My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2209 N Linwood Ave - Plan
PBA
>
Building
>
ProjectDox
>
L
>
Linwood Ave
>
2209 N Linwood Ave
>
2209 N Linwood Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:12 PM
Creation date
6/6/2025 1:18:33 PM
Metadata
Fields
Template:
Plan
Permit Number
20183324
20184831
Full Address
2209 N Linwood Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
32023Powerwall 3 Datasheet <br />Mechanical <br />Specifications <br />Dimensions 1105 x 609 x 193 mm (43.5 x 24 x 7.6 in) <br />Weight 130 kg (287 lb) <br />Mounting Options Floor or wall mount <br />Powerwall 3 Technical Specifications <br />Environmental <br />Specifications <br />Operating Temperature –20°C to 50°C (–4°F to 122°F) 6 <br />Operating Humidity (RH)Up to 100%, condensing <br />Storage Temperature –20°C to 30°C (–4°F to 86°F), up to 95% RH, non- <br />condensing, State of Energy (SOE): 25% initial <br />Maximum Elevation 3000 m (9843 ft) <br />Environment Indoor and outdoor rated <br />Enclosure Rating NEMA 3R <br />Ingress Rating IPX7 (Battery & Power Electronics) <br />IPX5 (Wiring Compartment) <br />Pollution Rating PD3 <br />Operating Noise @ 1 m <50 db(A) typical <br /><62 db(A) maximum <br />Compliance <br />Information <br />Certifications UL 1642, UL 1699B, UL 1741ȑȆȍȊȆˏ, <br />UL 1741 SA, UL 1741 SB, UL 3741, UL 1973, UL 1998, <br />UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3 <br />Grid Connection United States <br />Emissions FCC Part 15 Class B <br />Environmental RoHS Directive 2011/65/EU <br />Seismic AC156, IEEE 693-2005 (high) <br />Fire Testing Meets the unit level performance criteria <br />of UL 9540A <br />6 Performance may be de-rated at operating temperatures above 40°C (104°F). <br />609 mm <br />1105 mm <br />193 <br />mm <br />42023Powerwall 3 Datasheet <br />Electrical <br />Specifications <br />Model MCI-1 MCI-2 <br />Nominal Input DC Current Rating (IMP)12 A 13 A <br />Maximum Input Short Circuit Current (ISC)19 A 17 A <br />Maximum System Voltage (PVHCS)600 V DC 1000 V DC 7 <br />Solar Shutdown Device Technical Specifications <br />Environmental <br />Specifications <br />Operating Temperature -40°C to 50°C <br />(-40°F to 122°F) <br />-45°C to 70°C <br />(-49°F to 158°F) <br />Storage Temperature –30°C to 70°C <br />(–22°F to 158°F) <br />–30°C to 70°C <br />(–22°F to 158°F) <br />Enclosure Rating NEMA 4X / IP65 NEMA 4X / IP65 <br />RSD Module <br />Performance <br />Maximum Number of Devices per String 5 5 <br />Control Power Line Excitation Power Line Excitation <br />Passive State Normally Open Normally Open <br />Maximum Power Consumption 7 W 7 W <br />Warranty 25 years 25 years <br />— <br />The Solar Shutdown Device is a Mid-Circuit Interrupter (MCI) and is part of the PV system rapid shutdown (RSD) function in <br />accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss of <br />AC power. <br />Mechanical <br />Specifications <br />Electrical Connections MC4 Connector MC4 Connector <br />Housing Plastic Plastic <br />Dimensions 125 x 150 x 22 mm <br />(5 x 6 x 1 in) <br />173 x 45 x 22 mm <br />(6.8 x 1.8 x 1 in) <br />Weight 350 g (0.77 lb) 120 g (0.26 lb) <br />Mounting Options ZEP Home Run Clip <br />M4 Screw (#10) <br />M8 Bolt (5/16") <br />Nail / Wood screw <br />Wire Clip <br />UL 3741 PV Hazard Control (and PVRSA) Compatibility <br />The following categories of solar module meet the UL 3741 PVHCS listing when installed with Powerwall 3 and Solar Shutdown <br />Devices. <br />Tesla Solar Roof PV Hazard Control System: BIPV compliance document <br />Tesla or Hanwha (Q.Peak Duo BLK or BLK-G6+) <br />Modules certified for use with ZEP racking PV Hazard Control System: ZS PVHCS compliance document <br />Other module and racking combinations PV Hazard Control System: Generic PV Array compliance document <br />Compliance <br />Information <br />Certifications UL 1741 PVRSE, UL 3741, <br />PVRSA (Photovoltaic Rapid Shutdown Array) <br />RSD Initiation Method External System Shutdown Switch or <br />Powerwall 3 Enable Switch <br />7 Maximum System Voltage is limited by Powerwall to 600 V DC. <br />2209 N Linwood <br />Ave8/22/2024
The URL can be used to link to this page
Your browser does not support the video tag.