My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1105 S Karen Ave - Plan
PBA
>
Building
>
ProjectDox
>
K
>
Karen Ave
>
1105 S Karen Ave
>
1105 S Karen Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:37:06 AM
Creation date
6/5/2025 7:36:37 AM
Metadata
Fields
Template:
Plan
Permit Number
20183391
101120022
Full Address
1105 S Karen Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />SIGNATURE WITH SEAL <br />PROJECT NAME & <br />ADDRESS <br />E2.0 <br />DATE: 1/17/2024 <br />11 <br />0 <br />5 <br /> S <br />K <br />A <br />R <br />E <br />N <br /> <br />A <br />V <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br />, <br />92 <br />7 <br />0 <br />4 <br />JO <br />R <br />G <br />E <br /> <br />M <br />A <br />G <br />A <br />L <br />L <br />O <br />N <br /> R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />DESCRIPTION DATE REV <br />REVISIONS <br />INITIAL DESIGN 1/17/2024 00 <br />LEVION CONSTRUCTION LLC <br />2020 IOWA AVE SUITE 103, <br />RIVERSIDE, CA 92507 <br />CONTRACTOR LIC#: #1096696 <br />PHONE #: 951-554-2201 <br />GENERAL B <br />ZACHARY WINGER <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />SIGNATURE WITH SEAL <br />PROJECT NAME & <br />ADDRESS <br />E2.0 <br />DATE: 1/17/2024 <br />11 <br />0 <br />5 <br /> S <br />K <br />A <br />R <br />E <br />N <br /> <br />A <br />V <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br />, <br />92 <br />7 <br />0 <br />4 <br />JO <br />R <br />G <br />E <br /> <br />M <br />A <br />G <br />A <br />L <br />L <br />O <br />N <br /> R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />DESCRIPTION DATE REV <br />REVISIONS <br />INITIAL DESIGN 1/17/2024 00 <br />LEVION CONSTRUCTION LLC <br />2020 IOWA AVE SUITE 103, <br />RIVERSIDE, CA 92507 <br />CONTRACTOR LIC#: #1096696 <br />PHONE #: 951-554-2201 <br />GENERAL B <br />ZACHARY WINGER <br />ELECTRICAL <br />LINE DIAGRAM <br />NOTE :- MAIN PANEL SCHEDULE AND LOAD <br />CALCULATION ON PREVIOUS PAGE <br />AC OUTPUT CURRENT <br />NOMINAL AC VOLTAGE 240V <br />13.31A <br />THIS PANEL IS FED BY MULTIPLE SOURCES <br />(UTILITY AND SOLAR) <br />ENPHASE Q CABLE TO BE ATTACHED TO <br />RAIL MIN. 3-1/2" ABOVE ROOF SURFACE <br />SYSTEM NOTES: <br />1.ENPHASE IQ7 / IQ8 SERIES MICROINVERTERS DO NOT REQUIRE GROUNDING <br />ELECTRODE CONDUCTORS OR EQUIPMENT GROUNDING CONDUCTORS. THE <br />MICROINVERTERS ITSELF HAS CLASS II DOUBLE-INSULATED RATING, WHICH <br />INCLUDES GROUND FAULT PROTECTION. <br />2.ENPHASE Q CABLE HAS NO NEUTRAL WIRE - (2 WIRE DOUBLE INSULATED CABLING) <br />3.MODULES ARE BONDED TO RAIL USING ILSCO/SWH INTEGRATED GROUNDING. <br />4.RAILS ARE BONDED WITH UL 2703 RATED LAY-IN LUGS <br />5.SYSTEM IS UNGROUNDED <br />6.BARE COPPER IS TRANSITIONED TO THHN/THWN-2 VIA IRREVERSIBLE CRIMP; GEC <br />TO BE CONTINUOUS PER CEC 250.64(C) <br />7.SUB-BRANCHES ARE CENTER-FED AT JBOX TO MAKE ONE TOTAL BRANCH CIRCUIT. <br />8.ENPHASE IQ ENVOY INSIDE IQ COMBINER REQUIRES A NEUTRAL TO BE LANDED AT <br />THE NEUTRAL BUSS AT MAIN PANEL PER ENPHASE INSTALLATION INSTRUCTIONS. <br />9.ENPHASE MICROINVERTERS ARE ALL RAPID SHUTDOWN READY <br />10.JUNCTION BOX TO BE READILY ACCESSIBLE <br />AMBIENT TEMP (HIGH TEMP 2%) <br />RECORD LOW TEMP <br />CONDUIT HEIGHT <br />ROOF TOP TEMP <br />CONDUCTOR TEMPERATURE RATE <br />2° <br />35° <br />7/8" <br />57° <br />90° <br />Rooftop conductor ampacities designed <br />in compliance with art. 690.8, Tables <br />310.15(B)(2)(a), 310.15(B)(3)(a), <br />310.15(B)(3)(c), 310.15(B)(16), Chapter <br />9 Table 4, 5, & 9. Location specific <br />temperature obtained from ASHRAE <br />2017 data tables <br />MICRO-INVERTER SPECIFICATIONS <br />MANUFACTURER <br />MAX. POWER AT 40 C <br />60 VOLTS <br />NOMINAL AC VOLTAGE <br />290 WATTS <br />MAX. AC CURRENT <br />240 VOLTS <br />MAX. OCPD RATING <br />MAX. PANELS/CIRCUIT <br />SHORT CIRCUIT CURRENT <br />1.21 AMPS <br />20 AMPS <br />MAX. DC VOLT RATING <br />13 <br />15 AMPS <br />ENPHASE ENERGY IQ8 PLUS-72-2-US <br />NOTE- PV BREAKER IS INSTALLED AT OPPOSITE <br />END OF BUSBAR FROM THE MAIN BREAKER <br />WIRE FROM - - <br />ARRAY TO JUNCTION BOX <br />CONDUIT <br />PV WIRE <br />COMBINER PANEL TO ACD TO IQ CONTROLLER <br />2 <br />2 <br />3 <br />#12 <br />WIRE TYPE <br />25A <br />35A <br />11 x <br />NOC: <br />1.21 <br />125%: <br />x 1.25 = 16.64A <br />#6 <br />#8 <br />#8 <br />EGC <br />THWN-2 <br />THWN-2 <br />WIRE <br />TAG # <br />WIRE <br />QTY <br />WIRE <br />GAUGE: <br />TEMP <br />RATING: <br />WIRE <br />AMP <br />TEMP <br />DE-RATE: <br />CONDUIT <br />FILL: <br />WIRE <br />OCP: <br />TERMINAL <br />75°C RATING: <br />INVERTER <br />QTY: <br />STRING <br />AMPS <br />GRND <br />SIZE <br />GRND WIRE <br />TYPE <br />1 <br />3/4" EMT <br />3/4" EMT <br />#102 <br />3 <br />ENPHASE TRUNK CABLE <br />INCLUDES #12 GROUND <br />JUNCTION BOX TO COMBINER PANEL <br />IQ CONTROLLER TO ENCHARGE 2 <br />#6 THWN-2311x1.21 x 1.25 = 16.64AIQ CONTROLLER TO MSP4 <br />90°30A 0.96 0.80 20A MAXTRUNK CABLE <br />90°40A 1.00 30A MAX0.96THWN-23/4" EMT <br />#1 11 x 1.21 1.25 =16.64 <br />#2 0 x 1.21 1.25 =0.00 <br />#3 0 x 1.21 1.25 =0.00 <br />#4 0 x 1.21 1.25 =0.00 <br />NOTE - <br />·JBOX HAVE A 3/16” (5MM) DRAINAGE HOLE AT THE LOWEST POINT OF THE ENCLOSURE PER UL50 9.7.2 IN ACCORDANCE WITH 7.3.3.3 AND CEC 314.15 <br />·DISCONNECT IS ON SAME SIDE OF THE FENCE AS SOLAR PV EQUIPMENT AS PER THE CEC 690.15 <br />·NEW ELECTRICAL SHALL BE LOCATED AT LEAST THREE (3) FEET FROM GAS METER OR GAS SHUT-OFF VALVES. CPC1208.7.1; CEC 110.26 <br />·THE NEW PV SYSTEM HAS EQUAL OR GREATER AIC RATING TO THE EXISTING ELECTRICAL SYSTEM. CEC 690.13(E) <br />·GROUNDED DC PV ARRAYS SHALL PROVIDED WITH DC GROUND-FAULT PROTECTION MEETING THE REQUIREMENTS <br />OF 690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDS <br />·ESS EQUIPMENT SHALL BE LOCATED 3' FROM ALL WINDOWS AND DOORS DIECTLY ENTERING THE HOME <br />11 x 1.21 x 1.25 = 16.64A <br />BATTERY AC OUTPUT CURRENT <br />1 x 16 x 1.25 = 20.00A <br />PV AC OUTPUT CURRENT <br />PV MODULE RATING @ STC <br />MANUFACTURER <br />MAX. POWER-POINT CURRENT (IMP) <br />MAX. POWER-POINT VOLTAGE (VMP) <br />OPEN-CIRCUIT VOLTAGE (VOC) <br />SHORT-CIRCUIT CURRENT (ISC) <br />NOM. MAX. POWER AT STC (PMAX) <br />MAX. SYSTEM VOLTAGE <br />VOC TEMPERATURE COEFFICIENT <br />CANADIAN SOLAR <br />CS6R-400MS-HL [BLK] <br />12.99 AMPS <br />30.8 VOLTS <br />36.8 VOLTS <br />13.85 AMPS <br />400 WATT <br />1000V <br />-0.26° %/°C <br />35A#10 90°40A 1.00 30A MAX0.96THWN-2 <br />1-1/4" EMT <br />G <br />N <br />(N) 200A <br />M <br />(E) LOADS <br />3 <br />G <br />L1L1 <br />L2L2 <br />11 MICRO-INVERTERS IN BRANCH CIRCUIT #1 <br />TERMINATOR CAP ON LAST CABLE <br />CONNECTOR AC TRUNK CABLE (TYP) <br />L1 <br />L2 <br />N <br />G <br />NG <br />M*IQ-Envoy <br />2 <br />(E) LOADS <br />I/0-1 Gen-I/0 <br />GROUNDING <br />TERMINAL GROUNDING <br />ELECTRODE <br />20A <br />NEUTRAL <br />FROM <br />20A <br />COMBINER <br />PANEL <br />CONTROL PCBA <br />MAINS <br />RELAY <br />L2 L1 <br />(E) LOADS <br />(N) IQ SYSTEM CONTROLLER 3 <br />SC200D111C240US01 <br />NEMA 3R, 160A RATED, 240V <br />G <br />N <br />LESS THAN 5' <br />2 <br />NEUTRAL FORMING <br /> TRANSFORMER(40A) <br />12 AWG <br />I/0-2 <br />40A <br />RSD <br />ENPHASE ENCHARGE BATTERY BREAKER(20A) <br />AC COMBINER BREAKER(20A) <br />(N) 100A <br />BOND EGC TO FACILITY GEC <br />IRREVERSIBLE CRIMP OR <br />EQUIVALENT <br />EXISTING GROUNDING ELECTRODE SYSTEM <br />AT LEAST TWO GROUNDING RODS WILL BE <br />PROVIDED OR ONE GROUNDING ROD AND <br /> A UFER GROUNDGROUNDING ELECTRODE <br /> CONDUCTOR SHALL BE SIZED PER CEC 250.66. <br />20A <br />1 <br />(N)125A <br />SUB-PANEL <br />#2 AWG <br />THWN-2 <br />#8 AWG <br />GROUND <br />1-1/4" EMT <br />(N) BLADE TYPE <br />NON-FUSIBLE AC DISCONNECT <br />NEMA 3R 30A-2P 120/240VAC <br />(VISIBLE, LOCKABLE, LABELED) <br />RSD <br />(RAPID SHUTDOWN SWITCH) <br />NOTE- RSD WITHIN 3' OF <br />MAIN SERVICE PANEL <br />THE WIRE SIZE AND TYPE OF THE SERVICE FEEDING <br />CONDUCTOR FOR THE MAIN SERVICE PANEL SHALL BE <br />DETERMINED BY THE UTILITY PROVIDER <br />ALL SERVICES SUPPLYING DWELLING UNITS SHALL BE <br />PROVIDED WITH A SURGE-PROTECTIVE DEVICE (SPD) <br />PER SECTION 230.67 OF THE 2022 CALIFORNIA <br />ELECTRICAL CODE TYPE 1 SPD <br />3 4 <br />#2 115A90°THWN-2 115A 0.94A 1.00A 108.10A <br />MAX <br />AUTO TRANSFORMER (NFT) <br />POINT OF INTERCONNECT, BACKFEED IN MSP, <br />NEW 240V/225A BUSBAR RATING, <br />MAIN SERVICE PANEL, SINGLE PHASE, <br />WITH A 200A MAIN BREAKER <br />UTILITY COMPANY - SCE <br />(11) CANADIAN SOLAR CS6R-400MS-HL [BLK] <br />MODULES (400W) AND <br />(11) (ENPHASE ENERGY IQ8PLUS-72-2-US [240V]) <br />MICROINVERTERS 240VAC, 1.21A MAX <br />CEC WEIGHTED EFFICIENCY 97.0% <br />NEMA 4R, UL LISTED, INTERNAL GFDI (N) JUNCTION BOX <br />600 V, NEMA 4 UL LISTED <br />J-BOX TO BE READILY <br />ACCESSIBLE <br />METER # 222013-630173 <br />PRODUCER STORAGE DEVICE(S) WILL NOT CAUSE THE HOST LOAD TO EXCEED ITS <br />NORMAL PEAK DEMAND. NORMAL PEAK DEMAND IS DEFINED AS THE HIGHEST AMOUNT <br />OF POWER REQUIRED FROM THE DISTRIBUTION SYSTEM BY PRODUCERS COMPLETE <br />FACILITIES WITHOUT THE INFLUENCE OR USE OF THE ENERGY STORAGE DEVICE(S). <br />(N)125A ENPHASE IQ <br />ENVOY COMBINER 5 <br />ENPHASE X-IQ-AM1-240-5 <br />15A <br />1 X (N) ENPHASE IQBATTERY-5P-1P-NA PARTIAL <br />BACKUP, NEMA 3R 240 VAC, 5 kWH, 3.84 kVA <br />NOTE - 1 ENPHASE IQBATTERY-5P-1P-NA PARTIAL BACKUP <br />ENERGY STORAGE HAS INTEGRATED 6 IQ8D-BAT <br />MICROINVERTERS (MEETS CA RULE 21 (UL 1741-SB)) <br />IF EXISTING UFER NOT FOUND, REQ'D <br />5/8" DIA. GROUND ROD,8'-0"MIN <br />EMBEDMENT AND REQ'D 6'-0" APART <br />BTWN TWO GROUNDINGS. <br />BACKUP SUB PANEL LOAD SCHEDULE <br />AND LOAD CALCULATION <br />2,3 <br />1105 S Karen Ave <br />8/22/2024
The URL can be used to link to this page
Your browser does not support the video tag.