Laserfiche WebLink
7 <br />Lo <br />a <br />d <br /> <br />T <br />a <br />b <br />l <br />e <br />s <br />Span <br />Depth <br />28"30"32"34"36"38"40" <br />100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL <br />100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL <br />14'295 353 294 324 290 308 277 309 262 300 264 304 243 280 <br />374 367 365 336 308 318 301 <br />16' 303 347 266 306 264 288 265 305 255 271 256 273 240 275 <br />380 359 331 332 288 282 283 <br />18' 263 341 266 317 261 279 261 287 237 271 239 250 231 263 <br />339 345 308 314 297 276 303 <br />20' 270 303 285 298 239 287 242 281 221 259 219 264 221 250 <br />250 311 267 309 307 327 284 289 274 <br />22' 259 279 257 279 241 266 233 259 228 258 224 253 223 236 <br />208 282 232 282 279 281 281 278 259 <br />24' 219 255 252 255 242 259 237 258 227 259 218 246 213 246 <br />185 257 190 260 211 263 228 264 263 264 252 <br />26' 195 231 205 233 233 238 227 237 221 238 232 228 212 230 <br />158 235 175 242 177 239 198 242 214 243 231 241 237 <br />28' 175 216 214 215 216 220 216 218 218 222 198 222 210 215 <br />132 220 137 221 152 221 169 224 184 224 195 221 218 <br />30' 159 201 167 204 200 205 194 208 204 208 201 208 204 205 <br />111 205 124 204 133 207 145 208 159 207 174 205 191 202 <br />32' 149 184 158 191 170 191 181 191 190 195 192 192 189 191 <br />89 191 99 191 113 193 123 192 137 194 152 190 163 191 <br />34' 138 162 147 174 157 181 165 189 169 182 179 179 180 179 <br />77 176 87 177 95 174 108 189 119 181 130 182 144 180 <br />36' 123 138 132 146 140 160 151 166 161 170 169 170 170 166 <br />66 151 75 162 84 171 94 178 103 170 113 169 125 166 <br />38' 113 116 115 134 127 144 136 152 144 161 152 161 159 157 <br />57 136 64 147 72 157 82 161 91 161 99 161 109 154 <br />40' 102 110 110 122 117 130 125 139 129 147 140 153 148 151 <br />49 122 55 132 63 142 71 150 79 151 87 151 95 149 <br />42' 92 102 99 108 107 114 114 125 121 129 128 141 133 142 <br />43 112 49 120 55 127 62 136 69 145 77 145 83 143 <br />44'78 92 91 96 96 107 103 114 109 121 116 129 121 131 <br />38 97 43 109 49 117 55 125 61 133 68 137 75 134 <br />46'77 84 82 92 89 98 95 105 101 112 105 118 112 120 <br />33 93 38 100 43 106 48 114 54 121 60 128 66 127 <br />48'70 79 73 85 82 91 87 97 91 102 98 108 103 113 <br />30 86 34 92 38 98 43 105 48 111 54 118 59 122 <br />50'72 69 78 71 83 80 89 85 94 90 100 95 105 <br />79 30 85 34 86 39 96 43 103 48 108 52 115 <br />52'66 72 70 77 74 82 79 87 83 92 88 97 <br />73 78 31 84 34 89 39 95 43 100 48 106 <br />54'62 65 67 69 76 73 81 77 86 82 90 <br />68 71 78 31 83 34 88 38 93 42 94 <br />56'57 62 69 72 68 78 72 81 76 86 <br />65 68 71 78 31 83 35 88 38 93 <br />58'55 57 62 68 73 67 77 71 82 <br />58 62 68 75 79 31 83 35 88 <br />60'52 55 60 64 68 71 66 75 <br />50 61 65 70 74 78 32 83 <br />SEE PAGE 4 FOR ECONOMICAL TRUSS DESIGN <br />To size fl oor trusses: <br />Check both total load (100% TL) and live load (100% LL). When live load is not <br />shown, total load will control. Total load values limit defl ection to L/240. Live <br />load values are based on the Commercial Floor Defl ection Limit shown on <br />page 35, and assume a nailed fl oor system. Live load (100% LL) values may <br />be increased with a glue-nailed fl oor system; contact your RedBuilt technical <br />representative for assistance. <br />Trusses delivered to the jobsite are custom manufactured to resist only project specifi c application loads provided by the design professional. Actual trusses may not <br />be able to resist the maximum loads shown in the tables above. For questions regarding actual truss capacity contact your RedBuilt technical representative. <br />To size roof trusses: <br />Check the appropriate snow load area (115% TL) or non-snow load area <br />(125% TL) value to determine the maximum allowable total load. Total load <br />(115% TL and 125% TL) values limit truss defl ection to L/180. <br />Consult local codes to verify defl ection limits required for specifi c applications. <br />· See page 5 for available depths and profiles. For depths and profiles not shown, contact your RedBuilt technical representative for assistance. <br />· Red numbers refer to 115% Total Load (TL). <br />General Notes continued from page 6 <br />RED-L™ TRUSS ALLOWABLE UNIFORM LOAD TABLE (PLF) / PARALLEL CHORD <br />Continued from page 6 <br />Page 43 of 43 <br />1327 S Grand Ave <br />12/12/2024