My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FLOOD ZONE - 718 S Flintridge Dr Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Flintridge Dr
>
718 S Flintridge Dr Unit# 2
>
FLOOD ZONE - 718 S Flintridge Dr Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 7:18:28 AM
Creation date
6/6/2025 7:18:19 AM
Metadata
Fields
Template:
Plan
Permit Number
101119235
Full Address
718 S Flintridge Dr Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
TMC ENGINEERS INC. <br />Geotechnical, Structural and Civil Engineering <br />Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com <br /> <br />Page 11 <br /> <br /> <br />7.2 Shallow Foundation Design <br />7.2.1 Allowable foundation and Lateral Pressure: <br />Based on our field investigation and laboratory testing results. In accordance with Section <br />1806.2 of the 2022 California Building Code. It is recommended that the following <br />parameters should be considered in the foundation design and construction: <br /> <br />For conservative, the lowest values in table 1806.2, 2022 CBC Code, allowable bearing <br />value of 1500 pounds per square foot. <br /> <br />7.2.2 Settlement <br />Distress to the existing house due to settlement of the underlying soil was not observed. <br />Settlement of soils underlying is not a concerned for the proposed development. <br />Under construction, differential settlement between adjacent columns is not anticipated to <br />exceed 1/4 inch for the adjacent column spaced at a distance of about 40 feet. <br /> <br />7.2.3 Lateral Pressures <br />Passive earth pressure may be computed as an equivalent fluid pressure of 150 pounds per <br />cubic foot, with a maximum earth pressure of 1500 pounds per square foot. An allowable <br />coefficient of friction between soil and concrete of 0.3 may be used with the dead load forces. <br />When combining passive pressure and frictional resistance, the passive pressure component <br />should be reduced by one-third. <br /> <br />FLOOD ZONE - 718 S <br />Flintridge Dr Unit# 23/26/2025
The URL can be used to link to this page
Your browser does not support the video tag.