My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2515 & 2517 N Cotter St - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Cotter St
>
2517 N Cotter St
>
2515 & 2517 N Cotter St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:14 PM
Creation date
6/6/2025 1:18:27 PM
Metadata
Fields
Template:
Plan
Permit Number
101120876
101120877
101120878
Full Address
2517 N Cotter St
2515 N Cotter St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 2 <br /> <br />Note to the geotechnical report reviewer: Please see the actual full-scale plans prepared <br />by the architect/designer/civil engineer which are separately submitted to the City for <br />review, for clarification/details of the proposed development, as needed. <br /> <br />The site is relatively flat; and we understand that additional raw cut/raw fill is not <br />proposed for the site. <br /> <br />Geotechnical Conditions <br /> <br />Based on the published geologic map prepared by the California Division of Mines and <br />Geology (CDMG), the site is located within a broad flat alluvium and colluvium area. <br /> <br />Based on the State of California SEISMIC HAZARD ZONES Map, Anaheim <br />Quadrangle, the subject site is located within a potential liquefaction zone. For <br />conservative purposes, we assume that the site will be subjected to the liquefaction; and <br />to mitigate the potential adverse effects due to potential liquefaction, as for other recent <br />near-by projects, a strengthened foundation system is recommended to be used for the <br />proposed new structure. <br /> <br />To verify the near ground surface soils, a 5 ft. deep test hole has been drilled using a <br />hand-held drilling tool and soil samples were collected for laboratory testing. The <br />approximate location of the test hole is depicted on the Site Plan / Geotechnical Map. The <br />geotechnical boring log and summary of results of the laboratory testing are included in <br />Appendix B. <br /> <br />Based on the data of our test hole, the near ground surface earth materials generally <br />consisted of silty fine sand with very minor clay and some gravel, damp to moist, <br />medium dense and have a very low expansion potential. <br /> <br />Groundwater <br /> <br />Free standing groundwater was not encountered in our test hole. <br /> <br />Free standing ground water was not reported to be an issue at the site and in the vicinity. <br /> <br />Deep footings/excavations are not proposed for the site; therefore adverse effects due to <br />groundwater are not anticipated for the proposed development. <br /> <br />Note: it is not anticipated; however, if wet soils are encountered, removal of the wet soils <br />and replacement with drier soils/cement slurry can be performed. In addition, if needed, <br />crushed rock and or geogrids for bridging, etc. can also be used. This will be determined <br />by the geotechnical consultant based on the exposed conditions during the excavations at <br />the site. <br /> <br />Seismicity <br /> <br />2515 & 2517 N <br />Cotter St5/1/2025
The URL can be used to link to this page
Your browser does not support the video tag.