My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2209 N Linwood Ave - Plan
PBA
>
Building
>
ProjectDox
>
L
>
Linwood Ave
>
2209 N Linwood Ave
>
2209 N Linwood Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:12 PM
Creation date
6/6/2025 1:18:33 PM
Metadata
Fields
Template:
Plan
Permit Number
20183324
20184831
Full Address
2209 N Linwood Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Powerwall 3 <br />Power Everything <br />2023 <br />— <br />Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. <br />Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their <br />own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to <br />customize system behavior to meet their energy goals. <br />Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has <br />the ability to start heavy loads up to 150 A LRA, meaning a single unit can support the power needs of most homes. Powerwall <br />3 is designed for mass production, fast and efficient installations, easy system expansion, and simple connection to any <br />electrical service. <br />22023Powerwall 3 Datasheet <br />Solar Technical <br />Specifications <br />Maximum Solar STC Input 20 kW <br />Withstand Voltage 600 V DC <br />PV DC Input Voltage Range 60 — 550 V DC <br />PV DC MPPT Voltage Range 150 — 480 V DC <br />MPPTs 6 <br />Maximum Current per MPPT (Imp)13 A 5 <br />Maximum Short Circuit Current per MPPT (Isc)15 A 5 <br />Powerwall 3 Technical Specifications <br />1 Typical solar shifting use case. <br />2 Values provided for 25°C (77°F), at beginning of life. 3.3 kW charge/discharge power. <br />3 Tested using CEC weighted efficiency methodology. <br />4 Cellular connectivity subject to network service coverage and signal strength. <br />5 Where the DC input current exceeds the MPPT rating, a jumper can be used to combine two MPPTs into a single <br />input to intake DC current up to 26 A IMP / 30 A ISC. <br />Battery Technical <br />Specifications <br />Nominal Battery Energy 13.5 kWh AC 2 <br />Maximum Continuous Discharge Power 11.5 kW AC <br />Maximum Continuous Charge Power 5 kW AC <br />Output Power Factor Rating 0 - 1 (Grid Code configurable) <br />Maximum Continuous Current 48 A <br />Load Start Capability (1 s)150 A LRA <br />Power Scalability Up to 4 Powerwall 3 units supported <br />System Technical <br />Specifications <br />Model Number 1707000-xx-y <br />Nominal Grid Voltage 120/240 V AC <br />Grid Configuration Split phase <br />Grid Frequency 60 Hz <br />Overcurrent Protection Device Configurable up to 60 A <br />Solar to Battery to Grid Round Trip Efficiency 89% 1,2 <br />Solar to Grid Efficiency 97% 3 <br />Supported Islanding Devices Backup Gateway 2, Backup Switch <br />Connectivity Wi-Fi (2.4 and 5 GHz), Dual-port switched Ethernet, <br />Cellular (LTE/4G 4) <br />Hardware Interface Dry contact relay, Rapid Shutdown (RSD) certified <br />switch and 2-pin connector, RS-485 for meters <br />AC Metering Revenue Grade (+/- 0.5%) <br />Protections Integrated arc fault circuit interrupter (AFCI), <br />Isolation Monitor Interrupter (IMI), PV Rapid <br />Shutdown (RSD) using Tesla Mid-Circuit Interrupters <br />Customer Interface Tesla Mobile App <br />Warranty 10 years <br />2209 N Linwood <br />Ave8/22/2024
The URL can be used to link to this page
Your browser does not support the video tag.