CONTRACTOR <br />SHEET DESCRIPTION: <br />NOTES <br />DRAWN DATE 27.06.2024 <br />DRAWN BY EMMANUEL <br />REVIEWED BY ---- <br />REVISIONS <br />REV DESCRIPTION DATE <br />SHEET INDEX <br />UTILITY : SCE <br />PROJECT INFORMATION <br />AHJ : SANTA ANA <br />ADDRESS : 2010 E WARNER AVE, <br />SANTA ANA, CA <br />NAME : WARNER REDHILL <br />APN : 430-222-07/430-222-16 <br />SYSTEM INFORMATION: <br />(58)LITEON <br />CHARGING STATIONS <br />PROJECT INFORMATION: <br />CHARGIE TO DESIGN AND <br />INSTALL THE CHARGING <br />SYSTEM. <br />EV-11 <br />SINGLE LINE NOTES: <br />1.ALL CONDUCTORS SHALL BE COPPER AS FOLLOWS: <br />#12AWG AND SMALLER - SOLID, TW <br />#10AWG AND LARGER - STRANDED, THHN OR THWN <br />ALL CONDUCTORS SIZES ARE BASED ON 75°C TEMPERATURE <br />RATINS (NEC.2014 TABLE 310.16) <br />2.ALL NEW CIRCUIT BREAKERS, FUSIBLE SWITCHES IN MAIN <br />SWITCHBOARD OR PANEL BOARDS SHALL BE SERIES RATED TO <br />MATCH EXISTING AIC RATING OR APPROVED EQUAL OR 65kAIC, <br />UNLESS NOTED OTHERWISE. <br />3.MOTOR CIRCUIT PROTECTORS SHALL NOT BE A PART OF SERIES <br />COMBINATION INTERRUPTING RATINGS. <br />4.SERIES COMBINATION AIC RATINGS SHALL NOT BE USED WHEN <br />THE SECONDARY EQUIPMENT IN THE SERIES IS SUBJECT TO A <br />TOTAL CONNECTED FULL LOAD MOTOR CURRENT OF MORE THAN <br />1% OF ITS AIC RATINGS. <br />5.EQUIPMENT ENCLOSURES SHALL BE CLEARLY MARKED <br />"CAUTION-SERIES RATED SYSTEM - 65KAMPS AVAILABLE, <br />IDENTIFIED REPLACEMENT COMPONENTS REQUIRED". IN <br />COMPLIANCE WITH 2016 CEC (NEC 2014) SECTION 110-22 END USE <br />EQUIPMENT SHALL ALSO BE MARKED WITH THE HIGHER SERIES <br />COMBINATION INTERRUPTING RATINGS AS PER 2016 CEC SECTION <br />240-89(C). NO EXCEPTION. <br />6.FUSES SHALL BE PROVIDED WITH REJECTION TYPE FUSE <br />HOLDERS. <br />7.ELECTRICAL EQUIPMENT SHALL BE LISTED BY THE CITY, WHERE <br />THE PROJECT IS LOCATED, RECOGNIZED ELECTRICAL TESTING <br />LABORATORY OR APPROVED BY THE DEPARTMENT. <br />8.NO PIPING, NO DUCTS OF EQUIPMENT FOREIGN TO ELECTRICAL <br />EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE <br />DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. <br />9.ALL ITEMS SHOWN ARE EXISTING U.O.N. <br />10.ALL FEEDER LENGTHS SHOWN ARE FOR VOLTAGE DROP AND <br />SHORT CIRCUIT CALCULATIONS ONLY. <br />11.MAXIMUM AVAILABLE FAULT CURRENT AT MAIN SERVICE <br />ENTRANCE IS ASSUMED TO BE 42KAIC U.O.N. <br />12.IN MAIN SWITCHBOARD BUS BRACING AND A.I.C. RATINGS OF ALL <br />DEVICES SHALL BE 42,000 MIN. U.O.N. <br />13.CIRCUIT BREAKERS IN ALL MAIN SWITCHBOARDS AND PANELS <br />SHALL BE FROM THE SAME MANUFACTURER AND ENTIRE SYSTEM. <br />14.ALL REMAINING SPACES IN MAIN SWITCHBOARDS AND PANELS <br />SHALL BE BUSSED. <br />15.ALL SUBPANELS SHALL BE RATED 42,000 AIC U.O.N. <br />16.SUBMIT SHOP DRAWINGS OF MAIN SWITCHBOARD TO SERVING <br />UTILITY COMPANY AND OBTAIN THERE APPROVAL PRIOR TO <br />RELEASING SHOP DRAWINGS TO MANUFACTURER. VERIFY TYPE <br />OF REQUIRED METER SOCKETS (IF NECESSARY). <br />17.ALL SECTIONS OF MAIN SWITCHBOARD SHALL HAVE THE <br />HORIZONTAL AND VERTICAL BUSS BARS RATED FOR THE AMPERE <br />RATING SHOWN ON SINGLE LINE DIAGRAMS. REDUCTION OF <br />AMPERE RATING OF BUSS BARS THROUGHOUT THE SECTIONS OF <br />MAIN SWITCHBOARDS IS NOT ACCEPTABLE. <br />18.NOTIFY SWITCHBOARD PANEL BOARDS MANUFACTURERS OF <br />FEEDER TERMINATIONS (TOP OR BOTTOM) PRIOR TO SUBMITTING <br />SHOP DRAWINGS. <br />19.PROVIDE A METALLIC CARD HOLDER ON INSIDE OF DOOR OF EACH <br />PANEL BOARD FOR INDEX CARD AND ACCURATE TYPEWRITTEN <br />PANEL SCHEDULE BE PUT BEHIND HEAVY PLASTIC COVER INTO <br />EACH PANEL. ROOM NUMBERS SHALL NOT BE THE ONES ON THE <br />PLANS BUT THE ONES DESIGNATED BY THE ARCHITECT AND/OR <br />OWNER. <br />20.PROVIDE TWO (2) KEYS WITH EACH PANEL BOARD. ALL PANELS <br />BOARDS LOCKS SHALL BE KEYED ALIKE. <br />21.WHERE TWO OF THREE POLE BREAKERS OCCUR IN LIGHTING <br />PANELS THE MULTI-POLE BREAKERS SHALL HAVE A COMMON TRIP <br />"QUICKLAG" TYPE UNITS. SINGLE POLE BREAKERS WITH TIE-BAR <br />BETWEEN HANDLES WILL NOT BE ACCEPTABLE. <br />22.PROVIDE BLACK ON WHITE LAMINATED PLASTIC NAMEPLATE <br />ENGRAVED IN MIN 1 <br />4" HIGH LETTERS, ATTACHED NAMEPLATES TO <br />EQUIPMENT, SWITCHBOARD(S), DISTRIBUTION BOARD(S), PANEL <br />BOARDS AND DISCONNECTS ETC, WITH RIVETS, BOLTS, OR SHEET <br />METAL SCREWS. CEMENT ATTACHMENTS ARE NOT ACCEPTABLE. <br />23.TIME SWITCHES, CONTACTORS, RELAYS, ETCH SHOWN TO BE <br />FURNISHED WITH PANEL BOARDS SHALL BE LOCATED IN <br />BARRIERED COMPARTMENTS BEHIND SEPARATE DOORS, MAINTAIN <br />2" OF SOLD TRIP BETWEEN DOORS. IF NECESSARY, INSTALL <br />SWITCHES, CONTACTORS, RELAYS, ETCH IN SEPARATE <br />WEATHERPROOF CABINETS WITH HINGED LOCKABLE DOORS. <br />PROVIDE SCREW-ON TYPE NAMEPLATES, FULLY COMPLY WITH <br />LATEST HANDICAP STANDARDS. <br /> IMPORTANT BID NOTES: <br />1.DUE TO THE SMALL SCALE OF DRAWINGS, IT IS NOT ALWAYS <br />POSSIBLE TO SHOW ALL DEVICES WHICH MAYBE REQUIRED. <br />CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ALL EXISTING <br />CONDITIONS BEFORE SUBMITTING HIS/HER BID. NO ADDITIONAL <br />COMPENSATION WILL BE MADE FOR EXTRA DUE TO CONTRACTOR'S <br />FAILURE TO VISIT THE JOB SITE AND/OR FAILURE TO DETERMINE ALL <br />EXISTING CONDITIONS BEFORE SUBMITTING HIS/HER BID. <br />2.REFER TO COMPLETE ARCHITECTURAL AND ELECTRICAL DRAWINGS <br />FOR ADDITIONAL NOTES, SPECIFICATIONS, DETAILS, CONTROLS, <br />ETC. REPORT TO ARCHITECTURE'S CLARIFICATION IN BASE BID. THIS <br />REQUIREMENT WILL BE STRICTLY ENFORCED. NO CHANGE ORDERS <br />WILL BE ALLOWED IF THE CONTRACTOR FAILS TO PERFORM THIS <br />FUNCTION. <br />3.CONTRACTOR SHALL REVIEW, VERIFY AND MEET ALL SPECIFICATION <br />AND STANDARD AS DENOTED IN DIVISION 26 SPEC BOOK. <br /> DEMOLITION NOTES: <br />1.THE DRAWINGS SHOW THE WORK TO BE IN PLACE AT THE <br />COMPLETION OF INSTALLATION. MAKE NECESSARY ALTERATIONS <br />TO COORDINATE AND CONNECT THE EXISTING ELECTRICAL WORK <br />WITH THE NEW SUCH THAT, WHEN THE WORK IS DONE, THE ENTIRE <br />ELECTRICAL INSTALLATION, EXISTING AND NEW, IS IN COMPLETE <br />OPERATING CONDITION. <br />2.UNLESS SPECIFICALLY NOTED ON THE CONTRARY, ALL EXISTING <br />LIGHTING FIXTURES, SWITCHES, CONTROLS AND OTHER MATERIALS <br />OR EQUIPMENTS WHICH ARE REPLACED BY NEW AND ARE NOT <br />INDICATED TO BE REUSED SHALL BE RETURNED TO THE OWNER OR <br />BE DISPOSED AS DIRECTED BY THE OWNER. <br />3.EXISTING MATERIAL TO REMAIN UPON COMPLETION IS INDICATED <br />ON DRAWINGS AS EXISTING, FEEDERS (CONDUIT AND WIRES) ARE <br />EXISTING TO THEIR RESPECTIVE SOURCE. ALTHOUGH NOT <br />INDICATED ON THE DRAWINGS. TEMPORARY REMOVAL OR <br />RE-ROUTE CONDUITS AND REPLACE EXISTING WIRES WITH NEW <br />DURING CONSTRUCTION WORK MAYBE REQUIRED. <br />4.PROVIDE AND INSTALL NEW COVER PLATES FOR ALL REMOVED <br />OUTLETS, SWITCHES, LIGHT FIXTURES, AND OTHER ELECTRICAL <br />DEVICES WHEN THE OUTLET BOX IS TO REMAIN. <br />5.REMOVE ALL EXISTING ABANDONED FEEDERS (CONDUITS AND <br />WIRES) BACK TO PANEL BOARDS. LABEL NEW PANEL DIRECTORY AS <br />"SPARE". <br />6.MAINTAIN CONTINUITY OF ALL ELECTRICAL SYSTEMS, EQUIPMENT, <br />ETC., FED BY ABANDONED OUTLET. THEY SHOULD BE IN OPERATION <br />AFTER THE WORK IS DONE. MAINTAINING CONTINUITY SHALL <br />CONSIST OF RE-ROUTING OF CONDUIT AND WIRING, AS REQUIRED <br />TO SUIT THE EXISTING CONDITIONS. <br />7.(E) J-BOX DENOTES APPROXIMATE LOCATION OF EXISTING BOXES <br />IN ACCESSIBLE CEILING SPACE. ALL CONDUIT SHOWN FROM J-BOX <br />IS NEW UNLESS SHOWN OTHERWISE AS EXISTING. <br />8.EXISTING LOADS SHOWN ON PANEL SCHEDULES ARE BASED ON <br />ASSUMPTIONS MADE BY FIELD VISIT, ELECTRICAL BILLS OR PUBLIC <br />RESOURCES. NOTIFY ENGINEER IMMEDIATELY IF LOADS EXCEED <br />16AMPS ON ANY 20A/1P CIRCUIT. NO EXCEPTION. <br />9.CAREFULLY REVIEW ARCHITECT'S DEMO DRAWINGS FOR LOCATION <br />OF WALLS BEING REMOVED UNDER THE SCOPE OF THIS WORK AND <br />REMOVE ALL FEEDERS (CONDUITS AND WIRES) BACK TO THE LAST <br />DEVICE LEFT IN SERVICE. DON NOT LEAVE ABANDONED. <br />10.CAREFULLY REVIEW ARCHITECT'S DEMO DRAWINGS FOR EXISTING <br />FLOOR BOXES BEING REMOVED UNDER THIS SCOPE OF WORK. <br />REMOVE FLOOR BOXES AND FEEDERS (CONDUITS AND WIRES) <br />BACK TO LAST DEVICE LEFT IN SERVICE. DO NOT LEAVE <br />ABANDONED. <br /> STRIPING AND MARKINGS: <br />1.ACCESS AISLES SHALL BE MARKED WITH PAINTED BORDERLINES <br />AROUND THEIR PERIMETER <br />2.THE AREA WITHIN THE BORDERLINES SHALL BE MARKED WITH <br />HATCHED LINES A MINIMUM OF 36 INCHES ON CENTER <br />3.THE COLOR OF THE BORDERLINES, HATCHED LINES, AND LETTERS <br />SHALL CONTRAST WITH THAT OF THE SURFACE OF THE ACCESS <br />AISLE <br />4.THE COLOR OF ALL STRIPING AND MARKINGS SHALL NOT BE THE <br />BLUE COLOR USED FOR IDENTIFICATION OF ACCESSIBLE PARKING <br />SPACES PER 11B-502.3.3 <br />5.THE WORDS "NO PARKING" SHALL BE PAINTED WITHIN EACH <br />ACCESS AISLE IN LETTERS A MINIMUM OF 12 INCHES IN HEIGHT AND <br />LOCATED TO BE VISIBLE FROM THE ADJACENT VEHICULAR WAY <br />6.THE WORDS "EV CHARGING ONLY" SHALL BE PAINTED AT THE <br />LOWER END OF EACH EV SPACE IN LETTERS A MINIMUM OF 12 <br />INCHES IN HEIGHT. THE CENTERLINE OF THE TEXT SHALL BE 6 <br />INCHES MAXIMUM FROM THE CENTERLINE OF THE VEHICLE SPACE <br />AND ITS LOWER CORNER AT, OR LOWER SIDE ALIGNED WITH, THE <br />END OF THE PARKING SPACE. (11B-812.8.9) <br /> GROUNDING: <br />1.ALL SERVICES SUPPLYING THE BUILDING SHALL HAVE THE SAME <br />GROUNDING ELECTRODE SYSTEM. <br />2.REMOVAL OF A GRID INTERACTIVE INVERTER OR OTHER EQUIPMENT <br />SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE <br />GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE <br />AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. <br />3.GROUND BOND CONDUCTOR SHALL NOT BE SPLICED. <br />4.USE EQUAL OR APPROVED "LAY IN LUG" ILSCO, UL-467 RATED FOR <br />GROUNDING AND BONDING. HIGH STRENGTH COPPER ALLOY W/ SS <br />SCREW (AS NECESSARY) <br /> CONDUCTORS: <br />1.ALL CONDUCTORS SHALL BE COPPER UNLESS OTHERWISE NOTED. <br />2.ALL PROPOSED CONDUCTORS RATED FOR 90°C., HOWEVER EQUIPMENT <br />RATINGS SHALL BE ASSUMED TO BE 75°C FOR ALL BUILDING FEEDERS AND <br />THEREFORE TERMINATIONS PRIOR TO CONNECTION. INTERMEDIATE <br />JUNCTION BOX MAY BE REQUIRED TO CHANGE FROM 90°C TO 75°C <br />WIRING. MATERIAL SHALL BE COPPER AND 90°C RATED, SUITABLE FOR <br />SUN EXPOSURE AND WET LOCATIONS. FIELD APPLIED COATINGS ARE NOT <br />ACCEPTABLE. <br />3.ALL WIRE INSULATION TYPE SHALL BE EV WIRE FOR AC EV CIRCUIT RUNS. <br />4.EACH EV MODULE HAS A POSITIVE AND NEGATIVE EV WIRE "SUNLIGHT <br />RESISTANT" QUICK CONNECT PLUG IN LEAD. VERIFY COMPATIBLE <br />EXTENSION WIRE PRIOR TO INSTALLATION. <br />5.ALL INTER-MODULE SERIES CONNECTIONS TO BE TIE STRAPPED (W/ BLACK <br />UV RESISTANT TIE <br />625.41 OVERCURRENT PROTECTION: OVERCURRENT PROTECTION FOR <br />FEEDERS AND BRANCH CIRCUITS SUPPLYING EQUIPMENT SHALL BE <br />SIZED FOR CONTINUOUS DUTY AND SHALL HAVE A RATING OF NOT LESS <br />THAN 125 PERCENT OF THE MAXIMUM LOAD OF THE EQUIPMENT. WHERE <br />NONCONTINUOUS LOADS ARE SUPPLIED FROM THE SAME FEEDER, THE <br />OVER-CURRENT DEVICE SHALL HAVE A RATING OF NOT LESS THAN THE <br />SUM OF THE NON-CONTINUOUS LOADS <br />PLUS 125 PERCENT OF THE CONTINUOUS LOADS. <br />625.42 RATING: THE EQUIPMENT SHALL HAVE SUFFICIENT RATING TO <br />SUPPLY THE LOAD SERVED. ELECTRIC VEHICLE CHARGING LOADS SHALL <br />BE CONSIDERED TO BE CONTINUOUS LOADS FOR THE PURPOSES OF <br />THIS ARTICLE. <br />WHERE AN AUTOMATIC LOAD MANAGEMENT SYSTEM IS USED, THE <br />MAXIMUM EQUIPMENT LOAD ON A SERVICE AND FEEDER SHALL BE THE <br />MAXIMUM LOAD PERMITTED BY THE AUTOMATIC LOAD MANAGEMENT <br />SYSTEM. <br />625.43 DISCONNECTING: MEANS FOR EQUIPMENT RATED MORE THAN 60 <br />AMPERES OR MORE THAN 150 VOLTS TO GROUND, THE DISCONNECTING <br />MEANS SHALL BE PROVIDED <br />AND INSTALLED IN A READILY ACCESSIBLE LOCATION. THE <br />DISCONNECTING MEANS SHALL BE LOCKABLE OPEN IN ACCORDANCE <br />WITH 110.25. <br />ACCESSIBLE ROUTES AND ACCESS AISLES: <br />1.ACCESS AISLES SHALL BE LEVEL WITH THE EV SPACE SERVED, AND <br />SLOPES/CROSS -SLOPES SHALL NOT EXCEED 1:48 <br />2.ACCESSIBILITY COMPLIANT EV SPACES SHALL BE LOACTED ON AN <br />ACCESSIBLE ROUTE TO AN ACESSIBLE BUILDING ENTRANCE. (11B-206.4 <br />& 11B-812.5) <br />3.EVCS SHALL BE DESIGNED SO ACCESSIBLE ROUTES ARE NOT <br />OBSTRUCTED BY CABLES OR OTHER ELEMENTS. (11B-812.5.5) <br />4.PROVIDE CURBS, WHEEL STOPS, BOLLARDS, OR OTHER BARRIERS TO <br />PREVENT ENCROACHMENT OF VEHICLE OVER THE REQUIRED CLEAR <br />WIDTH OF ACCESSIBLE ROUTES. (11B-812.5.3) <br />WIRING METHODS: <br />1.FOR UNDERGROUND AND EXPOSED UP TO +5'-0" OR DAMP LOCATION, <br />THE CONDUIT SHALL BE RIGID STEEL GALVANIZED IMC. NO RUNNING <br />THREADS ARE PERMITTED. <br />2.GALVANIZED EMT SHALL BE USED IN DRY CONCEALED LOCATIONS AN <br />EXPOSED ABOVE +5-0". EMT CONNECTORS SHALL BE WATERTIGHT <br />COMPRESSION TYPE. <br />3.GALVANIZED FLEXIBLE CONDUIT SHALL BE USED ONLY FOR MOTOR AND <br />FIXTURE CONNECTIONS IN LENGTHS NOT TO EXCEED 66' <br />4.CONDUITS PENETRATING THE ROOF SHALL BE FLASHED AND COUNTER <br />FLASHED. <br />5.INSTALL FITTINGS, SPECIAL DEVICES AND MATERIAL, WHICH MAY BE <br />REQUIRED FOR THE PROPER INSTALLATION OF THE CONDUIT SYSTEM. <br />NOTE: <br />110.27(B)PREVENT PHYSICAL DAMAGE:IN LOCATIONS <br />WHERE ELECTRICAL EQUIPMENT IS LIKELY TO BE <br />EXPOSED TO PHYSICAL DAMAGE, ENCLOSURES OR <br />GAURDS SHALL BE SO ARRANGED AND OF SUCH <br />STRENGTH AS TO PREVENT SUCH DAMAGE. <br />DEDICATED ELECTRICAL SPACE: WIDTH AND DEPTH <br />OF EQUIPMENT EXTENDING FROM THE FLOOR TO <br />1.8M (6FT) ABOVE EQUIPMENT OR TO STRUCTURAL <br />CEILING <br />NOTE: <br />NEW SERVICES IS LOCATED OUTDOORS IN THE <br />PARKING SPACES THAT ARE BELOW THE RESIDENTIAL <br />UNITS <br />NOTE: <br />"ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, <br />LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED <br />TESTING LABORATORY ACCREDITED BY THE UNITED <br />STATES OCCUPATIONAL SAFTY HEALTH <br />ADMINISTRATION." <br />1109.16 General. Where Electric Vehicle Charging <br />Stations are provided, all charging stations shall be <br />provided in accordance with this section and <br />applicable portions of ICC A117.1. <br />1109.16.1 Existing facilities. Where Electric Vehicle <br />Charging Stations are either added or altered within a <br />facility having existing Electric Vehicle Charging Stations, <br />the requirements this section shall apply only to the <br />newly installed or altered Electric Vehicle Charging <br />Stations. <br />1109.16.2 Minimum number. Where Electric Vehicle <br />Charging Stations are provided for public use, the <br />minimum number of accessible Electric Vehicle Charging <br />Stations shall be provided in accordance with Table <br />1109.16.2. Where new Electric Vehicle Charging <br />Stations are installed in facilities with existing Electric <br />Vehicle Charging Stations, the total number provided in <br />Table 1109.16.2 shall include both existing and new <br />Electric Vehicle Charging Stations. Where an Electric <br />Vehicle Charging Station charger can simultaneously <br />charge more than one vehicle, the number of Electric <br />Vehicle Charging Station chargers provided shall be <br />considered equivalent to the number of electric vehicles <br />that can be simultaneously charged. <br />Parking spaces serving Electric Vehicle Charging <br />Stations per this section shall not account for any of the <br />accessible parking spaces (as required by Section 1106) <br />on the site unless specifically provided with accessible <br />identification signage per Section 1109.16.6. <br />Exception: <br />1.Electric Vehicle Charging Stations not available to <br />the general public and intended for use by a designated <br />vehicle or driver shall not be required to comply with this <br />section. Examples include, but are not limited to, <br />charging stations serving public or private fleet vehicles, <br />assigned to an employee, or serving private residences. <br />2010 E Warner Ave, Bldg P <br />- 101119118 & 20182681 <br />7/8/2024