Laserfiche WebLink
18 <br />" <br /> <br />M <br />A <br />X <br />. <br />17 <br />" <br /> <br />M <br />I <br />N <br />. <br />59" MIN. @ FLOOR MOUNTED WATER CLOSET <br />56" MIN. @ WALL MOUNTED WATER CLOSET <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />R <br />. <br />MANEUVERING SPACE <br />60" MIN. CLR @ SIDE OPENING DOOR <br />K. TOILET COMPARTMENT <br />WITH SIDE OUT-SWINGING <br />DOOR <br />J. TOILET COMPARTMENT WITH SIDE IN- <br />SWINGING DOOR <br />18 <br />" <br /> <br />M <br />A <br />X <br />. <br />17 <br />" <br /> <br />M <br />I <br />N <br />. <br />59" MIN. @ FLOOR MOUNTED WATER CLOSET <br />56" MIN. @ WALL MOUNTED WATER CLOSET <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />R <br />. <br />MANEUVERING SPACE <br />60" MIN. CLR @ SIDE OPENING DOOR <br />PARTITION DOOR IS PERMITTED TO SWING INTO <br />HATCHED PORTION OF MANEUVERING SPACE <br />DOOR SWINGS IN <br />36" MIN. WHEN <br />M. TOILET COMPARTMENT WITH END <br />OUT-SWINGING DOOR <br />CLEARANCE <br />ZONE <br />AROUND <br />WATER <br />CLOSET <br />L. TOILET COMPARTMENT WITH END IN- <br />SWINGING DOOR <br />18 <br />" <br /> <br />M <br />A <br />X <br />. <br />17 <br />" <br /> <br />M <br />I <br />N <br />. <br />59" MIN. @ FLOOR MOUNTED WATER CLOSET <br />56" MIN. @ WALL MOUNTED WATER CLOSET <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />R <br />. <br />PARTITION DOOR IS PERMITTED TO SWING INTO <br />HATCHED PORTION OF MANEUVERING SPACE <br />MANEUVERING SPACE <br />48" MIN. CLR @ END OPENING DOOR <br />P. AMBULATORY ACCESSIBLE TOILET <br />COMPARTMENT <br />37" MIN. CLR. <br />35" MIN. CLR. <br />SI <br />D <br />E <br /> <br />A <br />P <br />P <br />R <br />O <br />A <br />C <br />H <br />44 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />R <br />WH <br />E <br />N <br /> <br />L <br />A <br />T <br />C <br />H <br />MA <br />X <br />. <br />12 <br />" <br />42 <br />" <br /> <br />M <br />I <br />N <br />. <br />DOOR SHALL NOT <br />SWING INTO <br />CLEARANCE <br />ZONE <br />CLEARANCE <br />ZONE <br />19" MAX. <br />17" MIN. <br />CL <br />R <br />. <br />, <br /> <br />T <br />Y <br />P <br />. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />N. ACCESSIBLE TOILET COMPARTMENT TOE <br />CLEARANCE <br />9" <br /> <br />M <br />I <br />N <br />. <br />6" MIN. <br />ELEVATION <br />ADULT <br />12 <br />" <br /> <br />M <br />I <br />N <br />. <br />6" MIN. <br />ELEVATION <br />CHILDREN <br />SUGGESTED DIMENSIONS FOR CHILDREN AGES 3 THROUGH 12 <br />Ages 9 through 12Ages 5 through 8Ages 3 and 4 <br />Water Closet Centerline 12 inches 12 to 15 inches 15 to 18 inches <br />Toilet Seat Height 11 to 12 inches 12 to 15 inches 15 to 17 inches <br />Grab Bar Height 18 to 20 inches 20 to 25 inches 25 to 27 inches <br />Dispenser Height 14 inches 14 to 17 inches 17 to 19 inches <br />6" <br />PLAN <br />TOE CLEARANCE <br />NOT REQUIRED AT <br />PARTITION <br />SUPPORTS <br />18 <br />" <br /> <br />M <br />A <br />X <br />. <br />17 <br />" <br /> <br />M <br />I <br />N <br />. <br />59" MIN. @ FLOOR MOUNTED WATER CLOSET <br />56" MIN. @ WALL MOUNTED WATER CLOSET <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />R <br />. <br />MANEUVERING SPACE <br />48" MIN. CLR @ END OPENING DOOR <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />R <br />. <br />DOOR SWINGS IN <br />36" MIN. WHEN <br />34" CLR. <br />MIN. <br />34" CLR. <br />MIN. <br />CLEARANCE ZONE <br />AROUND WATER <br />CLOSET <br />CLEARANCE ZONE <br />AROUND WATER <br />CLOSET <br />OF <br /> <br />G <br />R <br />A <br />B <br /> <br />B <br />A <br />R <br />33 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />& <br />36 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br />TO <br />P <br /> <br />O <br />F <br /> <br />S <br />E <br />A <br />T <br />17 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />& <br />19 <br />" <br /> <br />M <br />A <br />X <br /> <br />T <br />O <br />48" MIN. <br />MAX. <br />12" <br />24" MIN. <br />CL <br /> <br />O <br />F <br /> <br />R <br />O <br />L <br />L <br />19 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />T <br />O <br />9" MAX. <br />7" MIN. <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br />MI <br />N <br />. <br />1 <br />1 <br />/ <br />2 <br />" <br />MAX. <br />6"OF GRAB BAR <br />36" MIN. TO C.L. <br />TO <br />P <br /> <br />O <br />F <br /> <br />S <br />E <br />A <br />T <br />17 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />& <br />19 <br />" <br /> <br />M <br />A <br />X <br /> <br />T <br />O <br />CL <br /> <br />O <br />F <br /> <br />R <br />O <br />L <br />L <br />19 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />T <br />O <br />OF <br /> <br />G <br />R <br />A <br />B <br /> <br />B <br />A <br />R <br />33 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />& <br />36 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br />RECESSED SANITARY <br />TOILET SEAT COVER <br />AND TOILET TISSUE <br />DISPENSER <br />1 1/2" DIAM. WALL MOUNTED <br />GRAB BARS. PROVIDE <br />BLOCKING AT STUD WALL. <br />ACCESSIBLE WATER CLOSET <br />RECESSED <br />SANITARY TOILET <br />SEAT COVER AND <br />TOILET TISSUE <br />DISPENSER <br />1 1/2" DIAM. WALL <br />MOUNTED GRAB BARS. <br />PROVIDE BLOCKING AT <br />STUD WALL. <br />1 1/2" DIAM. WALL MOUNTED <br />GRAB BARS. PROVIDE <br />BLOCKING AT STUD WALL. <br />18" MAX. <br />17" MIN.ACCESSIBLE WATER <br />CLOSET. FLUSH <br />VALVE HANDLE SHALL <br />BE ON SIDE AWAY <br />FROM WALL <br />OF <br /> <br />G <br />R <br />A <br />B <br /> <br />B <br />A <br />R <br />33 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />& <br />36 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />C <br />. <br />L <br />. <br />TO <br />P <br /> <br />O <br />F <br /> <br />S <br />E <br />A <br />T <br />17 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />& <br />19 <br />" <br /> <br />M <br />A <br />X <br /> <br />T <br />O <br />42" MIN. TO CL OF GRAB BAR <br />MAX. <br />12" <br />24" MIN. <br />F.O.F. WALL OR F.O. PARTITION <br />MAX. <br />6"GRAB BAR <br />36" MIN. <br />TO <br />P <br /> <br />O <br />F <br /> <br />S <br />E <br />A <br />T <br />17 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />& <br />19 <br />" <br /> <br />M <br />A <br />X <br /> <br />T <br />O <br />OF <br /> <br />G <br />R <br />A <br />B <br /> <br />B <br />A <br />R <br />33 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />& <br />36 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />C <br />. <br />L <br />. <br />1 1/2" DIAM. WALL MOUNTED <br />GRAB BARS. PROVIDE <br />BLOCKING AT STUD WALL. <br />ACCESSIBLE WATER CLOSET <br />1 1/2" DIAM. WALL <br />MOUNTED GRAB BARS. <br />PROVIDE BLOCKING AT <br />STUD WALL. <br />1 1/2" DIAM. WALL MOUNTED <br />GRAB BARS. PROVIDE <br />BLOCKING AT STUD WALL. <br />18" MAX. <br />17" MIN. <br />9" MAX <br />7" MIN. <br />WALL MOUNTED TOILET <br />PAPER DISPENSER <br />(WITHOUT STOPS) <br />C. <br />L <br />. <br /> <br />O <br />F <br /> <br />R <br />O <br />L <br />L <br />19 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />T <br />O <br /> <br />OF <br /> <br />D <br />I <br />S <br />P <br />E <br />N <br />S <br />E <br />R <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br />F.O.F. WALL <br />F.O.F. WALL OR F.O. PARTITION F.O.F. WALL <br />19" MAX. @ <br />AMBULATORY <br />STALLS <br />WALL MOUNTED <br />SANITARY TOILET <br />SEAT DISPENSER AS <br />OCCURS <br />ACCESSIBLE WATER <br />CLOSET. FLUSH <br />ACTIVATOR HANDLE <br />TO BE ON SIDE AWAY <br />FROM WALL <br />OF <br /> <br />D <br />I <br />S <br />P <br />E <br />N <br />S <br />E <br />R <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br />COMBINATION PAPER <br />TOWEL DISPENSER AND <br />WASTE RECEPTACLE <br />AL <br />L <br /> <br />O <br />P <br />E <br />R <br />A <br />B <br />L <br />E <br /> <br />P <br />A <br />R <br />T <br />S <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br /> <br />O <br />F <br />WALL MOUNTED <br />VENDING MACHINE <br />DIAPER CHANGING <br />STATION <br />WALL MOUNTED <br />CHILD SEAT <br />1' <br />- <br />3 <br />" <br />WH <br />E <br />N <br /> <br />O <br />P <br />E <br />N <br />27 <br />" <br /> <br />T <br />O <br /> <br />B <br />O <br />T <br />T <br />O <br />M <br />OF <br /> <br />S <br />H <br />E <br />L <br />F <br /> O <br />F <br /> <br />D <br />I <br />S <br />P <br />E <br />N <br />S <br />E <br />R <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br />OF <br /> <br /> <br />R <br />O <br />L <br />L <br />19 <br />" <br /> <br />T <br />O <br /> <br />C <br />. <br />L <br />. <br />SANITARY TOILET SEAT <br />COVER AND TOILET <br />TISSUE DISPENSER <br />WALL MOUNTED <br />PAPER TOWEL <br />DISPENSER <br />OF <br /> <br />R <br />E <br />C <br />E <br />P <br />T <br />A <br />C <br />L <br />E <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br /> <br />SANITARY NAPKIN <br />DISPOSAL <br /> O <br />F <br /> <br />D <br />I <br />S <br />P <br />E <br />N <br />S <br />E <br />R <br />28 <br />" <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br /> <br />OF <br /> <br />D <br />I <br />S <br />P <br />E <br />N <br />S <br />E <br />R <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br /> <br />SANITARY TOILET <br />SEAT DISPENSER <br />GRAB BARS <br />TOILET PAPER <br />DISPENSER <br />WALL MOUNTED <br />SOAP DISPENSER <br />TO <br />P <br /> <br />O <br />F <br /> <br />G <br />R <br />A <br />B <br /> <br />B <br />A <br />R <br />34 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />& <br />36 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br />OF <br /> <br />R <br />O <br />L <br />L <br />19 <br />" <br /> <br />T <br />O <br /> <br />C <br />L <br />TO <br />P <br /> <br />O <br />F <br /> <br />D <br />I <br />S <br />P <br />E <br />N <br />S <br />E <br />R <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />OF <br /> <br />F <br />I <br />X <br />T <br />U <br />R <br />E <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br />CL <br />E <br />A <br />R <br />A <br />N <br />C <br />E <br />29 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />K <br />N <br />E <br />E <br />LAVATORYHAND DRYER <br />OP <br />E <br />R <br />A <br />B <br />L <br />E <br /> <br />P <br />A <br />R <br />T <br />S <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />A <br />L <br />L <br /> <br />TO <br />P <br /> <br />O <br />F <br /> <br />S <br />E <br />A <br />T <br />17 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />& <br />19 <br />" <br /> <br />M <br />A <br />X <br /> <br />T <br />O <br />WATER CLOSET CHILD WATER CLOSET <br />SE <br />A <br />T <br />1' <br />- <br />0 <br />" <br /> <br />T <br />O <br />TO <br />P <br /> <br />O <br />F <br />17 <br />" <br /> <br />M <br />A <br />X <br />. <br />C. <br />L <br />. <br /> <br />O <br />F <br /> <br />H <br />A <br />N <br />D <br />L <br />E <br />44 <br />" <br /> <br />M <br />A <br />X <br /> <br />T <br />O <br />URINAL <br />15 <br />" <br /> <br />M <br />A <br />X <br />. <br />13 <br />" <br /> <br />M <br />I <br />N <br />. <br />CHILDREN URINAL <br />WALL MOUNTED <br />MIRROR <br /> O <br />F <br /> <br />D <br />I <br />S <br />P <br />E <br />N <br />S <br />E <br />R <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br />WALL MOUNTED <br />WASTE RECEPTACLE <br />A. TYPICAL TOILET ROOM ACCESSORY MOUNTING HEIGHTS <br />E. TYPICAL WATER CLOSET REQUIREMENTS <br />C. TYPICAL LAV REQUIREMENTS B. TYPICAL URINAL REQUIREMENTS <br />NO <br />T <br /> <br />A <br />T <br /> <br />L <br />A <br />V <br />S <br /> <br />& <br /> <br />C <br />O <br />U <br />N <br />T <br />E <br />R <br />T <br />O <br />P <br />S <br />35 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />B <br />O <br />T <br />T <br />O <br />M <br /> <br />E <br />D <br />G <br />E <br /> <br />OF <br /> <br />R <br />E <br />F <br />L <br />E <br />C <br />T <br />I <br />N <br />G <br /> <br />S <br />U <br />R <br />F <br />A <br />C <br />E <br />AT <br /> <br />L <br />A <br />V <br />S <br /> <br />& <br /> <br />C <br />O <br />U <br />N <br />T <br />E <br />R <br />T <br />O <br />P <br />S <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />B <br />O <br />T <br />T <br />O <br />M <br /> <br />E <br />D <br />G <br />E <br /> <br />OF <br /> <br />R <br />E <br />F <br />L <br />E <br />C <br />T <br />I <br />N <br />G <br /> <br />S <br />U <br />R <br />F <br />A <br />C <br />E <br />HO <br />O <br />K <br /> <br />F <br />O <br />R <br /> <br />A <br />D <br />U <br />L <br />T <br />S <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br /> <br />O <br />F <br />COAT HOOK <br />HE <br />I <br />G <br />H <br />T <br />S <br /> <br />F <br />O <br />R <br /> <br />C <br />H <br />I <br />L <br />D <br />R <br />E <br />N <br />SE <br />E <br /> <br />1 <br />1 <br />B <br />- <br />3 <br />0 <br />8 <br /> <br />F <br />O <br />R <br /> <br />A <br />L <br />T <br />. <br />NOTE: REFER TO 11B-308 FOR ALTERNATE HEIGHTS FOR ACCESSORIES FOR USE BY CHILDREN <br />WH <br />E <br />N <br /> <br />O <br />P <br />E <br />N <br />26 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />A <br />N <br />D <br /> <br />3 <br />0 <br />" <br />MA <br />X <br />. <br /> <br />T <br />O <br /> <br />S <br />U <br />R <br />F <br />A <br />C <br />E <br />EX <br />C <br />E <br />E <br />D <br /> <br />4 <br />0 <br />" <br />OP <br />E <br />R <br />A <br />B <br />L <br />E <br /> <br />PA <br />R <br />T <br />S <br /> <br />M <br />A <br />Y <br />1 1/2" DIAM. WALL <br />MOUNTED GRAB BARS. <br />PROVIDE BLOCKING AT <br />STUD WALL. <br />19" MAX. @ <br />AMBULATORY <br />STALLS <br />1 1/2" DIAM. WALL <br />MOUNTED GRAB BARS. <br />PROVIDE BLOCKING AT <br />STUD WALL. <br />WALL MOUNTED, FRONT ELEVATION WALL MOUNTED, SIDE ELEVATION <br />FLOOR MOUNTED, FRONT ELEVATION FLOOR MOUNTED, SIDE ELEVATION <br />12 <br />" <br />44 <br />" <br /> <br />M <br />A <br />X <br /> <br />T <br />O <br /> <br />C <br />. <br />L <br />. <br /> <br />O <br />F <br /> <br />H <br />A <br />N <br />D <br />E <br />L <br />17 <br />" <br /> <br />M <br />A <br />X <br />. <br />MIN. <br />13 1/2" <br />URINAL <br />PARTITION AS <br />OCCURS <br />F.O.F. <br />WALL <br />WALL MOUNTEDSTALL TYPE <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />C <br />. <br />L <br />. <br /> <br />O <br />F <br /> <br />H <br />A <br />N <br />D <br />E <br />L <br />OF <br /> <br />F <br />I <br />X <br />T <br />U <br />R <br />E <br /> <br />R <br />I <br />M <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br />FR <br />O <br />N <br />T <br /> <br />E <br />D <br />G <br />E <br /> <br />O <br />F <br /> <br />L <br />A <br />V <br />. <br />29 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />A <br />T <br />EQ EQ <br />OF <br /> <br />F <br />I <br />X <br />T <br />U <br />R <br />E <br /> <br />R <br />I <br />M <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />O <br />P <br />WALL MOUNTED LAVATORY. ACCESSIBLE HOT WATER <br />AND DRAIN PIPES UNDER LAVATORIES SHALL BE <br />INSULATED OR OTHERWISE COVERED. THERE SHALL <br />BE NO SHARP OR ABRASIVE SURFACES UNDER THE <br />LAVATORY. FACET CONTROLS AND OPERATION <br />MECHANISMS SHALL BE OPERABLE WITH ONE HAND <br />AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, <br />OR TWISTING OF THE WRIST. <br />F.O.F. <br />WALL <br />KNEE AND TOE CLEARANCE <br />ZONE PER 11B-306 30" MIN. <br />PLAN <br />CL <br />R <br />. <br />18 <br />" <br /> <br />M <br />I <br />N <br />. <br />CL <br />R <br />. <br />18 <br />" <br /> <br />M <br />I <br />N <br />. <br />WALL OR PARTITION <br />AS OCCURS <br />WALL OR PARTITION <br />AS OCCURS <br />PLAN <br />CL <br />R <br />. <br />18 <br />" <br /> <br />M <br />I <br />N <br />. <br />17" MIN. & 19" MAX. TOE CLEARANCE <br />11" MIN. & 25" MAX. KNEE CLEARANCE <br />WALL OR PARTITION <br />AS OCCURS <br />URINAL <br />PARTITION AS <br />OCCURS <br />F.O.F. <br />WALL <br /> 36" MIN. OTHERWISE <br />ACCESSIBLE ROUTE: 44" MIN. <br />ACC. TOILET COMPARTMENT, <br />BABY CHANGING <br />STATION, WHEN <br />DEPLOYED SHALL NOT <br />REDUCE THE <br />ACCESSIBLE ROUTE <br />REQUIRED WIDTH <br />D. ACCESS. ROUTE REQUIREMENTS <br />MIN. <br />13 1/2" <br />11B-604 WATER CLOSETS AND TOILET <br />COMPARTMENTS <br />1. The water closet shall be positioned with a wall or <br />partition to the rear and to one side. The centerline <br />of the water closet shall be 17 inches minimum to 18 <br />inches maximum from the side wall or partition, <br />except that the water closet shall be 17 inches <br />minimum and 19 inches maximum from the side wall <br />or partition in the ambulatory accessible toilet <br />compartment specified in Section 11B-604.8.2 <br />Ambulatory Accessible Compartments. Water <br />closets shall be arranged for a left-hand or right- <br />hand approach. §11B-604.2 <br />2. Clearance around a water closet shall be 60 inches <br />minimum measured perpendicular from the side wall <br />and 56 inches minimum measured perpendicular <br />from the rear wall. A minimum 60 inches wide and <br />48 inches deep maneuvering space shall be <br />provided in front of the water closet.§11B-604.3.1 <br />3. The seat height of a water closet above the finish <br />floor shall be 17 inches minimum and 19 inches <br />maximum measured to the top of the seat. Seats <br />shall not be sprung to return to a lifted position. <br />Seats shall be 2 inches high maximum and a 3 inch <br />high seat shall be permitted only in alterations where <br />the existing fixture is less than 15 inches high. § <br />11B-604.4 (see exception for Residential Units) <br />4. The side wall grab bars shall be 42 inches long <br />minimum, located 12 inches maximum from the rear <br />wall and extending 54 inches minimum from the rear <br />wall with the front end positioned 24 inches minimum <br />in front of the water closet. §11B-604.5.1 <br />5. The rear grab bar shall be 36 inches long minimum <br />and extend from the centerline of the water closet 12 <br />inches minimum on one side and 24 inches <br />minimum on the other side. §11B-604.5.2 (See <br />exceptions) <br />6. Flush controls shall be hand operated or automatic. <br />Hand operated flush controls shall comply with <br />Section 11B-309.4 except they shall be located 44 <br />inches maximum above the floor. Flush controls <br />shall be located on the open side of the water closet <br />except in ambulatory accessible compartments <br />complying with Section 11B-604.8.2 . §11B-604.6 <br />7. Toilet paper dispensers shall comply with Section <br />11B-309.4 Operation and shall be 7 inches minimum <br />and 9 inches maximum in front of the water closet <br />measured to the centerline of the dispenser. The <br />outlet of the dispenser shall be below the grab bar, <br />19 inches minimum above the finish floor and shall <br />not be located behind the grab bars. Dispensers <br />shall not be of a type that control delivery or that <br />does not allow continuous paper flow. §11B-604.7 <br />8. Wheelchair accessible compartments shall be 60 <br />inches wide minimum measure perpendicular to the <br />side wall, and 56 inches deep minimum for wall hung <br />water closets and 59 inches deep minimum for floor <br />mounted water closets measured perpendicular to <br />the rear wall. Wheelchair accessible compartments <br />for children's use shall be 60 inches wide minimum <br />measured perpendicular to the side wall, and 59 <br />inches deep minimum for wall hung and floor <br />mounted water closets measured perpendicular to <br />the rear wall. §11B- 604.8.1.1 <br />9. In a wheelchair accessible compartment with an in- <br />swing door, a minimum 60 inches wide by 36 inches <br />deep maneuvering space shall be provided in front <br />of the clearance required in Section 11B-604.8.1.1. § <br />11B-604.8.1.1.1, Figures 11B- 604.8.1.1.2(b) and <br />11B-604.8.1.1.3(b) <br />10. In a wheelchair accessible compartment with a side- <br />opening door, either in-swinging or out- swinging, a <br />minimum 60 inches wide and 60 inches deep <br />maneuvering space shall be provided in front of the <br />water closet. §11B-604.8.1.1.2, Figure 11B- <br />604.8.1.1.2 <br />11. In a wheel chair accessible compartment with end- <br />opening door (facing water closet), either in- <br />swinging or out-swinging, a minimum 60 inches wide <br />and 48 inches deep maneuvering space shall be <br />provided in front of the water closet. §11B- <br />604.8.1.1.3, Figure 11B-604.8.1.1.3 <br />11B-603 TOILET AND BATHING ROOMS <br />1. The clear width for accessible routes to accessible <br />toilet compartments shall be 44 inches minimum <br />except for door-opening widths and door swings. § <br />11B-403.5.1, exception 5 <br />2. Where toilet facilities and bathing facilities are <br />provided, they shall comply with 11B-213. Where <br />toilet facilities and bathing facilities are provided in <br />facilities permitted by 11B-206.2.3 exceptions 1 and <br />not to connect stories by an accessible route, toilet <br />facilities and bathing facilities shall be provided on a <br />story connected by an accessible route to an <br />accessible entrance. §11B-213.1 <br />3. Where separate toilet facilities are provided for the <br />exclusive use of separate user groups, the toilet <br />facilities serving each user group shall comply with <br />11B-213. §11B-213.1.1 <br />4. Where toilet rooms are provided, each toilet room <br />shall comply with 11B-603.. Where bathing rooms <br />are provided, each bathing room shall comply with <br />11B-603. §11B-213.2 (see exceptions) <br />5. Unisex toilet rooms shall contain not more than one <br />lavatory, and not more than two water closets <br />without urinals or one water closet and one urinal. <br />Unisex bathing rooms shall contain one shower or <br />one shower and one bathtub, one lavatory, and one <br />water closet. Doors to unisex toilet rooms and unisex <br />bathing rooms shall have privacy latches. § <br />11B-213.2.1 <br />6. Turning space complying with Section 11B-304 shall <br />be provided within the room. §11B-603.2.1 <br />7. Required clear floor spaces, clearance at fixtures, <br />and turning space shall be permitted to overlap. § <br />11B-603.2.2 <br />8. Door shall not swing into the clear floor space or <br />clearance required for any fixture. Doors to <br />accessible water closet compartments shall be <br />permitted to encroach into the turning space without <br />limitation. Other than the door to the accessible <br />water closet compartment, a door in any position, <br />may encroach into the turning space by 12 inches <br />maximum. §11B-603.2.3 <br />9. At single user toilet or bathing rooms, doors shall be <br />permitted to swing into the clear floor space or <br />clearance required for any fixture only if a 30 inch by <br />48 inch minimum clear floor space is provided within <br />the room beyond the arc of the door swing. § <br />11B-603.2.3, exception <br />10. Mirrors located above the lavatories or countertops <br />shall be installed within the bottom edge of the <br />reflecting surface 40 inches maximum above the <br />finish floor or ground. Mirrors not located above the <br />lavatories or countertops shall be installed with the <br />bottom edge of the reflecting surface 35 inches <br />maximum above the finish floor or ground. §11B- <br />603.3 <br />11. Coat hooks shall be located within one of the reach <br />ranges specified in Section 11B-308. Shelves shall <br />be located 40 inches minimum and 48 inches <br />maximum above the finish floor. Medicine cabinets <br />shall be located with a usable shelf no higher than <br />44 inches maximum above the finish floor. §11B- <br />603.4 <br />12. Where towel or sanitary napkin dispensers, waste <br />receptacles, or other accessories are provided in <br />toilet facilities, at least one of each type shall be <br />located on an accessible route. All operable parts, <br />including coin slots, shall be 40 inches maximum <br />above the finish floor. Exception: Baby changing <br />tables are not required to comply with Section <br />11B-603.5. §11B-603.5 <br />13. Baby changing tables shall comply with Sections <br />11B-309 and 11B-902. Baby changing tables when <br />deployed shall not obstruct the required width of an <br />accessible route except as allowed by Section <br />11B-307.2. Baby changing tables shall not be <br />located in toilet compartments complying with <br />Section 11B-604.8 within a multiple accommodation <br />toilet facility. §11B-226.4 <br />12. Toilet compartment doors, including door hardware, <br />shall comply with Section 11B-404 except that if the <br />approach is from the push side of the compartment <br />door, clearance between the door side of the <br />compartment and any obstruction shall be 48 inches <br />minimum measured perpendicular to the <br />compartment door in its closed position. Door shall <br />be located in front partition or in the side wall or <br />partition farthest from the water closet. Where toilet <br />compartment doors are located in the front partition, <br />the door opening shall be 4 inches maximum from <br />the side wall or partition farthest from the water <br />closet. Where located in the side wall or partition, the <br />door opening shall be 4 inches maximum from the <br />front partition and the door shall be self-closing. A <br />door pull complying with Section 11B-404.2.7 shall <br />be placed on both sides of the door near the latch. <br />Door shall not swing into the clear floor space or <br />clearance required for any fixture. Doors may swing <br />into that portion of the maneuvering space which <br />does not overlap the clearance required at a water <br />closet. §11B-604.8.1.2 <br />13. At least one side partition shall provide a toe <br />clearance of 9 inches minimum above the finish floor <br />and 6 inches deep minimum beyond the <br />compartment-side face of the partition, exclusive of <br />partition support members. Partition components at <br />toe clearances shall be smooth without sharp edges <br />or abrasive surfaces. Compartments for children's <br />use shall provide a toe clearance of 12 inches <br />minimum above the finish floor. Exception: Toe <br />clearance at the side partition is not required in a <br />compartment greater than 66 inches wide. §11B- <br />604.8.1.4 <br />14. Ambulatory accessible compartments: <br />a. Shall have a depth of 60 inches minimum and a <br />width of 35 inches minimum and 37 inches <br />maximum. §11B-604.8.2.1 <br />b. Doors, including door hardware, shall comply <br />with Section 11B-404, except that if the <br />approach is to the latch side of the compartment <br />door, clearance between the door side of the <br />compartment and any obstruction shall be 44 <br />inches minimum. The door shall be self-closing. <br />A door pull complying with Section 11B-404.2.7 <br />shall be placed on both sides of the door near <br />the latch. Toilet compartment doors shall not <br />swing into the minimum required compartment <br />area. §11B-604.8.2.2 <br />c. A side-wall grab bar complying with Section <br />11B-604.5.1 shall be provided on both sides of <br />the compartment. §11B-604.8.2.3 <br />15. Water closets and toilet compartments for children's <br />use shall comply with Section 11B-604.9. When the <br />exception in Section 11B-604.1 is used, the <br />suggested dimensions of Table 11B-604.9 for a <br />single age group shall be applied consistently to the <br />installation of a water closet and all associated <br />components. §11B-604.9 <br />11B-605 URINALS <br />1. Urinals shall be the stall-type or the wall-hung type <br />with the rim 17 inches maximum above the finish <br />floor or ground. Urinals shall be 13½ inches deep <br />minimum measured from the outer face of the urinal <br />rim to the back of the fixture. §11B-605.2 <br />2. Urinal flush controls shall be hand operated or <br />automatic. Hand operated flush controls shall comply <br />with Section 11B-309 except that the flush control <br />shall be mounted at a maximum height of 44 inches <br />above the finish floor. §11B-605.4 <br />11B-606 LAVATORIES AND SINKS <br />1. Where lavatories are provided, at least 10 percent <br />but no fewer than one shall comply with Section <br />11B-606 and shall not be located in a toilet <br />compartment. §11B-213.3.4 <br />2. For lavatories and sinks, a clear floor space <br />complying with Section 11B-305, positioned for a <br />forward approach, and knee and toe clearance <br />complying with Section 11B-306 shall be provided. § <br />11B-606.2 (see exceptions) <br />3. Lavatories and sinks shall be installed with the front <br />of the higher of the rim or counter surface 34 inches <br />maximum above the finish floor or ground. §11B- <br />606.3 <br />4. Water supply and drain pipes under lavatories and <br />sinks shall be insulated or otherwise configured to <br />protect against contact. There shall be no sharp or <br />abrasive surfaces under lavatories and sinks. <br />§11B- 606.5 <br />5. Where sinks are provided, at least 5 percent, but no <br />fewer than one, of each type provided in each <br />accessible room or space shall comply with Section <br />11B-606. §11B-212.3 <br />Exceptions: <br />a. Mop, service or scullery sinks shall not be <br />required to comply with Section 11B-212.3. <br />b. Scrub sinks, as defined in California Plumbing <br />Code Section 221.0, shall not be required to <br />comply with Section 11B-606. <br />MEN'S <br />GEOMETRIC <br />SYMBOL <br />9. Toilet and Bathing Facilities Geometric Symbols: Geometric <br />symbols at entrances to toilet and bathing rooms shall be <br />mounted at 58 inches minimum and 60 inches maximum above <br />the finish floor or ground surface measured from the centerline of <br />the symbol. Where a door is provided the symbol shall be <br />mounted within 1 inch of the vertical centerline of the door. <br />A. Men's Toilet and Bathing Facilities: A triangle symbol shall <br />be located at entrances to men's toilet and bathing facilities. <br />The triangle symbol shall be an equilateral triangle 1/4 inch <br />thick with edges 12 inches ong and a vertex pointing upward. <br />The color of the triangle symbol shall contrast with the color <br />of the door or surface on which the triangle symbol is <br />mounted, either light on a dark background or dark on a light <br />background. <br />B. Women's Toilet and Bathing Facilities: A circle symbol shall <br />be located at entrances to women's toilet and bathing <br />facilities. The circle symbol shall be 1/4 inch thick and 12 <br />inches in diameter. The color of the circle symbol shall <br />contrast with the color of the door or surface on which the <br />circle symbol is mounted, either light on a dark background <br />or dark on a light background. <br />Unisex Toilet and Bathing Facilities: A combined circle and triangle <br />symbol shall be located at entrances to unisex toilet and bathing <br />facilities. The combined circle and triangle symbol shall consist of a <br />circle symbol 1/4 inch thick and 12 inches in diameter with a 1/4 inch <br />thick equilateral triangle symbol superimposed on and geometrically <br />inscribed within the 12-inch diameter of the circle symbol. The <br />vertices of the triangle symbol shall be located 1/ 4 inch maximum <br />from the edge of the circle symbol with a vertex pointing upward. The <br />color of the triangle symbol shall contrast with the color of the circle <br />symbol, either light on a dark background or dark on a light <br />background. The color of the circle symbol shall contrast with the <br />color of the door or surface on which the combined circle and triangle <br />symbol is mounted, either light on a dark background or dark on a <br />light background. <br />WOMEN'S <br />GEOMETRIC <br />SYMBOL <br />WALL MOUNTED <br />TACTILE SIGN <br /> A <br />C <br />C <br />E <br />S <br />S <br />I <br />B <br />L <br />E <br /> <br />S <br />I <br />G <br />N <br /> <br />R <br />E <br />Q <br />. <br />MO <br />U <br />N <br />T <br />I <br />N <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br /> <br />P <br />E <br />R <br />TO <br /> <br />C <br />. <br />L <br />. <br /> <br />O <br />F <br /> <br />S <br />I <br />G <br />N <br />58 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />& <br /> <br /> <br />6 <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br />EQ EQ <br />9" MIN. <br />TOILET AND BATHING <br />FACILITY GEOMETRIC <br />SYMBOL <br />TOILET AND BATHING FACILITIES GEOMETRIC SYMBOLS <br />1. Geometric symbols at entrances to toilet and bathing rooms shall be <br />mounted at 58 inches minimum and 60 inches maximum above the <br />finish floor or ground surface measured from the centerline of the <br />symbol. Where a door is provided the symbol shall be mounted within 1 <br />inch of the vertical centerline of the door. <br />2. Men's Toilet and Bathing Facilities: A triangle symbol shall be located at <br />entrances to men's toilet and bathing facilities. The triangle symbol shall <br />be an equilateral triangle 1/4 inch thick with edges 12 inches long and a <br />vertex pointing upward. The color of the triangle symbol shall contrast <br />with the color of the door or surface on which the triangle symbol is <br />mounted, either light on a dark background or dark on a light <br />background. <br />3. Women's Toilet and Bathing Facilities: A circle symbol shall be located <br />at entrances to women's toilet and bathing facilities. The circle symbol <br />shall be 1/4 inch (6.4 mm) thick and 12 inches (305 mm) in diameter. <br />The color of the circle symbol shall contrast with the color of the door or <br />surface on which the circle symbol is mounted, either light on a dark <br />background or dark on a light background. <br />4. Unisex Toilet and Bathing Facilities: A combined circle and triangle <br />symbol shall be located at entrances to unisex toilet and bathing <br />facilities. The combined circle and triangle symbol shall consist of a <br />circle symbol 1/4 inch thick and 12 inches in diameter with a 1/4 inch ) <br />thick equilateral triangle symbol superimposed on and geometrically <br />inscribed within the 12-inch (305 mm) diameter of the circle symbol. The <br />vertices of the triangle symbol shall be located 1/ 4 inch (6.4 mm) <br />maximum from the edge of the circle symbol with a vertex pointing <br />upward. The color of the triangle symbol shall contrast with the color of <br />the circle symbol, either light on a dark background or dark on a light <br />background. The color of the circle symbol shall contrast with the color <br />of the door or surface on which the combined circle and triangle symbol <br />is mounted, either light on a dark background or dark on a light <br />background. <br />SEE ADDITION GENERAL SITE DETAILS FOR INFORMATION NOT <br />SHOWN HERE: <br />• ACCESSIBLE SIGN REQUIREMENTS <br />• DOOR AND GATE REQUIREMENTS <br />- <br />--- <br />- <br />--- <br />CLEAR FLOOR SPACE <br />VIEW FROM THE <br />EGRESS SIDE OF <br />THE DOOR <br />- <br />--- <br />- <br />--- <br />A. LEVEL CHANGES <br />B. THRESHOLD <br />C. TRANSITION BETWEEN FLOOR <br />FINISHES <br />MA <br />X <br />. <br />1/ <br />4 <br />" <br />2 <br />1 <br />1/ <br />2 <br />" <br /> <br />M <br />A <br />X <br />. <br />1/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />FLOOR FINISH <br />THRESHOLD <br />1/ <br />2 <br />" <br /> <br />M <br />A <br />X <br />. <br />FLOOR FINISH 1/4" MAX. BELOW <br />THRESHOLD TYP. COMPRESSED CARPET <br />1/4" MAX. BELOW THRESHOLD <br />MA <br />X <br />. <br />1/ <br />4 <br />" <br />FLOOR FINISH <br />FLOOR OR GROUND SURFACES <br />1. General: Floor and ground surfaces shall be stable, firm and slip resistant. <br />Exceptions: <br />a. Within animal containment areas, floor and ground surfaces shall not be <br />required to be stable, firm and slip resistant. <br />b. Areas of sport activity shall not be required to comply with Section <br />2. Carpet: Carpet or carpet tile shall be securely attached and shall have a <br />firm cushion, pad, or backing or no cushion or pad. Carpet or carpet tile <br />shall have a level loop, textured loop, level cut pile, level cut/uncut pile <br />texture. Pile height shall be 1/2 inch maximum. Exposed edges of carpet <br />shall be fastened to floor surfaces and shall have trim on the entire length of <br />the exposed edge. Carpet edge trim shall comply with Changes in Level <br />Requirements. <br />3. Openings: Openings in floor or ground surfaces shall not allow passage of a <br />sphere more than 1/2 inch diameter except as allowed in Platform to <br />Hoistway ClearancePlatform to Runway Clearance, Transportation Facility <br />Platform and Vehicle Floor Coordination Track Crossings Requirements. <br />Elongated openings shall be placed so that the long dimension is <br />perpendicular to the dominant direction of travel. <br />CHANGES IN LEVEL <br />1. General: Where changes in level are permitted in floor or ground surfaces, <br />they shall comply with this Section. Exceptions: <br />a. Animal containment areas shall not be required to comply with this <br />Section <br />b. Areas of sport activity shall not be required to comply with this Section <br />2. Vertical: Changes in level of 1/4 inch high maximum shall be permitted to be <br />vertical and without edge treatment. <br />3. Beveled: Changes in level between 1/4 inch high minimum and 1/2 inch <br />high maximum shall be beveled with a slope not steeper than 1:2. <br />4. Ramps: Changes in level greater than 1/2 inch high shall be ramped or a <br />blended transition. <br />AT SIDEWALKS <br />48" MIN. CLR. <br />UNREASONABLE <br />36"MIN. CLR. <br />HARDSHIP ONLY <br />AD <br />J <br />. <br /> <br />S <br />U <br />R <br />F <br />A <br />C <br />E <br /> <br />A <br />S <br /> <br />OC <br />C <br />U <br />R <br />S <br /> <br />P <br />E <br />R <br /> <br />P <br />L <br />A <br />N <br />SIDEWALK <br />SIDEWALK WIDTH AND HARDSHIP <br />EXCEPTION AT SIDEWALKS <br />ACCESSIBLE ROUTE <br />CLEAR WIDTH <br />CLR.WIDTH <br />36" MIN. <br />24 <br />" <br /> <br />M <br />A <br />X <br />. <br />24 <br />" <br /> <br />M <br />A <br />X <br />. <br />CLR. WIDTH <br />32" MIN. <br />CLR. WIDTH <br />36" MIN. <br />CLR. WIDTH <br />32" MIN. <br />42 <br />" <br /> <br />M <br />I <br />N <br />. <br />42 <br />" <br /> <br />M <br />I <br />N <br />. <br />LE <br />S <br />S <br /> <br />T <br />H <br />E <br />N <br /> <br />4 <br />8 <br />" <br />48" MIN. REQ'D. <br />36 <br />" <br /> <br />M <br />I <br />N <br />. <br />36 <br />" <br /> <br />M <br />I <br />N <br />. <br />LE <br />S <br />S <br /> <br />T <br />H <br />E <br />N <br /> <br />4 <br />8 <br />" <br />60" MIN. REQ'D. <br />ACCESSIBLE ROUTE <br />CLEAR WIDTH AT TURN <br />CU <br />R <br />B <br /> <br />T <br />Y <br />P <br />I <br />C <br />A <br />L <br />Accessible Routes <br />1. Components: Accessible routes shall consist of one or more of the following <br />components: walking surfaces with a running slope not steeper than 1:20, <br />doorways, ramps, curb ramps excluding the flared sides, elevators and <br />platform lifts. All components of an accessible route shall comply with the <br />applicable requirements of Accessible Routes. <br />2. Walking Surfaces: <br />a. Floor and ground surfaces shall be stable, firm and slip resistant <br />b. Carpet: Carpet or carpet tile shall be securely attached and shall have <br />a firm cushion, pad, or backing or no cushion or pad. Carpet or carpet <br />tile shall have a level loop, textured loop, level cut pile, level cut/uncut <br />pile texture. Pile height shall be 1/2 inch maximum. Exposed edges of <br />carpet shall be fastened to floor surfaces and shall have trim on the <br />entire length of the exposed edge. <br />c. Openings in floor or ground surfaces shall not allow passage of a <br />sphere more than 1/2 inch diameter. Elongated openings shall be <br />placed so that the long dimension is perpendicular to the dominant <br />direction of travel. <br />3. Slope: The running slope of walking surfaces shall not be steeper than 1:20. <br />The cross slope of walking surfaces shall not be steeper than 1:48. <br />Exception: The running slope of sidewalks shall not exceed the general <br />grade established for the adjacent street or highway. <br />4. Clearances: Walking surfaces shall provide clearances complying with Clear <br />Width Requirement <br />Exception: Within employee work areas, clearances on common use <br />circulation paths shall be permitted to be decreased by work area <br />equipment provided that the decrease is essential to the function of the <br />work being performed. <br />5. Clear Width: Except as provided in Clear Width at Turn and Passing spaces <br />the clear width of walking surfaces shall be 36 inches minimum. <br />Exceptions: The clear width shall be permitted to be reduced to 32 inches <br />minimum for a length of 24 inches maximum provided that reduced width <br />segments are separated by segments that are 48 inches long minimum and <br />36 inches wide minimum. <br />a. The clear width for walking surfaces in corridors serving an occupant <br />load of 10 or more shall be 44 inches (1118 mm) minimum. <br />b. The clear width for sidewalks and walks shall be 48 inches (1219 mm) <br />minimum. When, because of right-of-way restrictions, natural barriers <br />or other existing conditions, the enforcing agency determines that <br />compliance with the 48-inch (1219 mm) clear sidewalk width would <br />create an unreasonable hardship, the clear width may be reduced to 36 <br />inches (914 mm). <br />c. The clear width for aisles shall be 36 inches (914 mm) minimum if <br />serving elements on only one side, and 44 inches (1118 mm) minimum <br />if serving elements on both sides. <br />d. The clear width for accessible routes to accessible toilet compartments <br />shall be 44 inches (1118 mm) except for door-opening widths and door <br />swings. <br />6. Clear Width at Turn: Where the accessible route makes a <br />180 degree turn around an element which is less than 48 <br />inches wide, clear width shall be 42 inches minimum <br />approaching the turn, 48 inches minimum at the turn and 42 <br />inches minimum leaving the turn. <br />Exception: Where the clear width at the turn is 60 inches <br />minimum compliance with Clear Width at Turn Requirements <br />shall not be required. <br />7. Passing Spaces: An accessible route with a clear width less <br />than 60 inches shall provide passing spaces at intervals of <br />200 feet maximum. Passing spaces shall be either: a space <br />60 inches minimum by 60 inches minimum; or, an <br />intersection of two walking surfaces providing a T-shaped <br />space where the base and arms of the T-shaped space <br />extend 48 inches minimum beyond the intersection. <br />8. Handrails: Where handrails are provided along walking <br />surfaces with running slopes not steeper than 1:20 they shall <br />comply with Handrail Requirements. <br />9. Continuous Gradient: All walks with continuous gradients <br />shall have resting areas, 60 inches in length, at intervals of <br />400 feet maximum. The resting area shall be at least as wide <br />as the walk. The slope of the resting area in all directions <br />shall be 1:48 maximum. <br />10. Changes in Level: <br />a. Changes in level of 1/4 inch high maximum shall be <br />permitted to be vertical and without edge treatment. <br />b. Changes in level between 1/4 inch high minimum and <br />1/2 inch high maximum shall be beveled with a slope not <br />steeper than 1:2. <br />c. Abrupt changes in level exceeding 4 inches in a vertical <br />dimension between walks, sidewalks or other pedestrian <br />ways and adjacent surfaces or features shall be <br />identified by warning curbs at least 6 inches in height <br />above the walk or sidewalk surface. <br />Turning Space <br />1. Floor or Ground Surfaces: Changes in level, slopes exceeding 1:48, <br />and detectable warnings shall not be permitted. <br />2. Size <br />a. Circular Space: The turning space shall be a space of 60 inches <br />diameter minimum. The space shall be permitted to include knee <br />and toe clearance. <br />b. T-Shaped Space: The turning space shall be a T-shaped space <br />within a 60 inch square min. with arms and base 36 inches wide <br />minimum. Each arm of the T shall be clear of obstructions 12 <br />inches min. in each direction and the base shall be clear of <br />obstructions 24 inches min. The space shall be permitted to <br />include knee and toe clearance only at the end of either the base <br />or one arm. <br />3. Door Swing: Doors shall be permitted to swing into turning spaces. <br />Clear Floor or Ground Space <br />1. Floor or Ground Surfaces: Changes in level, slopes exceeding 1:48, <br />and detectable warnings shall not be permitted. <br />2. Size: The clear floor or ground space shall be 30 inches min. by 48 <br />inches minimum. <br />3. Knee and Toe Clearance: Unless otherwise specified, clear floor or <br />ground space shall be permitted to include knee and toe clearance. <br />4. Position: Unless otherwise specified, clear floor or ground space shall <br />be positioned for either forward or parallel approach to an element. <br />5. Approach: One full unobstructed side of the clear floor or ground space <br />shall adjoin an accessible route or adjoin another clear floor or ground <br />space. Clear floor or ground space may overlap an accessible route, <br />unless specifically prohibited elsewhere in this chapter. <br />6. Maneuvering Clearance: Where a clear floor or ground space is located <br />in an alcove or otherwise confined on all or part of three sides, <br />additional maneuvering clearance shall be provided in accordance with: <br />a. Forward Approach: Alcoves shall be 36 inches wide min. where <br />the depth exceeds 24 inches . <br />b. Parallel Approach: Alcoves shall be 60 inches wide min. where the <br />depth exceeds 15 inches . <br />5'-0" ø <br />5'-0" <br />24 <br />" <br />36 <br />" <br />12"36"12" <br />Base <br />Ar <br />m <br />Ar <br />m <br />SHADED AREA MAY EXTEND <br />UNDER ELEMENTS. MIN. <br />CLEARANCE IS 27 INCH <br />ABOVE THE FINISH FLOOR <br />ALCOVE - <br />PARALLELAPPROACH <br />60" <br />30 <br />" <br />15 <br />" <br /> <br />O <br />R <br /> <br />G <br />R <br />E <br />A <br />T <br />E <br />R <br />ALCOVE, FORWARD APPROACH <br />36 <br />" <br />48" <br />THEN 24" <br />MORE <br />30 <br />" <br />48" <br />CLEAR FLOOR SPACE FRONT <br />APPROACH <br />30 <br />" <br />48" <br />CLEAR FLOOR SPACE - <br />PARALLEL APPROACH <br />731 South Highway 101, Suite 1M, <br />Solana Beach, CA 92075 <br />(714) 639-9860 <br />ry-aoarchitects.com <br />Plan Check Number: <br />Project Number: <br />20 <br />2 <br />2 <br /> <br />R <br />Y <br />+ <br />A <br />O <br />, <br /> <br />L <br />L <br />P <br />Th <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />a <br />r <br />e <br /> <br />c <br />o <br />p <br />y <br />r <br />i <br />g <br />h <br />t <br /> <br />p <br />r <br />o <br />t <br />e <br />c <br />t <br />e <br />d <br />. <br /> <br /> <br />U <br />n <br />d <br />e <br />r <br /> <br />s <br />u <br />c <br />h <br /> <br />p <br />r <br />ot <br />e <br />c <br />t <br />i <br />o <br />n <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />i <br />z <br />e <br />d <br /> <br />u <br />s <br />e <br /> <br />i <br />s <br /> <br />n <br />o <br />t <br /> <br />p <br />e <br />r <br />m <br />i <br />t <br />t <br />e <br />d <br />. <br /> <br />T <br />h <br />e <br />s <br />e <br /> <br />p <br />la <br />n <br />s <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />o <br />r <br /> <br />u <br />s <br />e <br />d <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />b <br />y <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br /> <br />O <br />r <br />a <br />n <br />g <br />e <br />. <br />c <br />SEAL <br />CONSULTANT <br />Dr <br />a <br />w <br />i <br />n <br />g <br /> <br />F <br />i <br />l <br />e <br /> <br />N <br />a <br />m <br />e <br />: <br />Sh <br />e <br />e <br />t <br /> <br />P <br />l <br />o <br />t <br />t <br />e <br />d <br />: <br />S H E E T <br />-- <br />C: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />r <br />o <br />b <br />e <br />r <br />t <br />s <br />\ <br />O <br />n <br />e <br />D <br />r <br />i <br />v <br />e <br /> <br />- <br /> <br />A <br />O <br />\ <br />D <br />o <br />c <br />u <br />m <br />e <br />n <br />t <br />s <br />\ <br />2 <br />0 <br />2 <br />3 <br />- <br />0 <br />6 <br />4 <br />6 <br /> <br />SC <br />E <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />B <br />l <br />d <br />g <br /> <br />C <br /> <br />S <br />e <br />i <br />s <br />m <br />i <br />c <br /> <br />R <br />e <br />t <br />r <br />o <br />f <br />i <br />t <br />_ <br />a <br />o <br />_ <br />c <br />o <br />m <br />m <br />_ <br />r <br />o <br />b <br />e <br />r <br />ts <br />. <br />r <br />v <br />t <br />6/ <br />1 <br />1 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />5 <br />: <br />4 <br />0 <br />: <br />1 <br />2 <br /> <br />P <br />M <br />GE <br />N <br />E <br />R <br />A <br />L <br /> <br />P <br />L <br />U <br />M <br />B <br />I <br />N <br />G <br /> <br />F <br />I <br />X <br />T <br />U <br />R <br />E <br />, <br />RE <br />S <br />T <br />R <br />O <br />O <br />M <br />, <br /> <br />& <br /> <br />K <br />I <br />T <br />C <br />H <br />E <br />N <br />E <br />T <br />T <br />E <br />RE <br />Q <br />U <br />I <br />R <br />E <br />M <br />E <br />N <br />T <br />S <br />2023-0646 <br />8631 RUSH STREET <br />ROSEMEAD, CA 91770 <br />626-302-3687 <br />SOUTHERN CALIFORNIA EDISON <br />SC <br />E <br /> <br />- <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />B <br />l <br />d <br />g <br /> <br />C <br /> <br />V <br />o <br />l <br />u <br />n <br />t <br />a <br />r <br />y <br />Se <br />i <br />s <br />m <br />i <br />c <br /> <br />R <br />e <br />t <br />r <br />o <br />f <br />i <br />t <br />13 <br />2 <br />7 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />G <br />R <br />A <br />N <br />D <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />101119260 <br />T3.0 <br />2024-01-24 Issue for Plan Check <br />2024-02-21 Issue for City Planning <br />2024-06-11 Re-Issue for Plan Check <br />Scale: <br />1/2" = 1'-0"2TOILET ROOMS / TOILET COMPARTMENTS / ACCESSORY MOUNTING HEIGHTS / URINALS / LAVS & SINKS (11B-603, 11B-604, 11B-605, & 11B-606) <br />Scale: <br />1 1/2" = 1'-0"1ACCESSIBLE SIGN REQUIREMENTS 11B-703.4 <br />Scale: <br />3/8" = 1'-0"20TACTILE RESTROOM DOOR (11B-703)Scale: <br />6" = 1'-0"25GROUND SURFACE LEVEL CHANGES 11B 302-303 <br />Scale: <br />1/4" = 1'-0"18ACCESSIBLE ROUTE (11B-402 11B-403 ) <br />Scale: <br />1/4" = 1'-0"24FLOOR & TURNING SPACE (11B-304 11B-305) <br />REN. 4/30/25 <br />No. C-11043 <br />RICHARD S.YEN <br />STATE OF CALIFORNIA <br />REGISTERED ARCHITEC <br />T <br />2024-06-11 <br />1327 S Grand Ave <br />12/12/2024