Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />412 <br />= 3x8 <br />=1.5x4 <br />=3x4 <br />=3x4 <br />=6x8 <br />=4x8 =3x10 <br />=1.5x4 =6x8 <br />=3x4 <br />=3x4 <br />=1.5x4 <br />=3x8 <br />111 <br />17 16 15 14 13 12 <br />102 <br />3324 <br />3 9 <br />25 32426 27 28 6 29 30 31 7 <br />5 8 <br />1-0-0 <br />-1-0-0 <br />1-0-0 <br />27-11-4 <br />3-5-15 <br />13-5-10 <br />3-5-15 <br />16-11-9 <br />4-2-4 <br />4-2-4 <br />4-2-4 <br />26-11-4 <br />5-9-7 <br />22-9-0 <br />5-9-7 <br />9-11-11 <br />3-2-12 <br />7-5-0 <br />3-2-12 <br />22-9-0 <br />4-2-4 <br />4-2-4 <br />4-2-4 <br />26-11-4 <br />6-0-10 <br />13-5-10 <br />6-0-10 <br />19-6-4 <br />3- <br />1 <br />1 <br />- <br />9 <br />0- <br />3 <br />- <br />1 <br />5 <br />0- <br />1 <br />1 <br />- <br />9 <br />2- <br />8 <br />- <br />4 <br /> <br />2- <br />8 <br />- <br />4 <br />0- <br />1 <br />1 <br />- <br />9 <br />3- <br />7 <br />- <br />1 <br />3 <br />Scale = 1:52.3 <br />Plate Offsets (X, Y): [4:0-3-13,0-2-7], [7:0-3-13,0-2-7] <br />Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP <br />TCLL (roof)20.0 Plate Grip DOL 1.25 TC 0.61 Vert(LL) -0.18 14 >999 360 MT20 220/195 <br />TCDL 18.0 Lumber DOL 1.25 BC 0.47 Vert(CT) -0.75 13-14 >431 240 <br />BCLL 0.0 * Rep Stress Incr YES WB 0.39 Horz(CT) 0.17 10 n/a n/a <br />BCDL 10.0 Code IBC2021/TPI2014 Matrix-AS Wind(LL) 0.25 14-16 >999 240 Weight: 121 lb FT = 20% <br />LUMBER <br />TOP CHORD 2X4 DF No.1&Btr G <br />BOT CHORD 2X4 DF No.1&Btr G <br />WEBS 2X4 DF Std G <br />BRACING <br />TOP CHORD Structural wood sheathing directly applied, <br />except <br />2-0-0 oc purlins (3-0-0 max.): 4-7. <br />BOT CHORD Rigid ceiling directly applied. <br />REACTIONS (size) 2=0-5-8, 10=0-5-8 <br />Max Horiz 2=-56 (LC 10) <br />Max Uplift 2=-300 (LC 12), 10=-300 (LC 12) <br />Max Grav 2=1459 (LC 1), 10=1459 (LC 1) <br />FORCES (lb) - Maximum Compression/Maximum <br />Tension <br />TOP CHORD 1-2=0/25, 2-3=-3603/1540, 3-4=-3462/1775, <br />4-5=-68/0, 4-6=-4034/1905, 6-7=-4034/1905, <br />7-8=-68/0, 7-9=-3462/1776, <br />9-10=-3603/1542, 10-11=0/25 <br />BOT CHORD 2-17=-1503/3383, 16-17=-1503/3383, <br />14-16=-1762/3313, 13-14=-1624/3313, <br />12-13=-1366/3383, 10-12=-1366/3383 <br />WEBS 4-16=0/240, 4-14=-519/959, 6-14=-470/261, <br />7-14=-520/959, 7-13=0/240, 3-16=-273/67, <br />3-17=0/96, 9-13=-271/67, 9-12=0/96 <br />NOTES <br />1) Unbalanced roof live loads have been considered for <br />this design. <br />2) Wind: ASCE 7-16; Vult=130mph (3-second gust) <br />Vasd=103mph; TCDL=9.0psf; BCDL=6.0psf; h=25ft; <br />B=45ft; L=27ft; eave=4ft; Cat. II; Exp C; Enclosed; <br />MWFRS (directional) and C-C Exterior(2E) -1-0-9 to <br />1-11-7, Interior (1) 1-11-7 to 9-11-11, Exterior(2R) 7-6-12 <br />to 10-6-12, Interior (1) 10-6-12 to 19-4-8, Exterior(2R) <br />16-11-9 to 19-11-9, Interior (1) 19-11-9 to 27-11-13 zone; <br />cantilever left and right exposed ; end vertical left and <br />right exposed;C-C for members and forces & MWFRS <br />for reactions shown; Lumber DOL=1.60 plate grip <br />DOL=1.60 <br />3) Provide adequate drainage to prevent water ponding. <br />4) This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />5) * This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />6) A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />7) All bearings are assumed to be DF No.1&Btr . <br />8) Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 300 lb uplift at joint <br />2 and 300 lb uplift at joint 10. <br />9) This truss design requires that a minimum of 7/16" <br />structural wood sheathing be applied directly to the top <br />chord and 1/2" gypsum sheetrock be applied directly to <br />the bottom chord. <br />10) Graphical purlin representation does not depict the size <br />or the orientation of the purlin along the top and/or <br />bottom chord. <br />LOAD CASE(S) Standard <br />Job Truss Truss Type Qty Ply 250065 1512 N Baker ADU <br />R87778792 <br />A4 California 1 1250065-A Job Reference (optional) <br />World International Truss, Victorville, CA - 92395, Run: 8.73 S Feb 19 2025 Print: 8.730 S Feb 19 2025 MiTek Industries, Inc. Mon Apr 21 10:48:22 Page: 1 <br />ID:TV1B9Fnf0UuiEUBIut4HXhznW39-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f <br />April 21,2025 <br />1512 N Baker St & Unit # 2-Truss <br />Drawings <br />5/8/2025