Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />412 <br />= 3x10 =2.5x4 <br />=3x4 <br />=3x4 <br />=M18AHS 7x14 <br />=4x8 <br />=1.5x4 <br />=7x8 WB <br />=2.5x4 <br />=3x8 =4x10 <br />=3x8 <br />=3x4 <br />=2.5x4 =3x10 <br />101 <br />92 <br />33 17 34 16 35 36 15 37 14 38 39 13 40 41 12 42 11 43 <br />3222 <br />3123 3 8 <br />4 24 25 5 26 27 28 6 29 30 7 <br />0-0-5 <br />18-11-9 <br />0-0-5 <br />8-0-0 <br />1-0-0 <br />-1-0-0 <br />1-0-0 <br />27-11-4 <br />3-4-10 <br />11-4-10 <br />3-4-10 <br />18-11-4 <br />4-1-15 <br />15-6-10 <br />3-11-5 <br />3-11-5 <br />3-11-5 <br />26-11-4 <br />4-0-6 <br />22-11-15 <br />4-0-6 <br />7-11-11 <br />3-5-11 <br />7-5-0 <br />3-5-11 <br />22-11-15 <br />3-11-10 <br />19-6-4 <br />3-11-10 <br />11-4-10 <br />3-11-5 <br />3-11-5 <br />3-11-5 <br />26-11-4 <br />4-1-15 <br />15-6-10 <br />3- <br />3 <br />- <br />9 <br />0- <br />3 <br />- <br />1 <br />5 <br />0- <br />3 <br />- <br />9 <br />2- <br />8 <br />- <br />4 <br />2- <br />8 <br />- <br />4 <br />0- <br />3 <br />- <br />9 <br />2- <br />1 <br />1 <br />- <br />1 <br />3 <br />Scale = 1:52.2 <br />Plate Offsets (X, Y): [4:0-7-2,0-1-6], [7:0-5-0,0-1-6] <br />Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP <br />TCLL (roof)20.0 Plate Grip DOL 1.25 TC 0.55 Vert(LL) -0.22 13-15 >999 360 M18AHS 169/162 <br />TCDL 18.0 Lumber DOL 1.25 BC 0.53 Vert(CT) -0.84 13-15 >387 240 MT20 220/195 <br />BCLL 0.0 * Rep Stress Incr NO WB 0.47 Horz(CT) 0.16 9 n/a n/a <br />BCDL 10.0 Code IBC2021/TPI2014 Matrix-MS Wind(LL) 0.23 13-15 >999 240 Weight: 280 lb FT = 20% <br />LUMBER <br />TOP CHORD 2X4 DF No.1&Btr G <br />BOT CHORD 2X6 DF SS G <br />WEBS 2X4 DF Std G <br />OTHERS 2X4 DF Std G <br />BRACING <br />TOP CHORD Structural wood sheathing directly applied or <br />4-6-15 oc purlins, except <br />2-0-0 oc purlins (3-10-11 max.): 4-7. <br />BOT CHORD Rigid ceiling directly applied or 10-0-0 oc <br />bracing. <br />REACTIONS (size) 2=0-5-8, 9=0-5-8 <br />Max Horiz 2=-43 (LC 10) <br />Max Uplift 2=-431 (LC 12), 9=-431 (LC 12) <br />Max Grav 2=3217 (LC 1), 9=3217 (LC 1) <br />FORCES (lb) - Maximum Compression/Maximum <br />Tension <br />TOP CHORD 1-2=0/25, 2-3=-8965/1305, 3-4=-8999/1318, <br />4-5=-10506/1530, 5-6=-10506/1530, <br />6-7=-8115/1229, 7-8=-8552/1267, <br />8-9=-8936/1315, 9-10=0/25 <br />BOT CHORD 2-17=-1174/8472, 16-17=-1174/8472, <br />15-16=-1143/8599, 13-15=-1417/10607, <br />12-13=-1417/10607, 11-12=-1186/8446, <br />9-11=-1186/8446 <br />WEBS 3-17=0/186, 3-16=-354/448, 4-16=0/539, <br />4-15=-337/2307, 5-15=-947/326, <br />6-15=-171/41, 6-13=0/422, 6-12=-2966/442, <br />7-12=-154/2004, 8-12=-394/210, 8-11=0/190 <br />NOTES <br />1) 2-ply truss to be connected together with 10d <br />(0.131"x3") nails as follows: <br />Top chords connected as follows: 2x4 - 1 row at 0-9-0 <br />oc. <br />Bottom chords connected as follows: 2x6 - 2 rows <br />staggered at 0-9-0 oc. <br />Web connected as follows: 2x4 - 1 row at 0-9-0 oc. <br />2) All loads are considered equally applied to all plies, <br />except if noted as front (F) or back (B) face in the LOAD <br />CASE(S) section. Ply to ply connections have been <br />provided to distribute only loads noted as (F) or (B), <br />unless otherwise indicated. <br />3) Unbalanced roof live loads have been considered for <br />this design. <br />4) Wind: ASCE 7-16; Vult=130mph (3-second gust) <br />Vasd=103mph; TCDL=9.0psf; BCDL=6.0psf; h=25ft; <br />B=45ft; L=27ft; eave=4ft; Cat. II; Exp C; Enclosed; <br />MWFRS (directional) and C-C Exterior(2E) -1-0-9 to <br />1-11-7, Interior (1) 1-11-7 to 7-6-12, Exterior(2R) 7-6-12 <br />to 11-9-11, Interior (1) 11-9-11 to 19-6-4, Exterior(2R) <br />19-6-4 to 23-9-3, Interior (1) 23-9-3 to 27-11-13 zone; <br />cantilever left and right exposed ; end vertical left and <br />right exposed;C-C for members and forces & MWFRS <br />for reactions shown; Lumber DOL=1.60 plate grip <br />DOL=1.60 <br />5) Provide adequate drainage to prevent water ponding. <br />6) All plates are MT20 plates unless otherwise indicated. <br />7) This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />8) * This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />9) A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />10) All bearings are assumed to be DF SS . <br />11) Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 431 lb uplift at joint <br />2 and 431 lb uplift at joint 9. <br />12) Graphical purlin representation does not depict the size <br />or the orientation of the purlin along the top and/or <br />bottom chord. <br />13) Hanger(s) or other connection device(s) shall be <br />provided sufficient to support concentrated load(s) 682 <br />lb down and 262 lb up at 7-11-12, 198 lb down and 139 <br />lb up at 10-0-12, 266 lb down and 162 lb up at 12-0-12, <br />287 lb down and 167 lb up at 13-5-10, 266 lb down and <br />162 lb up at 14-10-8, and 198 lb down and 139 lb up at <br />16-10-8, and 676 lb down and 262 lb up at 18-11-8 on <br />top chord, and 174 lb down and 26 lb up at 2-0-12, 84 lb <br />down at 4-0-12, 97 lb down at 6-0-12, 111 lb down at <br />8-0-12, 112 lb down at 10-0-12, 112 lb down at 12-0-12, <br />112 lb down at 13-5-10, 112 lb down at 14-10-8, 112 lb <br />down at 16-10-8, 111 lb down at 18-10-8, 97 lb down at <br />20-10-8, and 84 lb down at 22-10-8, and 174 lb down <br />and 26 lb up at 24-10-8 on bottom chord. The design/ <br />selection of such connection device(s) is the <br />responsibility of others. <br />LOAD CASE(S) Standard <br />1) Dead + Roof Live (balanced): Lumber Increase=1.25, <br />Plate Increase=1.25 <br />Uniform Loads (lb/ft) <br />Vert: 1-4=-76, 4-7=-76, 7-10=-76, 2-9=-20 <br />Concentrated Loads (lb) <br />Job Truss Truss Type Qty Ply 250065 1512 N Baker ADU <br />R87778793 <br />A5 California Girder 1 2250065-A Job Reference (optional) <br />World International Truss, Victorville, CA - 92395, Run: 8.73 S Feb 19 2025 Print: 8.730 S Feb 19 2025 MiTek Industries, Inc. Mon Apr 21 10:48:23 Page: 1 <br />ID:2rFLGzw6kgxnDaFfESJd9jznW4G-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f <br />Continued on page 2 <br />April 21,2025 <br />1512 N Baker St & Unit # 2-Truss <br />Drawings <br />5/8/2025