My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1327 S Grand Ave - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Grand Ave
>
1327 S Grand Ave
>
1327 S Grand Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:37:11 AM
Creation date
6/5/2025 7:36:53 AM
Metadata
Fields
Template:
Plan
Permit Number
101119260
Full Address
1327 S Grand Ave
Jump to thumbnail
< previous set
next set >
Rectangle
ID:
1
Creator:
Import Agent
Created:
6/5/2025 7:36 AM
Modified:
6/4/2025 12:16 PM
ID:
2
Creator:
Import Agent
Created:
6/5/2025 7:36 AM
Modified:
6/4/2025 12:16 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
6 <br />Lo <br />a <br />d <br /> <br />T <br />a <br />b <br />l <br />e <br />s <br />RED-L™ TRUSS ALLOWABLE UNIFORM LOAD TABLE (PLF) / PARALLEL CHORD <br />General Notes <br />· Values shown demonstrate maximum allowable load capacities based on <br />the following assumptions: <br /> – Simple span, uniformly loaded conditions, with provisions for positive <br />drainage (¼ :12 slope, minimum) in roof applications. <br /> – Span indicates distance from inside face to inside face of bearing. <br /> – Top chord no-notch bearing clips with 1¾" bearing. Higher values may be <br />possible with other types of bearing clips. <br />Trusses delivered to the jobsite are custom manufactured to resist only project specifi c application loads provided by the design professional. Actual trusses may not <br />be able to resist the maximum loads shown in the tables above. For questions regarding actual truss capacity contact your RedBuilt technical representative. <br />· Straight line interpolations may be made between depths and spans. <br />· Values in shaded areas may be increased 7% for repetitive-member use. <br />· Bold italic values are controlled by minimum concentrated load analysis <br />of 2,000 lbs. Higher loads are possible where minimum concentrated <br />load analysis is not required by code. Contact your RedBuilt technical <br />representative for assistance. <br />Span <br />Depth <br />14" 16" 18"20" 22" 24"26" <br />100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL <br />100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL <br />14'292 341 329 383 376 400 380 412 340 390 309 360 299 356 <br />208 370 254 395 323 412 367 429 422 385 386 <br />16' 265 306 306 340 341 361 342 366 335 369 338 351 305 350 <br />143 311 190 361 232 370 270 376 318 380 375 380 <br />18' 215 250 200 286 232 319 309 328 301 332 315 334 301 332 <br />110 271 145 306 180 329 215 333 250 340 278 336 339 <br />20' 184 208 171 245 184 275 203 295 227 297 283 299 291 297 <br />84 229 109 260 139 292 167 298 197 303 226 305 255 310 <br />22' 158 177 142 204 160 233 177 260 200 272 220 271 270 275 <br />66 192 84 217 110 252 134 269 155 271 184 276 196 280 <br />24' 133 150 133 174 143 199 157 223 173 239 185 247 202 249 <br />52 164 68 189 88 215 106 241 126 251 146 252 167 254 <br />26' 106 131 113 152 129 173 136 189 151 213 166 225 176 230 <br />43 137 55 160 70 188 86 210 103 222 123 231 140 236 <br />28' 86 111 109 129 118 148 125 163 136 181 151 199 163 212 <br />34 111 45 142 57 158 69 181 86 200 102 214 117 213 <br />30' 91 93 114 108 128 121 145 127 158 140 173 150 192 <br />91 37 121 47 140 58 155 69 175 81 192 93 202 <br />32' 76 76 100 95 113 107 125 118 142 127 155 136 169 <br />76 31 102 39 124 48 140 58 155 68 170 78 184 <br />34' 63 85 83 101 99 114 105 126 120 138 127 151 <br />64 85 33 110 41 124 49 136 58 150 67 164 <br />36' 55 73 87 86 98 97 108 107 117 114 129 <br />55 73 94 35 102 42 117 50 128 58 140 <br />38' 47 62 78 75 86 85 97 92 105 97 116 <br />47 62 80 30 91 36 104 43 115 50 126 <br />40' 40 53 69 79 79 87 81 96 94 103 <br />41 53 69 86 31 94 37 100 43 114 <br />42' 35 46 60 72 78 79 87 85 95 <br />35 47 60 73 82 32 92 38 103 <br />44'31 40 50 65 70 80 77 82 <br />31 39 52 66 74 85 33 94 <br />46'36 45 58 66 73 79 <br />36 45 58 69 79 86 <br />48'32 40 52 61 67 73 <br />32 41 52 62 68 79 <br />50'36 45 54 62 65 <br />36 45 56 62 73 <br />52'32 40 49 57 61 <br />33 39 50 59 63 <br />54'35 43 52 55 <br />36 43 53 62 <br />56'32 40 48 54 <br />33 40 47 56 <br />58'36 43 48 <br />36 42 49 <br />60'33 39 46 <br />33 39 44 <br />· See page 5 for available depths and profiles. For depths and profiles not shown, contact your RedBuilt technical representative for assistance. <br />· Red numbers refer to 115% Total Load (TL). <br /> SEE PAGE 4 FOR ECONOMICAL TRUSS DESIGN <br />General Notes continued on page 7 <br />Page 42 of 43 <br />1327 S Grand Ave <br />12/12/2024
The URL can be used to link to this page
Your browser does not support the video tag.