Laserfiche WebLink
© 2020 IRONRIDGE, INC. VERSION 3.2 FLUSH MOUNT INSTALLATION MANUAL - 21 <br />MODUL e COMPATIBILITY <br />MAKe MODe LS <br />The Flush Mount System may be used to ground and/or mount a PV module complying with UL 2703 only when the specific module has <br />been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, “xxx” refers to the <br />module power rating and both black and silver frames are included in the certification. <br />FRAMe D MODUL e LIST <br />Adani <br />Adani modules with 35 and 40mm frames <br />ASX-Y-ZZ-xxx <br />Where "X" can be B, M or P, "Y" can be 6 or 7, and "ZZ" can be blank, PERC, B-PERC, or AB-PERC <br />Amerisolar <br />Amerisolar modules with 35, 40 and 50 mm frames <br />AS-bYxxxZ <br />Where "b" can be 5 or 6; "Y" can be M, P, M27, P27, M30, or P30; and "Z" can be blank, W or WB <br />Aptos Solar <br />Aptos modules with 35 and 40 mm frames <br />DNA-yy-zzaa-xxx <br />Where "yy" can be 120 or 144; "zz" can be MF or BF; and "aa" can be 23 or 26 <br />Astronergy Solar <br />Astronergy modules with 30, 35, 40, and 45 mm frames <br />aaSMbbyyC/zz-xxx <br />Where “aa” can be CH or A; "bb" can be 60, 66, or 72; “yy” can be blank, 10 or 12; "C" can M, P, M(BL), <br />M-HC, M(BL)-HC, P-HC, M(DG), or M(DGT); and “zz” can be blank, HV, F-B, or F-BH <br />ASUN <br />ASUN modules with 35 and 40 mm frames <br />ASUN-xxx-YYZZ-aa <br />Where "YY" can be 60 or 72; "ZZ" can be M,or MH5; and "aa" can be blank or BB <br />Auxin <br />Auxin modules with 40 mm frames <br />AXN6y6zAxxx <br />Where "y" can be M or P; "z" can be 08, 09, 10, 11, or 12; and "A" can be F or T <br />Axitec <br />Axitec Modules with 30, 35 and 40 mm frames <br />AC-xxxY/aaZZb <br />Where "Y" can be M, P, MB or MH; "aa" can be blank, 125- or 156-; "ZZ" can be 54, 60, 72, 120, or 144; "b" <br />can be S, X, V, VB, XV, or MX <br />Boviet <br />Boviet modules with 35 and 40mm frames <br />BVM66aaYY-xxxBcc <br />Where "aa" can be 9, 10 or 12; "YY" is M or P; and "B" can be blank, L or S; and "cc" can be blank, H, H-BF, <br />H-BF-DG, H-HC, H-HC-BF, H-HC-BF-DG, HC-BF or HC-BF-DG <br />BYD <br />BYD modules with 35 mm frames <br />BYDxxxAY-ZZ <br />Where "A" can be M6, P6, MH or PH; "Y" can be C or K; and "ZZ" can be 30 or 36 <br />Canadian Solar <br />Canadian Solar modules with 30, 32, 35 and 40 mm frames <br />CSbY-xxxZ <br />Where "b" can be 1, 3 or 6; "Y" can be H, K, L, N, P, U, V, W, X or Y; and "Z" can be M, P, MS, PX , M-SD, <br />P-AG, P-SD, MB-AG, PB-AG, MS-AG, or MS-SD <br />CertainTeed <br />CertainTeed modules with 35 and 40 frames <br />CTxxxYZZ-AA <br />Where "Y" can be M, P, or HC; "ZZ" can be 00,01, 10, or 11; and "AA" can be 01, 02, 03, or 04 <br />CSUN <br />Csun modules with 35 and 40 mm frames <br />YYxxx-zzAbb <br />Where "YY" is CSUN or SST; "zz" is blank, 60, or 72; and "A" is blank, P, M or MM; "bb" is blank, BB, 5BB, <br />BW, or ROOF <br />3000 S Sycamore St Unit# <br />A- 201822724/29/2024