Laserfiche WebLink
SYMBOLS LEGENDABBREVIATIONS <br />-#- <br />1P SINGLE POLE <br />1PH SINGLE-PHASE <br />2/C TWO-CONDUCTOR <br />3/C THREE-CONDUCTOR <br />3PH THREE-PHASE <br />4/C FOUR-CONDUCTOR <br />-A- <br />A/E ARCHITECT/ENGINEER <br />AC ALTERNATING CURRENT <br />ACC ACCESSIBLE <br />ADA AMERICANS DISABILITIES ACT <br />ADDL ADDITIONAL <br />ADDM ADDENDUM <br />AH AMPERE HOUR <br />AHJ AUTHORITY HAVING JURISDICTION <br />AMP AMPERE <br />ANN ANNUNCIATOR <br />ANT ANTENNA <br />APPD APPROVED <br />APPX APPENDIX <br />ARCH ARCHITECT <br />ATS AUTOMATIC TRANSFER SWITCH <br />AUTO AUTOMATIC <br />AUX AUXILIARY <br />AV AUDIO VISUAL <br />AVG AVERAGE <br />AWG AMERICAN WIRE GAUGE <br />-B- <br />BAS BUILDING AUTOMATION SYSTEM <br />BAT BATTERY <br />BC BUILDING CODE <br />BFF BELOW FINISH FLOOR <br />BKGD BACKGROUND <br />BLDG BUILDING <br />BLW BELOW <br />BRKR BREAKER <br />BRZ BRONZE <br />BSMT BASEMENT <br />BSTR BOOSTER <br />BTWN BETWEEN <br />BX INTERLOCKED ARMORED CABLE <br />-C- <br />CAB CABINET <br />CAP CAPACITOR <br />CATW CATWALK <br />CB CIRCUIT BREAKER <br />CCTV CLOSED CIRCUIT TELEVISION <br />CD CONSTRUCTION DOCUMENT <br />CERT CERTIFY <br />CF CONTRACTOR FURNISHED <br />CG COMMON GROUND <br />CHK CHECK <br />CKT CIRCUIT <br />CKT <br />BRKR CIRCUIT BREAKER <br />CL CENTER LINE / CLOSE <br />CLG CEILING <br />CLO CLOSET <br />CLR CLEAR <br />C CONDUIT <br />CO CONDUIT ONLY <br />COAX COAXIAL CABLE <br />COL COLUMN <br />COM COMMON <br />COMPR COMPRESSOR <br />COMM COMMUNICATION <br />CONC CONCRETE <br />CONST CONSTRUCTION <br />CORR CORRIDOR <br />CP CONTROL PANEL <br />CSI CONSTRUCTION SPECIFICATION INSTITUTE <br />CT CURRENT TRANSFORMER <br />CTRL CONTROL <br />CATV CABLE TELEVISION <br />-D- <br />DC DIRECT CURRENT <br />DEF DEFINITION <br />DEG DEGREE <br />DEMO DEMOLITION <br />DET DETAIL <br />DGTL DIGITAL <br />DIA DIAMETER <br />DIAG DIAGRAM <br />DIM DIMENSION <br />DIR DIRECTION <br />DISC DISCONNECT <br />DISCH DISCHARGE <br />DISTR <br />PNL DISTRIBUTION PANEL <br />DIV DIVISION <br />DMR DIMMER <br />DS DISCONNECT SWITCH <br />DWG DRAWING <br />DX DUPLEX <br />-E- <br />EA EACH <br />EL ELEVATION <br />ELEC ELECTRIC <br />EMER EMERGENCY <br />EMR ELEVATOR MACHINE ROOM <br />EMS ENERGY MANAGEMENT SYSTEM <br />EMT ELECTRICAL METALLIC TUBING <br />ENGR ENGINEER <br />EQ EQUAL <br />EQUIP EQUIPMENT <br />EQUIV EQUIVALENT <br />ESR ELECTRICAL SERVICE REQUIREMENT <br />ETR EXISTING TO BE RELOCATED <br />EX EXAMPLE <br />EXH FN EXHAUST FAN <br />EXIST EXISTING <br />EXT EXTERNAL <br />EXT LT EXIT LIGHT <br />-F- <br />F FAHRENHEIT <br />FA FIRE ALARM <br />FC FOOTCANDLE <br />FDR FEEDER <br />FLA FULL LOAD AMPS <br />FLEX FLEXIBLE <br />FLMT FLUSH MOUNT <br />FLR FLOOR <br />FLUOR FLUORESCENT <br />FR FIRE RATING <br />FREQ FREQUENCY <br />FT FOOT <br />FU FUSE <br />FU SW FUSED SWITCH <br />FUT FUTURE <br />-G- <br />G GROUND <br />GC GENERAL CONTRACTOR <br />GEN GENERATOR <br />GFCI GROUND FAULT CIRCUIT INTERRUPTER <br />GFR GROUND FAULT RELAY <br />GRD OUT GROUNDED OUTLET <br />-H- <br />HP HORSEPOWER <br />HZ HERTZ <br />-J- <br />JB JUNCTION BOX <br />-L- <br />LED LIGHT EMITTING DIODE <br />LM LUMEN <br />LT LIGHT <br />LTG LIGHTING <br />LTG PNL LIGHTING PANEL <br />LV LOW VOLTAGE <br />-M- <br />MAX MAXIMUM <br />MCB MAIN CIRCUIT BREAKER <br />MCC MOTOR CONTROL CENTER <br />MECH MECHANICAL <br />MIN MINIMUM <br />-N- <br />NEUT NEUTRAL <br />NTS NOT TO SCALE <br />-P- <br />P POLE <br />PB PULL BOX <br />PH PHASE <br />PNL PANEL <br />PWR POWER <br />-R- <br />R REMOVE <br />RE RELOCATED EXISTING <br />REC RECESSED <br />RECPT RECEPTACLE <br />REQD REQUIRED <br />RM ROOM <br />-S- <br />SD SMOKE DETECTOR <br />SPEC SPECIFICATION <br />SPKR SPEAKER <br />SWBD SWITCHBOARD <br />SWGR SWITCHGEAR <br />-T- <br />TC TIME CLOCK <br />TEL TELEPHONE <br />TELCOM TELECOMMUNICATIONS <br />THRU THROUGH <br />TV TELEVISION <br />TVSS TRANSIENT VOLTAGE SURGE SUPRESSOR <br />TYP TYPICAL <br />-U- <br />UC UNDERCOUNTER <br />UG UNDERGROUND <br />UL UNDERWRITERS LABORATORIES <br />UON UNLESS OTHERWISE NOTED <br />UPS UNINTERRUPTIBLE POWER SUPPLY <br />UGPS UNDERGROUND PULL SECTION <br />-V- <br />V VOLTAGE <br />VA VOLT AMPERE <br />VD VOLTAGE DROP <br />VFD VARIABLE FREQUENCY DRIVE <br />VIF VERIFY IN FIELD <br />-W- <br />W WATT OR WIRE <br />W/WITH <br />W/O WITHOUT <br />WP WEATHERPROOF <br />WR WEATHER RESISTANT <br />-X- <br />XFER TRANSFER <br />XFMR TRANSFORMER <br />GENERAL NOTES SHEET INDEX <br />SCOPE OF WORK <br />TENANT IMPROVEMENT FOR THE UNITED MEDICAL IMAGING CENTER. ELECTRICAL SUBMITTAL FOR ENERGY AND <br />POWER REQUIREMENTS. <br />NEW 400A, 277/480V, 3PH, 4W ELECTRICAL SERVICE FROM SOUTHERN CALIFORNIA EDISON (SCE). <br />1.GREEN INSULATED COPPER GROUNDING CONDUCTOR SHALL BE INSTALLED IN ALL <br />BRANCH CIRCUITS AND FEEDERS. <br />2.ALL LIGHTING CONTROL DEVICES SHALL BE CALIFORNIA ELECTRICAL CODE <br />CERTIFIED. <br />3.PROJECT SPECIFICATIONS ARE AN INTEGRAL PART OF THESE DRAWINGS. <br />4.UNLESS LISTED OTHERWISE, THE AMPACITY OF 600V OR LESS CONDUCTOR SHALL <br />BASED ON THE TERMINALS NOT TO EXCEED 60°C(140°F) FOR CONDUCTOR SIZE 14 <br />THROUGH 1AWG OR 75°C(167°F) FOR CONDUCTOR SIZES OVER 1AWG. <br />5.A SINGLE RECEPTACLES INSTALLED ON AN INDIVIDUAL BRANCH CIRCUIT SHALL HAVE <br />AN AMPERE RATING OF NOT LESS THAN THAT OF THE BRANCH CIRCUIT. INDICATE <br />THE RECEPTACLES RATING. <br />6.MINIMUM SIZE OF CONDUIT SHALL BE 3/4". MINIMUM SIZE OF NEUTRAL CONDUCTOR <br />SHALL BE #10 AWG, U.O.N. MINIMUM SIZE OF CONDUCTOR SHALL BE #12 AWG, U.O.N. <br />MINIMUM CONDUCTOR SIZE AT 120 VOLTS AND OVER 100FT CIRCUIT LENGTH SHALL <br />BE #10 AWG, U.O.N. MINIMUM CONDUCTOR SIZE AT 277 VOLTS AND OVER 200FT. <br />CIRCUIT LENGTH SHALL BE #10AWG U.O.N. <br />7.PROVIDE DEDICATED NEUTRALS FOR ALL BRANCH CIRCUITRY. <br />8.THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE OF THE WORK AND <br />THOROUGHLY FAMILIARIZE HIMSELF WITH THE WORKING CONDITION AND THE EXACT <br />NATURE AND EXTENT OF THE WORK TO BE PERFORMED. ELECTRICAL CONTRACTOR <br />IS TO TAKE INTO CONSIDERATION SPECIAL OR UNUSUAL FEATURES PECULIAR TO <br />THIS JOB. <br />9.MAINTAIN CLEARANCES PER AHJ REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT <br />INSTALLED. <br />10.OBTAIN AND PAY FOR ALL ELECTRICAL PERMITS, INSPECTION FEES, ETC. <br />11.CONDUIT STUBS SHALL BE TERMINATED IN ACCESSIBLE LOCATIONS, SECURELY <br />CAPPED AND IDENTIFIED BY VISIBLE MARKER. <br />12.INSTALL APPROVED GROUNDING BUSHING AT EACH TERMINATION OF RIGID <br />CONDUIT, AND AS OTHERWISE REQUIRED BY CODE. <br />13.PROVIDE A MINIMUM OF 12" SEPARATION BETWEEN POWER AND TELEPHONE <br />CONDUITS WHERE THEY ARE INSTALLED IN THE SAME TRENCH OR CROSS, U.O.N. <br />14.CONDUITS SHALL BE CLEAN OF WATER DEBRIS AND OTHER FOREIGN MATERIAL <br />PRIOR TO PULLING CABLES. <br />15.ALL CONDUITS FOR FUTURE USE SHALL HAVE PULL ROPE LEFT IN PLACE. <br />16.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING AND <br />MARKING THE CORRECT PHASING OF THE BRANCH CIRCUIT OF THE ELECTRICAL <br />PANELS AND BRANCH CIRCUITS. <br />17.ALL ELECTRICAL OUTLETS READILY ACCESSIBLE LOCATED IN THE BATHROOMS AND <br />KITCHEN SHALL BE EQUIPPED WITH GROUND FAULT CIRCUIT INTERRUPTIVE DEVICE <br />U.O.N. <br />18.ALL COLORS AND FINISHES OF ELECTRICAL EQUIPMENT AND LIGHTING FIXTURES TO <br />BE VERIFIED WITH OWNER AND/OR ARCHITECT PRIOR TO ORDERING. <br />19.ELECTRICAL CONTRACTOR TO SIZE ALL J-BOXES AS PER TABLE 370-16A. ALL <br />J-BOXES TO BE SQUARE 4"X 2-1/8" MINIMUM. ALL J-BOXES TO BE READILY <br />ACCESSIBLE. <br />20.ALL PANELBOARDS, SWITCHBOARDS, ETC. SHALL BE RATED AT 75 DEGREES <br />CELSIUS. <br />21.REFER TO ARCHITECTURAL OR SPACE PLANNING DRAWINGS FOR EXACT LOCATION <br />OF LIGHTING FIXTURES, FURNITURE AND OTHER EQUIPMENT. IN CASE OF ANY <br />DISCREPANCY BETWEEN THE ARCHITECTURAL OR ELECTRICAL DRAWINGS, THE <br />FORMER TAKES PRECEDENCE. ELECTRICAL CONTRACTOR TO INFORM THE <br />ENGINEER IMMEDIATELY. <br />22.FUSES SPECIFIED FOR MOTORS AND AIR CONDITIONING EQUIPMENT 600A AND <br />UNDER SHALL BE TIME DELAY DUAL ELEMENT TYPE FRN-R (250V) AND FRS-R (600V) <br />CLASS "L" U.O.N. <br />23.FUSES SPECIFIED IN SWITCHBOARDS 600A AND UNDER SHALL BE FAST ACTING TYPE <br />KTN-R (250V) AND KTS-R (600V) CLASS RKI. FOR 601A AND ABOVE USE TYPE KTU <br />(600V) CLASS "L" U.O.N. <br />24.WHERE VERIFICATION OF EXISTING CONDITIONS REQUIRE SIGNIFICANT <br />CONSUMPTION OF TIME AND LABOR, AN ASSUMPTION WAS MADE BASED ON THE <br />EXISTING DRAWINGS SUBMITTED BY THE CLIENT. ELECTRICAL CONTRACTOR IS TO <br />VERIFY THIS INFORMATION IN FIELD AND PERFORM ACCORDING TO EXISTING <br />CONDITIONS. <br />25.ALL ELECTRICAL MATERIALS SHALL BEAR THE UNDERWRITERS (OR EQUIVALENT <br />TESTING AGENCY) LABEL. ELECTRICAL EQUIPMENT SHALL BE LISTED BY A CITY OF <br />TUSTIN RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE <br />DEPARTMENT. <br />26.UNLESS INFORMED OTHERWISE IN WRITING, THIS PROJECT HAS BEEN DETERMINED <br />TO REQUIRE THE LOCAL CITY AUTHORITIES PLAN CHECK APPROVAL AND VALID <br />PERMIT IN ACCORDANCE WITH THE LAW. ALL DESIGN WORK INDICATED ON PLANS <br />AND SPECIFICATIONS IS SUBJECT TO REVIEW AND CHANGES BY SAID PLAN CHECK <br />AUTHORITIES. <br />27.DO NOT ORDER ANY EQUIPMENT OR PERFORM ANY WORK OVER $500 IN TOTAL <br />VALUE ON THE JOB UNTIL THE COMPLETION OF THE PLAN CHECK APPROVAL <br />PROCESS AND OBTAINING OF ALL REQUIRED PERMITS. INSTALLATION OF ANY <br />EQUIPMENT WITHOUT VALID PERMITS, WHEN REQUIRED, IS A VIOLATION OF THE <br />CODE. <br />28.UNDER THE STATE OF CALIFORNIA CONTRACTORS STATE LICENSE BOARD <br />REGULATIONS, ALL CONTRACTORS ARE REQUIRED TO ADHERE TO THE LOCAL <br />CODES AND LAWS WITHOUT EXCEPTION. <br />29.ELECTRICAL CONTRACTOR TO OBTAIN ARCHITECTURAL APPROVAL OF ALL LIGHTING <br />FIXTURES SPECIFIED FOR THE PROJECT PRIOR TO ORDERING. <br />30.ELECTRICAL CONTRACTOR SHALL PROVIDE CLEARANCES FOR ALL ELECTRICAL <br />EQUIPMENT PER TABLE 110.26 (A) (1) CEC 2019. <br />31.PROVIDE GROUND FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION ON <br />RECEPTACLE(S) LOCATED IN THE FOLLOWING AREAS: <br />A.KITCHEN, BATHROOM, GARAGES, OUTDOORS, CRAWL SPACES, AND <br />UNFINISHED BASEMENTS OF DWELLING UNITS. <br />B.WITHIN 6 FEET OF LAUNDRY, UTILITY AND WET BAR SINK IN DWELLING UNITS. <br />C.OUTDOOR SPACES. <br />36.THESE ELECTRICAL PLAN ARE SAID TO BE FINAL WHEN STAMPED AND APPROVED BY <br />CITY OF TUSTIN BUILDING & SAFETY DEPARTMENT. PLAN CHECK REVISIONS (IF ANY) <br />WILL BE ISSUED AT A LATER DATE AS AN ADDENDUM. <br />37.BONDING OF PIPING SYSTEMS IN ACCORDANCE WITH NEC ART. 250.90 SHALL <br />INCLUDE BONDING OF ALL WATER, GAS, FIRE SPRINKLER, COMPRESSED AIR AND/OR <br />ANY OTHER METALLIC PIPING. <br />38.THE WORK SHALL COMPLY WITH AND BE INSTALLED IN ACCORDANCE WITH THE <br />FOLLOWING LEGALLY CONSTITUTED AUTHORITIES AND CODES HAVING <br />JURISDICTION. <br />A.2022 CALIFORNIA ELECTRICAL CODE (CEC). <br />B.2022 CALIFORNIA BUILDING CODE (CBC). <br />C.2020 NATIONAL ELECTRICAL CODE (NEC). <br />D.2022 CALIFORNIA MECHANICAL CODE (CMC). <br />E.2022 CALIFORNIA PLUMBING CODE (CPC). <br />F.2022 CALIFORNIA ENERGY CODE (CENC). <br />40.(A) ALL EXPOSED CONDUITS (NOT SUBJECT TO THE MOISTURE) SHALL BE ELECTRIC <br />METALLIC TUBING (EMT). (B) EXPOSED RACEWAYS SHALL BE RIGID STEEL CONDUIT <br />(RSC). (C). ALL VIBRATING MOTORIZED EQUIPMENT FINAL CONNECTION SHALL BE <br />PROVIDED WITH LIQUID TIGHT FLEXIBLE CONDUIT. LENGTH SHALL NOT EXCEED 6-FT. <br />41.CONDUCTOR SIZING SHALL BE IN ACCORDANCE WITH ARTICLE 110.14(C) AND <br />ARTICLE 310.15. <br />42.NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE <br />PERMITTED TO BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL <br />EQUIPMENT. <br />43.120 VOLT SMOKE DETECTORS AND COMBINATION SMOKE & CO DETECTORS SHALL <br />BE FURNISHED & INSTALLED BY ELECTRICAL CONTRACTOR WITH ALL REQUIRED <br />LABOR, MATERIALS, CONDUITS, WIRING, BOXES AND 120 VOLT POWER FROM <br />DEDICATED LOCK-ON CIRCUIT BREAKER. <br />44.ALL 125V, 15 AND 20 AMPERE RECEPTACLE AS REQUIRED IN CEC SECTION 210.52 IN <br />DWELLING UNITS SHALL BE TAMPER-RESISTANCE. <br />45.FUSES SHALL BE PROVIDED WITH REJECTION TYPE FUSE HOLDERS. <br />46.OBTAIN APPROVAL AND PERMIT VIA SEPARATE SUBMITTAL FOR ANY ELECTRICAL <br />SUBSYSTEM WITH LOW VOLTAGE POWER SUPPLY OF MORE THAT 50VA AND/ OR 25V. <br />(SECURITY SYSTEM, TELE/DATA, AUDIO/VISUAL AND HVAC DDS CONTROL, ETC.) <br />47.LOW VOLTAGE COMMUNICATION SYSTEMS SUCH AS TELEPHONE, CABLE TV, FIRE <br />ALARM, SECURITY SYSTEMS ARE NOT PART OF THIS SCOPE OF WORK. CONTRACTOR <br />SHALL COORDINATE WITH EACH SYSTEM INSTALLER AND PROVIDE REQUIRED <br />CONDUITS WITH PULL WIRE AND 120 VOLT POWER. <br />48.ELECTRICAL CONTRACTOR IS TO COMPLY WITH THE LATEST ADA REQUIREMENTS <br />RELATED TO THE HEIGHT OF THE OUTLETS, SWITCHES AND OTHER EQUIPMENT (NOT <br />TO EXCEED 48" TO CENTER AND NOT BELOW 15" TO BOTTOM OF OUTLET BOX U.O.N.). <br />49.ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE WEATHERPROOF. ALL OUTDOOR <br />RECEPTACLES SHALL BE GFCI PROTECTED AND PROVIDED WITH EXTRA-DUTY RATED <br />"WEATHERPROOF-WHILE-IN-USE"COVER. RECEPTACLES WITHIN 6' OF SINK SHALL BE <br />GFCI TYPE RECEPTACLE. <br />50.PROVIDE ALL EQUIPMENT, MATERIAL, LABOR, SUPERVISION, COSTS, AND SERVICES <br />REQUIRED TO INSTALL COMPLETE AND WORKING SYSTEMS INCLUDING ITEMS <br />REQUIRED BUT NOT NORMALLY SHOWN, SUCH AS LAMPS, HANGERS, BRACKETS, <br />CLAMPS, COUPLINGS, BOXES, CONNECTORS AND HARDWARE EVEN THOUGH EACH <br />AND EVERY ITEM IS NOT SPECIFICALLY SPECIFIED OR SHOWN. <br />51.THE CONTRACTOR SHALL EXAMINE THE COMPLETE SET OF CONTRACT DOCUMENTS <br />FOR ALL TRADES, AS ISSUED BY THE ARCHITECT AND REVIEW DIMENSIONS, SPACE <br />REQUIREMENTS AND POINT OF CONNECTIONS TO ALL EQUIPMENT. MAKE ANY MINOR <br />ADJUSTMENTS NECESSARY TO AVOID CONFLICTS WITH THE BUILDING STRUCTURE <br />AND THE WORK OF OTHER TRADES. <br />52.REFER TO THE ARCHITECTURAL DRAWINGS FOR THE LOCATIONS OF ALL FIRE RATED <br />PARTITIONS, BUILDING EXPANSION JOINTS AND MOUNTING HEIGHTS OF EQUIPMENT. <br />53.ALL CONDUIT PENETRATIONS THROUGH WALL MUST BE SEALED, SLEEVED, AND <br />PROPERLY SUPPORTED ON EACH SIDE OF THE WALL. <br />54.COORDINATE CONDUIT ROUTE IN FIELD WITH OTHER TRADES, EQUIPMENT, AND <br />OWNER. VERIFY EXACT LOCATION AND MOUNTING HEIGHTS WITH ARCHITECT PRIOR <br />TO INSTALLATION. <br />55.THE DRAWINGS INDICATE, IN A DIAGRAMMATIC MANNER, THE DESIRED LOCATIONS <br />AND ARRANGEMENT OF THE COMPONENTS OF THE ELECTRICAL WORK. DETERMINE <br />EXACT CONDUIT ROUTING, CONDUIT BENDS, AUXILIARY JUNCTION BOXES, <br />SUPPORTS, AND UNDEFINED CONSTRUCTION DETAILS, AS A JOB CONDITION TO BE <br />INSTALLED IN ACCORDANCE WITH APPLICABLE CODE REQUIREMENTS. DO NOT <br />SCALE THE ELECTRICAL DRAWINGS FOR LOCATIONS OF ANY ELECTRICAL, <br />ARCHITECTURAL, STRUCTURAL, CIVIL, OR MECHANICAL ITEMS OR FEATURES, REFER <br />TO ARCHITECTURAL AND STRUCTURAL DIMENSIONAL DRAWINGS. <br />56.ALL CONDUCTORS SHALL BE COPPER TYPE THWN INSULATION. <br />57.FOR EQUIPMENT REQUIRING SPECIAL RECEPTACLE, PROVIDE RECEPTACLE WITH <br />NEMA CONFIGURATION TO MATCH EQUIPMENT PLUG. VERIFY WITH EQUIPMENT <br />MANUFACTURER. <br />58.WHERE MULTI-HOMERUNS ARE INDICATED ON DRAWINGS INDICATING THE SAME <br />PANEL BOARD CIRCUIT NUMBER, PROVIDE JUNCTION BOX ABOVE ACCESSIBLE <br />CEILING AND ROUTE ONE SET OF WIRES TO CIRCUIT BREAKERS. <br />59.ALL GROUNDING ELECTRODES THAT ARE PRESENT AT EACH BUILDING OR <br />STRUCTURE SHALL BE BONDED TOGETHER. <br />60.FOR SMALL AC MOTORS NOT HAVING BUILT-IN THERMAL OVERLOAD PROTECTION, <br />PROVIDE MANUAL MOTOR STARTERS WITH OVERLOAD HEATER ELEMENTS SIZED TO <br />THE NAMEPLATE CURRENT RATING OF THE MOTOR. SMALL AC MOTORS WITH <br />BUILT-IN THERMAL OVERLOAD PROTECTION, PROVIDE ELEMENTS SIZED TO THE <br />NAMEPLATE CURRENT RATING OF THE MOTOR. SMALL AC MOTORS WITH BUILT-IN <br />THERMAL OVERLOAD PROTECTION, PROVIDE A HORSEPOWER RATED TOGGLE TYPE <br />DISCONNECT SWITCH. <br />61.ALL PANELBOARDS SHALL BE MARKED WITH IDENTIFYING NAMEPLATES TO INDICATE <br />THE DESIGNATIONS USED ON THESE DRAWINGS. PROVIDE NEW TYPEWRITTEN <br />PANELBOARD SCHEDULE, CORRECTLY FILLED OUT BASED ON FINAL AS-BUILT <br />RECORD DRAWING CONDITION, FOR EVERY PANELBOARD. <br />62.OUTLETS SHALL BE INSTALLED AT 15" TO BOTTOM ABOVE FINISHED FLOOR, UNLESS <br />OTHERWISE NOTED ON THE ARCHITECTURAL DRAWINGS OR LOCATED AT MILLWORK. <br />VERIFY EXACT MOUNTING HEIGHT OF ALL OUTLETS WITH ARCHITECT PRIOR TO <br />INSTALLATION. <br />63.VERIFY THE EXACT LOCATION OF MECHANICAL AND PLUMBING EQUIPMENT AND <br />OTHER EQUIPMENT REQUIRING ELECTRICAL CONNECTION, PRIOR TO ROUGH IN. <br />REFER TO MECHANICAL AND PLUMBING DRAWINGS. WHERE INDICTED ON <br />MECHANICAL AND PLUMBING DRAWINGS AS PART OF THE DRAWING PACKAGE AND <br />NOT COVERED IN THIS PLAN, PROVIDE NECESSARY POWER, CONDUIT AND CONTROL <br />WIRING (IF LOW VOLTAGE, PROVIDE TRANSFORMERS AS REQUIRED) INCLUDING <br />CONDUIT AND CONTROL WIRING BETWEEN INDOOR AND OUTDOOR UNITS. <br />COORDINATE EXACT POWER REQUIREMENTS INCLUDING BREAKER, DISCONNECT <br />AND FEEDER SIZES WITH EQUIPMENT SUBMITTALS PRIOR TO INSTALLATION. <br />64.VERIFY ACTUAL MOTOR AND APPLIANCE RATINGS AND LOADS WITH EQUIPMENT <br />SUBMITTALS AND EQUIPMENT MANUFACTURER IN ORDER TO PROVIDE CORRECTLY <br />SIZED BREAKERS, FEEDERS, DISCONNECTS AND OUTLETS. SUBMIT TO ARCHITECT <br />ANY NECESSARY REVISIONS NECESSARY PRIOR TO INSTALLATION. ALL CHANGES <br />SHALL BE SHOWN ON RECORD DRAWINGS. <br />65.ELECTRICAL OUTLETS AND LIGHTING CIRCUITS SHALL BE PROPERLY IDENTIFIED. <br />OUTLETS SHALL BE LABELED ON BACKSIDE OF COVER-PLATES WITH THE <br />ELECTRICAL, PANEL/CIRCUIT SUPPLYING THE OUTLETS. CIRCUITS IN CONDUITS <br />SHALL BE IDENTIFIED BY CIRCUIT NUMBER, VOLTAGE AND PANEL. <br />66.PROVIDE FIRE RATED BOX FOR ALL RECESSED JUNCTION BOXES AND PANELS <br />LOCATED IN FIRE RATED WALLS AND CEILINGS. REFER TO ARCHITECTURAL <br />DRAWINGS FOR EXACT LOCATION OF FIRE RATED WALLS AND CEILINGS. <br />NO.TITLE SCALE <br />E0.01 GENERAL NOTES SHEET INDEX AND SYMBOLS LIST NO SCALE <br />E0.02 ELECTRICAL SPECIFICATIONS NO SCALE <br />E0.03 TITLE 24 INDOOR NO SCALE <br />E0.04 TITLE 24 OUTDOOR NO SCALE <br />E2.01 SINGLE LINE DIAGRAM NO SCALE <br />E4.01 ELECTRICAL SITE PLAN NO SCALE <br />E5.01 POWER PLAN 1/16" = 1'-0" <br />E5.02 MECHANICAL POWER PLAN 1/4" = 1'-0" <br />E5.03 ROOF POWER PLAN 1/4" = 1'-0" <br />E6.01 LIGHTING PLAN 1/4" = 1'-0" <br />E7.01 EGRESS PHOTOMETRIC CALCULATIONS 1/4" = 1'-0" <br />E7.01 EGRESS PHOTOMETRIC CALCULATIONS 1/4" = 1'-0" <br />POWER OUTLETS <br />FLOOR WALL CEILING <br />DUPLEX <br />QUADRUPLEX <br />DUPLEX - VOICE - DATA <br />GFCI DUPLEX <br />SIMPLEX <br />EMERGENCY DUPLEX <br />EMERGENCY QUADRUPLEX <br />EMERGENCY SIMPLEX <br />DUPLEX-VOICE <br />DUPLEX-DATA <br />QUAD-VOICE <br />QUAD-VOICE-DATA <br />QUAD-DATA <br />JUNCTION BOX <br />POKE THRU <br />SPLIT WIRE <br />SPECIAL OUTLET <br />MULTI OUTLET SURFACE <br />RACEWAY <br />WIRING <br />3/4" CONDUIT WITH 2#12 WIRES, UON. <br />GROUND WIRE NOT SHOWN. <br />3/4" CONDUIT WITH 3#12 WIRES, UON. <br />GROUND WIRE NOT SHOWN. <br />3/4" CONDUIT WITH 4#12 WIRES, UON. <br />GROUND WIRE NOT SHOWN. <br />CONDUIT HOMERUN TO PANEL BOARD 1LA <br />WITH CIRCUIT 1,3,5 <br />CAPPED CONDUIT <br />CONDUIT RUN UNDERGROUND OR UNDER <br />THE FLOOR SLAB <br />CONDUIT TURNING DOWN <br />CONDUIT TURNING UP <br />CONDUIT BREAK <br />LIGHTING <br />FLOOR WALL CEILING <br />RECESSED DOWNLIGHT <br />1X4 SURFACE MOUNTED LIGHT <br />2X4 SURFACE MOUNTED LIGHT <br />4FT WALL MOUNTED LIGHT <br />1X4 EMERGENCY LIGHT <br />2X4 EMERGENCY LIGHT <br />2X4 RECESSED LIGHT <br />EXIT SIGN 1 FACE <br />EXIT SIGN 1 FACE LEFT <br />ARROW <br />ANNOTATION <br />TITLE MARK DETAIL OR PLAN <br />NUMBER - 1 <br />DETAIL OR PLAN REFE <br />LOCATION FOUND IN E-201 <br />DETAIL REFERENCE <br />DETAIL NUMBER - 1 <br />DETAIL FOUND IN E-501 <br />SECTION MARK A2T <br />SECTION NUMBER - 1 SECTION <br />FOUND IN E-501 <br />SHEET KEYNOTE <br />REVISION CLOUD (DELTA 1) <br />DETAIL <br />BOUNDARY B <br />DETAIL NUMBER - 2 <br />LP4:12 PANEL:CIRCUIT <br />A1 <br />LP4:12 <br />LIGHTING FIXTURE TYPE <br />PANEL:CIRCUIT <br />SWITCHES/CONTROLS <br />FLOOR WALL CEILING <br />LIGHT SWITCH - TIME <br />OPERATED <br />LIGHT SWITCH - SINGLE POLE <br />SUBSCRIPT INDICATES <br />CONTROLLING SWITCH LEG. <br />LIGHT SWITCH - THREE WAY <br />LIGHT SWITCH - KEY <br />OPERATED <br />LIGHT SWITCH - WITH PILOT <br />LIGHT <br />SWITCH - WITH THERMAL <br />OVERLOAD <br />DIMMER SWITCH <br />SUBSCRIPT INDICATES <br />CONTROLLING SWITCH LEG. <br />VACANCY SENSOR SWITCH <br />SUBSCRIPT INDICATES <br />CONTROLLING SWITCH LEG. <br />OCCUPANCY SENSOR <br />PHOTOCELL <br />OCCUPANCY SENSOR POWER <br />PACK <br />OVERRIDE SWITCH <br />POWER <br />DISTRIBUTION BOARD <br />480/277V OR 208/120V <br />RECESSED PANEL <br />480/277V OR 208/120V <br />SURFACE MOUNTED PANEL <br />TRANSFORMER <br />DISCONNECT SWITCH <br />SWITCH - MOTOR RATED <br />FUSED DISCONNECT SWITCH <br />MAGNETIC MOTOR STARTER - <br />NEMA SIZE 1 INDICATED <br />STARTER - DISCONNECT <br />SWITCH <br />MOTOR <br />VARIABLE FREQUENCY DRIVE <br />PULL BOX <br />MANHOLE <br />FIRE ALARM DEVICES <br />CARBON MONOXIDE SENSOR <br />SMOKE DETECTOR <br />COMBINATION SMOKE <br />DETECTOR AND CARBON <br />MONOXIDE SENSOR <br />SINGLE LINE DIAGRAM <br />CIRCUIT BREAKER SWITCH <br />SWITCHGEAR BUSWAY <br />GROUND FAULT RELAY <br />DIGITAL METER U.O.N. <br />TRANSFORMER - DELTA <br />WYE-GROUNDED <br />GENERATOR <br />PANEL <br />2000 = AMPACITY <br />3-NO, 4-SINGLE, 5-DOUBLE = <br />NEUTRAL <br />(+) = ADDITIONAL INFO AS <br />REQUIRED <br />J J J <br />A <br />1LA-1,3,5 <br />OS OS <br />PC <br />PP <br />OR <br />T <br />M <br />PB <br />MH <br />GFR <br />M <br />G <br />XXXXX <br />XXXXX <br />XXXXX <br />XXXXX <br />2000-5+ <br />CO <br />SD <br />SC <br />FIRE ALARM NOTES <br />1.THE CONTRACTOR (LIFE SAFETY VENDOR) SHALL BE RESPONSIBLE FOR SUBMITTING COMPLETE FIRE ALARM <br />PLANS, REQUIRED CONNECTION DIAGRAMS, WIRING DIAGRAMS, BATTERY CALCULATIONS AND WORST CASE <br />VOLTAGE DROP CALCULATIONS TO THE CITY FIRE DEPARTMENT FOR REVIEW AND OBTAIN APPROVAL FROM THE <br />CITY PRIOR TO INSTALLING THE SYSTEM. <br />2.AN APPROVED MANUAL AND AUTOMATIC FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH CFC, <br />SECTION 907 AND CALIFORNIA BUILDING CODE. <br />3.VARIANCE FOR THE FIRE ALARM SYSTEM SHALL BE SEPARATE. ELECTRICAL CONTRACTOR TO PAY SEPARATE <br />FEE FOR VARIANCE/MODIFICATION UPON PLAN CHECK RESUBMITTAL. <br />ELECTRICAL PRE-DEMOLITION NOTES <br />1.PRIOR TO COMMENCEMENT OF DEMOLITION WORK, CONTRACTOR SHALL UNDERTAKE ELECTRICAL SURVEY TO <br />TRACE ALL EXISTING BRANCH CIRCUITS/FEEDERS. CONTRACTOR SHALL CLEARLY IDENTIFY ALL <br />CIRCUITS/FEEDERS THAT SERVE EXISTING TO REMAIN DEVICES/EQUIPMENT/FIXTURES/ETC. WITHIN OR OUTSIDE <br />THE DEMISED AREA TO BE DEMOLISHED. THIS SHALL INCLUDE CIRCUITS THAT PASS THROUGH AND/OR FEED THE <br />SPACE AND EXTEND OUTSIDE THE DEMISED AREA ON AND OFF THE FLOOR (E.G. ABOVE AND BELOW). <br />2.EXISTING TO REMAIN CIRCUITS WILL BE CLEARLY IDENTIFIED AT THE RESPECTIVE ELECTRICAL PANEL AS "TO <br />REMAIN" WITH THE LOAD SERVED INDICATED. A SCHEDULE FOR EACH PANEL THE ACTIVE LOADS FEEDING <br />OUTSIDE THE DEMISED PREMISES SHALL BE FURNISHED TO CLIENT/ENGINEER PRIOR TO COMMENCEMENT OF <br />DEMOLITION (SEE NOTE 5). <br />3.THE ASSOCIATED CONDUIT FOR EXISTING TO REMAIN ACTIVE CIRCUITS SHALL BE CLEARLY IDENTIFIED IN THE <br />ELECTRICAL CLOSET AND FOR A MINIMUM OF 24" OUTSIDE THE ELECTRICAL CLOSET PRIOR TO ANY DEMOLITION <br />WORK. AFTER CEILING DEMO, THE ENTIRE LENGTH OF THE CIRCUIT CONDUIT SHALL BE CLEARLY MARKED. <br />4.THE METHOD OF INDICATING EXISTING TO REMAIN DEVICES/CIRCUITS/WIREWAYS, ETC. SHALL BE AGREED <br />BETWEEN LL/CLIENT REPRESENTATIVE/EC AND DEMOLITION CONTRACTOR, PRIOR TO COMMENCEMENT OF <br />DEMO. <br />5.THE EC SHALL BE RESPONSIBLE TO INDICATE ALL CIRCUITS TO REMAIN ON AN EXISTING FLOOR PLAN, (PROVIDED <br />BY ARCHITECT/CLIENT REP). THE MARK-UP SHALL INDICATE POINT OF ORIGIN (EG. PANEL), CONDUIT ROUTE AND <br />LOAD SERVED. <br />DEMOLITION NOTES <br />1.PRIOR TO SUBMISSION OF THE BID, THIS CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL <br />EXISTING CONDITIONS TO DETERMINE THEIR IMPACT ON THE EXECUTION OF WORK IN THIS CONTRACT. <br />2.THE DEMOLITION WORK SHALL INCLUDE, BUT NOT BE LIMITED TO, ANY AND ALL MATERIALS, CONNECTIONS, <br />EXTENSIONS, CUTTING, REPAIRING AND OTHER ELECTRICAL WORK, TEMPORARY OR PERMANENT, THAT MAY BE <br />REQUIRED TO MAINTAIN SERVICE THROUGH THE COMPLETION OF THIS PROJECT. COORDINATE THE EXTENT OF <br />THE DEMOLITION WORK WITH THE ARCHITECT. <br />3.EXISTING FEEDERS AND BRANCH CIRCUITING PASSING THROUGH THE AREA OF DEMOLITION AND SERVING <br />OCCUPIED ADJACENT AREAS AND/OR INTERFERING WITH THE NEW WORK SHALL BE TRACED AND RELOCATED BY <br />THIS CONTRACTOR. ALL NECESSARY SHUTDOWNS REQUIRED TO PERFORM THIS WORK SHALL BE COORDINATED <br />WITH THE BUILDING MANAGEMENT. <br />4.WIRING, CONDUITS, AND SUPPORTS FOR FEEDERS AND BRANCH CIRCUITING SHALL BE REMOVED TO THEIR <br />PANEL OF ORIGIN. <br />5.MAINTAIN THE CONTINUITY OF EXISTING BRANCH CIRCUITING SERVING REMAINING ELECTRICAL DEVICES <br />OUTSIDE THE SCOPE OF WORK WHERE PORTIONS OF EXISTING BRANCH CIRCUITING ARE BEING REMOVED. <br />6.IDENTIFY AS SPARE ANY PROTECTIVE DEVICE IN EXISTING PANELS THAT ARE MADE SPARE DUE TO DEMOLITION. <br />PANEL DIRECTORIES SHALL BE UPDATED ACCORDINGLY. <br />7.UNLESS OTHERWISE NOTED, REMOVE ALL POWER AND COMMUNICATIONS OUTLETS AND DEVICES COMPLETE <br />WITH WIRING, RACEWAYS AND BACK BOXES IN AREA OF DEMOLITION. <br />8.ALL LIGHTING FIXTURES, SWITCHES AND ASSOCIATED WIRING AND CONDUIT IN AREA OF DEMOLITION SHALL BE <br />REMOVED UNLESS OTHERWISE NOTED. <br />9.EXISTING BASE BUILDING FIRE ALARM SYSTEM DEVICES ARE TO REMAIN AND KEPT OPERATIONAL DURING ALL <br />STAGES OF THE PROJECT. ALL DEVICES SHALL BE PROPERLY PROTECTED. <br />POWER NOTES <br />1.REFER TO ARCHITECTURAL DRAWINGS FOR THE EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL DEVICES <br />(I.E. RECEPTACLES, DATA/TELEPHONE OUTLETS, SECURITY DEVICES, PANELS, SPEAKER/STROBE, ETC. <br />2.ELECTRICAL CONTRACTOR SHALL MAINTAIN THE CONTINUITY OF CIRCUITING IN AREAS WHICH ARE CONNECTED <br />TO EXISTING ELECTRICAL DEVICES AND ELECTRICAL SERVICES STILL IN USE. <br />3.PROVIDE TIE BARS ON ALL SINGLE POLE CIRCUIT BREAKERS SERVING MULTI-WIRE BRANCH CIRCUITS IN <br />COMPLIANCE WITH CEC ARTICLE 210.4(B). EXISTING CIRCUIT BREAKERS REQUIRING TIE HANDLES SHALL BE <br />REPLACED WITH NEW TRIP FREE HANDLE BREAKERS. NEW BREAKERS SHALL MATCH BASE BUILDING <br />STANDARDS, SHALL BE FROM SAME MANUFACTURER OF EXISTING BREAKERS THAT ARE TO REMAIN IN PANEL, <br />AND SHALL BE COMPATIBLE WITH PANELBOARD. CONTRACTOR SHALL COORDINATE REQUIREMENTS IN FIELD <br />WITH EXISTING EQUIPMENT. <br />4.ALL TELEPHONE/DATA CONDUIT STUB-UPS, WHERE GYPBOARD CEILINGS OCCUR, SHALL RUN INTO ACCESSIBLE <br />CEILING AREAS. <br />5.ALL MECHANICAL EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THE HVAC CONTRACTOR, WIRED BY THE <br />ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL WIRE MECHANICAL EQUIPMENT AS PER AN <br />APPROVED MANUFACTURER'S WIRING DIAGRAM. ALL CONTROL WIRING BY THE HVAC CONTRACTOR. <br />6.CONTRACTOR SHALL PROVIDE DISCONNECT SWITCHES FOR ALL MECHANICAL EQUIPMENT THAT IS NOT <br />FACTORY SUPPLIED UNLESS OTHERWISE NOTED ON MECHANICAL DRAWINGS. CONTRACTOR SHALL <br />COORDINATE SIZE WITH MECHANICAL EQUIPMENT SPECIFICATIONS AND MECHANICAL CONTRACTOR. <br />LIGHTING NOTES <br />1.REFER TO ARCHITECTURAL DRAWINGS FOR THE EXACT LOCATION, QUANTITIES, TYPES, AND MOUNTING HEIGHTS <br />OF LIGHT FIXTURES, EXIT SIGNS, SWITCHES, DIMMERS, ETC. <br />2.PRIOR TO ORDERING LIGHTING FIXTURES, COORDINATE WITH ARCHITECTURAL AND ENGINEERING INFORMATION, <br />OBTAIN CLARIFICATION OF ANY QUESTIONS PRIOR TO PROCEEDING. <br />3.ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL NEW LIGHT FIXTURES AS INDICATED AND INSTALL <br />NEW SWITCHES, DIMMERS, ETC. FOR CONTROL OF LIGHT FIXTURES AS SHOWN ON ARCHITECTURAL DRAWINGS. <br />VERIFY AND COORDINATE SWITCHING CONTROL WITH ARCHITECT/CLIENT REPRESENTATIVES. <br />4.ALL JUNCTION OR OUTLET BOXES SHALL BE ACCESSIBLE. WHERE UNOBSTRUCTED ACCESS TO A BOX OR <br />OUTLET IS NOT POSSIBLE, PROVIDE ACCESS PANEL. COORDINATE WITH THE ARCHITECT AND OBTAIN APPROVAL <br />FROM ARCHITECT PRIOR TO INSTALLATION OF JUNCTION OR OUTLET BOXES. <br />5.WHERE MULTIPLE SWITCHES ARE GROUPED TOGETHER AT ONE LOCATION, THEY SHALL BE MOUNTED IN A <br />SINGLE OUTLET BOX WITH A COMMON FACEPLATE. BUTTED OUTLET BOXES AND SWITCHPLATES ARE NOT <br />PERMITTED. PROVIDE DIVIDER FOR SEPARATION OF SERVICE. <br />6.SUPPORT CEILING MOUNTED FIXTURES DIRECTLY FROM THE BUILDING STRUCTURE. DO NOT SUPPORT <br />FIXTURES FROM PIPING, EQUIPMENT, OR SOLELY FROM THE SUSPENDED CEILING. <br />SHEET <br />PA / PM: <br />JOB NO.: <br />DRAWN BY: <br />CAUTION: 24"x36" <br />RE <br />M <br />A <br />R <br />K <br />S <br />DA <br />T <br />E <br />de <br />b <br />s <br />@ <br />s <br />h <br />p <br />a <br />r <br />t <br />n <br />e <br />r <br />s <br />. <br />n <br />e <br />t <br />ma <br />r <br />c <br />o <br />h <br />@ <br />s <br />h <br />p <br />a <br />r <br />t <br />n <br />e <br />r <br />s <br />. <br />n <br />e <br />t <br />(7 <br />1 <br />4 <br />) <br />3 <br />9 <br />0 <br />. <br />8 <br />6 <br />0 <br />0 <br />ar <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />n <br />i <br />n <br />g <br />PA <br />R <br />T <br />N <br />E <br />R <br />S <br />ww <br />w <br />. <br />s <br />h <br />p <br />a <br />r <br />t <br />n <br />e <br />r <br />s <br />. <br />n <br />e <br />t <br />07 <br />- <br />0 <br />3 <br />- <br />2 <br />0 <br />2 <br />4 <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />UN <br />I <br />T <br />E <br />D <br /> <br />M <br />E <br />D <br />I <br />C <br />A <br />L <br /> <br />I <br />M <br />A <br />G <br />I <br />N <br />G <br /> <br />H <br />E <br />A <br />L <br />T <br />H <br />C <br />A <br />R <br />E <br />80 <br />0 <br /> <br />N <br />. <br /> <br />T <br />U <br />S <br />T <br />I <br />N <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />TE <br />N <br />A <br />N <br />T <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br /> <br />F <br />O <br />R <br />: <br />Un <br />i <br />t <br />e <br />d <br /> <br />M <br />e <br />d <br />i <br />c <br />a <br />l <br /> <br />I <br />m <br />a <br />g <br />i <br />n <br />g <br /> <br />H <br />e <br />a <br />l <br />t <br />h <br />c <br />a <br />r <br />e <br />SU <br />I <br />T <br />E <br /> <br />- <br /> <br />H <br />Mechanical . Electrical . Plumbing <br />225 E Broadway, Suite 101A <br />Glendale, CA 91205 <br /># 213.820.3683 <br />Hestrada@elogicsce.com <br />10 <br />- <br />2 <br />8 <br />- <br />2 <br />0 <br />2 <br />4 <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />GE <br />N <br />E <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S <br /> <br />S <br />H <br />E <br />E <br />T <br /> <br />I <br />N <br />D <br />E <br />X <br />AN <br />D <br /> <br />S <br />Y <br />M <br />B <br />O <br />L <br />S <br /> <br />L <br />I <br />S <br />T <br />E0.01 <br />1 <br />1 <br />SA <br />URABH JAGD ISH PANDY <br />AREG <br />I <br />STERED PROF E SS IONAL ENGI <br />N <br />EER <br />ELECTRICALSTATE OF CALIFORNIA <br />E-23194 <br />EXP. 6-30- 46 <br />1 <br />di <br />g <br />i <br />t <br />a <br />l <br /> <br />s <br />t <br />a <br />m <br />p <br /> <br />a <br />n <br />d <br /> <br />s <br />i <br />g <br />n <br />a <br />t <br />u <br />r <br />e <br />, <br /> <br />d <br />a <br />t <br />e <br /> <br />1 <br />1 <br />- <br />1 <br />3 <br />- <br />2 <br />0 <br />2 <br />4 <br />800 N Tustin Ave Unit <br />#H1/23/2025