My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1401 W Highland St & #2 - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Highland St
>
1401 W Highland St Unit# 2
>
1401 W Highland St & #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 7:22:38 AM
Creation date
6/6/2025 7:22:26 AM
Metadata
Fields
Template:
Plan
Permit Number
101121664
Full Address
1401 W Highland St Unit# 2
Text box
ID:
1
Creator:
Import Agent
Created:
6/6/2025 7:22 AM
Modified:
6/4/2025 12:46 PM
Text:
12
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)900 @ 13' 5 1/4"3281 (1.50")Passed (27%)--1.0 D + 1.0 Lr (Alt Spans) <br />Shear (lbs)774 @ 12' 10 1/4"3806 Passed (20%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Moment (Ft-lbs)2085 @ 8' 4 3/8"4152 Passed (50%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Live Load Defl. (in)0.156 @ 7' 8 1/2"0.619 Passed (L/950)--1.0 D + 1.0 Lr (Alt Spans) <br />Total Load Defl. (in)0.298 @ 7' 8 3/8"0.825 Passed (L/499)--1.0 D + 1.0 Lr (Alt Spans) <br />System : Roof <br />Member Type : Flush Beam <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 3.54/12 <br />•Deflection criteria: LL (L/240) and TL (L/180). <br />•Overhang deflection criteria: LL (2L/240) and TL (2L/180). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger <br />• ¹ See Connector grid below for additional information and/or requirements. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Factored Accessories <br />1 - Beveled Plate - DF 3.50"3.50"1.50"263 265 528 Blocking <br />2 - Hanger on 7 1/4" SYP beam 3.50"Hanger¹1.50"422 478 900 See note ¹ <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)14' o/c <br />Bottom Edge (Lu)14' o/c <br />Connector: Simpson Strong-Tie <br />Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories <br />2 - Face Mount Hanger U46X SLD16 2.00"N/A 8-10dx1.5 4-10d <br />•Refer to manufacturer notes and instructions for proper installation and use of all connectors. <br />Dead Roof Live <br />Vertical Loads Location (Side)Tributary Width (0.90)(non-snow: 1.25)Comments <br />0 - Self Weight (PLF)0 to 13' 5 1/4"N/A 6.4 -- <br />1 - Tapered (PLF)0 to 1' 5"N/A 0.0 to 22.0 0.0 to 28.3 Generated from <br />Roof Geometry <br />2 - Tapered (PLF)1' 5" to 13' 5 1/4"N/A 0.0 to 92.4 0.0 to 120.2 Generated from <br />Roof Geometry <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to <br />www.weyerhaeuser.com/woodproducts/document-library. <br />The product application, input design loads, dimensions and support information have been provided by Sam Mobed <br />Weyerhaeuser Notes <br />All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.Member Length : 14' 2 1/4" <br />MEMBER REPORT PASSED <br />ROOF, HP-1 <br />1 piece(s) 4 x 8 DF No.1 <br />ForteWEB Software Operator Job Notes 1/12/2024 7:16:19 AM UTC <br />Sam Mobed <br />Nick Engineering Inc. <br />(310) 433-7927 <br />smobed@gmail.com <br />ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 <br />File Name: 1401 W Highland St (ADU) <br />Page 1 / 1 <br />1401 W Highland St & #2 - <br />101118574 & 766/10/2024
The URL can be used to link to this page
Your browser does not support the video tag.