STEEL WELDING <br />1. WELDING PROCEDURES, ELECTRODES AND WELDER QUALIFICATIONS SHALL CONFORM TO THE “CODE FOR WELDING IN <br />BUILDING CONSTRUCTION,” AMERICAN WELDING SOCIETY (AWS), D1.1 AND THE AISC "SPECIFICATION FOR THE DESIGN, <br />FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS” <br />2. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AWS STANDARD QUALIFICATION TESTS, AND SHALL BE CERTIFIED <br />FOR THE WORK THEY ARE PERFORMING IN ACCORDANCE WITH THE AUTHORITY HAVING JURISDICTION. <br />3. PROJECT WELDING SHALL BE PERFORMED ONLY IN ACCORDANCE WITH WELDING PROCEDURE SPECIFICATIONS (WPS) <br />SUBMITTED BY THE CONTRACTOR AND REVIEWED BY THE SEOR AND PROJECT WELDING INSPECTOR. THE WPS SHALL BE <br />IN ACCORDANCE WITH AWS D1.1-D1.4 CURRENT EDITION. <br />4. WELDING OF STRUCTURAL STEEL SHALL BE PERFORMED PER AWS D1.1 USING E70XX ELECTRODES UNLESS OTHERWISE <br />NOTED. <br />5. WELDING OF REINFORCING BARS SHALL BE PERFORMED PER AWS D1.4 USING E90XX ELECTRODES. <br />6. WELDING OF METAL DECK AND LIGHT GAGE STEEL SHALL BE IN ACCORDANCE WITH AWS D1.3. <br />7. WHERE WELDED METAL DECK ATTACHMENTS ARE SPECIFIED TO STEEL SUPPORTS USE PUDDLE WELDS OR WELDED <br />STUDS SPACED AS NOTED. EFFECTIVE AREA OF PUDDLE WELDS SHALL BE NOT LESS THAN 1/2” EFFECTIVE DIAMETER AND <br />FOR SEAM WELDS NOT LESS THAN 3/8” WIDE BY 1” LONG. <br />8. WELDS SHALL BE TESTED PER AWS D1.1 WITH MAGNETIC PARTICLE TESTING AT A RATE OF 10% UNLESS NOTED <br />OTHERWISE. <br />9. ALL FULL PENETRATION WELDS SHALL BE TESTED PER AWS D1.1 WITH ULTRASONIC TESTING. ALL CJP GROOVE WELDS <br />SHALL BE ULTRASONICALLY TESTED IN MATERIAL 5/16" THICK OR GREATER. FILLET WELDS AND PARTIAL PENETRATION <br />SHALL BE TESTED BY MAGNETIC PARTICLE (MT) AT A RATE OF 40%. <br />10. ALL GROOVE OR BUTT WELDS SHALL BE COMPLETE PENETRATION WELDS, UNO. EXPOSED BUTT WELDS SHALL BE <br />GROUND SMOOTH. <br />11. ALL EXPOSED WELDS ON ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL COMPLY WITH AISC CODE OF <br />STANDARD PRACTICE, SECTION 10. <br />12. FIELD WELDS HAVE BEEN INDICATED WHERE THEY ARE EXPECTED TO OCCUR. THE CONTRACTOR SHALL DETERMINE THE <br />ACTUAL FIELD WELDING NECESSARY TO COMPLETE THE PROJECT AND INCLUDE ALL ASSOCIATED COSTS WITHIN THE <br />BASE PRICE. <br />13. REMOVE ALL WELD TABS AND WELD BACKING BARS UNLESS NOTED OTHERWISE. WHERE BACKING IS REMOVED THE <br />WELD ROOT SHALL BE BACKGOUGED TO SOUND METAL AND FILLED WITH WELD METAL. <br />HIGH STRENGTH BOLTS <br />1. UNLESS NOTED OTHERWISE WHEN BOLTING STEEL COMPONENTS, BOLTS 3/4” DIAMETER AND LARGER SHALL BE ASTM <br />A325 / F1852 HIGH STRENGTH, BOLTS 5/8" DIAMETER AND SMALLER SHALL BE A307. <br />2. JOINT ASSEMBLIES USING HIGH-STRENGTH BOLTS SHALL BE IN ACCORDANCE WITH THE CURRENT EDITION OF THE "AISC <br />(RCSC) SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS". <br />3. HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM A325 / F1852 OR ASTM A490 / F2280 AS INDICATED, TYPE 1 OR 3, NUTS <br />SHALL CONFORM TO ASTM A563 GRADE DH OR A194 GR 2H, AND WASHERS SHALL CONFORM TO ASTM F436 WITH GRADE, <br />TYPE AND FINISH TO MATCH THE SPECIFIED BOLT. <br />4. PAINT SHALL NOT BE PERMITTED ON CONTACT SURFACES UNLESS NOTED OTHERWISE. CONTACT SURFACES OF BOLTED <br />PARTS SHALL BE DESCALED AND FREE OF DIRT, OIL, BURRS, PITS, AND OTHER DEFECTS WHICH PREVENT SOLID SEATING <br />OF PARTS. <br />5. ALL HIGH STRENGTH BOLTS SHALL BE TIGHTENED TO THE AISC SNUG TIGHT CONDITION UNLESS SPECIFIED AS SLIP- <br />CRITICAL (SC). <br />6. SLIP-CRITICAL BOLTS SHALL HAVE CLASS "A" FAYING SURFACES. SLIP-CRITICAL JOINT ASSEMBLIES SHALL BE FULLY PRE- <br />TENSIONED BY TURN-OF-NUT TIGHTENING, CALIBRATED WRENCH TIGHTENING, TENSION CONTROL BOLT ASSEMBLIES <br />CONFORMING TO ASTM F1852 / F2280, OR BY DIRECT TENSION INDICATOR WASHERS CONFORMING TO ASTM F959. <br />7. HIGH STRENGTH BOLT ASSEMBLIES PERMANENTLY EXPOSED TO WEATHER OR MOISTURE SPECIFIED AS ASTM A325 / <br />F1852 SHALL BE TYPE 1 GALVANIZED PER ASTM F2329 OR B695, AND ASTM A490 / F2280 SHALL BE TYPE 3 PLAIN WITH <br />GRADE DH3 NUTS. <br />STRUCTURAL STEEL SCHEDULE <br />62 <br />65 <br />58 <br />60 <br />60 <br />58 <br />- <br />35 <br />- <br />36 <br />B7 <br />- <br />58 <br />58 <br />36 OR 55 WELDABLE <br />A <br />36 <br />50 <br />B <br />- <br />A193 <br />A36 <br />F1554 <br />A307 <br />A53 <br />A1085 <br />HIGH STRENGTH ROD <br />THREADED RODS <br />ANCHOR ROD, ANCHOR BOLTS <br />MACHINE BOLTS <br />PIPE <br />WHEN NOTED AS GR 50 <br />50 <br />46 <br />50 <br />65 <br />36 <br />C <br />C <br />65 <br />- <br />- <br />A500 <br />A500 <br />A572 <br />A36 <br />MIN Fu <br />(ksi) <br />MIN Fy <br />(ksi)GRADEASTM <br />ROUND <br />SQUARE OR RECTANGULAR <br />HOLLOW STRUCTURAL SECTION (HSS) <br />WHEN NOTED AS GR 65 <br />58 <br />A992 65 <br />TYPICAL UNO <br />PLATE, ANGLE & CHANNEL (PL, L, C, MC) <br />WIDE FLANGE (W, M, & S) & TEE <br />SHAPE <br />62 <br />1. DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE SPECIFICATIONS AND <br />STANDARDS OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), AS CONTAINED IN THE LATEST EDITION OF <br />"SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AISC 360, AND “CODE OF STANDARD PRACTICE FOR STEEL <br />BUILDINGS AND BRIDGES” AISC 303. <br />2. STEEL TYPE SHALL BE AS SPECIFIED IN THE STRUCTURAL STEEL SCHEDULE UNLESS NOTED OTHERWISE. <br />3. ALL CONNECTIONS NOT SHOWN SHALL CONFORM TO THE "AISC MANUAL OF STEEL CONSTRUCTION" AND SHALL BE <br />SUBMITTED ON SHOP DRAWINGS FOR REVIEW BY SEOR PRIOR TO FABRICATION. <br />4. FABRICATOR SHALL BE LICENSED IN CONFORMANCE WITH THE BUILDING CODE AND IN ACCORDANCE WITH THE <br />AUTHORITY HAVING JURISDICTION. ANY FABRICATOR SUPPLYING MORE THAN 1 TON OF STEEL SHALL BE AISC CERTIFIED. <br />5. ALL STRUCTURAL AND MISCELLANEOUS STEEL PERMANENTLY EXPOSED TO WEATHER OR MOISTURE SHALL BE HOT DIP <br />GALVANIZED PER ASTM A123 AFTER FABRICATION UNLESS A WEATHER PROOF COATING IS SPECIFIED. STEEL IN CONTACT <br />WITH TREATED WOOD SHALL BE GALVANIZED. STAINLESS AND WEATHERING STEELS WHERE SPECIFIED ARE EXEMPT. <br />6. BOLT AND THREADED ROD ASSEMBLIES PERMANENTLY EXPOSED TO WEATHER OR MOISTURE SHALL BE HOT DIP <br />GALVANIZED PER ASTM F2329 UNLESS A FIELD APPLIED WEATHER PROOF COATING IS SPECIFIED. GALVANIZED NUTS ARE <br />TO BE OVERTAPPED WHERE REQUIRED TO AVOID STRIPPING. GALVANIZED BOLT ASSEMBLIES SHALL BE LUBRICATED AND <br />TESTED PRIOR TO SHIPMENT. ALL THREADED COMPONENTS OF FASTENER ASSEMBLY SHALL BE GALVANIZED USING THE <br />SAME PROCESS. <br />7. COATED STEEL SURFACES SHALL BE PROTECTED DURING CONSTRUCTION AND REPAIRED AS REQUIRED. <br />8. USE THE APPROPRIATE NUT AND WASHER TYPE, GRADE AND FINISH FOR THE SPECIFIED BOLT. BOLTS WITH UPSET <br />THREADS ARE NOT ALLOWED UNLESS EXPLICITLY SPECIFIED. PROVIDE ASTM A194 GR 2H NUTS WITH ASTM A193 GR B7 <br />THREADED ROD. <br />9. PLACE NONSHRINK GROUT UNDER ALL BASE PLATES AND ALLOW TO CURE BEFORE APPLYING LOADS. INDICATE GROUT <br />VENT HOLES ON SHOP DRAWINGS WHERE REQUIRED. PRIMED OR PLAIN STEEL TO BE IN DIRECT CONTACT WITH <br />NONSHRINK GROUT SHALL BE CLEANED TO BARE METAL BEFORE GROUTING. <br />10. FOR STEEL EMBEDDED IN CONCRETE OR MASONRY WHICH WILL INTERFERE WITH CONTINUOUS REINFORCING BARS, <br />REQUEST CLARIFICATION FROM THE SEOR WHETHER TO PROVIDE HOLES FOR PASSAGE. DO NOT CUT HOLES IN <br />STRUCTURAL STEEL WITHOUT PRIOR APPROVAL OF SEOR. <br />11. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL STEEL FEATURES SUCH AS TABS, STUDS, WEEP HOLES OR OTHER <br />ITEMS NOT SHOWN. <br />12. ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL COMPLY WITH AISC CODE OF STANDARD PRACTICE, <br />SECTION 10. <br />13. WELDED HEADED STUDS, THREADED STUDS, AND DEFORMED BARS SHALL COMPLY WITH ASTM A108 OR A496 TYPE C BY <br />NELSON, OR <br />EQUIVALENT, AND WELDED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS BY CERTIFIED WELDERS SO AS <br />TO FULLY DEVELOP THE TENSILE CAPACITY OF THE CONNECTOR. <br />14. EMBEDDED ENDS OF ANCHORS IN CONCRETE OR GROUTED CMU SHALL BE HEADED OR HAVE DOUBLE NUTS LOCKED <br />AGAINST EACH OTHER, UNO ON DRAWINGS. <br />MATERIALS AND SYMBOLS <br />LFRS STEEL LATERAL FORCE <br />RESISTING SYSTEM, SEE SHEET <br />S001 AND SPECIFICATIONS <br />SHEET REFERENCE <br />SECTION OR DETAIL <br />FULL HEIGHT SECTION <br />WALL OR FRAME ELEVATION <br />FINISH ELEVATION <br />SHEET REFERENCE <br />NUMBER REFERENCE <br />SHEET REFERENCE <br />NUMBER REFERENCE <br />REFER TO PLANS <br />FOR DATUM <br />NUMBER REFERENCE <br />MATERIALS <br />CONCRETE <br />CONCRETE BLOCK <br />EARTH <br />SYMBOLS <br />STEEL <br />1. DESIGN, FABRICATION AND ERECTION OF COLD-FORMED STEEL FRAMING SHALL CONFORM TO THE CURRENT CBC <br />ADOPTED EDITION OF THE SPECIFICATIONS AND STANDARD OF THE AMERICAN IRON AND STEEL INSTITUTE (AISI), AS <br />CONTAINED IN THE "SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS", INCLUDING <br />ALL APPLICABLE AMENDMENTS. <br />2. ALL COLD-FORMED STEEL FRAMING SHALL BE ERECTED PLUMB AND TRUE TO LINE. TEMPORARY BRACING SHALL BE <br />INSTALLED AND LEFT IN PLACE UNTIL OTHER MEANS IS PROVIDED TO ADEQUATELY BRACE THE STRUCTURE. ALL <br />COLD-FORMED STEEL FRAMING SHALL BE BRACED AS REQUIRED BY SECTION D3 OF THE AISI SPECIFICATION. <br />3. COLD-FORMED STEEL GRADES (ASTM A1003): <br />18 GA (43 MILS) OR THINNER.........................................................................................................................GRADE 33 (Fy = 33 KSI) <br />16 GA (54 MILS) AND THICKER.......................................................................................................................GRADE 50 (Fy = 50 KSI) <br />4. SUBMIT COLD-FORMED STEEL FRAMING SHOP DRAWINGS AND SPECIFICATIONS TO THE SEOR AND AOR FOR <br />REVIEW AND APPROVAL PRIOR TO FABRICATION. <br />5. COLD-FORMED STEEL STUDS AND TRACKS ARE TO BE ATTACHED WITH SHEET METAL SCREWS (SMS) WITH SIZES <br />CALLED OUT ON THE DETAILS. PENETRATION OF SCREWS THROUGH JOINED MATERIAL SHALL NOT BE LESS THAN 3 <br />EXPOSED THREADS. SCREWS ARE TO BE INSTALLED AND TIGHTENED IN ACCORDANCE WITH SCREW <br />MANUFACTURER'S RECOMMENDATIONS. SHEET METAL SCREWS SHALL COMPLY WITH ASTM C1513, SELF-DRILLING <br />AND TAPPING TYPE, WITH PANCAKE FRAMER HEAD TYPE FOR #10 SMS AND HEX WASHER HEAD TYPE FOR #12 AND # <br />14 (1/4"Ø) SMS UNLESS NOTED OTHERWISE. <br />6. COLD-FORMED STUD MEMBERS SHALL BE UNPUNCHED WHERE USED FOR THE FOLLOWING: HEADERS AND SILLS OF <br />OPENINGS WIDER THAN 3'-0", AND BUILT-UP BOX AND BACK-TO-BACK SECTIONS. PUNCH-OUTS SHALL BE LOCATED IN <br />THE CENTER OF THE WEB WITH A MINIMUM SPACING OF 24"OC, HAVE A MAXIMUM WIDTH OF HALF THE MEMBER <br />DEPTH OR 2 1/2", WHICHEVER IS LESS, AND A MAXIMUM LENGTH OF 4 1/2". THE MINIMUM DISTANCE BETWEEN THE <br />END OF THE MEMBER AND THE NEAR EDGE OF THE PUNCH-OUT SHALL BE 12". <br />WELDING OF LIGHT GAGE STEEL SHALL BE IN ACCORDANCE WITH AMERICAN WELDING SOCIETY (AWS) D1.3. <br />COLD-FORMED STEEL FRAMING STRUCTURAL STEEL <br />No. 6250 <br />FFOHSIB <br />RYAN W. <br />REGISTEREDPROFESSIONALENGINEER <br />STRUCTURALSTATEOFCALIFORNIA <br />DATE: <br />FOR BRANDOW & JOHNSTON <br />STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) <br />3300 IRVINE AVE. SUITE 245 <br />NEWPORT BEACH, CALIFORNIA 92660 <br />T:(949)862-8500 WWW.BJSCE.COM <br />JOB#: <br />1 <br />7 <br /> <br />8 <br /> <br />8 <br /> <br />0 <br /> <br /> <br />S <br /> <br />k <br /> <br />y <br /> <br /> <br />P <br /> <br />a <br /> <br />r <br /> <br />k <br /> <br /> <br />C <br /> <br />i <br /> <br />r <br /> <br />c <br /> <br />l <br /> <br />e <br /> <br />, <br /> <br /> <br />S <br /> <br />u <br /> <br />i <br /> <br />t <br /> <br />e <br /> <br />2 <br /> <br />3 <br /> <br />0 <br /> <br /> <br />- <br />I <br />r <br /> <br />v <br /> <br />i <br /> <br />n <br /> <br />e <br /> <br />, <br /> <br /> <br />C <br /> <br />A <br /> <br /> <br />9 <br /> <br />2 <br /> <br />6 <br /> <br />1 <br /> <br />4 <br />t <br /> <br />e <br /> <br /> <br />l <br /> <br /> <br /> <br />9 <br /> <br /> <br />4 <br /> <br /> <br />9 <br /> <br /> <br /> <br />. <br /> <br /> <br /> <br />5 <br /> <br /> <br />5 <br /> <br /> <br />3 <br /> <br /> <br /> <br />. <br /> <br /> <br /> <br />8 <br /> <br /> <br />9 <br /> <br /> <br />0 <br /> <br /> <br />0 <br />a <br />r <br /> <br />c <br /> <br />h <br /> <br />i <br /> <br />t <br /> <br />e <br /> <br />c <br /> <br />t <br /> <br />u <br /> <br />r <br /> <br />e <br /> <br />i <br /> <br />n <br /> <br />t <br /> <br />e <br /> <br />r <br /> <br />i <br /> <br />o <br /> <br />r <br /> <br /> <br />d <br /> <br />e <br /> <br />s <br /> <br />i <br /> <br />g <br /> <br />n <br />p <br />l <br /> <br />a <br /> <br />n <br /> <br />n <br /> <br />i <br /> <br />n <br /> <br />g <br />DA <br />I <br />M <br />L <br />E <br />R <br /> <br />A <br />C <br />P <br />L <br />30 <br />0 <br />9 <br /> <br />D <br />A <br />I <br />M <br />L <br />E <br />R <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br /> <br />9 <br />2 <br />7 <br />9 <br />5 <br />S0.3 <br />GENERAL NOTES <br />07/23/24 <br />ABBREVIATIONS <br />A <br />AB ANCHOR BOLT <br />ADDL ADDITIONAL <br />ADJ ADJACENT <br />AFF ABOVE FINISH FLOOR <br />ALT ALTERNATE <br />ARCH ARCHITECT(URAL) <br />B <br />BLDG BUILDING <br />BLKG BLOCKING <br />BM BEAM <br />BN BOUNDARY NAILING <br />BO BOTTOM OF <br />BOTT, (B) BOTTOM <br />BTWN BETWEEN <br />C <br />C CAMBER <br />CIP CAST IN PLACE <br />CJ CONTROL/CONSTRUCTION JOINT <br />CJP, CP COMPLETE JOINT PENETRATION <br />CL CENTERLINE <br />CLG CEILING <br />CLR CLEAR <br />CMU CONCRETE MASONRY UNIT <br />COL COLUMN <br />CONC CONCRETE <br />CONN CONNECTION <br />CONT CONTINUOUS <br />CTR(D) CENTER(ED) <br />CY CUBIC YARDS <br />D <br />DB BAR DIAMETER <br />DBL DOUBLE <br />DC DEMAND CRITICAL <br />DEMO DEMOLISH, DEMOLITION <br />DIA, DIAM DIAMETER <br />DIAG DIAGONAL <br />DIM DIMENSION <br />DO DITTO <br />DWG DRAWING <br />E <br />EA EACH <br />EF EACH FACE <br />EJ EXPANSION JOINT <br />ELEC ELECTRICAL <br />ELEV ELEVATION, ELEVATOR <br />EMBED EMBEDMENT <br />EN EDGE NAIL <br />EO EDGE OF <br />EQ EQUAL <br />EQUIP EQUIPMENT <br />ES EACH SIDE <br />EW EACH WAY <br />EXIST, (E) EXISTING <br />EXP EXPANSION <br />EXT EXTERIOR <br />F <br />FLR FLOOR <br />FN FIELD NAILING <br />FND FOUNDATION <br />FO FACE OF <br />FS FAR SIDE <br />FT FOOT, FEET <br />FTG FOOTING <br />G <br />GA GAUGE <br />GALV GALVANIZED <br />GC GENERAL CONTRACTOR <br />GLBM, GB GLUED-LAMINATED BEAM <br />GR GRADE <br />GRBM GRADE BEAM <br />H <br />HK HOOK <br />HORIZ HORIZONTAL <br />HS HIGH STRENGTH <br />HSS HOLLOW STRUCTURAL SECTION <br />HT HEIGHT <br />I <br />ID INSIDE DIAMETER <br />IN INCH <br />INT INTERIOR <br />ABBREVIATIONS <br />J <br />JT JOINT <br />K <br />K, KIP(S) KILOPOUND <br />KLF KIPS PER LINEAR FOOT <br />KSF KIPS PER SQUARE FOOT <br />KSI KIPS PER SQUARE INCH <br />L <br />L ANGLE <br />LB, LBS POUND(S) <br />LF LINEAR FEET <br />LFRS LATERAL FORCE RESISTING SYSTEM <br />LLH LONG LEG HORIZONTAL <br />LLV LONG LEG VERTICAL <br />M <br />MAX MAXIMUM <br />MB MACHINE BOLT <br />MECH MECHANICAL <br />MFR MANUFACTURE <br />MIN MINIMUM <br />MW MEDIUM WEIGHT <br />N <br />(N) NEW <br />NDT NON-DESTRUCTIVE TESTING <br />NS NEAR SIDE <br />NTS NOT TO SCALE <br />NW(C) NORMAL WEIGHT (CONCRETE) <br />O <br />OC ON CENTER <br />OD OUTSIDE DIAMETER <br />OH OPPOSITE HAND <br />OPP OPPOSITE <br />P <br />PAF, PDF POWDER DRIVEN/POWER ACTUATED <br />FASTENER <br />PJP, PP PARTIAL JOINT PENETRATION <br />PL PLATE <br />PLF POUND PER LINEAR FOOT <br />PSF POUND PER SQUARE FOOT <br />PSI POUND PER SQUARE INCH <br />PT PRESSURE TREATED WOOD, <br />POST/PRE-TENSIONED <br />R <br />R RADIUS <br />REF REFERENCE <br />REINF REINFORCING <br />REQD REQUIRED <br />S <br />(S)EOR (STRUCTURAL) ENGINEER OF RECORD <br />SC SLIP CRITICAL <br />SCHED SCHEDULE <br />SDS, SMS SELF-DRILLING / SHEET METAL SCREW <br />SFRS SEISMIC FORCE RESISTING SYSTEM <br />SIM SIMILAR <br />SN SILL NAILING <br />SOG SLAB ON GRADE <br />SPECS SPECIFICATIONS <br />SQ SQUARE <br />SS STAINLESS STEEL <br />STD STANDARD <br />STIFF STIFFENER <br />STL STEEL <br />STRUCT STRUCTURAL <br />SYM SYMMETRICAL <br />T <br />T&B TOP & BOTTOM <br />TO TOP OF <br />TYP TYPICAL <br />U <br />UNO UNLESS NOTED OTHERWISE <br />V <br />VERT VERTICAL <br />VIF VERIFY IN FIELD <br />W <br />W/ WITH <br />W/O WITHOUT <br />WF WIDE FLANGE <br />WP WORK POINT <br />WT WEIGHT <br />WWF WELDED WIRE FABRIC <br />NO. REMARKS DATE <br />60% COMPLETE SET 05/28/24 <br />90% COMPLETE SET 07/12/24 <br />ISSUE FOR BID 07/16/24 <br />CITY SUBMITTAL 07/23/24 <br />3009 S Daimler St <br />11/18/2024