My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2515 & 2517 N Cotter St - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Cotter St
>
2517 N Cotter St
>
2515 & 2517 N Cotter St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:14 PM
Creation date
6/6/2025 1:18:27 PM
Metadata
Fields
Template:
Plan
Permit Number
101120876
101120877
101120878
Full Address
2517 N Cotter St
2515 N Cotter St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 9 <br /> <br />In general, proper surface drainage should be checked, improved as needed, and <br />maintained to ensure surface water flows away from all structures. Requirements by the <br />city and applicable CBC (2022 CBC) should also be followed. <br /> <br />Roof gutters should be properly provided. Roof drains, gutters and downspouts should be <br />maintained to function as intended. Outlet drains should be kept open. <br /> <br />Irrigation at the site, if any, should be kept to a minimum required to support plant life. <br /> <br />In the future, sources of uncontrolled water, such as leaky sewer, water (domestic, <br />irrigation) or drainpipe, should be repaired if identified. <br /> <br />Seismic Design <br /> <br />We recommend the proposed new structure be structurally designed to meet the <br />applicable building codes and requirements of the controlling governmental agencies. <br />The seismic parameters provided in the “Seismicity” section of this report can be used. <br />The civil/structural design engineer should consult with the project geotechnical <br />consultant, if additional geotechnical information is needed for the seismic design. <br /> <br />Cement Type For Concrete in Contact with On-Site Earth Materials <br /> <br />Our previous tests performed on the soils of many lots in the City of Santa Ana which are <br />similar to the on-site soils show negligible water-soluble sulfate contents. Sulfate attack <br />on concrete was not observed for the existing on-site house and other houses in the <br />surrounding areas. It appears sulfate attack on concrete is not considered to be a problem <br />for this project. However, for conservative purpose, Type V cement with a maximum <br />water/cement ratio of 0.45 and a minimum concrete strength, f'c of 4,500 psi is <br />recommended to be used for concrete in contact with the on-site soils. Additional water- <br />soluble sulfate content testing can be performed for the soils at the site, as needed. The <br />test can be conducted during and/or after completion of site preparation/grading. <br /> <br />The applicable California Building Code (2022 CBC) and other requirements by <br />controlling governmental agencies should be followed. <br /> <br />Corrosion To Ferrous Metals and Copper <br /> <br />For conservative purposes, the on-site soils can be considered severely corrosive to <br />ferrous metals and copper. Underground/buried ferrous metals or copper are not planned <br />to be used for this project. However, if underground/buried ferrous metals or copper are <br />planned to be used at the site, they should be properly protected. A corrosion specialist <br />can be consulted. Testing can be performed for verification of the potential corrosion of <br />the soils at the site to ferrous metals and copper, if needed. The test can be performed <br />during and/or after completion of grading. <br /> <br />2515 & 2517 N <br />Cotter St5/1/2025
The URL can be used to link to this page
Your browser does not support the video tag.