My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2621 S Birch St - 101119515 & 20182981 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Birch St
>
2621 S Birch St
>
2621 S Birch St - 101119515 & 20182981 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 9:46:26 AM
Creation date
6/5/2025 7:36:43 AM
Metadata
Fields
Template:
Plan
Permit Number
20182981
101119515
Full Address
2621 S Birch St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
RADIATOR/EXHAUST/ <br />FUEL END <br />DISCHARGE <br />BA <br />T <br />T <br />E <br />R <br />Y <br /> <br />B <br />O <br />X <br />PO <br />W <br />E <br />R <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br /> <br />& <br />CO <br />N <br />T <br />R <br />O <br />L <br />S <br />BO <br />L <br />T <br /> <br />O <br />N <br /> <br />P <br />A <br />N <br />E <br />L <br />S <br />5' V <br />E <br />N <br />T <br />RAD <br />I <br />U <br />S <br />10 <br />' <br />- <br />0 <br />" <br />10 <br />' <br />- <br />0 <br />" <br />4'-0" <br />4'-0" <br />5' V <br />E <br />N <br />T <br />RAD <br />I <br />U <br />S <br />OVERALL <br />SITE PLAN <br />PO BOX 2621, BOISE, ID 83701 <br />530.539.4787 <br />CONTACT@GEOSTRUCTURAL.COM <br />WWW.GEOSTRUCTURAL.COM <br />0 04/01/24 ISSUED FOR CONSTRUCTION BM <br />SHEET TITLE: <br />SHEET NUMBER: <br />A-1 <br />REV DATE DESCRIPTION INT <br />REVISIONS <br />SITE INFORMATION: <br />2621 SOUTH BIRCH STREET <br />SANTA ANA, CA 92707 <br />GENERATOR INSTALLATION <br />PROJECT <br />MAIN - DYER <br />10086996 <br />CHECKED BY:JAD <br />THE INFORMATION CONTAINED IN THIS SET OF <br />DOCUMENTS IS PROPRIETARY BY NATURE. ANY <br />USE OR DISCLOSURE OTHER THAN THAT WHICH <br />RELATES TO THE CLIENT NAMES IS STRICTLY <br />PROHIBITED. <br />at t & <br />GENERAL DYNAMICS <br />Information Technology <br />09/30/25 <br />JURISDICTION USE: <br />DATE SIGNED: 4/2/24 <br />OVERALL SITE PLAN <br />N <br />1SCALE: 1" = 30'-0" (11x17) <br />PROJECT SITE, SEE <br />SHEET A-2 FOR <br />ENLARGED SITE PLAN <br />PROPOSED GENERATOR <br />LOCATION, SEE SHEET A-2 <br />FOR ENLARGED SITE PLAN <br />2621 SOUTH BIRCH STREET <br />SANTA ANA, CA 92707 <br />TAX ID#: 410-391-03 <br />NOTE: <br />EVERYTHING SHOWN IS EXISTING <br />UNLESS MARKED PROPOSED <br />EXISTING CONDITIONS: <br />THESE DRAWINGS WERE PRODUCED WITH INFORMATION PROVIDED BY THE <br />CLIENT. LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO START <br />OF CONSTRUCTION, GEOSTRUCTURAL DOES NOT GUARANTEE THE ACCURACY <br />OF SAID PROPERTY LINE, EASEMENTS AND SETBACKS. <br />BUILDING <br />CUMULATIVE VOLUME CALCULATIONS: <br />THE PHYSICAL DIMENSIONS OF THE PROPOSED GENERATOR w/ ENCLOSURE AND <br />BASE FUEL TANK ARE LESS THAN 250 CU. FT. IN VOLUME. <br />BASE FUEL TANK = 106"x36"x25" = 55.2 CU. FT. <br />GENERATOR BODY w/ ENCLOSURE = 94.8"x61.1"x38" = 127.4 CU. FT. <br />TOTAL CUMULATIVE VOLUME OF GENSET = 55.2 + 127.4 = 182.6 CU. FT. <br />GENSET USE, CEQA & BAAQMD EXEMPTION: <br />THE PROPOSED GENERAC SD030 GENSET: <br />* IS RATED AT 49 HP AT MAXIMUM RATED kW OUTPUT, <br />* IS INSTALLED WITH AN ABOVE-GROUND DOUBLE-WALL SECONDARY <br />CONTAINMENT BASE FUEL TANK WITH 190 USABLE (200 MAX) GALLONS OF FUEL, <br />* USES ULTRA LOW SULFUR DIESEL FUEL (15 ppm SULFUR), <br />* IS LIMITED TO 100 HOURS PER YEAR OF NON-EMERGENCY USE (TESTING & <br />MAINTENANCE), <br />* IS INSTALLED WITH A LEVEL 2 ACOUSTIC ENCLOSURE, WHICH BUFFERS SOUND <br />OUTPUT TO A MAXIMUM OF 62 dB AT 7 METERS (~23 FEET), <br />* IS COMPLIANT WITH APPLICABLE AIR QUALITY REGULATIONS, <br />* IS EXEMPT FROM AIR QUALITY PERMITS IN MOST JURISDICTIONS UNDER THE <br />PROVISIONS OF CLASS 1, SEC. 15301 OF THE CALIFORNIA ENVIRONMENTAL <br />QUALITY ACT (CEQA) GUIDELINES, <br />* IS EXEMPT PER BAAQMD REG. 2, RULE 1, SEC. 2-1-114-2.2.1.; LESS THAN 50 BHP. <br />P <br />E <br />AT&T LEASE AREAS <br />EXISTING APPROXIMATE (91.6 SQ.FT.) LEASE AREA <br />PROPOSED 4'-0"x10'-0" (40 SQ.FT.) GENERATOR LEASE AREA <br />EXISTING LEASE AREA SIZES WERE OBTAINED FROM LEASE DOCUMENTS <br />PROVIDED TO GEOSTRUCTURAL AND ARE SHOWN FOR REFERENCE ONLY. <br />REFER TO FINAL LEASE DOCUMENTS FOR APPROVED EXISTING AND PROPOSED <br />LEASE AREAS. <br />E <br />P <br />PARCEL LINE <br />PARCEL LINE <br />PA <br />R <br />C <br />E <br />L <br /> <br />L <br />I <br />N <br />E <br />ASPHALT <br />PAVEMENT <br />STORAGE <br />MATERIAL <br />PAVED <br />PARKING LOT <br />EXISTING MONOPOLE <br />TOWER w/ AT&T ANTENNAS <br />EXISTING <br />WROUGHT-IRON FENCE <br />EXISTING CONCRETE <br />PREFAB EQUIPMENT <br />SHELTER (OTHER CARRIER) <br />2621 S Birch St - 101119515 & <br />20182981 <br />7/24/2024
The URL can be used to link to this page
Your browser does not support the video tag.