Laserfiche WebLink
W/H <br />W D <br />45 <br />' <br />- <br />0 <br />" <br />3'-0" <br />5'-8" <br />6' <br />- <br />5 <br />" <br />3'-6" <br />22 <br />' <br />- <br />1 <br />0 <br />" <br />(E) DETACHED <br />GARAGE <br />(E <br />) <br /> <br />D <br />R <br />I <br />V <br />E <br />W <br />A <br />Y <br />(E) WALKWAY <br />(E) LAWN <br />(E) LAWN <br />47' <br />47' <br />13 <br />7 <br />' <br />13 <br />7 <br />' <br />ROOSEVELT AVE <br />T-1 <br />. <br />SITE PLAN <br />SCALE: 1" = 10'-0" <br />2022 CBC - CALIFORNIA BUILDING CODE <br />2022 CPC - CALIFORNIA PLUMBING CODE <br />2022 CMC - CALIFORNIA MECHANICAL CODE <br />2022 CEC - CALIFORNIA ELECTRIC CODE <br />2022 CRC - CALIFORNIA RESIDENTIAL CODE <br />2022 T-24 - ENERGY STANDARDS <br />2022 -GREEN BUILDING CODE <br />CURRENT CODES <br />SHEET INDEX <br />(1) T-1 TITLE SHEET/ PLOT PLAN <br />(2) T-2 NOTES <br />(3) T-3 GREEN BUILDING NOTES <br />(4) T-4 GREEN BUILDING NOTES <br />(5) A-1 (E) + (N) FLOOR PLAN <br />(6) A-2 ELEVATIONS, SECTIONS <br />(7) S-1 FOUNDATION, FRAMING <br />(8) D-1 DETAILS <br />(9) T-24A TITLE 24 <br />(10) T-24B TITLE 24 <br />TYPE OF CONSTRUCTION <br />OCCUPANCY <br />NUMBER OF STORIES <br />AUTOMATIC FIRE SPRINKLERS <br />TOTAL LOT AREA <br />V-B <br />R-3/U <br />1 <br />NO <br />6,439 SQ. FT. <br />LOT DESCRIPTION: <br />LOT - <br />BLOCK - <br />TRACT ---- <br />MAP BOOK - <br />CITY SANTA ANA <br />COUNTY ORANGE <br />STATE CALIFORNIA <br />A.P.N. 099-212-03 <br />BUILDING SUMMARY <br />(E) LIVING AREA 1,184 SQ. FT. <br /> SCOPE OF WORK: <br />1. REPLACE ROOFING MATERIAL OVER THE <br />ENTIRE HOUSE. <br />2. REPLACE FIRE DAMAGED ROOF FRAMING <br />PER PLAN. <br />3. REPLACE HVAC SYSTEM PER PLAN. <br />4. REPLACE ELECTRICAL WIRING AND FIXTURES <br />PER PLAN. <br />5. REPLACE DRYWALL AND INSULATION PER <br />PLAN. <br />6. REPLACE WINDOWS PER PLAN. <br />7. REPAIR/REPLACE STUCCO TO MATCH <br />EXISTING. <br />8. REMOVE WALL @ KITCHEN PER PLAN. <br />9. REMOVE WALLS BETWEEN BATHROOM AND <br />BEDROOM #2 TO ENLARGE THE BATHROOM <br />AND TO CONVERT BEDROOM #2 INTO A <br />LAUNDRY. (SEE PLANS) <br />10. KITCHEN REMODEL. <br />GENERAL REQUIREMENTS: <br />1. NO CHANGES ARE TO BE MADE TO THESE PLANS WITHOUT THE KNOWLEDGE AND WRITTEN <br />CONSENT OF THE ENGINEER. <br />2. ALL DIMENSIONS CONTROLLED BY EXISTING CONDITIONS SHALL BE VERIFIED BY THE <br />CONTRACTOR AT THE SITE. <br />3. CONSTRUCTIONS AND MATERIALS SHALL COMPLY WITH AND BE INSTALLED IN <br />ACCORDANCE WITH ALL THE REQUIREMENTS OF ALL LEGALLY CONSTITUTED PUBLIC <br />AUTHORITIES HAVING JURISDICTION, INCLUDING ALL COUNTY AND LOCAL ORDINANCES, <br />AND THE SAFETY ORDERS OF THE STATE INDUSTRIAL ACCIDENT COMMISSION, OSHA. <br />4. GENERAL CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY ALL GRADES, DIMENSIONS, <br />AND CONDITIONS PRIOR TO BIDDING AND COMMENCING CONSTRUCTION. <br />5. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK, <br />INCLUDING THAT OF ALL SUB-TRADES. <br />6. GENERAL CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY OF ANY DISCREPANCIES <br />FOUND WITHIN THE CONTRACT DOCUMENTS. <br />7. ALL WORK PERFORMED SHALL CONFORM WITH THE REQUIREMENTS OF THE CALIFORNIA <br />BUILDING CODE (LATEST ADOPTED EDITION) OR OTHER APPLICABLE GOVERNING CODES <br />AND/OR LOCAL BUILDING ORDINANCES. <br />8. ALL SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR REMOVAL OF ALL DEBRIS <br />ACCUMULATED AS A RESULT OF THEIR OPERATION. ALL SCRAP, DEBRIS, AND OTHER <br />EXCESS MATERIAL SHALL BE REMOVED FROM THE BUILDING SITE. <br />9. THE OWNER SHALL HAVE THE RIGHT TO MAKE CERTAIN CHANGES IN THE WORK AND THE <br />CONTRACT AMOUNT SHALL BE ADJUSTED ACCORDINGLY. HOWEVER, THE GENERAL <br />CONTRACTOR SHALL NOT PROCEED WITH ANY CHANCES WITHOUT THE WRITTEN <br />APPROVAL OF THE OWNER. <br />10. ALL MATERIALS SHALL BE FURNISHED AS SHOWN HEREIN UNLESS EQUAL ALTERNATES ARE <br />APPROVED IN WRITING BY THE OWNER. <br />11. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING AND PROVIDING BRACING <br />DURING CONSTRUCTION AND/OR ERECTION TO SUPPORT ALL LOADS TO WHICH THE <br />STRUCTURE MAY BE SUBJECTED. <br />12. SEE PLANS AND SPECIFICATIONS BY OTHERS FOR ADDITIONAL REQUIREMENTS IF <br />APPLICABLE. <br />13. TRUSSES SHALL BE APPROVED BY THE BUILDING DEPARTMENT, FIELD MEASURED BY <br />MANUFACTURER PRIOR TO FABRICATION AND INSTALLATION. <br />14. ANY REFERENCE TO THE WORDS APPROVE, APPROVED, OR APPROVAL IN THESE <br />DOCUMENTS SHALL BE HERE DEFINED TO MEAN GENERAL ACCEPTANCE OR REVIEW AND <br />SHALL NOT RELIEVE THE CONTRACTOR AND/OR HIS SUB-CONTRACTORS OF ANY LIABILITY <br />IN FURNISHING THE REQUIRED MATERIALS OR LABOR SPECIFIED. <br />15. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE <br />AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL <br />SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR <br />CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, <br />INCLUDING, BUT NOT LIMITED TO BRACING AND SHORING, OBSERVATION VISITS TO THE <br />SITE BY FIELD REPRESENTATIVES OF THE ENGINEER SHALL NOT INCLUDE INSPECTION OF <br />THE PROTECTIVE MEASURES OR THE CONSTRUCTION PROCEDURES. ANY SUPPORT <br />SERVICES PERFORMED BY THE ENGINEER DURING THE CONSTRUCTION SHALL BE <br />DISTINGUISHED FROM CONTINUOUS AND DETAILED INSPECTION SERVICES WHICH ARE <br />FURNISHED BY OTHERS. THESE SUPPORT SERVICES PERFORMED BY THE ENGINEER, <br />WHETHER OF MATERIAL OR WORK, AND FOR THE PROPOSE OF ASSISTING IN QUALITY <br />CONTROL AND IN ACHIEVING CONFORMANCE WITH CONTRACT DOCUMENTS, DO NOT <br />GUARANTEE CONTRACTOR'S PERFORMANCE AND SHALL NOT BE CONSTRUED AS <br />SUPERVISION OF CONSTRUCTION. <br />16. THE SHOP DRAWINGS REVIEW PROCESS BY THIS ENGINEER WILL ONLY COMMENCE AFTER <br />THE SUBMITTED FABRICATION OR SHOP DRAWINGS HAVE BEEN AS FOLLOWS: <br />A. INITIALLY REVIEWED AND ACCEPTED AS CONFORMING WITH THE STRUCTURAL <br /> CONSTRUCTION DRAWINGS BY THE RESPONSIBLE SUPERVISOR AND DRAWING <br /> CHECKER WITH THEIR SIGNATURES. <br />B. APPROVED AND ACCEPTED WITH A STAMP FROM THE GENERAL CONTRACTOR AS <br /> CONFORMING TO THE CONSTRUCTION DOCUMENTS. <br />FRAMING LUMBER: <br />1. ALL FRAMING LUMBER SHALL CONFORM TO "STANDARD GRADING AND DRESSING RULES <br />NO.17 OF THE WEST COAST LUMBER INSPECTION BUREAU AND DOC PS-20. EACH PIECE <br />SHALL BEAR THE GRADE STAMP OF AN APPROVED GRADING AGENCY, EXCEPT EXPOSED <br />LUMBER SHALL BEAR NO MARKINGS WHICH WILL BE VISIBLE AFTER INSTALLATION. <br />2. FRAMING LUMBER SHALL BE DOUGLAS FIR (LARCH), COMMON NAILS, UNLESS OTHERWISE <br />NOTED. THE FOLLOWING GRADES SHALL BE THE MINIMUM ACCEPTABLE GRADES, UNLESS <br />OTHERWISE NOTED: <br />ITEM: <br />A. STUDS: <br />· 2" THICK, 4" WIDE (STUD HT. = 8'-1" MAX.) NO.2 OR BETTER <br />· 2" THICK, 4" TO 8" WIDE NO.1 <br />B. STRUCTURAL LIGHT FRAMING: <br />· 2" TO 4" THICK, 2" TO 4" WIDE NO.2 <br />C. STRUCTURAL JOISTS AND PLANKS: <br />· 2" TO 4" THICK, 6" AND WIDER NO.2 <br />D. BEAMS AND STRINGERS: <br />· 5" AND THICKER, 6" AND WIDER NO.2 <br />E. POSTS AND TIMBERS: <br />· 5" X 5" AND LARGER NO.1 <br />3. MAXIMUM STUD HEIGHT SCHEDULE AND NON-BEARING WALLS (LATERALLY UNSUPPORTED <br />HEIGHT): <br />·2X4 @ 16" O.C. 11'-0" U.O.N. <br />·2X6 @ 16" O.C. 16'-0" U.O.N. <br />·2 X 8 @ 16" O.C. 20'-0" U.O.N. <br />4. PLYWOOD SHALL CONFORM TO PRODUCT STANDARD DOC PS-1 OR PS-2. PLYWOOD SHALL <br />BE APA GRADE STAMPED, INCLUDING PANEL INDEX NUMBER. ROOF SHEATHING SHALL CDX <br />OR OSB, UNLESS OTHERWISE NOTED. SEE SHEAR WALL SCHEDULE FOR SHEAR PANEL <br />SHEATHING. ROOF AND FLOOR SHEATHING AND SHEAR WALL PANELS SHALL BE IN <br />PLACE AND INSPECTED BY THE BUILDING OFFICIAL PRIOR TO COVERING. INSTALL WITH <br />FACE GRAIN ACROSS SUPPORTS EXCEPT WHERE NOTED ON PLANS. <br />5. ALL OPENINGS THROUGH ROOF SHALL BE NAILED PER BOUNDARY NAILING OF PLYWOOD <br />DIAPHRAGM NAILING REQUIREMENTS. <br />6. ALL GLUE LAMINATED MEMBERS AS SHOWN ON PLANS SHALL BE IN ACCORDANCE WITH <br />A.I.T.C. SPECIFICATIONS. ADHESIVE SHALL BE WATER REGISTRANT INTERIOR W.C.L.A. <br />SPECIFICATION COMBINATION (SEE BELOW) INDUSTRIAL APPEARANCE GRADE. A.I.T.C. <br />INSPECTION CERTIFICATES SHALL BE FURNISHED WITH EACH BEAM. SUBMIT SHOP <br />DRAWINGS TO THIS ENGINEER FOR REVIEW PRIOR TO FABRICATION. <br />· SIMPLE SPAN BEAMS DF/DF 24F-V4 <br />· CANTILEVERED BEAMS DF/DF 24F-V8 <br />7. FRAMING HARDWARE SHALL BE SIMPSON 'STRONG-TIE' CONNECTORS OR <br />EQUAL. ALL SUBSTITUTES SHALL BEAR I.C.C. APPROVAL, UNLESS OTHERWISE INDICATED <br />ON DRAWINGS. ALL FLUSH WOOD TO WOOD CONNECTORS SHALL BE MADE WITH SIMPSON <br />METAL HANGERS AS FOLLOWS: <br />· 2 X 4, 6 & 8 MEMBERS 'U' SERIES <br />· 2 X 10, 12 & 16 MEMBERS 'HUS' SERIES <br />· 4 X & LARGER 'HU' SERIES <br />8. ALL BOLTS THROUGH WOOD SHALL HAVE STANDARD WASHERS EXCEPT WHERE METAL <br />SIDE PLATES ARE SPECIFIED. BOLT HOLES SHALL BE NOT MORE THAN 1/16" LARGER THAN <br />THE BOLT DIAMETER, UNLESS OTHERWISE NOTED. <br />9. SILL PLATES SHALL BE BOLTED TO FOUNDATION WITH MINIMUM 5/8" DIA X 10" LONG <br />ANCHOR BOLTS AT 4'-0" O.C. U.O.N. A PLATE WASHER A MINIMUM OF 3" X 3" X 0.229" THICK <br />SHALL BE USED AT EACH BOLT. MIN/MAX END DISTANCE = 1-7/8"; ANCHOR BOLTS SHALL BE <br />EMBEDDED AT LEAST 7" INTO CONCRETE OR MASONRY PER SEC 2308.6 CBC. MIN/MAX END <br />LONGITUDINAL DISTANCE FOR ANCHOR BOLTS 4-3/8" & 12" RESPECTIVELY <br />10. BRIDGING OF JOISTS OR RAFTERS: PROVIDE BRIDGING AT 10'-0" O.C. FOR ROOF RAFTERS <br />AND 8'-0" FOR FLOOR JOISTS. PROVIDE 2 X SOLID BLOCKING AT ALL BEARING LOCATIONS. <br />TABLE 2304.10.2 FASTENING SCHEDULE <br />DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER SPACING AND LOCATION <br />Roof <br />4-8d box (2-1/2 x 0.113″); or <br />3-8d common (2-1/2"× 0.131″); or <br />3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; or <br />3-3″14 gage staples, 7 <br />16"crown <br />Each end, toenail <br />2-8d common (2-1/2" × 0.131″) <br />2-3″ × 0.131″ nails <br />2-3″ 14 gage staples <br />Each end, toenail <br />2-16 d common (3-1/2"× 0.162″) <br />3-3″ × 0.131″ nails <br />3-3″ 14 gage staples <br />End nail <br />Flat blocking to truss and web filler <br />16d common (3-1/2"× 0.162″) @ 6″ o.c. <br />3″ × 0.131″ nails @ 6″ o.c. <br />3″ × 14 gage staples @ 6″ o.c <br />Face nail <br />2.Ceiling joists to top plate <br />4-8d box (2-1/2" x 0.113″); or <br />3-8d common (2-1/2" × 0.131″); or <br />3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, <br />Each joist, toenail <br />3-16d common (3-1/2"× 0.162″); or <br />4-10d box (3″ × 0.128″); or <br />4-3″ × 0.131″ nails; or <br />4-3″ 14 gage staples, <br />Face nail <br />Per Table 2308.7.3.1 Face nail <br />5.Collar tie to rafter <br />3-10d common (3″ × 0.148″); or <br />4-10d box (3″ × 0.128″); or <br />4-3″ × 0.131″ nails; or <br />4-3″ 14 gage staples, <br />Face nail <br />6.Rafter or roof truss to top plate (See Section <br />2308.7.5, Table 2308.7.5) <br />3-10 common (3″ × 0.148″); or <br />3-16d box (3-1/2" × 0.135″); or <br />4-10d box (3″ × 0.128″); or <br />4-3″ × 0.131 nails; or <br />4-3″ 14 gage staples, <br />7.Roof rafters to ridge valley or hip rafters; or roof <br />rafter to 2-inch ridge beam <br />2-16d common (3-1/2" × 0.162″); or <br />3-16d box (3-1/2" × 0.135″); or <br />3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, <br />End nail <br />3-10d common (3-1/2" × 0.148″); or <br />4-16d box (3-1/2" × 0.135″); or <br />4-10d box (3″ × 0.128″); or <br />4-3″ × 0.131″ nails; or <br />4-3″ 14 gage staples, <br />Toenail <br />Wall <br />8.Stud to stud (not at braced wall panels) <br />16d common (3-1/2"× 0.162″);24″ o.c. face nail <br />10d box (3″ × 0.128″); or <br />3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, <br />16″ o.c. face nail <br />Wall <br />16″ o.c. face nail <br />16d box (3-1/2" × 0.135″); or <br />3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, <br />12″ o.c. face nail <br />10.Built-up header (2″ to 2″ header) <br />16d common (3-1/2" × 0.162″)16″ o.c. each edge, face nail <br />16d box (3-1/2" × 0.135″)12″ o.c. each edge, face nail <br />11.Continuous header to stud <br />4-8d common (2-1/2"× 0.131″); or <br />4-10d box (3″ × 0.128″); or <br />5-8d box (2-1/2" x 0.113″) <br />Toenail <br />12.Top plate to top plate <br />16d common (3-1/2" × 0.162″)16″ o.c. face nail <br />10d box (3″ × 0.128″); or <br />3″ × 0.131″ nails; or <br />3″ 14 gage staples, <br />12″ o.c. face nail <br />13.Top plate to top plate, at end joints <br />8-16d common (3-1/2"× 0.162″); or <br />12-16d box (3-1/2" x 0.135″); or <br />12-10d box (3″ × 0.128″); or <br />12-3″ × 0.131″ nails; or <br />12-3″ 14 gage staples, <br />16d common (3-1/2" × 0.162″)16″ o.c. face nail <br />16d box (3-1/2" × 0.135″); or <br />3″ × 0.131″ nails; or <br />3″ 14 gage staples, <br />12″ o.c. face nail <br />2-16d common (3-1/2" × 0.162″); or <br />3-16d box (3-1/2"× 0.135″); or <br />4-3″ × 0.131″ nails; or <br />4-3″ 14 gage staples, <br />16″ o.c. face nail <br />16.Stud to top or bottom plate <br />3-16d box (3-1/2" x 0.135″); or <br />4-8d common (2-1/2" × 0.131″); or <br />4-10d box (3″ × 0.128″); or <br />4-3″ × 0.131″ nails; or <br />4-8d box (2-1/2" x 0.113″); or <br />4-3″ 14 gage staples, <br />Toenail <br />2-16d common (3-1/2" × 0.162″); or <br />3-16d box (3-1/2" x 0.135″); or <br />3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, <br />End nail <br />17.Top plates, laps at corners and intersections <br />2-16d common (3-1/2" × 0.162″); or <br />3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, <br />Face nail <br />18.1″ brace to each stud and plate <br />3-8d box (2-1/2" x 0.113″); or <br />2-8d common (2-1/2" × 0.131″); or <br />2-10d box (3″ × 0.128″); or <br />2-3″ × 0.131″ nails; or <br />2-3″ 14 gage staples, <br />Face nail <br />19.1″ × 6″ sheathing to each bearing <br />3-8d box (2-1/2" x 0.113″); or <br />2-8d common (2-1/2" × 0.131″); or <br />2-10d box (3″ × 0.128″); or <br />2-1-3/4" 16 gage staples, 1″ crown <br />Face nail <br />Wall <br />20.1″ × 8″ and wider sheathing to each bearing <br />3-8d common (2-1/2"× 0.131″); or <br />3-8d box (2-1/2" x 0.113″); or <br />3-10d box (3″ × 0.128″); or <br />3-1-3/4" 16 gage staples, 1″ crown <br />Wider than 1″ × 8″Face nail <br />3-8d common (2-1/2" x 0.131″); or <br />4-8d box (2-1/2"× 0.113″); or <br />3-10d box (3″ × 0.128″); or <br />4-1-3/4"16 gage staples, 1″ crown <br />Floor <br />21.Joist to sill, top plate, or girder <br />4-8d box (2-1/2"× 0.113″); or <br />3-8d common (2-1/2" × 0.131″); or floor <br />3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, <br />Toenail <br />22.Rim joist, band joist, or blocking to top plate, sill <br />or other framing below <br />8d box (2-1/2" × 0.113″) 4" o.c., toenail <br />8d common (2-1/2"× 0.131″); or <br />10d box (3″ × 0.128″); or <br />3″ × 0.131″ nails; or <br />3″ 14 gage staples, <br />6″ o.c., toenail <br />23.1″ × 6″ subfloor or less to each joist <br />3-8d box (2-1/2" × 0.113″); or <br />2-8d common (2-1/2" × 0.131″); or <br />3-10d box (3″ × 0.128″); or <br />2-1-3/4" 16 gage staples, 1″ crown <br />Face nail <br />24.2 subfloor to joist or girder 3-16d box (3-1/2" × 0.135″); or <br />2-16d common (3-1/2"× 0.162″)Blind and face nail <br />25.2″ planks (plank & beam – floor & roof)3-16d box (3-1/2" × 0.135″); or <br />2-16d common (3-1/2" × 0.162″)Each bearing, face nail <br />26.Built-up girders and beams, 2″ lumber layers <br />20d common (4″ × 0.192″)32″ o.c., face nail at top and bottom <br />staggered on opposite sides <br />10d box (3″ × 0.128″); or <br />3″ × 0.131″ nails; or <br />3″ 14 gage staples, <br />Wood structural panels (WSP), subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to framing <br />Edges <br />(inches) <br />Intermediate <br />supports (inches) <br />30. 3/8″ –1/2″ <br />6d common or deformed (2″ × 0.113″); or <br />2-3/8"× 0.113″ nail (subfloor and wall)6 12 <br />8d common or deformed (2-1/2"× 0.131″× <br />0.281″ head) (roof) or <br />RSRS-01 (2-3/8" × 0.113″) nail (roof)d <br />6e 6e <br />13/ 4″16 gage staple, crown (subfloor and <br />wall)4 8 <br />23/ 8″× 0.113″× 0.266″ head nail (roof)3f 3f <br />13/ 4″16 gage staple, crown (roof) 3f 3f <br />31. 19/32″ –3/4″ <br />8d common (2-1/2" × 0.131″); or <br />deformed (2″ × 0.113″) (subfloor and wall)6 12 <br />8d common or deformed (2-1/2"× 0.131″ × <br />0.281″ head) (roof) or <br />RSRS-01 (2-3/8" × 0.113″) nail (roof)d <br />6e 6e <br />2-3/8" × 0.113″× 0.266″ head nail; or <br />2″ 16 gage staple,4 8 <br />32. 7/8″ – 11/4″ <br />10d common (3″ × 0.148″); or <br />deformed (2-1/2"× 0.131″ × 0.281" head)6 12 <br />Other exterior wall sheathing <br />33. 1/2″ fiberboard sheathingb <br />1-1/2" × 0.120″, galvanized roofing nail <br />(7/16″ head diameter); or <br />1-1/4"16 gage staple with or 1″ crown <br />3 6 <br />34. 25/32″ fiberboard sheathingb <br />1-3/4" × 0.120″ galvanized roofing nail <br />(7/16″ diameter head); or <br />1-1/2"16 gage staple with or 1″ crown <br />3 6 <br />Wood structural panels, combination subfloor underlayment to framing <br />35. 3/4″ and less <br />8d common (2-1/2" × 0.131″); or <br />deformed (2″ × 0.113″); or <br />deformed (2" × 0.120") <br />6 12 <br />36. 7/8″ – 1″ <br />8d common (2-1/2"× 0.131″); or <br />deformed (2-1/2"× 0.131″); or <br />deformed (2-1/2" × 0.120″) <br />6 12 <br />37.11/ 8″– 11/4″ <br />10d common (3″ × 0.148″); or <br />deformed (2-1/2"× 0.131″); or <br />deformed (2-1/2" × 0.120") <br />6 12 <br />Panel siding to framing <br />38. 1/2″ or less <br />6d corrosion-resistant siding <br />(1-7/8"× 0.106″); or <br />6d corrosion-resistant casing (2″ × 0.099″) <br />6 12 <br />39. 5/8″ <br />8d corrosion-resistant siding <br />(2-3/8" × 0.128″); or <br />8d corrosion-resistant casing <br />(2-1/2" × 0.113″) <br />6 12 <br />DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER SPACING AND LOCATION <br />Wood structural panels (WSP), subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to framing <br />Edges <br />(inches) <br />Intermediate <br />supports (inches) <br />Interior paneling <br />40.1/4″ <br />4d casing (1-1/2"× 0.080″); or <br />4d finish (1-1/2"× 0.072″)6 12 <br />41.3/8″ <br />6d casing (2″ × 0.099″); or <br />6d finish (2″ × 0.092″) <br />(Panel supports at 24 inches) <br />6 12 <br />For SI:1 inch = 25.4 mm. a.Nails spaced at 6 inches at intermediate supports where spans are 48 inches or more. For nailing of wood <br />structural panel and particleboard diaphragms and shear walls, refer to Section 2305. Nails for wall sheathing are permitted to be <br />common, box or casing. <br />b.Spacing shall be 6 inches on center on the edges and 12 inches on center at intermediate supports for nonstructural applications. <br />Panel supports at 16 inches (20 inches if strength axis in the long direction of the panel, unless otherwise marked). <br />c.Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule and the ceiling joist is fastened to the top <br />plate in accordance with this schedule, the number of toenails in the rafter shall be permitted to be reduced by one nail. <br />d.RSRS-01 is a Roof Sheathing Ring Shank nail meeting the specifications in ASTM F1667. <br />e.Tabulated fastener requirements apply where the ultimate design wind speed is less than 140 mph. For wood structural panel roof <br />sheathing attached to gable-end roof framing and to intermediate supports within 48 inches of roof edges and ridges, nails shall be <br />spaced at 4 inches on center where the ultimate design wind speed is greater than 130 mph in Exposure B or greater than 110 mph in <br />Exposure C. Spacing exceeding 6 inches on center at intermediate supports shall be permitted where the fastening is designed per the <br />AWC NDS. <br />f.Fastening is only permitted where the ultimate design wind speed is less than or equal to 110 mph. <br />g.Nails and staples are carbon steel meeting the specifications of ASTM F1667. Connections using nails and staples of other materials, <br />such as stainless steel, shall be designed by acceptable engineering practice or approved under Section 104.11. <br />Each side of end joint, face nail <br />(mini-mum 24" lap splice length <br />each side of end joint) <br />14.Bottom plate to joist, rim joist, band joist or <br />block-ing (not at braced wall panels) <br />15.Bottom plate to joist, rim joist, band <br />joist or block-ing at braced wall panels <br />9.Stud to stud and abutting studs at <br />intersecting wall corners (at braced wall <br />panels) <br />3.Ceiling joist not attached to parallel rafter, <br />laps over partitions (no thrust) (see Section <br />2308.7.3.1, Table 2308.7.3.1) <br />4.Ceiling joist attached to parallel rafter (heel <br />joint) (see Section 2308.7.3.1, Table 2308.7.3.1) <br />Blocking between rafters or truss not at <br />the wall top plate, to rafter or truss <br />1.Blocking between ceiling joists, rafters <br />or trusses to top plate or other framing <br />below <br />2 toenails on one side and 1 <br />toenail on opposite side of <br />rafter or trussc <br />16d common (3-1/2"× 0.162″) <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16" <br />7 <br />16" <br />7 <br />16"crown <br />7 <br />16" <br />7 <br />16 " <br />And: <br />2-20d common (4″ × 0.192″); or <br />3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, <br />Ends and at each splice, face nail <br />27.Ledger strip supporting joists or rafters <br />3-16d common (3-1/2" × 0.162″); or <br />4-16d box (3-1/2" × 0.135″); or <br />4-10d box (3″ × 0.128″); or <br />4-3″ × 0.131″ nails; or <br />4-3″ 14 gage staples, <br />Each joist or rafter, face nail <br />28.Joist to band joist or rim joist <br />3-16d common (3-1/12" × 0.162″); or <br />4-10d box (3″ × 0.128″); or <br />4-3″ × 0.131″ nails; or <br />4-3″ 14 gage staples, <br />End nail <br />29.Bridging or blocking to joist, rafter or truss <br />2-8d common (2-1/2" × 0.131″); or <br />2-10d box (3″ × 0.128″); or <br />2-3″ × 0.131″ nails; or <br />2-3″ 14 gage staples, <br />Each end, toenail <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />7 <br />16"crown <br />24″ o.c. face nail at top and <br />bottom staggered on opposite <br />sides <br />GENERAL NOTES <br />ANY UNAUTHORIZED REUSE OF THESE PLANS OTHER <br />THAN THE PROJECT AND LOCATION SHOWN IS <br />PROHIBITED. <br />ALL IDEAS, DESIGNS AND PLANS REPRESENTED BY <br />THE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF <br />BCI ENGINEERING AND SHALL NOT BE REPRODUCED <br />IN WHOLE OR IN PART WITHOUT THE EXPRESS PRIOR <br />WRITTEN PERMISSION OF SAID ENGINEER. <br />15375 BARRANCA PKWY. SUITE B-205 <br />IRVINE, CA 92618 <br />(714) 267-6561 <br />ben.ionescu@bciengineeringcompany.com <br />SCALE <br />AS NOTED <br />SHEET <br />No. REVISION/ ISSUE DATE <br />FIRE RESTORATION PROJECT <br />PROJECT NAME AND ADDRESS: <br />JOHN SOTO <br />5510 ROOSEVELT AVE <br />SANTA ANA, CA 92703 <br />PROJECT <br />SOTO <br />DATE <br />JULY, 2024 <br />PROPERTY LINE <br />FIRE DAMAGED AREA <br />EXISTING ELECTRICAL MAIN <br />PANEL (200 AMP) <br />NEW AC <br />CONDENSER <br />BLDG# 101120875 <br />APPROVALS <br />BLDG - CSG Consultant <br />PLNG - FArias <br />5510 W Roosevelt <br />Ave12/10/2024