Laserfiche WebLink
DN <br />WH EXIT SEPARATION: 179'-0 3/16"COMPLIES WITH CBC 1007.1.1 Exception #2 <br />DIAGONAL OF AREA SERVED: 205'-2 7/16" <br />(205'-2 7/16"/ 3= 68'-4 13/16" MIN REQ'D EXIT SEPARATION) <br />CODE SUMMARY <br />CONSTRUCTION <br />TYPE TYPE III-A <br />OCCUPANCY TYPE BUSINESS GROUP B <br />OCCUPANCY <br />SEPARATION NON-SEPARATED OCCUPANCY (TABLE 508.3) <br />EXTERIOR BEARING <br />WALLS 2 - HOUR <br />EXTERIOR NON <br />BEARING WALLS <br />PRIMARY STRUCTURAL <br />FRAME <br />X < 5 5 ≤ X ≤ 10 10 ≤ X ≤ 30 X ≥ 30 <br />2 HR RATED <br />(TABLE 602) <br />1 HR RATED <br />(TABLE 602) <br />NON RATED <br />(TABLE 602) <br />NON RATED <br />(TABLE 602) <br />NON RATED (TABLE 601) <br />INTERIOR BEARING <br />WALL NON RATED (TABLE 601) <br />INTERIOR NON <br />BEARING WALL NON RATED (TABLE 601) <br />FLOOR CONSTRUCTION <br />AND SECONDARY <br />MEMBERS <br />NON RATED (TABLE 601) <br />ROOF CONSTRUCTION <br />AND SECONDARY <br />MEMBERS <br />NON RATED (TABLE 601) <br />MIN ROOF COVERING <br />CLASSIFICATION CLASS A <br />MAX TRAVEL <br />DISTANCE <br />EXTERIOR <br />OPENINGS <br />FIRE <br />SPRINKLER NO <br />FIRE ALARM YES <br />B OCCUPANCY - 300 FEET MAX <br />OCCUPANCY TYPES <br />0 < X < 3 3 ≤ X ≤ 5 5 ≤ X ≤ 10 <br />NOT PERMITTED <br />(TABLE 705.8) <br />15% OPEN <br />(TABLE 705.8) <br />25% OPEN <br />(TABLE 705.8) <br />10 ≤ X ≤ 15 <br />45% OPEN <br />(TABLE 705.8) <br />15 < X < 20 <br />75% OPEN (TABLE <br />705.8) <br />20 < X < 25 <br />NO LIMIT <br />(TABLE 705.8) <br />25 < X < 30 <br />NO LIMIT <br />(TABLE 705.8) <br />30 OR GREATER <br />NO LIMIT <br />(TABLE 705.8) <br />OFFICE (B) STORAGE (S) <br />ACCESSIBLE PATH OF TRAVEL <br />MIN. 36" WIDE CLEAR <br />OCCUPANCY LOAD - PLUMBING <br />TOILET ROOMS AND PLUMBING FIXTURES TO REMAIN AS EXISTING. <br />A A <br />1 <br />1 <br />2 <br />23 <br />36 <br />6 4 <br />4 <br />5 <br />5 <br />CC <br />DD <br />EE <br />BB <br />3.5 <br />3.5 <br />OCCS: <br />OCPY: <br />2 170 SF <br />136 Manager's Office <br />1:150 SFB <br />DOOR: <br />OCCS: <br />REQD: <br />PRVD: <br />100A <br />6' - 8" <br />OCCS: <br />OCPY: <br />2 167 SF <br />135 Manager's Office <br />1:150 SFB <br />OCCS: <br />OCPY: <br />5 637 SF <br />132 Open Office <br />1:150 SFB <br />OCCS: <br />OCPY: <br />12 170 SF <br />133 Director's Conference <br />1:15 SFB <br />OCCS: <br />OCPY: <br />2 167 SF <br />134 Director <br />1:150 SFB <br />OCCS: <br />OCPY: <br />1 93 SF <br />127 Electrical <br />1:300 SFS <br />OCCS: <br />OCPY: <br />1 76 SF <br />128 Janitor <br />1:300 SFS <br />OCCS: <br />OCPY: <br />1 99 SF <br />126 Office <br />1:150 SFB <br />OCCS: <br />OCPY: <br />3 315 SF <br />119 DOC Supervisors <br />1:150 SFB <br />OCCS: <br />OCPY: <br />1 131 SF <br />120 Company Central <br />1:150 SFB <br />OCCS: <br />OCPY: <br />2 155 SF <br />118 SRO Office <br />1:150 SFB <br />OCCS: <br />OCPY: <br />2 160 SF <br />117 Company Central <br />1:150 SFB <br />OCCS: <br />OCPY: <br />1 180 SF <br />137 Storage <br />1:300 SFS <br />OCCS: <br />OCPY: <br />9 133 SF <br />114 Break Room <br />1:15 SFB <br />OCCS: <br />OCPY: <br />2 271 SF <br />121 Conference <br />1:150 SFB <br />OCCS: <br />OCPY: <br />29 432 SF <br />111 Overview Room <br />1:15 SFB <br />OCCS: <br />OCPY: <br />39 584 SF <br />102 Break Room <br />1:15 SFB <br />OCCS: <br />OCPY: <br />3 429 SF <br />103 Sub-Operators <br />1:150 SFB <br />OCCS: <br />OCPY: <br />2 419 SF <br />104 Telecom. <br />1:300 SFS <br />OCCS: <br />OCPY: <br />1 203 SF <br />105 Electrical <br />1:300 SFS <br />OCCS: <br />OCPY: <br />3 408 SF <br />107 I.T. Open Office <br />1:150 SFB <br />OCCS: <br />OCPY: <br />1 111 SF <br />109 Chiefs Office <br />1:150 SFB <br />OCCS: <br />OCPY: <br />1 112 SF <br />108 Chiefs Office <br />1:150 SFB <br />OCCS: <br />OCPY: <br />22 3,197 SF <br />110 Control Room <br />1:150 SFB <br />OCCS: <br />OCPY: <br />12 1,715 SF <br />113 D.O.C. <br />1:150 SFB <br />OCCS: <br />OCPY: <br />7 998 SF <br />122 Mapping <br />1:150 SFB <br />OCCS: <br />OCPY: <br />7 941 SF <br />124 Engineering <br />1:150 SFB <br />OCCS: <br />OCPY: <br />4 489 SF <br />125 Engineering <br />1:150 SFB <br />OCCS: <br />OCPY: <br />5 609 SF <br />123 Open Office <br />1:150 SFB <br />OCCS: <br />OCPY: <br />1 140 SF <br />106 I.T. Supv. <br />1:150 SFB <br />TRAVEL DISTANCE=59'-7" <br />DOOR: <br />OCCS: <br />REQD: <br />PRVD: <br />1005 <br />5' - 8" <br />DOOR: <br />OCCS: <br />REQD: <br />PRVD: <br />131A <br />2' - 10" <br />DOOR: <br />OCCS: <br />REQD: <br />PRVD: <br />122A <br />2' - 10" <br />TRAVEL DISTANCE=72'-11" <br />DOOR: <br />OCCS: <br />REQD: <br />PRVD: <br />104A <br />4' - 8" <br />DOOR: <br />OCCS: <br />REQD: <br />PRVD: <br />102B <br />2' - 10" <br />TRAVEL DISTANCE=75'-7" <br />TRAVEL DISTANCE=105'-8" <br />TRAVEL DISTANCE=73'-5" <br />Women <br />130 <br />Men <br />129 <br />Corridor 1 - Hour <br />101 <br />Lobby 1 - Hour <br />100 <br />Corridor 1 - Hour <br />131 <br />Women <br />115 <br />Men <br />116 <br />24 <br />4.8" <br />28 <br />5.6" <br />29 <br />5.8" <br />39 <br />7.8" <br />2 <br />.4" <br />61 <br />12.2" <br />731 South Highway 101, Suite 1M, <br />Solana Beach, CA 92075 <br />(714) 639-9860 <br />ry-aoarchitects.com <br />Plan Check Number: <br />Project Number: <br />20 <br />2 <br />2 <br /> <br />R <br />Y <br />+ <br />A <br />O <br />, <br /> <br />L <br />L <br />P <br />Th <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />a <br />r <br />e <br /> <br />c <br />o <br />p <br />y <br />r <br />i <br />g <br />h <br />t <br /> <br />p <br />r <br />o <br />t <br />e <br />c <br />t <br />e <br />d <br />. <br /> <br /> <br />U <br />n <br />d <br />e <br />r <br /> <br />s <br />u <br />c <br />h <br /> <br />p <br />r <br />ot <br />e <br />c <br />t <br />i <br />o <br />n <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />i <br />z <br />e <br />d <br /> <br />u <br />s <br />e <br /> <br />i <br />s <br /> <br />n <br />o <br />t <br /> <br />p <br />e <br />r <br />m <br />i <br />t <br />t <br />e <br />d <br />. <br /> <br />T <br />h <br />e <br />s <br />e <br /> <br />p <br />la <br />n <br />s <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />o <br />r <br /> <br />u <br />s <br />e <br />d <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />b <br />y <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br /> <br />O <br />r <br />a <br />n <br />g <br />e <br />. <br />c <br />SEAL <br />CONSULTANT <br />Dr <br />a <br />w <br />i <br />n <br />g <br /> <br />F <br />i <br />l <br />e <br /> <br />N <br />a <br />m <br />e <br />: <br />Sh <br />e <br />e <br />t <br /> <br />P <br />l <br />o <br />t <br />t <br />e <br />d <br />: <br />S H E E T <br />-- <br />C: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />r <br />o <br />b <br />e <br />r <br />t <br />s <br />\ <br />O <br />n <br />e <br />D <br />r <br />i <br />v <br />e <br /> <br />- <br /> <br />A <br />O <br />\ <br />D <br />o <br />c <br />u <br />m <br />e <br />n <br />t <br />s <br />\ <br />2 <br />0 <br />2 <br />3 <br />- <br />0 <br />6 <br />4 <br />6 <br /> <br />SC <br />E <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />B <br />l <br />d <br />g <br /> <br />C <br /> <br />S <br />e <br />i <br />s <br />m <br />i <br />c <br /> <br />R <br />e <br />t <br />r <br />o <br />f <br />i <br />t <br />_ <br />a <br />o <br />_ <br />c <br />o <br />m <br />m <br />_ <br />r <br />o <br />b <br />e <br />r <br />ts <br />. <br />r <br />v <br />t <br />6/ <br />1 <br />1 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />5 <br />: <br />4 <br />0 <br />: <br />1 <br />5 <br /> <br />P <br />M <br />LI <br />F <br />E <br /> <br />S <br />A <br />F <br />E <br />T <br />Y <br /> <br />P <br />L <br />A <br />N <br />2023-0646 <br />8631 RUSH STREET <br />ROSEMEAD, CA 91770 <br />626-302-3687 <br />SOUTHERN CALIFORNIA EDISON <br />SC <br />E <br /> <br />- <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />B <br />l <br />d <br />g <br /> <br />C <br /> <br />V <br />o <br />l <br />u <br />n <br />t <br />a <br />r <br />y <br />Se <br />i <br />s <br />m <br />i <br />c <br /> <br />R <br />e <br />t <br />r <br />o <br />f <br />i <br />t <br />13 <br />2 <br />7 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />G <br />R <br />A <br />N <br />D <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />101119260 <br />LS1.0 <br />2024-01-24 Issue for Plan Check <br />2024-02-21 Issue for City Planning <br />2024-06-11 Re-Issue for Plan Check <br />N <br />GENERAL NOTES <br />1. THIS PLAN IS FOR GENERAL CONFORMANCE ONLY <br />2. FLOOR AREAS ARE BASED ON BUILDING CODE REQUIREMENTS ONLY AND ARE MEASURED TO THE <br />INTERIOR OF EXTERIOR / PERIMETER WALLS AND THE CENTER LINE OF DEMISING WALLS. <br />3. THE EXIT TRAVEL PATH AND COMMON EGRESS PATH ARE ESTIMATES ONLY. ACTUAL PATHS MAY BE <br />SUBJECT TO MINOR REVISION BASED UPON TENANT FURNITURE. <br />4. FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE PARTITIONS, AND SMOKE BARRIERS OR ANY <br />OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE PERMANENTLY <br />IDENTIFIED WITH SIGNS OR STENCILING IN THE FLOOR / CEILING SPACE EVERY 30-FEET (MAXIMUM) <br />WITH LETTERING AT LEAST 1/2" HIGH IN HEIGHT (703) CFC / (703.7) CBC. <br />5. THE MEANS OF EGRESS WILL BE ILLUMINATED TO A LEVEL OF NOT LESS THAN ONE FOOT-CANDLE AT <br />THE WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS <br />OCCUPIED. <br />6. LIGHTING FIXTURES CONNECTED TO AN EMERGENCY POWER SYSTEM (STORAGE BATTERIES, UNIT <br />EQUIPMENT OR AN ON-SITE GENERATOR) WILL AUTOMATICALLY ILLUMINATE THE MEANS OF EGRESS <br />FOR A DURATION OF NOT LESS THAN 90 MINUTES <br />OCCUPANT LOAD TABLE <br />Name RM # Area Primary Occ. Occ. Load <br />Total <br />Occupants <br />B <br />Manager's Office 136 170 SF B 150 SF 2 <br />Manager's Office 135 167 SF B 150 SF 2 <br />Open Office 132 637 SF B 150 SF 5 <br />Director's Conference 133 170 SF B 15 SF 12 <br />Director 134 167 SF B 150 SF 2 <br />Office 126 99 SF B 150 SF 1 <br />DOC Supervisors 119 315 SF B 150 SF 3 <br />Company Central 120 131 SF B 150 SF 1 <br />SRO Office 118 155 SF B 150 SF 2 <br />Company Central 117 160 SF B 150 SF 2 <br />Break Room 114 133 SF B 15 SF 9 <br />Conference 121 271 SF B 150 SF 2 <br />Overview Room 111 432 SF B 15 SF 29 <br />Chiefs Office 108 112 SF B 150 SF 1 <br />Sub-Operators 103 429 SF B 150 SF 3 <br />Break Room 102 584 SF B 15 SF 39 <br />I.T. Open Office 107 408 SF B 150 SF 3 <br />D.O.C. 113 1715 SF B 150 SF 12 <br />Mapping 122 998 SF B 150 SF 7 <br />Engineering 124 941 SF B 150 SF 7 <br />Engineering 125 489 SF B 150 SF 4 <br />Open Office 123 609 SF B 150 SF 5 <br />I.T. Supv. 106 140 SF B 150 SF 1 <br />S <br />Janitor 128 76 SF S 300 SF 1 <br />Electrical 127 93 SF S 300 SF 1 <br />Storage 137 180 SF S 300 SF 1 <br />Electrical 105 203 SF S 300 SF 1 <br />Telecom. 104 419 SF S 300 SF 2 <br />10405 SF 160 <br />Scale: <br />1/8" = 1'-0"1LIFE SAFETY PLAN <br />SYMBOLS LEGEND <br />PATH OF TRAVEL <br />EXISTING CONSTRUCTION <br />NON-RATED WALLS <br />1 HR FIRE RATED WALLS <br />FUTURE 1 HR RATED WALLS <br />EGRESS AREA TAG <br />EGRESS ELEMENT TAG Stair # <br />O: 00 <br />R: 00 <br />P: 00 <br />COMPONENT NAME <br /># OF OCCUPANTS <br />EGRESS WIDTH REQUIRED <br />EGRESS WIDTH PROVIDED <br />OCCS:### <br />OCCUPANCY GROUP & <br />OCCUPANCY LOAD FACTOR <br /># OF OCCUPANTS <br />ROOM NAME <br />RM <br />. <br /> <br /># <br />M @ 1:50 S.F. <br />2 HR FIRE RATED WALLS <br />FUTURE 2 HR RATED WALLS <br />EXIT SIGN <br />REN. 4/30/25 <br />No. C-11043 <br />RICHARD S.YEN <br />STATE OF CALIFORNIA <br />REGISTERED ARCHITEC <br />T <br />2024-06-11 <br />1327 S Grand Ave <br />12/12/2024