My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FLOOD ZONE - 718 S Flintridge Dr Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Flintridge Dr
>
718 S Flintridge Dr Unit# 2
>
FLOOD ZONE - 718 S Flintridge Dr Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 7:18:28 AM
Creation date
6/6/2025 7:18:19 AM
Metadata
Fields
Template:
Plan
Permit Number
101119235
Full Address
718 S Flintridge Dr Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
TMC ENGINEERS INC. <br />Geotechnical, Structural and Civil Engineering <br />Add: 9542 Pacific Ave, Anaheim, CA92804. Phone: 714-829-5053; Email: Tienchu.pe@gmail.com <br /> <br />Page 13 <br /> <br /> <br />7.3 Temporary Trench Excavation and Backfill <br />All trench excavations should conform to CAL-OSHA and local safety codes. All utilities <br />trench backfill should be brought to near optimum moisture content and then compacted to <br />obtain a minimum relative compaction of 90 percent of ASTM D-1557-07. <br /> <br />7.4 Nonstructural concrete Flatwork: Sidewalk and Private Driveway <br /> 4 inches (sidewalk) and 5 inch (driveway) minimum thickness reinforce concrete with # 3 at <br />24” on center. Crack control with saw cut or deep tool joint to a minimum of 1/3 the concrete <br />thickness, maximum joint spacing is 5 feet (sidewalk) and 10 feet or quarter cut (driveway) <br />whichever closer. <br />8.0 CORROSION POTENTIAL <br />Sulfate attack was not observed for the existing buildings in this subjected area. Type V <br />cement with concrete strength 3000 psi is recommended to use, Water-Cement ratio=0.5. <br />Other requirement from government agencies, if any, can be followed. <br />It is recommended that the subsurface soils can be corrosive to buried metal pipe. It is <br />recommended that any underground steel utilities be blasted and given protective coating. <br />Should additional protective measures be warranted, a corrosion specialist should be <br />consulted. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />FLOOD ZONE - 718 S <br />Flintridge Dr Unit# 23/26/2025
The URL can be used to link to this page
Your browser does not support the video tag.