MAIN RUNNERS <br />2'x4' FIXTURE <br />6" MAX <br />LST-BAR LAYIN SUPPORT DETAIL N.T.S. <br />SCALE <br />#12 AWG STEEL WIRE CONNECTOR <br />ATTACH TO PERMANENT STRUCTURE <br />TYP. 4 PLACES <br />TEX SCREW <br />OPPOSITE CORNERS <br />MAIN RUNNERS <br />TYPICAL FOR 2'X2' OR 2'X4' FIXTURE <br />COORDINATE EXACT MOUNTING REQUIREMENTS WITH ARCHITECTURAL AND <br />STRUCTURAL. COMPLY WITH ALL APPLICABLE CODES AND STANDARDS. <br />GFCI RECEPTACLE WITH EXTRA <br />DUTY WHILE IN USE WEATHERPROOF <br />ENCLOSURE <br />8" <br />ROOF <br />WEATHERPROOF BOX <br />3/4" MINIMUM RGS CONDUIT <br />ROOF RECEPTACLE PENETRATION RRN.T.S. <br />SCALE <br />ROOF JACK WITH WEATHERPROOF SEAL <br />COORDINATE PENETRATION AND <br />MOUNTING WITH ARCHITECT, <br />STRUCTURAL AND ROOFER. <br />REMARKSNO.DATE <br />ar <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br />in <br />t <br />e <br />r <br />i <br />o <br />r <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />pl <br />a <br />n <br />n <br />i <br />n <br />g <br />17 <br />8 <br />8 <br />0 <br /> <br />S <br />k <br />y <br /> <br />P <br />a <br />r <br />k <br /> <br />C <br />i <br />r <br />c <br />l <br />e <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />2 <br />3 <br />0 <br /> <br />- <br /> <br />I <br />r <br />v <br />i <br />n <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />1 <br />4 <br />t <br />e <br />l <br /> <br />9 <br />4 <br />9 <br />. <br />5 <br />5 <br />3 <br />. <br />8 <br />9 <br />0 <br />0 <br />Ed <br />w <br />a <br />r <br />d <br />s <br />DA <br />I <br />M <br />L <br />E <br />R <br /> <br />A <br />C <br />P <br />L <br />30 <br />0 <br />9 <br /> <br />D <br />A <br />I <br />M <br />L <br />E <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />23 <br />2 <br />7 <br />6 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />P <br />O <br />I <br />N <br />T <br />E <br /> <br />D <br />R <br />. <br />, <br /> <br />U <br />N <br />I <br />T <br />1 <br />0 <br />2 <br />, <br />LA <br />G <br />U <br />N <br />A <br /> <br />H <br />I <br />L <br />L <br />S <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />5 <br />3 <br />O: <br /> <br />9 <br />4 <br />9 <br />- <br />4 <br />1 <br />9 <br />- <br />9 <br />9 <br />0 <br />8 <br /> <br />F <br />: <br /> <br />9 <br />4 <br />9 <br />- <br />4 <br />1 <br />9 <br />- <br />9 <br />8 <br />7 <br />0 <br />E6.1 <br />EQUIPMENT SCHEDULE <br />AND DETAILS <br />THE EQUIPMENT SCHEDULE IS DEVELOPED BY OTHERS, IS SHOWN FOR REFERENCE <br />ONLY, AND IS THE BASIS OF THESE DRAWINGS. CONTRACTOR SHALL VERIFY <br />EQUIPMENT REQUIREMENTS PRIOR TO INSTALL AND SHALL NOTIFY THE ENGINEER <br />OF VARIATIONS. FOR BUSWAY CONNECTED DEVICES, PROVIDE THE APPROPRIATE <br />PLUG-IN UNIT. COORDINATE ADDITIONAL PLUG-IN DEVICES WITH EDWARDS. <br />GENERAL NOTES: <br />1.DETAIL IS GENERAL IN NATURE. <br />2.PROVIDE BUSWAY AND PLUG-IN UNITS PER PLANS. <br />3.PROVIDE ALL REQUIRED EQUIPMENT, CONNECTORS, <br />MOUNTING HARDWARE, ETC., TO PROVIDE A <br />COMPLETE, CODE COMPLIANT AND OPERABLE <br />SYSTEM. COORDINATE WITH STRUCTURAL. <br />PLUG-IN BUSWAY GENERAL DETAIL PBWN.T.S. <br />SCALE <br />6'-0" <br />AFF <br />10'-0" <br />AFF <br />STRUCTURAL CEILING <br />FINISHED FLOOR <br />PLUG-IN BUSWAY PLUG-IN UNIT WITH <br />CIRCUIT BREAKER <br />RATED FOR DEVICE <br />FLEXIBLE CORD DROP <br />WITH STRAIN RELIEF <br />RECEPTACLE OR <br />CONNECTION DEVICE <br />VERIFY IN FIELD <br />END POWER FEED <br />WITH IR SCAN WINDOW <br />PROVIDE UNISTRUT <br />SUPPORT PER STRUCTURAL <br />BUSWAY SUPPORTS <br />PER STRUCTURAL WITH <br />SEISMIC SUPPORTS <br />EVERY 5FT <br />ACOUSTIC CEILING TILE <br />CUT HOLE IN CEILING FOR <br />SUPPORTS & CONDUIT, <br />INSTALL GROMMETS <br />3009 S Daimler St <br />11/18/2024