARM <br />FT <br />° F <br />EXH <br />EXIST, (E) <br />FACP <br />FA <br />EQUIP <br />EFF <br />EL <br />ESP <br />EWB <br />ELEC <br />FIRE ALARM CONTROL PANEL <br />TEMPERATURE <br />SFD (COMBINATION) SMOKE-FIRE DAMPER <br />OVERFLOWOF <br />M/U MAKE-UP <br />FD FIRE DAMPER <br />D/P DIFFERENTIAL PRESSURE <br />B BOILER <br />ABBREVIATIONS <br />V <br />W <br />X <br />G <br />H R <br />S <br />I <br />T <br />K <br />L <br />B <br />C <br />Q <br />U <br />M <br />N <br />O <br />E <br />F <br />D <br />A <br />P <br />COMBINATION FIRE/SMOKE DAMPERCFSD <br />FIRE SMOKE DAMPERFSD <br />NK NECK SIZE <br />TRANSFERTR <br />EXHAUST AIR GRILLEEAG <br />EXHAUST AIR REGISTEREAR <br />RETURN AIR GRILLERAG <br />RETURN AIR REGISTERRAR <br />SUPPLY AIR REGISTERSAR <br />DOOR LOUVERDL <br />DOOR UNDERCUTUC <br />SHEET INDEX <br />SHT.NO.DESCRIPTION <br />M1.0 MECHANICAL NOTES AND LEGENDS <br />AIR CONDITIONING <br />AND ADMINISTRATION <br />CODE AND STANDARDS <br />SD <br />H <br />C <br />1 <br />M-100 <br />X <br />X <br />1/M-100 <br />DETAIL DESIGNATION <br />DRAWING WHERE DETAIL <br />IS SHOWN <br />DIFFUSER, GRILLE OR <br />REGISTER MARK <br />(SEE SCHEDULE) <br />EQUIPMENT <br />MARK (SEE <br />SCHEDULE) <br />DETAIL <br />DESIGNATION <br />LOCATOR/DESCRIPTOR <br />DRAWING WHERE <br />DETAIL IS SHOWN <br />OR WHERE DETAIL <br />IS REFERENCED <br />FROM <br />SECTION CUT <br />LOCATOR/DESCRIPTOR <br />DRAWING WHERE <br />SECTION IS <br />SHOWN OR WHERE <br />DETAIL IS <br />REFERENCED <br />FROM <br />MATCH LINE <br />EQUIPMENT TAG FOR <br />VRF SYSTEM FAN <br />COILS <br />ASSOCIATED BRANCH <br />CONTROL CIRCUIT <br />ASSOCIATED VRF <br />CONDENSING UNIT <br />12"Ø <br />20x12 <br />DN <br />UP <br />S (ZONE) <br />T (ZONE) <br />MANUAL VOLUME DAMPER <br />COMBINATION SMOKE/FIRE DAMPER <br />SUPPLY AIR DIFFUSER - ARROWS INDICATE <br />PATTERN. NO PATTERN SHOWN EQUALS 4-WAY <br />RETURN AIR GRILLE <br />EXHAUST GRILLE <br />(L) INDICATE ACOUSTICAL LINER(SINGLE LINE) <br />RELIEF OR EXHAUST AIR DUCT <br />RETURN AIR DUCT <br />SUPPLY OR OUTSIDE AIR DUCT <br />SUPPLY OR OUTSIDE AIR DUCT DOWN <br />RETURN AIR DUCT DOWN <br />SUPPLY OR OUTSIDE AIR DUCT UP <br />RETURN AIR DUCT UP <br />ROUND DUCT BRANCH TAKE-OFF FROM <br />RECTANGULAR MAIN WITH CONICAL TAP. <br />DUCTWORK SIZE TRANSITION <br />RECTANGULAR DUCTWORK. SIZE INDICATED IN INCHES, <br />FIRST NUMBER IS TOP OR BOTTOM SHOWN (SINGLE LINE) <br />ROUND DUCTWORK (SINGLE LINE) <br />RELIEF OR EXHAUST AIR DUCT DOWN <br />IN-LINE 90 DEGREE DROP (RISE) IN DUCT <br />TURNING VANES <br />INCLINED DROP IN DUCT <br />INCLINED RISE IN DUCT <br />NEW DUCTWORK (SINGLE LINE) <br />EXISTING DUCTWORK (SINGLE LINE) <br />RELIEF OR EXHAUST AIR DUCT UP <br />RETURN AIR BOOT <br />MOTORIZED DAMPER <br />FLEXIBLE DUCT (SINGLE PIECE, 7 FEET MAX.) <br />TEMPERATURE SENSOR (MOUNT 46" AFF) <br />BACKDRAFT DAMPER <br />ROOM THERMOSTAT (MOUNT 46" AFF) <br />HVAC SYMBOLS <br />HUMIDISTAT (MOUNT 96" AFF) <br />DUCT SMOKE DETECTOR <br />POINT OF NEW CONNECTION <br />DEMOLITION NOTE <br />CO2 SENSOR (MOUNT 96'' AFF) <br />KEYED NOTE <br />POINT OF DISCONNECTION <br />FCV-X <br />VCU BC <br />BAROMETRIC RELIEF DAMPER <br />AHU <br />1 <br />1 <br />M-10 <br />X <br />(L) <br />3. <br />2. <br />1. <br />4. <br />SEISMIC RESTRAINT NOTES <br />SCOPE <br />SEISMIC RESTRAINT GUIDELINES <br />PIPING <br />·SEISMICALLY BRACE INDIVIDUALLY SUPPORTED PIPING <br />GREATER THAN 3" IN DIAMETER. <br />·SEISMICALLY BRACE TRAPEZE ASSEMBLIES IF PIPING IS <br />GREATER THAN 10 LB/FT. <br />DUCTWORK <br />·SEISMICALLY BRACE DUCTWORK 6' SQUARE FEET OR GREATER <br />OR 17 LB/FT OR MORE. <br />EQUIPMENT <br />· <br />·SEISMICALLY BRACE EQUIPMENT HUNG FROM THE STRUCTURE <br />2O LBS OR MORE. <br />FIRE LIFE SAFETY NOTES <br />THE ELECTRICAL CONTRACTOR SHALL INTERCONNECT ALL <br />FANS AND AC UNITS WITH THE BUILDING LIFE SAFETY <br />SYSTEM FOR UNIT SHUT DOWN UPON A SIGNAL FROM THE <br />LIFE SAFETY SYSTEM. <br />WHERE DUCT MOUNTED SMOKE DETECTORS FOR FANS AND <br />AC UNITS ARE REQUIRED, THE HVAC CONTRACTOR SHALL <br />FURNISH AND INSTALL THE SMOKE DETECTORS, THE <br />ELECTRICAL CONTRACTOR PROVIDE ALL WIRING AND <br />CONDUIT TO SIGNAL THE LIFE SAFETY SYSTEM. THE LIFE <br />SAFETY SYSTEM SHALL SHUT DOWN THE EXHAUST FANS OR <br />AC UNITS AS DESCRIBED IN NOTE #1. <br />ALL SMOKE DETECTORS SHALL BE INSTALLED PER <br />MANUFACTURER'S RECOMMENDATION AND SHALL BE <br />COMPATIBLE WITH WITH THE BASE BUILDING STANDARDS. <br />EACH SINGLE SYSTEM PROVIDING HEATING OR COOLING AIR IN <br />EXCESS OF 2000 CFM OR 54,000 BTU SHALL BE EQUIPPED WITH <br />AN AUTOMATIC SHUT-OFF. THE SMOKE DETECTOR SHALL BE <br />INSTALLED IN THE MAIN SUPPLY AIR DUCT DOWNSTREAM OF <br />THE FILTERS OR THEY MAY BE INSTALLED IN EACH ROOM OR <br />SPACE SERVED BY THE SUPPLY AIR DUCT. DETECTORS SHALL <br />ALSO BE INSTALLED IN THE MAIN RETURN DUCT (IF REQ'D. BY <br />THE LOCAL CODE) AHEAD OF OSA INTAKE. SEE CODE FOR <br />EXEMPTIONS AND LOCAL AUTHORITY FOR CODE <br />INTERPRETATION, OR AS INDICATED ON PLAN. <br />SEISMIC RESTRAINT SYSTEMS FOR PIPING, DUCTWORK AND <br />EQUIPMENT IS A DELEGATED DESIGN. THE GENERAL REQUIREMENTS <br />PRESENTED BELOW ARE NOT ALL-INCLUSIVE AND REPRESENT <br />SIMPLIFIED REQUIREMENTS BASED ON THE CRITERIA LISTED BELOW. <br />IT IS THE CONTRACTOR'S RESPONSIBILITY TO DESIGN A SYSTEM <br />THAT IS IN FULL COMPLIANCE WITH THE LISTED CRITERIA . <br />EXCEPTION: DUCTWORK SUSPENDED 12” OR LESS FROM <br />THE SUPPORTING STRUCTURE <br />SEISMICALLY BRACE EQUIPMENT 400 LBS OR MORE WITH A <br />CENTER OF MASS AT 4FT OR LESS TO THE FINISHED FLOOR <br />EXCEPTION: HANGERS IN THE PIPING RUN ARE 12” OR <br />LESS FROM TOP OF THE TRAPEZE BAR TO THE <br />SUPPORTING STRUCTURE. <br />EXCEPTION: PIPING SUPPORTED BY ROD WITHIN 12” OF <br />THE SUPPORTING STRUCTURE. <br />1.MECHANICAL CONTRACTOR SHALL GUARANTEE THE ENTIRE <br />HEATING, VENTILATING AND AIR CONDITIONING SYSTEM FOR A <br />PERIOD OF ONE (1) YEAR FROM THE DATE OF PRACTICAL <br />COMPLETION. IF, DURING THIS PERIOD, ANY MATERIALS OR <br />APPARATUS PROVE DEFECTIVE OR ANY PART OF THE SYSTEM <br />FAILS TO FUNCTION PROPERLY, CONTRACTOR SHALL PROVIDE <br />PARTS AND LABOR TO RECTIFY PROBLEMS WITHOUT EXPENSE <br />TO OWNER. <br />2.ALL A/C COMPRESSORS SHALL HAVE FULL 5 YEAR NON-PRO <br />RATED WARRANTY FOR REPLACEMENT WITH NEW <br />COMPRESSORS. ALL A/C UNITS HEAT EXCHANGERS SHALL BE <br />WARRANTED AGAINST DEFECTS FOR A TEN (10) YEAR PERIOD. <br />PROVIDE ANTI-SHORT CYCLING FEATURE FOR COMPRESSORS. <br />3.FURNISH OWNER WITH ALL MANUFACTURERS WRITTEN <br />GUARANTEES OF MATERIAL AND EQUIPMENT AS CONDITION OF <br />FINAL PAYMENT. <br />WARRANTY INFORMATION <br />1.METAL DUCT: SHEET METAL DUCTWORK CONSTRUCTION TO <br />COMPLY WITH THE LOS ANGELES CITY MECHANICAL CODE AND <br />SMACNA GUIDE LINE, WHICHEVER PROVIDES THE STRONGER <br />DUCT CONSTRUCTION. <br />2.FLEXIBLE DUCT: FLEXIBLE ROUND DUCT SHALL NOT BE LONGER <br />THAN 5'-0" LONG IN FULLY EXTENDED INSTALLED CONDITION <br />WITH MINIMUM NUMBER OF BENDS. (NOTE: NO ALUMINUM FLEX <br />DUCT IS TO BE USED IN THIS PROJECT.) <br />3.DUCT ACCESSORIES: PROVIDE APPROVED DUCT TAPE OR <br />CLAMP FOR FLEX TO DUCT CONNECTION. ALL SHEET METAL <br />SHALL HAVE A MIN. OF 2" COLLAR ON 4" SLEEVES USED TO JOIN <br />THE FLEXIBLE DUCT ATTACHMENT. ALL DUCT JOINTS SHALL BE <br />SEALED WITH AN APPROVED TYPE MASTIC. <br />4.DUCT INSULATION: DUCT INSULATION TO BE FIBERGLASS 3/4 <br />P.C.F. DENSITY AND R8 OUTDOORS AND SPACE DIRECTLY UNDER <br />A ROOF WITH FIXED VENTS AND R4.2 IN CONDITIONED OR <br />INDIRECTLY CONDITIONED SPACE. <br />5.HANGERS: DUCTWORK LESS THAN 48" X 24" SHALL BE <br />SUPPORTED WITH A MINIMUM OF 2" X 1-1/2" INCH WIDE CHANNELS <br />AND 1" HANGER STRAP AS REQUIRED BY UMC TABLE A6-5E AND F. <br />FOR DETAIL SPECIFICATION OF MATERIAL, PRODUCT AND EXECUTION <br />REFER TO BOOKLET SPECIFICATION. <br />SPECIFICATION <br />MECHANICAL NOTES <br />THE HVAC SYSTEM WILL BE DESIGNED TO CONFORM, AT A MINIMUM, TO <br />THE FOLLOWING CODES AND STANDARDS: <br />·BUILDING STANDARDS ADMINISTRATIVE CODE (2022) <br />·ASHRAE FUNDAMENTALS HANDBOOK (2013) <br />·ASHRAE HVAC APPLICATIONS HANDBOOK (2011) <br />·ASHRAE HVAC SYSTEMS AND EQUIPMENT HANDBOOK (2012) <br />·ASHRAE 62.1 - VENTILATION FOR ACCEPTABLE INDOOR AIR <br />QUALITY (2019) <br />·ASHRAE 62.2 - VENTILATION AND ACCEPTABLE INDOOR AIR <br />QUALITY IN LOW-RISE RESIDENTIAL BUILDINGS (2019) <br />·ASHRAE 90.1 - ENERGY STANDARD FOR BUILDINGS EXCEPT <br />LOW-RISE RESIDENTIAL BUILDINGS (2010) <br />·ASHRAE GUIDELINE 1 - THE HVAC COMMISSIONING PROCESS <br />(2007) <br />·CALIFORNIA BUILDING CODE (2022) <br />·CALIFORNIA MECHANICAL CODE (2022) <br />·CALIFORNIA PLUMBING CODE (2022) <br />·CALIFORNIA ENERGY CODE (2022) <br />·CALIFORNIA GREEN BUILDING STANDARD CODE (2022) <br />·CALIFORNIA ELECTRICAL CODE (2022) <br />·CALIFORNIA RESIDENTIAL CODE (2022) <br />·CALIFORNIA FIRE CODE (2022) <br />·UNIFORM PLUMBING CODE (2022) <br />·NFPA 90A - INSTALLATION OF AIR CONDITIONING AND <br />VENTILATING SYSTEMS (2015) <br />·SMACNA HVAC DUCT CONSTRUCTION STANDARDS: METAL AND <br />FLEXIBLE <br />·SMACNA HVAC SYSTEMS DUCT DESIGN <br />·SMACNA SEISMIC RESTRAINT MANUAL FOR MECHANICAL <br />SYSTEMS <br />MUA MAKE-UP AIR <br />MECHANICAL FLOOR PLAN <br />M1.1 <br />M2.0 <br />MECHANICAL EQUIPMENT SCHEDULESM1.2 <br />MECHANICAL DETAILSM4.0 <br />SUPPLY WALL REGISTERSWR <br />MECHANICAL ROOF PLANM3.0 <br />CAPTIVEAIRE DRAWINGSM5.0 <br />MECHANICAL DETAILSM4.1 <br />CAPTIVEAIRE DRAWINGSM5.1 <br />CAPTIVEAIRE DRAWINGSM5.2 <br />CAPTIVEAIRE DRAWINGSM5.3 <br />ENERGY COMPLIANCEM1.4 <br />ENERGY COMPLIANCEM1.5 <br />TAG TRANSFER AIR GRILLE <br />MECHANICAL EQUIPMENT SCHEDULESM1.3 <br />ENERGY COMPLIANCEM1.6 <br />INSTALL NEW AIR HANDLING UNIT, CONDENSING UNITS, PACKAGED <br />AC UNITS, FANS, DUCTWORK, AND TYPE I HOODS. <br />SCOPE OF WORK <br />HOLD- 420 W 17th <br />St3/7/2025