Laserfiche WebLink
RE <br />F <br />E <br />R <br /> <br />T <br />O <br />RC <br />P <br />EXISTING STRUCTURE <br />SUSPENDED CEILING REFER TO <br />R.C.P. FOR SPECIFICATION <br />2-1/2" x 20 GAUGE METAL STUD KICKERS @ 48" <br />O.C. ATTACH TO STRUCTURE ABOVE WITH 3 <br />8" DIA <br />HILT KB-TZ (ESR-1917) EMBEDDED 2" MIN. @ <br />24"O.C <br />7/8" SHADOW MOLDING <br />45° <br />6" <br />5/8" GYPSUM BOARD TO DECK ABOVE <br />ON ONE SIDE <br />(3) #10 SHEET METAL SCREWS <br />2-1/2" x 20 GAUGE METAL STUD. ATTACH TO <br />STRUCTURE WITH 3/8" DIA. HILTI KB-TZ <br />(ESR-1917) EMBEDDED 2" MIN. @ 24" O.C. <br />4'-0" O.C <br />. <br />2'-0" <br /> <br />O <br />. <br />C <br />. <br />MAX. <br />6" <br />4'-0"O <br />. <br />C <br />. <br />4'-0" <br />M <br />A <br />X <br />8" <br />·BRACING DETAIL <br /> USG OR EQUAL <br /> #ESR - 1222, LARR #25764 <br />6 <br />4 <br />2 <br />5 <br />3 <br />VERTICAL STRUT: A STRUT FASTENED TO THE MAIN <br />RUNNER SHALL BE EXTENDED TO AND FASTENED TO <br />THE STRUCTURAL MEMBERS SUPPORTING THE ROOF <br />OR FLOOR ABOVE. THE STRUT SHALL BE ADEQUATE <br />TO RESIST THE VERTICAL COMPONENT INDUCED BY <br />THE BRACING WIRE <br />THESE HORIZONTAL RESTRAINT POINTS SHALL BE <br />PLACED 12 FEET ON CENTER IN BOTH DIRECTIONS <br />WITH THE FIRST POINT WITHIN 6 FEET FROM EACH <br />WALL <br />ALL SUPPORT WIRES SHALL BE LOOPED AROUND <br />RUNNERS, JOIST, SCREW EYES, ETC., WITH MINIMUM <br />OF THREE TURNS, THEN TWISTED ABOUT <br />THEMSELVES A MINIMUM OF THREE TIMES, TYPICAL <br />UNLESS OTHERWISE NOTED <br />1 <br />2 <br />3 <br />7 <br />9 <br />2'-0" <br /> <br />O <br />. <br />C <br />. <br />MAX. <br />6" <br />4'-0"O <br />. <br />C <br />. <br />4'-0" <br />M <br />A <br />X <br />12'-0 <br />" <br /> <br />O <br />. <br />C <br />. <br />8" <br />LINE OF ALL OR END <br />OF SUSPENDED CLG. <br />CONSTRUCTION <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL <br /> AS PER I.C.C. # ESR - 1338. <br />1 <br />#12 GAUGE HANGER WIRES SPACED 4'-0" <br />O.C. ALONG 1 1/2" METAL CHANNELS. <br />LOCATE WITHIN 8" OF ENDS OF CHANNEL <br />RUNS. ATTACH WIRE TO COMPOSITE METAL <br />DECK WITH HILTI CEILING CLIP (CC27-ALH27) <br />ICC-ESR-2184. <br />1-1/2" x 20 GAUGE STEEL CHANNEL AT 4'-0" <br />O.C. PROVIDE 1" CLEARANCE BETWEEN <br />ABUTTING WALLS AND PARTITIONS. AT <br />CHANNEL SPLICES, INTERIOR LOCK FLANGES, <br />OVERLAP ENDS 12" AND SECURE EACH END <br />WITH DOUBLE STRAND 12 GAUGE TIE WIRE <br />7/8" x 20 GAUGE METAL FURRING CHANNEL <br />WITH 1" CLEARANCE BETWEEN FURRING <br />ENDS AND ABUTTING WALLS AND <br />PARTITIONS. ATTACH FURRING CHANNELS <br />TO A 1-1/2" CHANNEL WITH FURRING <br />CHANNEL CLIPS INSTALLED ON ALTERNATE <br />SIDES AT SPLICES, NEST FURRING CHANNELS <br />WITH AT LEAST 8" OVERLAP AND SECURELY <br />WIRE TIE EACH END WITH DOUBLE STRAND <br />12 GAUGE TIE WIRE <br />LATERAL SUPPORT WIRES, #12 GAUGE (MIN) <br />SPLAYED IN FOUR DIRECTIONS 90 DEGREES <br />APART. CONNECT TO 1-1/2" STEEL CHANNEL AT <br />6" MAX. FROM CROSS FURRING CHANNEL TO <br />STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING <br />45 DEGREES FROM PLANE OF CEILING. INSTALL <br />LATERAL SUPPORT WIRES AT 12'-0" INTERVALS <br />EACH DIRECTION WITH THE FIRST POINT AT 4'-0" <br />(MAX) FROM EACH WALL.. <br />5/8" GYPSUM BOARD. ATTACH GYPSUM BOARD <br />TO FURRING CHANNELS WITH #8 SHEET METAL <br />SCREWS AT 6" O.C. <br />VERTICAL COMPRESSION STRUT, STEEL SECTION <br />WITH L/R RATIO OF 200 MAX. ATTACH TO MAIN <br />RUNNERS WITH 1/4" MACHINE BOLTS AND TO <br />STRUCTURE WITH 3/8" DIA. HILTI KB-TZ <br />(ESR-1917) EMBEDDED 2" MIN. @ 24" O.C. <br />6 <br />5 <br />4 <br />8 <br />STRUT HEIGHT <br />6'-0" <br />8'-0"400S162-33 <br />14'-0" <br />METAL STUD SIZE <br />400S162-33 <br />(2)400S162-33 <br />Double Metal Studs <br />#10 SMS @ 12" O.C Staggered <br />Main runner <br />Furring channel <br />(2) Metal studs per schedule. <br />3" <br /> <br />M <br />A <br />X <br />. <br />Note: <br />L > 14'-0": Provide structural design calculstions <br />METAL STUD COMPRESSION STRUT SCHEDULE <br />SEISMIC DESIGN CATEGORIES D,E AND F. <br />1. SUSPENDED CEILINGS IN SEISMIC DESIGN CATEGORIES D,E, AND F SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ASTM <br />C635, ASTM 636 AND CISCA FOR SEISMIC ZONES 3-4 AS MODIFIED BY THE FOLLOWING: <br />2. A HEAVY DUTY T-BAR GRID SHALL BE USED <br />3. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN 2". IN EACH ORTHOGONAL HORIZONTAL <br />DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL <br />DIRECTION SHALL HAVE A 0.75 ". CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE ANGLE <br />4. FOR CEILING AREAS EXCEEDING 1,000 SF HORIZONTAL RESTRAINT OF THE CEILING TO THE STRUCTURAL SYSTEM SHALL BE PROVIDED. THE <br />TRIBUTARY AREAS OF THE HORIZONTAL RESTRAINTS SHALL APPROXIMATELY EQUAL <br />EXCEPTION: <br />A. RIGID BRACES ARE PERMITTED TO BE USED INSTEAD OF DIAGONAL SPLAY WIRES. BRACES AND ATTACHMENTS TO THE STRUCTURAL <br />SYSTEM ABOVE SHALL BE ADEQUATE TO LIMIT RELATIVE LATERAL DEFLECTIONS AT POINT OF THE ATTACHMENT OF THE CEILING GRID TO <br />LESS THAN O.25" FOR THE LOADS PRESCRIBED IN SECTION 13.3.OF MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES <br />B. FOR CEILING AREAS EXCEEDING 2,500 SF, A SEISMIC SEPARATION JOINT OR FULL HEIGHT PARTITION THAT BREAKS THE CEILING UP INTO <br />AREAS NOT EXCEEDING 2,500 SF SHALL BE PROVIDED UNLESS STRUCTURAL ANALYSES ARE PERFORMED OF THE CEILING BRACING <br />SYSTEM FOR THE PRESCRIBED SEISMIC FORCES THAT DEMONSTRATE CEILING SYSTEM PENETRATIONS AND CLOSURE ANGLES PROVIDE <br />SUFFICIENT CLEARANCE TO ACCOMMODATE THE ANTICIPATED LATERAL DISPLACEMENT <br />C. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS, SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A <br />2" OVERSIZE RING, SLEEVE, OR ADAPTER ROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL <br />DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1" OF THE CEILING MOVEMENT IN ALL HORIZONTAL <br />DIRECTIONS IS PERMITTED TO BE PROVIDED AT THE TOP OF THE SPRINKLER HEAD EXTENSION <br />D. SUSPENDED CEILINGS SHALL BE SUBJECT TO THE SPECIAL INSPECTION REQUIREMENTS OF ASCE 7-10, SECTION 11A.1.3.9, ITEM 2. <br />E. AS AN ALTERNATE TO PROVIDING LARGE CLEARANCES AROUND SPRINKLER SYSTEM PENETRATIONS THROUGH CEILING SYSTEMS, THE <br />SPRINKLER SYSTEM AND CEILING SYSTEM AND CEILING GRID ARE PERMITTED TO BE DESIGNED AND TIED TOGETHER AS AN INTEGRAL <br />UNIT. SUCH A DESIGN SHALL CONSIDER THE MASS AND FLEXIBILITY OF ALL ELEMENTS INVOLVED, INCLUDING THE CEILING SYSTEM, <br />SPRINKLER SYSTEM, LIGHT FIXTURES AND MECHANICAL (HVAC) APPURTENANCES. SUCH DESIGN SHALL BE PERFORMED BY A REGISTERED <br />DESIGN PROFESSIONAL <br />GENERAL NOTES: <br />1. LATERAL FORCE MEMBERS SHALL BE SPACED A MINIMUM OF 6" FROM ALL HORIZONTAL PIPING OR DUCTWORK THAT IS NOT PROVIDED <br />WITH BRACING RESTRAINS FOR HORIZONTAL FORCES. BRACING WIRES SHALL BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN <br />SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL LOAD, WHICHEVER IS <br />GREATER, WITH A SAFETY FACTOR OF 2. <br />2. STRUTS OTHER THAN THE ONES LISTED ABOVE MAY BE USED WITH AN EVALUATION REPORT BY I.C.C. OR OTHER NATIONALLY <br />ACCREDITED TESTING LABORATORY. <br />3. ALL 24" x 48" CEILING LIGHT FIXTURES & 24" x 24" HVAC AIR REGISTERS SHALL BE SUPPORTED BY A MIN. OF (2) TWO HANGERS @ <br />OPPOSITE CORNERS. CEILING SYSTEM SHALL NOT SUPPORT OTHER ITEMS. <br />4. ALL INTERIOR WALL & CEILING FINISHES SHALL BE INSTALLED IN ACCORDANCE WITH ASTM E 84 SHALL BE FLAME SPREAD CLASS III <br />MIN. <br />5. SPRINKLER HEADS AND OTHER PENETRATION CLEARANCE MIN. 2" DIA. OPENING OR A SWING JOINT <br />6. ARMSTRONG ACOUSTICAL CEILING SUSPENSION ICC ESR-1308 <br />4'-0" TYP <br />. <br />1. VERTICAL STRUT: A STRUT FASTENED TO THE <br />MAIN RUNNER SHALL BE EXTENDED TO AND <br />FASTENED TO THE STRUCTURAL MEMBERS <br />SUPPORTING THE ROOF OR FLOOR ABOVE. THE <br />STRUT SHALL BE ADEQUATE TO RESIST THE <br />VERTICAL COMPONENT INDUCED BY THE <br />BRACING WIRE. <br />2. HORIZONTAL RESTRAINT POINTS SHALL BE <br />PLACED 12 FEET ON CENTER IN BOTH <br />DIRECTIONS WITH THE FIRST POINT WITHIN 6 <br />FEET FROM EACH WALL. <br />VERTICAL STRUT (TYP) STD INSTALLATION PER <br />ASCE SECTION 13.5.6. <br />2'-0" <br />2'-0" <br />2" (MAX) FROM BRACING WIRE TO CROSS <br />RUNNERS. <br />METAL STUD COMPRESSION STRUT PER <br />SCHEDULE <br />1/4" DIA. MACHINE BOLT <br />ACOUSTICAL CEILING TILES <br />CEILING CLIP ASSEMBLY - HILTI CC-CLIP <br />FASTENED W/.177 DIA. POWER DRIVEN <br />FASTENER DX-KWIK, <br />LARR-25651-ICC ESR-2184, OR APPROVED <br />EQUAL <br />1-1/2"-3 TIGHT TURNS <br />12 GA. VERTICAL WIRE <br />SPLAYED BRACE WIRE <br />COMPRESSION STRUT ATTACHMENT DETAILS <br />12'-0" <br />45.0° <br />6'-0" <br />MAX. <br />6' <br />- <br />0 <br />" <br />MA <br />X <br />12 <br />' <br />- <br />0 <br />" <br />8" <br />TYPICAL 12 GA. VERTICAL HANGER WIRE @ <br />4'-0" O.C. EACH WAY W/ MIN. 3 TIGHT TURNS <br />IN 1-1/2" BOTH ENDS OF WIRE. <br />12GA. BRACING WIRE W/ MIN. 3 TIGHT TURNS IN <br />1-1/2" BOTH ENDS OF WIRE TYP. 90 APART @ 12'-0" <br />O.C. EA. WAY. <br />STARTING 6' FROM WALLS <br />45.0° <br />O.C. <br />CEILING GRID GRID MAIN RUNNER <br />12 GA. SPLAYED SEISMIC BRACING WIRE. <br />3 TIGHT TURNS <br />VERTICAL HANGER WIRE <br />ATTACHED TO STRUCTURE WITH 3/8" DIA. HILTI <br />KB-TZ (ESR-1917) EMBEDDED 2" MIN. @ 24" O.C. <br />CEILING CLIP ASSEMBLY - HILTI CC-CLIP <br />FASTENED W/.177 DIA. POWER DRIVEN <br />FASTENER DX-KWIK, <br />LARR-25651-ICC ESR-2184, OR APPROVED <br />EQUAL <br />EMT COMPRESSION STRUT PER SCHEDULE. <br />ENDS FLATTENED AND ATTACHED AS NOTED <br />COMPRESSION STRUT SCHEDULECOMPRESSION STRUT SCHEDULE <br />HEIGHT <br />3 / 4" EMT <br />METAL STUD OPTION <br />UP TO 5'-0"250TI25-33 (20 GA) <br />400S137-33 (20 GA) <br />-400S200-33 (20 GA) <br />UP TO 6'-0" <br />UP TO 7'-0" <br />UP TO 10'-0" <br />1" EMT <br />1 - 1 / 4" EMT <br />EMT OPTION <br />250TI25-33 (20 GA) <br /> > 10'-0" : Provide structural design calculations. <br />COMPRESSION STRUTS 12' O.C, BOTH DIRECTIONS, <br />STEEL SECTION WITH L/R RATION OF 200 MAX. <br />ATTACH TO MAIN RUNNERS WITH 1/4" MACHINE <br />BOLTS AND TO STRUCTURE WITH 3/8" DIA. HILTI <br />KB-TZ (ESR-1917) EMBEDDED 2" MIN. @ 24" O.C. <br />COMPRESSION STRUT SHALL NOT REPLACE HANGER <br />WIRE. <br />MAY BE STEEL STUD, BLACK IRON, EMT OR WOOD <br />STUD (IN COMBUSTIBLE CONSTRUCTION TYPES <br />ONLY) OR OTHER APPROVED EQUAL. <br />- <br />MAIN RUNNER <br />CROSS RUNNER <br />8" <br />UN <br />A <br />T <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />W <br />A <br />L <br />L <br />ATTACHED WALL <br />6 <br />- <br />10 <br />- <br />#12 AWG STEEL WIRE CONNECTOR USED FOR BOTH GRID SUPPORT AND FIXTURE <br />SUPPORT. ATTACH TO PERMANENT STRUCTURE. TYP. 6 PLACES <br />2' x 4' FIXTURE SHOWN. DETAIL IS TYPICAL FOR 2' x 2' , 1' x 4' AND MOST OTHER <br />RECESSED TROFFER FIXTURES. <br />TYPICAL OF A VARIETY OF TROFFER FIXTURE SUPPORT WIRE CONNECTION <br />TABS. <br />PROVIDE MIN. 3 COMPLETE TURNS OF WIRE NO MORE THAN 15" LONG (TYP.) <br />#10 TEK SCREWS LOCATED AT OPPOSITE CORNERS OF RUNNERS THRU INTEGRAL <br />FIXTURE SUPPORT TABS - ONE SCREW SHOWN FOR CLARITY. USE OF UL - LISTED <br />ACCESSORY FIXTURE SUPPORT TABS PROVIDED BY FIXTURE MANUFACTURER <br />MAY BE USED IF ACCEPTABLE WITH THE LOCAL CODES. SCREWS SHOULD NOT <br />EXTEND INTO THE BODY OF THE FIXTURE AS THIS MAY DISTORT FIXTURE BODY <br />CREATING LIGHT LEAKAGE. <br />#12 AWG STEEL WIRE CONNECTOR USED FOR BOTH GRID SUPPORT AND FIXTURE <br />SUPPORT. ATTACH TO PERMANENT STRUCTURE. TYP. 6 PLACES <br />2' x 4' FIXTURE SHOWN. DETAIL IS TYPICAL FOR 2' x 2' , 1' x 4' AND MOST OTHER <br />RECESSED TROFFER FIXTURES. <br />TYPICAL OF A VARIETY OF TROFFER FIXTURE SUPPORT WIRE CONNECTION <br />TABS. <br />PROVIDE MIN. 3 COMPLETE TURNS OF WIRE NO MORE THAN 15" LONG (TYP.) <br />#10 TEK SCREWS LOCATED AT OPPOSITE CORNERS OF RUNNERS THRU INTEGRAL <br />FIXTURE SUPPORT TABS - ONE SCREW SHOWN FOR CLARITY. USE OF UL - LISTED <br />ACCESSORY FIXTURE SUPPORT TABS PROVIDED BY FIXTURE MANUFACTURER <br />MAY BE USED IF ACCEPTABLE WITH THE LOCAL CODES. SCREWS SHOULD NOT <br />EXTEND INTO THE BODY OF THE FIXTURE AS THIS MAY DISTORT FIXTURE BODY <br />CREATING LIGHT LEAKAGE. <br />CROSS TEE <br />TEE-FACE SLEEVE <br />4-WAY SEISMIC <br />EXPANSION JOINT CLIP <br />FASTENER MAIN TEE <br />HANGER WIRE NEAR <br />TEE END <br />1" <br /> MIN. <br />FIELD CUT MAIN TEE <br />CROSS TEE <br />ONE SIDE OF SPLICE CAP CRIMPED TO <br />ALLOW MOVE MENT ONLY ON <br />OPPOSITE END <br />HANGER WIRE NEAR <br />TEE END <br />1" <br /> MIN. <br />3 FULL TWIST MIN. <br />T-BAR CEILING (SEE REFLECTED CLG. PLAN) IF <br />APPLICABLE <br />SCREW TIGHTENED THROUGH MAIN <br />RUNNER/CROSS TEE BULB OR WEB <br />7/8" <br />8" MAX <br />·CEILING TILE AND GRID <br /> ARMSTRONG ICC-ESR-1308 <br /> L.A. RR. #25032 <br />·SEISMIC WALL CLIP <br /> BERC2 OR EQUAL <br /> ICC - ESR 1308, LARR #25032 <br />ARMSTRONG 7/8" ANGLE MOLDING <br />ARMSTRONG BERC2 SEISMIC WALL <br />ATTACHMENT CLIP. <br />ARMSTRONG 7/8" ANGLE <br />MOLDING <br />ARMSTRONG BERC2 SEISMIC <br />WALL ATTACHMENT CLIP <br />HANGER WIRE <br />MAIN RUNNER/CROSS TEE <br />7/8" <br />B <br />B <br />B SECTION VIEW <br />A ISOMETRIC VIEW <br />SCREW TIGHTENED THROUGH <br />MAIN RUNNER/CROSS TEE BULB <br />OR WEB <br />T-BAR CEILING (SEE REFLECTED CLG. PLAN) IF <br />APPLICABLE <br />3/4" <br />7/8" <br />·CEILING TILE AND GRID <br /> ARMSTRONG ICC-ESR-1308 <br /> L.A. RR. #25032 <br />·SEISMIC WALL CLIP <br /> BERC2 OR EQUAL <br /> ICC - ESR 1308, LARR #25032 <br />ARMSTRONG 7/8" ANGLE MOLDING <br />ARMSTRONG BERC2 SEISMIC WALL <br />ATTACHMENT CLIP. <br />ARMSTRONG 7/8" ANGLE <br />MOLDING <br />ARMSTRONG BERC2 SEISMIC <br />WALL ATTACHMENT CLIP <br />HANGER WIRE <br />MAIN RUNNER/CROSS TEE <br />7/8" <br />B <br />B <br />B SECTION VIEW <br />A ISOMETRIC VIEW <br />LOOSE SLIP SCREW <br />3 FULL TWIST MIN. <br />LOOSE SLIP SCREW <br />8" MAX <br />3/4" <br />A-30.24 <br />6 <br />7 <br />10 <br />13 <br />14 <br />15 <br />16 <br />18 <br />SCALEEXPANSION JOINT <br />SCALE SCALE SCALE SCALE <br />SCALESUSPENDED GYP. BOARD CEILINGSCALE <br />SCALE LIGHT FIXTURE SEISMIC SUPPORT SCALE <br />CEILING DETAILS <br />COMPOSITE DECK <br />3"=1'-0" <br />1-1/2=1'-0" <br />1-1/2"=1'-0" <br />3"=1'-0" <br />17SCALE <br />NANOT USED <br />AS NOTED <br />1-1/2"=1'-0"SUSPENDED CEILING GRID DETAIL8SCALE <br />1-1/2"=1'-0" <br />PROJECT: <br />DATE: <br />DRAWN: <br />SCALE: <br />PROJECT NO: <br />REVIEWED: <br />SHEET NO: <br />SHEET TITLE: <br />STAMP AND SIGNATURE: <br />CONSULTANTS: <br />DATE DESCRIPTION DELTA <br />DRAWINGS ISSUE <br />02/15/2024 ISSUE FOR PLANNING APPROVAL <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />515 South Flower St., Suite 1200 <br />Los Angeles, CA 90071 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />www.saaia.com <br />T 310.553.3252 <br />T 213.929.1400 <br />T 949.724.8958 <br />San Francisco, CA 94105 <br />T 415.390.6793 <br />T 848.200.1200 <br />New York, NY 10017 <br />T 917.512.6688 <br />575 Market St., Suite 502 <br />711 3rd Ave., 6th Floor <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL <br />REMAIN IT'S PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE, <br />OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />12/18/23 <br />KL/SD/AW <br />MP <br />634772 <br />COUNTY OF ORANGE <br />PROBATION TRAINING & VOLUNTEER SERVICES <br />AND YOUTH REPORT CENTER <br />1700 E ST ANDREW PL <br />SANTA ANA, CA 92705 <br />C U L V E R C I T Y , C A •I R V I N E , C A • L O S A N G E L E S , C A <br />S A N F R A N C I S C O , C A • I S E L I N , N J • N E W Y O R K , N Y <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN <br />RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS <br />ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT <br />ANY TIME PER THEIR DISCRETION. IN USING RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT ACKNOWLEDGES THAT IT WAS BASED ON <br />THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS <br />AND MATERIALS BY OTHERS. SAA'S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT'S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR <br />COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT <br />BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />02/22/2024 ISSUE FOR PLAN CHECK / BID <br />02/26/2024 PLANNING COMMENTS A <br />04/03/2024 TENANT COMMENTS / FIELD REVISIONS B <br />AND PLAN CHECK COMMENTS 01 <br />ATTACHED - GRID TO WALL DETAIL <br />19 <br />20 <br />SCALE <br />SCALE <br />UNATTACHED - GRID TO WALL DETAIL <br />1ST & 2ND FLOOR <br />1-1/2"=1'-0"CEILING DETAIL <br />NANOT USED <br />NANOT USEDNANOT USED <br />NANOT USED NANOT USED <br />NELSON <br />ALGAZE <br />No. C-21090 <br />REN. 03/31/2025 <br />L <br />CENSE ARC <br />EC <br />SAE O CAL ORNA <br />1700 E St Andrew Pl - 101118387, <br />20182190, 30146952 & 40138878 <br />6/5/2024