Laserfiche WebLink
SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />SIGNATURE WITH SEAL <br />PROJECT NAME & <br />ADDRESS <br />P1.0 <br />DATE: 1/17/2024 <br />11 <br />0 <br />5 <br /> S <br />K <br />A <br />R <br />E <br />N <br /> <br />A <br />V <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br />, <br />92 <br />7 <br />0 <br />4 <br />JO <br />R <br />G <br />E <br /> <br />M <br />A <br />G <br />A <br />L <br />L <br />O <br />N <br /> R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />DESCRIPTION DATE REV <br />REVISIONS <br />INITIAL DESIGN 1/17/2024 00 <br />LEVION CONSTRUCTION LLC <br />2020 IOWA AVE SUITE 103, <br />RIVERSIDE, CA 92507 <br />CONTRACTOR LIC#: #1096696 <br />PHONE #: 951-554-2201 <br />GENERAL B <br />ZACHARY WINGER <br />CAUTION <br />WARNING <br />LABELS <br />SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN ARRAY <br />PROJECT ADDRESS <br />1105 S KAREN AVE, SANTA ANA, CA, 92704 <br />N <br />NOTE:-PLAQUES SHALL BE METAL OR PLASTIC, WITH ENGRAVED OR <br />MACHINE PRINTED LETTERS, OR ELECTRO-PHOTO PLATING, IN A <br />CONTRASTING COLOR TO THE PLAQUE-PLACARD IS TWO COLOR/RED <br />FACE-WHITE CORE ENGRAVED PLASTIC. PLAQUE SHALL BE ATTACHED TO <br />THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.PLAQUE AT MSP <br />IN JURISDICTION WHERE REQUIRED <br />1 <br /> S KAREN AVE <br />CAUTION: MULTIPLE SOURCES OF POWER <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN <br />1.MAIN ELECTRIC <br />SERVICE DISCONNECT <br />2.COMBINER <br />3.AC DISCONNECT <br />4.BATTERY <br />5.IQ CONTROLLER <br />6.RAPID SHUTDOWN <br />SWITCH <br />7.SUB PANEL <br />4 <br />LABEL SHOULD BE <br />LOCATED AT MEP <br />AT BATTERY SYSTEM <br />DISCONNECT <br />!! <br />706.15 <br />DISCONNECTING <br />MEANS <br />690.13 PHOTOVOLTAIC <br />SYSTEM DISCONNECTING <br />MEANS. <br />BATTERY STORAGE <br />COMBINER BOX <br />SUB PANEL <br />!!690.13 PHOTOVOLTAIC <br />SYSTEM DISCONNECTING <br />MEANS. <br />! <br />690.53 DC PV <br />CIRCUITS <br />AC DISCONNECT <br />!!690.13 PHOTOVOLTAIC <br />SYSTEM DISCONNECTING <br />MEANS. <br />! <br />705.20.8 PLACED AT ALL <br />PV DISCONNECTS, IF THE <br />DISCONNECT ONLY PARTIAL <br />SHUTS DOWN THE SYSTEM IT <br />WILL NEED TO BE LABELED <br />ACCORDINGLY <br />690.56.C.2 <br />ALL RAPID SHUTDOWN <br />WITCHES THE LABEL SHALL <br />BE REFLECTIVE, <br />MAIN SERVICE PANEL <br />690.54 INTERACTIVE <br />SYSTEM POINT OF <br />INTERCONNECTION <br />705.20.8 PLACED AT ALL <br />PV DISCONNECTS, IF THE <br />DISCONNECT ONLY PARTIAL <br />SHUTS DOWN THE SYSTEM IT <br />WILL NEED TO BE LABELED <br />ACCORDINGLY <br />!705.12.B.3.2 INTERIOR OF ALL <br />PANLEBOARDS WITH PV <br />BREAKERS <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />DC/AC CONDUIT LABEL. MUST <br />BE A REFLECTIVE STICKER. <br />LABEL SHOULD BE <br />LOCATED AT MEP <br />LABEL SHOULD BE <br />LOCATED AT COMBINER BOX <br />SIGNAGE OR LABELING SPECIFICATIONS PER <br />CEC690,CEC705,: REFLECTIVE,RED BACKGROUND <br />WITH WHITE LETTERING,3/8" LETTER HEIGHT,ALL <br />CAPITAL LETTERS, ARIAL OR SIMILAR <br />FONT,WEATHER RESISTANT MATERIAL <br />BATTERY SYSTEM RATED AC OUTPUT CURRENT - 16.00A <br />PV SYSTEM RATED AC OUTPUT CURRENT - 13.31A <br />BATTERY AND PV SYSTEM RATED AC OUTPUT VOLTAGE - 240V <br />PV SYSTEM POWER PHASE - SINGLE <br />EMERGENCY DISCONNECT <br />FOR BATTERY SYSTEM <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />ENERGY STORAGE <br />SYSTEM DISCONNECT <br />NOMINAL ESS AC VOLTAGE <br />MAXIMUM ESS DC VOLTAGE <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />PV SYSTEM <br />DISCONNECT <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />DO NOT ADD LOADS <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />PV SYSTEM <br />DISCONNECT <br />MAIN PV <br /> DISCONNECT <br />RAPID <br /> SHUTDOWN SWITCH <br /> FOR SOLAR PV SYSTEM <br />MAXIMUM AC <br />OPERATING CURRENT <br />MAXIMUM AC <br />OPERATING VOLTAGE <br />PV SYSTEM <br />DISCONNECT <br />MAIN PV <br /> DISCONNECT <br />WARNING <br />POWER SOURCE OUTPUT CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />! CAUTION - TRI POWER SOURCE ! <br />FIRST SOURCE IS UTILITY ELECTRICAL GRID <br />SECOND SOURCE IS AC BATTERY <br />THIRD SOURCE IS PV <br />29.31A <br />240V <br />240V <br />76.8V <br />THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES <br />TOTAL RATING OF ALL OVERCURRENT <br />DEVICES EXCLUDING MAIN POWER SUPPLY <br />SHALL NOT EXCEED AMPACITY OF BUSBAR <br />WARNING!705.12.B.3.3 <br />INTERIOR OF ALL <br />PANLEBOARDS <br />WITH PV <br />BREAKERS <br />SOLAR ELECTRIC <br />PV PANELS <br />TURN RAPID <br />SHUTDOWN SWITCH <br />TO THE "OFF" <br />POSITION TO SHUT <br />DOWN PV SYSTEM <br />AND REDUCE SHOCK <br />HAZARD IN THE ARRAY <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />690.56.C <br />IDENTIFICATION OF <br />POWER SOURCES <br />! <br />32 <br />6 <br />7 <br />5 <br />1105 S Karen Ave <br />8/22/2024