Laserfiche WebLink
DOORS, DOORWAYS & GATES <br />1/4"=1'-0"DOOR CLEARANCES <br />18" MIN. <br />@ INTERIOR <br />DOOR <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />(A) <br />FRONT APPROACH, PULL SIDE <br />12" MIN * <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />(*) IF BOTH CLOSER AND LATCH ARE PROVIDED <br />36" MIN. <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />(D) <br />HINGE APPROACH, PULL SIDE <br />22" MIN. <br />44 <br />" <br /> M <br />I <br />N <br />. <br />* <br />(F) (G*) <br />HINGE APPROACH, PUSH SIDE <br />24" MIN.60 <br />" <br /> <br />M <br />I <br />N <br />. <br />(H) <br />LATCH APPROACH, PULL SIDE <br />24" MIN. <br />44 <br />" <br /> M <br />I <br />N <br />. <br /> <br />* <br />(J) (K*) <br />LATCH APPROACH, PUSH SIDE <br />(B) (C*) <br />FRONT APPROACH, PUSH SIDE <br />(*) 48" MIN. IF BOTH CLOSER AND LATCH PROVIDED. <br />(*) 48" MIN. IF CLOSER IS PROVIDED. <br />MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS AND GATES <br />18" MIN. @ INTERIOR60 <br />" <br /> <br />M <br />I <br />N <br />. <br />X <br />> <br /> <br />8 <br />" <br />(A) <br />PULL SIDE <br />MANEUVERING CLEARANCE AT RECESSED DOORS AND GATES <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />X <br />> <br /> <br />8 <br />" <br />(B) <br />PUSH SIDE <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />X <br />> <br /> <br />8 <br />" <br />(C) <br />PUSH SIDE, DOOR PROVIDED WITH <br />BOTH CLOSER AND LATCH <br />12" MIN. <br />24" MIN. <br />@ EXTERIOR SIDE <br />OF EXTERIOR <br />DOOR <br />24" MIN. @ EXTERIOR <br />32" MIN.32" MIN.32" MIN. <br />90 <br />(A) <br />HINGED DOOR <br />(B) <br />SLIDING DOOR <br />(C) <br />FOLDING DOOR <br />CLEAR WIDTH OF DOORWAYS <br />1.FLOOR OR GROUND SURFACE WITHIN REQUIRED MANEUVERING CLEARANCES SHALL HAVE A SLOPE NOT <br />STEEPER THAN 1:48. CHANGES IN LEVEL ARE NOT PERMITTED AT DOOR LANDINGS. <br />2.THRESHOLDS, IF PROVIDED AT DOORWAYS SHALL BE 1/2" HIGH MAX. RAISED THRESHOLDS AND <br />CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH DETAIL 10. <br />3.HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL BE <br />OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OR THE <br />WRIST. <br />4.THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 LBS (22.5 N) MAX. <br />5.OPERABLE PARTS OF DOOR HARDWARE SHALL BE 34" MIN. AND 44" MAX. ABOVE THE FINISH FLOOR OR <br />GROUND. <br />6.WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED <br />AND USABLE FROM BOTH SIDES. <br />7.DOOR AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90° THE TIME <br />REQUIRED TO MOVE THE DOOR TO A POSITION OF 12° FROM THE LATCH IS 5 SECONDS MIN. <br />8.DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70° THE <br />DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MIN. <br />9.THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE SHALL BE AS FOLLOWS: <br />9.1.INTERIOR HINGED DOORS AND GATES: 5 LBS (22.5 N) MAX. <br />9.2.SLIDING OR FOLDING DOORS: 5 LBS (22.5 N) MAX. <br />9.3.REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE <br />ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 LBS (66.7 N). <br />9.4.EXTERIOR HINGED DOORS: 5 LBS (22.5 N) MAX. <br />10.SWINGING DOOR AND GATE SURFACES WITHIN 10" OF THE FINISH FLOOR OR GROUND MEASURED <br />VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE <br />DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACE SHALL BE <br />WITHIN 1/16" OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES. <br />CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. <br />11.WHERE AUTOMATIC AND POWER-ASSISTED DOORS AND GATES WITHOUT STANDBY POWER ARE PART OF <br />A MEANS OF EGRESS THE CLEAR BREAK OUT OPENING AT SWINGING OR SLIDING DOORS AND GATES <br />SHALL BE 32" MIN. WHEN OPERATED IN EMERGENCY MODE. <br />DOORS, DOORWAYS & GATES <br />1/4"=1'-0"Door in Series <br />48" MIN.48" MIN. <br />(A)(B) <br />48" MIN. <br />(C) <br />FIG. 11B-404.2.4.6 <br />DOORS IN SERIES AND GATES IN SERIES <br />MOUNTING HEIGHTS <br />1/4"=1'-0"Mounting Height <br />EQUIPMENT <br />PERMITTED IN <br />SHADED AREA <br />FRONT & SIDE <br />APPROACH <br />INSULATE EXPOSED <br />PIPES AND SURFACES <br />18"-19" <br />36 <br />" <br /> <br />M <br />A <br />X <br />. <br />27 <br />" <br />MI <br />N <br />. <br />9" <br /> <br />M <br />I <br />N <br />. <br />6" <br />MAX. <br />8" <br />MIN. <br />38 <br />" <br />- <br />4 <br />3 <br />" <br />36 <br />" <br /> <br />M <br />A <br />X <br />. <br />24" MAX <br />17" MIN <br />6" <br />MAX. <br />8" <br />MIN. <br />29 <br />" <br /> <br />M <br />I <br />N <br />27 <br />" <br />MI <br />N <br />. <br />34 <br />" <br />MA <br />X <br />. <br />9" <br /> <br />M <br />I <br />N <br />. <br />15" MIN <br />30" CLR <br />FORWARD <br />APPROACH <br />13-1/2" MIN. <br />17 <br />" <br /> <br />M <br />A <br />X <br />. <br />44 <br />" <br />MA <br />X <br />. <br />6' <br />- <br />2 <br />" <br /> <br />M <br />I <br />N <br />. <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />18" <br />MIN. <br />6' <br />- <br />2 <br />" <br /> <br />M <br />I <br />N <br />. <br />35 <br />" <br /> <br />M <br />A <br />X <br />. <br />40 <br />" <br /> M <br />A <br />X <br />MIN <br />19"28 <br />" <br />- <br />3 <br />4 <br />" <br />27 <br />" <br />MI <br />N <br />. <br />SPOUT OUTLETSPOUT <br />OUTLET15" MIN.5" MAX. <br />MIRROR @ <br />LOCKER <br />ROOMS <br />54 <br />" <br /> <br />M <br />I <br />N <br />. <br />20 <br />" <br />MA <br />X <br />. <br />18" MIN <br />WHEELCHAIR ACCESSIBLE <br />DRINKING FOUNTAIN <br />MIRROR NOT OVER <br />A LAVATORY <br />FIXED TABLE <br />OR COUNTER <br />STANDING <br />DRINKING <br />FOUNTAIN URINALLAVATORY <br />ACCESSORIESMIRROR @ LAVATORY <br />& CHANGES IN LEVEL <br />N.T.S.Floor Sruface Level <br />1/ <br />4 <br />" <br />1/ <br />4 <br />" <br />1/ <br />2 <br />" <br />MA <br />X <br />. <br />1/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />1/2" MAX. <br />1/ <br />2 <br />" <br />MA <br />X <br />. <br />FLOOR OR GROUND SURFACES <br />DOMINANT DIRECTION OF TRAVEL <br />LONG DIMENSION <br />PERPENDICULAR <br />TO DOMINANT <br />DIRECTION OF <br />TRAVEL FIG. 302.3 <br />ELONGATED OPENINGS IN FLOOR OR GROUND SPACE <br />FIG. 302.2 <br />CARPET PILE HEIGHT <br />FIG. 303.2 <br />VERTICAL CHANGE IN LEVEL <br />FIG. 303.3 <br />BEVELED CHANGE IN LEVEL <br />2 <br />1 <br />NOTES: <br />1.FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT. <br />2.CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD OR BACKING OR NO CUSHION OR <br />PAD. CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, LEVEL CUT/UNCUT PILE TEXTURE. PILE <br />HEIGHT SHALL COMPLY WITH CARPET PILE HEIGHT FIGURE BELOW. EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR <br />SURFACES AND SHALL HAVE TRIM ON THE ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE SHALL COMPLY WITH CHANGE IN <br />LEVEL FIGURES BELOW. <br />DOORS, DOORWAYS & GATES <br />1/4"=1'-0"doorway and gate <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />(a) <br />FRONT APPROACH <br />24" MIN. <br />42 <br />" <br /> <br />M <br />I <br />N <br />. <br />(b) <br />SIDE APPROACH <br />MANEUVERING CLEARANCE AT DOORWAYS WITHOUT DOORS, SLIDING <br />DOORS, GATES AND FOLDING DOORS <br />22" MIN.42 <br />" <br /> <br />M <br />I <br />N <br />. <br />(c) <br />POCKET OR HINGE APPROACH <br />(d) <br />STOP OR LATCH APPROACH <br />11B-404.2.4.2 <br />GRAB BARS <br />N.T.S.Grab bars <br />POSITION OF GRAB BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 <br />INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP <br />OF THE GRIPPING SURFACE, EXCEPT THAT AT WATER CLOSETS FOR CHILDREN'S USE, GRAB <br />BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION 18 INCHES MINIMUM AND 27 INCHES <br />MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. <br />12 <br />" <br /> <br />M <br />I <br />N <br />. <br />1- <br />1 <br />/ <br />2 <br />" <br /> <br />M <br />I <br />N <br />. <br />(A) <br />PROJECTING <br />OBJECTS <br />(B) <br />RECESSED <br />OBJECTS <br />SPACING. THE SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1-1/2 INCHES. THE <br />SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS BELOW AND AT THE ENDS SHALL <br />BE 1-1/2 INCHES MINIMUM. THE SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS <br />ABOVE SHALL BE 12 INCHES MINIMUM. <br />CIRCULAR CROSS SECTION. GRAB BARS WITH CIRCULAR CROSS SECTIONS SHALL HAVE AN <br />OUTSIDE DIAMETER OF 1-1/4 INCHES MINIMUM AND 2 INCHES MAXIMUM. <br />SPACING OF GRAB BARS <br />FIG. 11B-609.3 <br />609.4 <br />609.3 <br />609.2.1 <br />4"-4.8" <br />PERIMETER <br />2" MAX. <br />2" M <br />A <br />X <br />. <br />(A)(B) <br />GRAB BAR NON-CIRCULAR CROSS SECTION <br />FIG. 609.2.2 <br />1-1/2" <br />CLEAR FLOOR OR GROUND SPACE <br />1/2"=1'-0"Floor space <br />48" MIN. <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />36" MIN.12" <br />MIN. <br />12" <br />MIN. <br />60" MIN. <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />36 <br />" <br /> <br />M <br />I <br />N <br />. <br />BASE <br />AR <br />M <br />AR <br />M <br />T-SHAPED TURNING SPACE <br />SIZE AND POSITION OF CLEAR FLOOR <br />SPACE <br />Ø60" <br />MIN <br />CIRCULAR TURNING SPACE <br />X <br />> 2 <br />4 <br />" <br />36" MIN. <br />X <br />> 1 <br />5 <br />" <br />60" MIN. <br />MANEUVERING CLEARANCE IN AN <br />ALCOVE, FORWARD APPROACH <br />MANEUVERING CLEARANCE <br />IN AN ALCOVE, PARALLEL <br />APPROACH <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />30" MIN. <br />(B) PARALLEL(A) FORWARD <br />48" MIN. <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />SIZE OF CLEAR FLOOR <br />SPACE <br />REACH RANGES <br />1/4"=1'-0"Reach Range <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />(A)(B) <br />20" MAX.>20"-25" MAX. <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />46 <br />" <br /> <br />M <br />A <br />X <br />. <br />10" MAX.> 10"- <br />24" MAX. <br />FIG. 308.3.1 FIG. 308.3.2 <br />FIG. 308.2.2FIG. 308.2.1 <br />UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH <br />OBSTRUCTED HIGH SIDE REACHUNOBSTRUCTED HIGH SIDE REACH <br />KNEE AND TOE CLEARANCE <br />1/4"=1'-0"Knee toe clear <br />9" <br /> <br />M <br />I <br />N <br />. <br />17"-25"6" <br />MAX. <br />30 <br />" <br />MI <br />N <br />. <br />(A) <br />ELEVATION <br />(B) <br />PLAN <br />11" <br />MIN. <br />8" <br />MIN. <br />27 <br />" <br />MI <br />N <br />. <br />9" <br /> <br />M <br />I <br />N <br />. <br />(A) <br />ELEVATION <br />(B) <br />PLAN <br />30 <br />" <br />MI <br />N <br />. <br />25" <br />MAX. <br />FIG. 11B-306.2 <br />TOE CLEARANCE <br />FIG. 11B-306.3 <br />KNEE CLEARANCE <br />11" <br />MIN. <br />8" <br />MIN. <br />27 <br />" <br />MI <br />N <br />. <br />9" <br /> <br />M <br />I <br />N <br />. <br />(C) <br />ELEVATION @ LAVATORY <br />29 <br />" <br /> <br />M <br />I <br />N <br />. <br />COMPARTMENTS & URINALS <br />1/4"=1'-0"Water_closet_urinal <br />56 <br />" <br /> <br />M <br />I <br />N <br />. <br />60" MIN. <br />17"-18"17"-19" <br />(A) <br />WHEELCHAIR <br />ACCESSIBLE WATER <br />CLOSETS <br />(B) <br />AMBULATORY <br />ACCESSIBLE WATER <br />CLOSETS <br />SIZE OF CLEARANCE AT WATER CLOSETS <br />42" <br />MIN. <br />12" MAX. <br />54" MIN. <br />TRANSFER <br />SIDE <br />24" MIN.12" MIN. <br />SIDE WALL GRAB BAR AT <br />WATER CLOSETS <br />REAR WALL GRAB BAR AT <br />WATER CLOSETS <br />19 <br />" <br />7"-9" <br />(B) <br />STALL TYPE <br />(A) <br />WALL HUNG TYPE <br />17 <br />" <br /> <br />M <br />A <br />X <br />. <br />13-1/2" MIN. <br />HEIGHT AND DEPTH <br />OF URINALS <br />36" MIN. <br />WATER CLOSETS AND TOILET <br />FIG. 11B-604.2 <br />FIG. 11B-604.3.1 <br />FIG. 11B-604.5.1 FIG. 11B-604.5.2 <br />FIG. 11B-605.2 <br />FIG. 11B-604.7 <br />9" <br />MI <br />N <br />. <br />6" <br />MIN. <br />6" <br />MI <br />N <br />. <br />12 <br />" <br />MI <br />N <br />. <br />6" <br />MIN. <br />35"-37" <br />44 <br />" <br /> M <br />I <br />N <br />. <br />AMBULATORY ACCESSIBLE <br />TOILET COMPARTMENT <br />FIG. 11B-604.8.2 <br />WHEELCHAIR ACCESSIBLE TOILET <br />COMPARTMENT TOE CLEARANCES <br />FIG. 11B-604.8.1.4 <br />(A) <br />ELEVATION ADULT <br />(B) <br />ELEVATION CHILDREN <br />(C) <br />PLAN <br />PARTITION <br />PARTITION <br />6" <br />MIN. <br />13-1/2" MIN. <br />CLEARANCE <br />DOOR PERMITTED TO SWING <br />OVER HATCHED PORTION OF <br />MANEUVERING SPACE <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />4" <br /> MAX. <br />4" <br />MA <br />X <br />. <br />ALTERNATE <br />DOOR <br />LOCATION <br />WHEELCHAIR ACCESSIBLE TOILET <br />COMPARTMENT DOORS <br />FIG. 11B-604.8.1.2 <br />56" MIN. @ WALL <br />MOUNTED WATER <br />CLOSET <br />59" MIN. @ FLOOR <br />MOUNTED WATER <br />CLOSET <br />48" MIN. <br />MANEUVERING <br />SPACE <br />CLEARANCE <br />56" MIN. @ WALL <br />MOUNTED WATER <br />CLOSET <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />59" MIN. @ FLOOR <br />MOUNTED WATER <br />CLOSET <br />48" MIN. <br />MANEUVERING <br />SPACE <br />CLEARANCE <br />36" MIN. <br />WHEN DOOR <br />SWINGS IN <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />DISPENSER OUTLET LOCATION <br />DOOR PERMITTED TO SWING <br />OVER HATCHED PORTION OF <br />MANEUVERING SPACE <br />56" MIN. @ WALL <br />MOUNTED WATER <br />CLOSET <br />59" MIN. @ FLOOR <br />MOUNTED WATER <br />CLOSET <br />60" MIN. <br />@ SIDE DOOR <br />MANEUVERING <br />SPACE <br />CLEARANCE <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />56" MIN. @ WALL <br />MOUNTED WATER <br />CLOSET <br />59" MIN. @ FLOOR <br />MOUNTED WATER <br />CLOSET <br />60" MIN. <br />MANEUVERING <br />SPACE <br />CLEARANCE <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />36" MIN. <br />WHEN DOOR <br />SWINGS IN <br />DOOR PERMITTED TO <br />SWING OVER HATCHED <br />PORTION OF <br />MANEUVERING SPACE <br />MANEUVERING SPACE WITH END-OPENING DOOR <br />FIG. 11B-604.8.1.1.3 <br />WATER CLOSET LOCATION <br />17 <br />" <br />- <br />1 <br />9 <br />" <br />34" MIN. <br />4" MAX. <br />34" MIN. <br />4" MAX. <br />A DOOR PULL SHALL BE <br />PLACED ON BOTH SIDES OF <br />THE DOOR NEAR THE LATCH <br />SHEET <br />PA / PM: <br />JOB NO.: <br />DRAWN BY: <br />CAUTION: 24"x36" <br />RE <br />M <br />A <br />R <br />K <br />S <br />DA <br />T <br />E <br />de <br />b <br />s <br />@ <br />s <br />h <br />p <br />a <br />r <br />t <br />n <br />e <br />r <br />s <br />. <br />n <br />e <br />t <br />ma <br />r <br />c <br />o <br />h <br />@ <br />s <br />h <br />p <br />a <br />r <br />t <br />n <br />e <br />r <br />s <br />. <br />n <br />e <br />t <br />(7 <br />1 <br />4 <br />) <br />3 <br />9 <br />0 <br />. <br />8 <br />6 <br />0 <br />0 <br />ar <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />n <br />i <br />n <br />g <br />PA <br />R <br />T <br />N <br />E <br />R <br />S <br />ww <br />w <br />. <br />s <br />h <br />p <br />a <br />r <br />t <br />n <br />e <br />r <br />s <br />. <br />n <br />e <br />t <br />07 <br />- <br />0 <br />3 <br />- <br />2 <br />0 <br />2 <br />4 <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />UN <br />I <br />T <br />E <br />D <br /> <br />M <br />E <br />D <br />I <br />C <br />A <br />L <br /> <br />I <br />M <br />A <br />G <br />I <br />N <br />G <br /> <br />H <br />E <br />A <br />L <br />T <br />H <br />C <br />A <br />R <br />E <br />80 <br />0 <br /> <br />N <br />. <br /> <br />T <br />U <br />S <br />T <br />I <br />N <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />TE <br />N <br />A <br />N <br />T <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br /> <br />F <br />O <br />R <br />: <br />Un <br />i <br />t <br />e <br />d <br /> <br />M <br />e <br />d <br />i <br />c <br />a <br />l <br /> <br />I <br />m <br />a <br />g <br />i <br />n <br />g <br /> <br />H <br />e <br />a <br />l <br />t <br />h <br />c <br />a <br />r <br />e <br />SU <br />I <br />T <br />E <br /> <br />- <br /> <br />H <br />AC <br />C <br />E <br />S <br />S <br />I <br />B <br />I <br />L <br />I <br />T <br />Y <br /> <br />D <br />E <br />T <br />A <br />I <br />L <br />S <br />G.3 <br />mh <br />DS/MH <br />23-16 <br />3 <br />812 <br />11 <br />10 <br />913 <br />15 <br />16 4 <br />800 N Tustin Ave Unit <br />#H1/23/2025