20182190
30146952
40138878
Full Address
1700 E St Andrew Pl
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
471
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
STUD SIZE BLOCKING <br />SIZE MIL/GA 12"SPACING16"24" <br />250 11'-0" <br />362 14'-0" <br />400 15'-0" <br />600 19'-6" <br />NON-STRUCTURAL CEILING JOIST SPAN CHART <br />48" O.C. <br />10'-0"7'-6" <br />13'-0"11'-0" <br />14'-0"12'-0" <br />18'-0"16'-0" <br />SPAN LIMITS <br />43/18 48" O.C. <br />48" O.C. <br />48" O.C. <br />NOTES: <br />1. JOISTS ARE DESIGNED TO SUPPORT A CEILING DEAD LOAD OF 10 PSF. <br />2. CEILING JOIST ARE DESIGNED AS BRACED AT 4'-0" <br />1-1/2" x 1-1/2"x18GA CONTINUOUS <br />METAL ANGLE W/#10 S.M.S EACH SIDE AT <br />EACH STUD <br />(3) #8 S.M.S FROM JOIST TO STUD <br />METAL STUD CEILING JOIST PER CEILING JOIST <br />SPAN CHART. ATTACH W/3-#8 S.M.S <br />18 GA CONTINUOUS TRACK W/1-1/2" DEEP <br />LEG W/ (3) #8 S.M.S <br />METAL STUD WALL PER PLAN <br />METAL STUD WALL PER PLAN <br />AB <br />A METAL STUD CEILING JOIST CONNECTION TO METAL STUD <br />B METAL STUD CEILING JOIST CONNECTION TO METAL STUD <br />METAL STUD CEILING JOIST PER CEILING JOIST <br />SPAN CHART. <br />NOTES: <br />1.IT IS ACCEPTABLE TO USE EITHER DETAIL A OR B FOR <br />CEILING END JOIST CONNECTION. <br />2.CEILING JOIST NOT DESIGNED TO SUPPORT MECHANICAL <br />UNITS, WATER HEATERS, ETC. <br />3.PROVIDE 18GA DIAGONAL METAL STUD CONNECTING <br />INTERSECTION PARTITION WALL CORNERS W/ (4) #12 <br />S.M.S EACH END TO WALL TOP TRACK WHERE PARTITION <br />IS NOT FULL HEIGHT. <br />4.USE 3 <br />8" Ø EXPANSION ANCHORS W/2" EMBEDMENT AT <br />BOTTOM TRACK OF PARTITION WALL WHERE WALL IS <br />NOT BRACED TO DECK ABOVE. <br />BLOCKING <br />43/18 <br />43/18 <br />43/18 <br />ROUGH OPENING (C) <br />=DOOR WIDTH (A) + 2 1/2" <br />CUT OPENING IN GWB <br />= DOOR WIDTH + 3/8" <br />FREE PIVOTING HINGE <br />CONTINUOUS PERIMETER <br />EPDM GASKET <br />5 <br />8" GYP. BD. CEILING <br />FEATHER AS REQ. <br />CONCEALED HINGE <br />NOTE: <br />PROVIDE BAUCOPLUS 2 OR EQUAL CONCEALED HINGE ACCESS PANEL. VERIFY SIZE <br />WITH RCP. <br />METAL FRAMING AS <br />REQUIRED. <br />HEMBAR SEALED INSIDE SHADECLOTH IN <br />UP POSITION <br />SHADECLOTH IN DOWN POSITION <br />REMOVABLE CLOSURE (WHITE) <br />1/2" <br />MIN. <br />2-1/2" x 20 GAUGE MTL. STUD <br />AT 16" O.C <br />6" x 20 GAUGE MTL.NSTUD <br />AT 16" O.C <br />REFER TO RCP FOR CEILING HEIGHT <br />EXISTING EXTERIOR WALL <br />MECHOSHADE RFER TO <br />RCP FOR TYP. <br />(E) GLAZING SYSTEM <br />SINGLE CLOSURE MOUNT <br />CONTINUOUS BLOCKING <br />RE <br />F <br />E <br />R <br /> <br />T <br />O <br /> <br />S <br />P <br />E <br />C <br />. <br />REFER TO SPEC. <br />HEMBAR SEALED INSIDE SHADECLOTH IN <br />UP POSITION <br />SHADECLOTH IN DOWN POSITION <br />REMOVABLE CLOSURE (WHITE) <br />1/2" <br />MIN. <br />2-1/2" x 20 GAUGE MTL. STUD <br />AT 16" O.C <br />6" x 20 GAUGE MTL.NSTUD <br />AT 16" O.C <br />REFER TO RCP FOR CEILING HEIGHT <br />EXISTING EXTERIOR WALL <br />MECHOSHADE RFER TO <br />RCP FOR TYP. <br />(E) GLAZING SYSTEM <br />SINGLE CLOSURE MOUNT <br />CONTINUOUS BLOCKING <br />RE <br />F <br />E <br />R <br /> <br />T <br />O <br /> <br />S <br />P <br />E <br />C <br />. <br />REFER TO SPEC. <br />CEILING AND <br />MISCELLANEOUS <br />DETAILS <br />A-30.3 <br />1 <br />48 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />SCALE <br />SPECIFYNOT USED SCALE <br />SPECIFYNOT USED SCALE <br />SPECIFYNOT USED <br />SCALE <br />SPECIFYNOT USED SCALE <br />SPECIFYNOT USED SCALE <br />SPECIFYNOT USED <br />SCALE <br />3"=1'-0"CONCEALED HINGE ACCESS PANEL <br />SCALE <br />SPECIFYNOT USEDSCALE <br />SPECIFYNOT USEDSCALE <br />SPECIFYNOT USED <br />SCALE <br />SPECIFYNOT USED SCALE <br />SPECIFYNOT USED SCALE <br />SPECIFYNOT USED SCALE <br />SPECIFYNOT USED SCALE <br />SPECIFYNOT USED <br />AS NOTED <br />PROJECT: <br />DATE: <br />DRAWN: <br />SCALE: <br />PROJECT NO: <br />REVIEWED: <br />SHEET NO: <br />SHEET TITLE: <br />STAMP AND SIGNATURE: <br />CONSULTANTS: <br />DATE DESCRIPTION DELTA <br />DRAWINGS ISSUE <br />02/15/2024 ISSUE FOR PLANNING APPROVAL <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />515 South Flower St., Suite 1200 <br />Los Angeles, CA 90071 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />www.saaia.com <br />T 310.553.3252 <br />T 213.929.1400 <br />T 949.724.8958 <br />San Francisco, CA 94105 <br />T 415.390.6793 <br />T 848.200.1200 <br />New York, NY 10017 <br />T 917.512.6688 <br />575 Market St., Suite 502 <br />711 3rd Ave., 6th Floor <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL <br />REMAIN IT'S PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE, <br />OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />12/18/23 <br />KL/SD/AW <br />MP <br />634772 <br />COUNTY OF ORANGE <br />PROBATION TRAINING & VOLUNTEER SERVICES <br />AND YOUTH REPORT CENTER <br />1700 E ST ANDREW PL <br />SANTA ANA, CA 92705 <br />C U L V E R C I T Y , C A •I R V I N E , C A • L O S A N G E L E S , C A <br />S A N F R A N C I S C O , C A • I S E L I N , N J • N E W Y O R K , N Y <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN <br />RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS <br />ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT <br />ANY TIME PER THEIR DISCRETION. IN USING RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT ACKNOWLEDGES THAT IT WAS BASED ON <br />THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS <br />AND MATERIALS BY OTHERS. SAA'S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT'S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR <br />COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT <br />BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />02/22/2024 ISSUE FOR PLAN CHECK / BID <br />02/26/2024 PLANNING COMMENTS A <br />04/03/2024 TENANT COMMENTS / FIELD REVISIONS B <br />AND PLAN CHECK COMMENTS 01 <br />3SCALE <br />SPECIFYNOT USED <br />2SCALE <br />3"=1'-0"MECHOSHADE DETAIL <br />7SCALE <br />1ST & 2ND FLOOR <br />6SCALE <br />3" - 1'-0"TYPICAL CEILING JOIST SCHEDULE <br />SPECIFYNOT USED <br />NELSON <br />ALGAZE <br />No. C-21090 <br />REN. 03/31/2025 <br />L <br />CENSE ARC <br />EC <br />SAE O CAL ORNA <br />1700 E St Andrew Pl - 101118387, <br />20182190, 30146952 & 40138878 <br />6/5/2024