PRODUCT SPECIFICATION <br />1. THE STRUCTURAL PRODUCT SCHEDULE INDICATES BASIS-OF-DESIGN MANUFACTURERS AND PRODUCTS FOR USE ON <br />THIS PROJECT. WHERE STRUCTURAL PRODUCTS ARE NOT EXPLICITLY NAMED IN THE CONSTRUCTION DOCUMENTS, <br />PROVIDE A LISTED PRODUCT. <br />2. PRODUCTS SHALL BE INSTALLED PER THE MANUFACTURER’S INSTALLATION INSTRUCTIONS AS AMENDED BY THE <br />REFERENCED PRODUCT ACCEPTANCE REPORTS (ICC, IAPMO, ETC.) FOR THE INTENDED USE. <br />3. AT CONTRACTOR’S OPTION, SUBSTITUTION REQUESTS MAY BE MADE FOR LIKE PRODUCTS WHICH DEMONSTRATE <br />QUALITIES THAT EQUAL OR EXCEED THOSE OF SPECIFIED PRODUCTS. <br />EXISTING CONDITIONS <br />1. SEE ORIGINAL DRAWINGS FOR EXISTING BUILDING INFORMATION NOT SHOWN OR NOTED. <br />2. SEE PROJECT REPORTS AND ARCHITECTURAL DRAWINGS FOR HAZARDOUS MATERIALS (LEAD, ASBESTOS, ETC.) <br />ABATEMENT REQUIREMENTS. <br />3. WHERE EXISTING CONDITIONS VARY SIGNIFICANTLY FROM THOSE SHOWN ON THESE DRAWINGS, THE SEOR SHALL BE <br />NOTIFIED PRIOR TO CONTINUED CONSTRUCTION RELATED TO SUBJECT CONDITIONS. <br />4. EXISTING CONCRETE SURFACES TO BE IN CONTACT WITH NEW CONCRETE SHALL BE ROUGHENED AS FOR TYPICAL <br />CONSTRUCTION JOINTS, AND AN ASTM C1059 COMPLIANT BONDING AGENT SHALL BE APPLIED PRIOR TO PLACING NEW <br />CONCRETE. <br />5. DO NOT CUT OR DAMAGE EXISTING CONCRETE OR MASONRY REINFORCEMENT EXCEPT AS CLEARLY INDICATED. <br />MAINTAIN AT LEAST 2 INCHES CLEAR TO EXISTING REINFORCEMENT, CONDUIT AND OTHER EMBEDDED ITEMS FROM <br />CUTS, CORES, DRILL HOLES, SHOTPINS, ETC. IN AREAS OF WORK, MARK LOCATIONS OF SUCH ITEMS USING <br />NONDESTRUCTIVE METHODS SUCH AS GROUND PENETRATING RADAR OR X-RAY. <br />6. THE GENERAL CONTRACTOR SHALL COORDINATE THE SPECIFIC LOCATION OF REPLACEMENT MECHANICAL EQUIPMENT <br />WITH THE STRUCTURAL FRAMING. IF NEW EQUIPMENT DEVIATES IN WEIGHT, SIZE OR LOCATION FROM EXISTING <br />EQUIPMENT BEING REPLACED, SEOR APPROVAL MUST BE OBTAINED PRIOR TO INSTALLATION OF THE UNITS. <br />7. EXISTING STRUCTURAL MEMBERS SUPPORTING NEW EQUIPMENT SHALL BE INSPECTED FOR DAMAGE AND <br />DETERIORATION PRIOR TO INSTALLATION OF THE UNITS. NOTIFY THE SEOR OF SUCH CONDITIONS AND DO NOT INSTALL <br />UNITS UNTIL THE CONDITIONS ARE ADDRESSED. <br />8. DURING THE COURSE OF WORK, NOTIFY THE SEOR OF EXISTING STRUCTURAL DETERIORATION, APPARENT DISTRESS, <br />WATER INTRUSION, OR COMPROMISED MEMBERS THAT ARE DISCOVERED. <br />9. REPAIR FIREPROOFING, WATERPROOFING AND FINISHES AS REQUIRED WHERE DISTURBED BY STRUCTURAL WORK. <br />SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. <br />10. EXISTING WOOD MEMBER SIZES MAY BE FULL-SIZE OR NONSTANDARD RELATIVE TO CURRENT PRACTICE. PROVIDE <br />FULL-SIZE CURED, OR CUT NEW STRUCTURAL WOOD TO MATCH WHERE INDICATED. DO NOT FUR OUT TO MAKE UP <br />GAPS BETWEEN NEW STRUCTURAL MEMBERS OR SHEATHING UNLESS SPECIFICALLY DETAILED OR NOTED. <br />2” <br />1 1/2" <br />3" <br />2” <br />1 1/2" <br />MINIMUM CONCRETE COVER OF REINFORCEMENT SCHEDULE <br />CONDITION <br />INTERIOR RAISED SLABS AND INTERIOR WALL FACES <br />INTERIOR COLUMNS AND BEAMS <br />OTHER INTERIOR CONCRETE, #11 BARS AND SMALLER <br />FORMED AND EXPOSED TO SOIL OR WEATHER, <br />#6 BARS AND LARGER: <br /> #5 BARS AND SMALLER: <br />CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL <br />STRUCTURAL SLAB-ON-GRADE, <br />FROM BOTTOM OF SLAB: <br /> FROM TOP OF SLAB: <br />SEE ESR <br />26049 <br />25966 <br />ADHEVISE <br />ANCHOR TO <br />GROUTED CMU <br />25620 <br />26050 <br />FIBER-REINFORCED <br />POLYMER (FRP) <br />SYSTEMS <br />REINFORCEMENT <br />BAR TERMINATOR <br />25342 <br />25347 <br />24507 <br />REINFORCEMENT <br />BAR COUPLER <br />02725 <br />25860 <br />WELDED STUD <br />25979 <br />25560 <br />SCREW ANCHOR TO <br />GROUTED CMU <br />(≥ 1/4” DIAM) <br />25577M <br />25864 <br />25831 <br />25936 <br />EXPANSION <br />ANCHOR TO <br />GROUTED CMU <br />25675 <br />22668 <br />25469 <br />SHOTPIN <br />25975 <br />SCREW ANCHOR <br />TO CONCRETE <br />(≤ 3/16” DIAM) <br />25897 <br />25741 <br />25808 <br />SCREW ANCHOR <br />TO CONCRETE <br />(≥ 1/4” DIAM) <br />25964 <br />26028 <br />- <br />26035 <br />25960 <br />NA <br />ADHESIVE <br />ANCHOR TO <br />CONCRETE <br />NA <br />25831 <br />25891 <br />STRUCTURAL PRODUCT SCHEDULE <br />LARR <br />EXPANSION <br />ANCHOR TO <br />CONCRETE <br />25815 <br />25893 <br />REINFORCING STEEL <br />1. PLACING TOLERANCES AND BAR SUPPORTS SHALL CONFORM TO THE “MANUAL OF STANDARD PRACTICE” FOR <br />REINFORCED CONCRETE CONSTRUCTION, BY CONCRETE REINFORCING STEEL INSTITUTE (CRSI). <br />2. ALL REINFORCING BAR (REBAR) STEEL SHALL BE DEFORMED ROUND BARS CONFORMING TO ASTM A615 OR ASTM A706, <br />GRADE 60. <br />3. WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A1064. ADJACENT WWF SHEETS SHALL BE LAPPED 12 INCHES <br />MINIMUM. <br />4. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCING IN POSITIONS INDICATED. CHAIRS OR BOLSTERS <br />WHICH BEAR AGAINST FORMS FOR EXPOSED SURFACES SHALL BE GREY COLORED PLASTIC COATED STEEL OR <br />STAINLESS STEEL. <br />5. REINFORCING BARS SHALL BE KEPT CLEAN AND FREE OF OIL, GREASE AND LOOSE RUST OR MILL SCALE. <br />6. BEND REINFORCING BARS COLD. BARS PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT. <br />7. ALL REINFORCING SHALL BE CONTINUOUS UNLESS NOTED OTHERWISE, WITH CONTACT LAP SPLICES PER THE TYPICAL <br />DETAILS OR AS SHOWN. <br />8. PROVISION FOR LAP SPLICES OR DOWELS SHALL BE PROVIDED ACROSS ALL CONSTRUCTION JOINTS AND SHALL BE THE <br />SAME GRADE, SIZE AND SPACING AS REINFORCING CONTINUING BEYOND UNLESS NOTED OTHERWISE. IN LIEU OF <br />SPLICES OR DOWELS, THE CONTRACTOR MAY SUBMIT FOR SEOR APPROVAL THE LOCATION AND MANUFACTURER DATA <br />OF FORMSAVERS OR COUPLERS PRIOR TO THEIR USE. <br />9. ALL BENDS WITHIN HOOKS, STIRRUPS, HOOPS AND CROSS-TIES SHALL ENGAGE A LONGITUDINAL BAR, PROVIDE A #5 <br />CONTINUOUS BAR WHERE ONE IS NOT SPECIFICALLY DETAILED. <br />10. CLEARANCE BETWEEN PARALLEL BARS, OR BARS AND CONSTRUCTION JOINTS SHALL BE NOT LESS THAN THE SMALLER <br />OF 1 INCH, 1 BAR DIAMETER, OR THE MAXIMUM AGGREGATE SIZE. UNLESS NOTED OTHERWISE, BARS IN PARALLEL <br />LAYERS SHALL BE PLACED IN ALIGNMENT WITH ONE ANOTHER. <br />11. MAINTAIN A MINIMUM COVER FROM FACE OF CONCRETE TO EDGE OF REINFORCEMENT PER THE MINIMUM CONCRETE <br />COVER OF REINFORCEMENT SCHEDULE OR AS DETAILED. PROVIDE THE LARGEST COVER REQUIRED FOR ALL <br />APPLICABLE CONDITIONS AND BAR SIZES. WHERE #3 STIRRUPS OR TIES ARE USED, ENSURE THAT THE COVER FOR <br />LONGITUDINAL BARS IS ADEQUATE. <br />12. THE FOLLOWING REINFORCEMENT SHALL CONFORM TO ASTM A706: <br />a. REINFORCEMENT TO BE WELDED. <br />b. LONGITUDINAL COLUMN AND BEAM REINFORCEMENT IN DESIGNATED MOMENT FRAMES. <br />c. VERTICAL REINFORCEMENT AT INTERSECTIONS AND ENDS OF DESIGNATED <br />CONCRETE SHEAR WALLS ENCLOSED IN TIES. <br />3/4" CLRCLEARANCE FROM METAL DECK <br />ESR-4143 <br />ESR-3200 <br />ER-0281 <br />ESR-2103 <br />ESR-2606 <br />ESR-2495 <br />ESR-2746 <br />ER-0129 <br />ESR-2856 <br />ESR-2907 <br />ESR-3056 <br />ESR-1056 <br />ESR-0677 <br />ESR-2818 <br />ESR-2502 <br />ER-0240 <br />ESR-2269 <br />ESR-1799 <br />ESR-2138 <br />ESR-2202 <br />ESR-3027 <br />ESR-2713 <br />ESR-2526 <br />ESR-3187 <br />ESR-3814 <br />ESR-4027 <br />ESR-3298 <br />ER-0263 <br />ESR-4057 <br />ESR-4266 <br />ESR-2502 <br />ESR-3037 <br />ESR-2746 <br />ER-0188 <br />HILTI HIT-HY 270 <br />DEWALT/POWERS AC100+ GOLD <br />SIMPSON AT-XP <br />FYFE TYFO FIBRWRAP <br />STRUCTURAL TECH V-WRAP <br />DAYTON BAR LOCK L-SERIES <br />HRC 500/510 XTENDER <br />LENTON <br />NELSON SHEAR CONNECTOR STUDS <br />NELSON D2L DEFORMED BAR ANCHOR <br />HILTI KWIK HUS-EZ <br />SIMPSON TITEN HD <br />HILTI KWIK BOLT 1 <br />DEWALT/POWERS STUD+ SD1 <br />DEWALT/POWERS STUD+ SD4, SD6 <br />SIMPSON STRONG-BOLT 2 <br />HILTI LOW-VELOCITY X-U <br />ITW RAMSET POWER-DRIVEN <br />SIMPSON POWDER-ACTUATED <br />ITW RED HEAD TAPCON <br />HILTI KWIK HUS-EZ, -EZ 1 <br />SIMPSON TITEN HD <br />DEWALT/POWERS WEDGE-BOLT+ <br />HILTI HIT-HY 200 <br />HILTI HIT-RE 500-V3 <br />DEWALT/POWERS AC200+ <br />DEWALT/POWERS PURE110+ <br />SIMPSON AT-XP <br />SIMPSON SET-3G <br />HILTI KWIK BOLT TZ2 <br />DEWALT/POWERS-STUD+ SD2 <br />SIMPSON STRONG-BOLT 2 <br />HRC 555/670 HEADED REINF. BARS <br />LENTON TERMINATOR <br />ICC / IAPMOPRODUCTTYPE <br />MIN.COVER <br />1” <br />1 1/2" <br />3/4" <br />STRUCTURAL CONCRETE <br />1. CONCRETE SHALL BE MIXED, PLACED AND CURED IN ACCORDANCE WITH ACI 318 AND ACI 301 LATEST EDITION AND THE <br />CONSTRUCTION DOCUMENTS. <br /> <br />2. CONCRETE MIXING OPERATIONS SHALL CONFORM TO ASTM C94. QUANTITIES OF MATERIALS SHALL BE CERTIFIED BY A <br />LICENSED WEIGHT-MASTER. <br />3. RETAIN AN APPROVED TESTING LABORATORY, ACCEPTABLE TO THE OWNER, TO PREPARE CONCRETE MIX DESIGNS <br />ACCORDING TO GOVERNING CODE AND THE CONSTRUCTION DOCUMENTS. ALL CONCRETE MIXES SHALL BE STAMPED <br />AND SEALED BY A LICENSED CALIFORNIA CIVIL ENGINEER AND SUBMITTED TO THE SEOR FOR REVIEW PRIOR TO <br />CONCRETE PLACEMENT. NEW MIX DESIGNS ARE REQUIRED WHEN THERE IS A CHANGE IN MATERIALS BEING USED. MIX <br />DESIGNS SHALL CLEARLY STATE THE INTENDED LOCATION FOR USE. <br />4. CONCRETE SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS AS INDICATED ON THE CONCRETE <br />SCHEDULE. ALL CONCRETE TEST REPORTS SHALL BE SUBMITTED TO THE SEOR WITHIN 7 DAYS AFTER TESTING. <br />5. AGGREGATE SHALL BE HARDROCK FOR NORMAL WEIGHT CONCRETE (NWC) CONFORMING TO ASTM C33. THE UNIT <br />WEIGHT OF NWC SHALL HAVE AN AIR-DRY EQUILIBRIUM DENSITY OF 145 ± 5 PCF. THE UNIT WEIGHT OF NWC SHALL BE <br />CONFIRMED BY THE MIX DESIGN AND DOES NOT REQUIRE TESTING UNO. <br />6. AGGREGATE FOR SAND LIGHT WEIGHT CONCRETE (LWC) SHALL CONFORM TO ASTM C330. UNIT WEIGHT OF LWC SHALL <br />NOT EXCEED 115 PCF MEASURED AIR-DRY EQUILIBRIUM DENSITY PER ASTM C567, OR 110 PCF MEASURED OVEN-DRY. <br />THE UNIT WEIGHT OF LWC SHALL BE LAB TESTED FOR EACH MIX DESIGN AND AGGREGATE SOURCE. <br />7. COARSE AGGREGATE WITH A MAXIMUM SIZE OF 1/2 INCH OR LESS SHALL BE CRUSHED STONE. <br />8. PORTLAND CEMENT TYPE SHALL BE AS SPECIFIED IN THE CONCRETE SCHEDULE AND CONFORM TO ASTM C150, LOW <br />ALKALI. <br />9. FLY ASH OR OTHER POZZOLANS CONFORMING TO ASTM C618 CLASS F MAY BE USED AS A PARTIAL SUBSTITUTION FOR <br />PORTLAND CEMENT UP TO A MAXIMUM OF 25% TOTAL CEMENTITIOUS MATERIAL BY WEIGHT WHEN THE MIX DESIGN IS <br />PROPORTIONED BY FIELD EXPERIENCE OR TRIAL MIXTURES. <br />10. WATER USED IN MIX SHALL BE POTABLE OR NONPOTABLE RECLAIMED/RECYCLED, CONFORMING TO ASTM C1602. PRIOR <br />TO MIXING, FREE MOISTURE CONTENT OF AGGREGATES SHALL BE MEASURED, RECORDED, AND MIX WATER QUANTITY <br />ADJUSTED ACCORDINGLY. MIX WATER AND FREE MOISTURE ON AGGREGATES SHALL NOT CONTAIN CHLORIDES OR ANY <br />OTHER DELETERIOUS OR ODOROUS COMPOUNDS. <br />11. ADMIXTURES, WHERE USED FOR WATER REDUCTION AND SETTING TIME MODIFICATION SHALL CONFORM TO ASTM C494, <br />SUPERPLASTICIZER SHALL CONFORM TO ASTM C1017. <br />12. SHRINKAGE REDUCING ADMIXTURES SHALL CONFORM TO ASTM C494, AND WHERE USED SHALL BE GRACO ECLIPSE, <br />EUCLID EUCON SRA, SIKA CONTROL, OR APPROVED EQUAL. SPECIFIED MAXIMUM SHRINKAGE RATES SHALL BE LAB <br />TESTED PER ASTM C157 FOR EACH MIX DESIGN AND AGGREGATE SOURCE. <br />13. WHERE SPECIFIED, AIR CONTENT SHALL BE SAMPLED AT THE POINT OF DISCHARGE AND FIELD TESTED PER ASTM C231, <br />PRESSURE METHOD. <br />14. UNLESS OTHERWISE SPECIFIED, CONCRETE SHALL HAVE A MAXIMUM SLUMP OF 5 INCHES WITHOUT ADMIXTURES, AND A <br />MAXIMUM OF 8 INCHES WHERE WATER REDUCTION OR SUPERPLASTICIZER ADMIXTURES ARE USED. SLUMP SHALL BE <br />MEASURED PER ASTM C143 AT THE POINT OF DELIVERY WITH TOLERANCES PER ASTM C94. SELF CONSOLIDATING <br />CONCRETE SHALL HAVE A MAXIMUM SPREAD OF 26 INCHES AS MEASURED PER ASTM C1611. <br />15. FOR LIGHT WEIGHT CONCRETE SLABS AND FILL OVER DECK, MAXIMUM AIR CONTENT SHALL BE 3 PERCENT AND MAXIMUM <br />SLUMP SHALL BE 5 INCHES, MEASURED WITH ADMIXTURES. <br />16. USE PLACEMENT AND FINISHING PROCEDURES THAT PREVENT DELAMINATION, BLISTERING OR OTHER SURFACE <br />DEFECTS. <br />17. NONSHRINK OR DRYPACK GROUT SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 5000 PSI, AND SHALL BE <br />MASTERFLOW 713, EUCON NS GROUT, SIKA GROUT 212, OR APPROVED EQUAL. FOR THICK GROUT LAYERS AND LARGE <br />VOLUME PLACEMENTS FOLLOW MANUFACTURER’S GUIDELINES, WHICH MAY INCLUDE THE ADDITION OF WASHED <br />COARSE AGGREGATE AND POUR SEQUENCING. UNDER BASE PLATES LARGER THAN 6 SQUARE FEET, USE MASTERFLOW <br />928 OR OTHER APPROVED HI-FLOW GROUT. <br />18. THE USE OF CONSTRUCTION JOINTS (CJ) AT LOCATIONS NOT SHOWN ON THE PLANS AND DETAILS SHALL BE APPROVED <br />BY THE SEOR PRIOR TO PLACEMENT OF CONCRETE. CJ’S SHALL BE USED WHENEVER CONCRETE PLACEMENT IS <br />INTERRUPTED FOR MORE THAN 30 MINUTES. HORIZONTAL/FLAT CJ’S MAY BE UNFORMED, VERTICAL CJ’S SHALL BE FULLY <br />FORMED WITH SHEAR KEYS. CJ’S SHALL BE CLEANED, LAITANCE REMOVED, AND ROUGHENED TO AN AMPLITUDE OF 1/4 <br />INCH BY REMOVING THE ENTIRE SURFACE TO EXPOSE CLEAN AGGREGATE SOLIDLY EMBEDDED IN THE MORTAR MATRIX. <br />IMMEDIATELY BEFORE NEW CONCRETE IS PLACED CJ’S SHALL BE WETTED AND STANDING WATER REMOVED. <br />19. PIPES, DUCTS OR CONDUIT SHALL NOT BE PLACED IN STRUCTURAL CONCRETE UNLESS SPECIFICALLY DETAILED ON THE <br />STRUCTURAL DRAWINGS. PROVIDE SLEEVES FOR ALL PIPES THROUGH CONCRETE WALLS AND FOOTINGS. <br />20. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ALL MOULDS, REVEALS, GROOVES, CHAMFERS, DRIPS, <br />ORNAMENTS AND OTHER FINISH REQUIREMENTS. UNLESS OTHERWISE NOTED, EXPOSED CORNERS OF SLABS, BEAMS, <br />WALLS, COLUMNS, ETC. SHALL BE FORMED WITH 3/4 INCH CHAMFER STRIPS OR 1/2 INCH RADIUS TOOLED EDGE. <br />21. ALL DOWELS, ANCHORS AND OTHER EMBEDMENTS TO BE SET IN CONCRETE OR GROUT SHALL BE SECURED IN POSITION <br />PRIOR TO PLACEMENT, NO WET SETTING, STABBING, RODDING OR OTHER MOVEMENT OF EMBEDDED ITEMS SHALL BE <br />ALLOWED. THE CONTRACTOR SHALL COORDINATE WITH CONTRACT DOCUMENTS AND DISCIPLINES ITEMS SUCH AS; <br />REINFORCEMENT, ANCHORS, INSERTS, HANGERS, NOSING, GUARDS, ELECTRICAL GROUNDS, INTEGRAL FRAMES, ETC. <br />22. CONCRETE AND GROUT MAINTAINED BETWEEN 50 TO 90 DEGREES FAHRENHEIT AND IN A MOIST, WIND SHELTERED <br />CONDITION FOR A MINIMUM OF 7 DAYS AFTER PLACEMENT DOES NOT REQUIRE A WRITTEN PROTECTION PLAN. WHERE <br />REQUIRED BY WEATHER AND SITE CONDITIONS, THE CONTRACTOR SHALL FOLLOW AN APPROVED COLD- OR HOT- <br />WEATHER PROTECTION PLAN COMPLYING WITH ACI 306.1 / 301. <br />23. PRIOR TO ERECTING ANY ELEMENTS THAT LOAD THE FOUNDATION, CONCRETE MUST REACH AN UNCONFINED <br />COMPRESSION STRENGTH OF 2000 PSI MINIMUM AS DETERMINED BY CYLINDER TESTING, AND MUST BE ALLOWED TO <br />CURE FOR A MINIMUM OF 3 DAYS. <br />24. REVIEW MANUFACTURER REQUIREMENTS FOR OVERLAYMENTS, FINISHES AND FLOORING SYSTEMS TO BE APPLIED TO <br />CONCRETE AS THESE MAY BE MORE RESTRICTIVE. <br />25. STYROFOAM VOID FILLER SHALL BE A DOW BUILDING SOLUTIONS PRODUCT “BLUE BOARD” TYPE OR APPROVED EQUAL <br />WITH PROPERTIES APPROPRIATE FOR THE CONDITIONS OF USE. <br />CONCRETE SCHEDULE NOTES: <br />1. PORTLAND CEMENT TYPE. <br />2. INDICATES NORMAL WEIGHT CONCRETE (NWC). OR SAND LIGHT WEIGHT CONCRETE (LWC). <br />3. MINIMUM 28-DAY CYLINDER COMPRESSIVE STRENGTH IN PSI. <br />4. MAXIMUM WATER TO CEMENTITIOUS MATERIAL RATIO, INCLUDING FREE <br />MOISTURE ON AGGREGATES. <br />* 0.45 MAXIMUM W/C RATIO REQUIRED FOR CONCRETE RECEIVING ADHESIVE FINISHES. <br />5. MAXIMUM AGGREGATE SIZE, SEE ACI 318 FOR ADDITIONAL REQUIREMENTS INCLUDING GRADATION. <br />6. MAXIMUM SHRINKAGE AT 28 DAYS. <br />0.05% <br />654321 <br />STRUCTURAL CONCRETE SCHEDULE <br />SHRINKAGE <br />- <br />0.05% <br />0.05% <br />NEW WALL <br />IN-FILLS <br />ALL OTHER <br />CONCRETE <br />AGG SIZEW/C RATIOSTRENGTHTYPECEMENT LOCATION <br />1 1/2”0.454500NWCIIFOUNDATIONS <br />1” 0.45 SLAB-ON-GRADE NWC II 4500 <br />NEW WALLS 1" 0.454000NWCII <br />1"0.45 3000NWCII <br />-1"0.553000NWCII <br />0.05%FILL OVER METAL <br />DECK 1" 0.453000LWCII <br />0.05%RAISED SLABS & <br />BEAMS 1" 0.454000NWCII <br />POST INSTALLED ANCHORS <br />1. UNLESS OTHERWISE NOTED ON THE DRAWINGS, THE FOLLOWING APPLIES TO ALL POST INSTALLED ANCHORAGE INTO <br />HARDENED CONCRETE OR MASONRY WHICH INCLUDES TYPES SUCH AS EXPANSION, WEDGE, SLEEVE, ADHESIVE/EPOXY, <br />SHOT-PIN, SCREW AND UNDERCUT. <br />2. INSTALL PER THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS (MPII) EXCEPT AS OTHERWISE STATED IN THE <br />SPECIFIED PRODUCT REPORTS. USE INSTALLATION PROCEDURES FOR CRACKED CONCRETE CONDITIONS. DO NOT USE <br />CORE DRILL BITS FOR ANCHOR HOLES WITHOUT PRIOR SEOR APPROVAL. COPIES OF INSTALLATION INSTRUCTIONS SHALL <br />BE MAINTAINED ON SITE. <br />3. PROVIDE GALVANIZED CARBON STEEL ANCHORS AT DRY INTERIOR LOCATIONS AND STAINLESS STEEL TYPE 304 OR 316 AT <br />EXTERIOR / DAMP INTERIOR LOCATIONS. DOWELS TO RECEIVE CONCRETE COVER MAY BE PLAIN CARBON STEEL. <br />ANCHORS SHALL BE CLEAN AND FREE OF DEBONDING SUBSTANCES. <br />4. UNLESS OTHERWISE NOTED, THE SPECIFIED EMBEDMENT REFERS TO THE FINAL INSTALLED EFFECTIVE DEPTH “Hef” AS <br />DEFINED IN THE PRODUCT REPORT. MINIMUM ANCHOR HOLE DEPTH FOR INSTALLATION MAY BE DEEPER. FOR EXPANSION <br />ANCHORS PROVIDE A MINIMUM ANCHOR HOLE DEPTH PER THE MPII, BUT NOT LESS THAN THE SPECIFIED EMBEDMENT + <br />THE SMALLER OF 1.5x DIAM OR 1 INCH. WHERE EMBEDMENT IS NOT SPECIFIED, PROVIDE AN EMBEDMENT DEPTH OF THE <br />SMALLER OF 8 TIMES THE ANCHOR DIAMETER AND 2/3 THE THICKNESS OF THE MEMBER THE ANCHOR IS PLACED INTO. <br />5. MAINTAIN A MINIMUM OF 2 INCHES FROM EXISTING REINFORCEMENT, CONDUIT, POST TENSIONING (WHERE OCCURS), ETC. <br />PRIOR TO DRILLING, CORING OR SHOOTING PINS INTO EXISTING CONCRETE OR MASONRY USE NON DESTRUCTIVE TESTING <br />TO LOCATE SUCH ITEMS. FOR INSTALLATION DEEPER THAN 3 INCHES USE GROUND PENETRATING RADAR OR X-RAY <br />METHODS. <br />6. WHERE THE SPECIFIED ANCHOR EMBEDMENT DEPTH, SPACING OR EDGE DISTANCE CANNOT BE PROVIDED, NOTIFY THE <br />SEOR AND lOR. <br />7. PATCH ABANDONED HOLES AND SPALLS USING NON-SHRINK GROUT AND REPAIR FINISHES AS REQUIRED. ANCHORS <br />PENETRATING THROUGH WATER PROOFING OR VAPOR MEMBRANES SHALL BE SEALED OR FLASHED. <br />8. INSTALL IN DRY CONCRETE OR MASONRY HAVING A MINIMUM AGE OF 21 DAYS UNLESS SPECIFICALLY APPROVED BY THE <br />SEOR. <br />9. ADHESIVE/EPOXY ANCHORS ON THIS PROJECT ARE NOT DESIGNED TO SUPPORT, OR INTENDED TO RESIST SUSTAINED <br />TENSION LOADS. <br />10. INSTALLERS PLACING OVERHEAD ADHESIVE ANCHORS SHALL BE CERTIFIED BY ACI OR APPROVED EQUIVALENT. <br />DO NOT PLACE POST INSTALLED ANCHORS IN CMU WITHIN 1 1/2” OF HEAD JOINTS OR INTO UNGROUTED CELLS UNLESS <br />SPECIFICALLY INDICATED ON THE STRUCTURAL DOCUMENTS. <br />STRUCTURAL CONCRETE CONT <br />No. 6250 <br />FFOHSIB <br />RYAN W. <br />REGISTEREDPROFESSIONALENGINEER <br />STRUCTURALSTATEOFCALIFORNIA <br />DATE: <br />FOR BRANDOW & JOHNSTON <br />STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) <br />3300 IRVINE AVE. SUITE 245 <br />NEWPORT BEACH, CALIFORNIA 92660 <br />T:(949)862-8500 WWW.BJSCE.COM <br />JOB#: <br />1 <br />7 <br /> <br />8 <br /> <br />8 <br /> <br />0 <br /> <br /> <br />S <br /> <br />k <br /> <br />y <br /> <br /> <br />P <br /> <br />a <br /> <br />r <br /> <br />k <br /> <br /> <br />C <br /> <br />i <br /> <br />r <br /> <br />c <br /> <br />l <br /> <br />e <br /> <br />, <br /> <br /> <br />S <br /> <br />u <br /> <br />i <br /> <br />t <br /> <br />e <br /> <br />2 <br /> <br />3 <br /> <br />0 <br /> <br /> <br />- <br />I <br />r <br /> <br />v <br /> <br />i <br /> <br />n <br /> <br />e <br /> <br />, <br /> <br /> <br />C <br /> <br />A <br /> <br /> <br />9 <br /> <br />2 <br /> <br />6 <br /> <br />1 <br /> <br />4 <br />t <br /> <br />e <br /> <br /> <br />l <br /> <br /> <br /> <br />9 <br /> <br /> <br />4 <br /> <br /> <br />9 <br /> <br /> <br /> <br />. <br /> <br /> <br /> <br />5 <br /> <br /> <br />5 <br /> <br /> <br />3 <br /> <br /> <br /> <br />. <br /> <br /> <br /> <br />8 <br /> <br /> <br />9 <br /> <br /> <br />0 <br /> <br /> <br />0 <br />a <br />r <br /> <br />c <br /> <br />h <br /> <br />i <br /> <br />t <br /> <br />e <br /> <br />c <br /> <br />t <br /> <br />u <br /> <br />r <br /> <br />e <br /> <br />i <br /> <br />n <br /> <br />t <br /> <br />e <br /> <br />r <br /> <br />i <br /> <br />o <br /> <br />r <br /> <br /> <br />d <br /> <br />e <br /> <br />s <br /> <br />i <br /> <br />g <br /> <br />n <br />p <br />l <br /> <br />a <br /> <br />n <br /> <br />n <br /> <br />i <br /> <br />n <br /> <br />g <br />DA <br />I <br />M <br />L <br />E <br />R <br /> <br />A <br />C <br />P <br />L <br />30 <br />0 <br />9 <br /> <br />D <br />A <br />I <br />M <br />L <br />E <br />R <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br /> <br />9 <br />2 <br />7 <br />9 <br />5 <br />S0.2 <br />GENERAL NOTES <br />07/23/24 <br />NO. REMARKS DATE <br />60% COMPLETE SET 05/28/24 <br />90% COMPLETE SET 07/12/24 <br />ISSUE FOR BID 07/16/24 <br />CITY SUBMITTAL 07/23/24 <br />3009 S Daimler St <br />11/18/2024