Laserfiche WebLink
COLD AND HOT WATER FLOOR PLAN <br />2 <br />En <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br /> <br />P <br />l <br />a <br />n <br />n <br />i <br />n <br />g <br /> <br /> <br />T <br />i <br />t <br />l <br />e <br /> <br />2 <br />4 <br />© <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />, <br /> <br />N <br />i <br />k <br />a <br />n <br /> <br />D <br />e <br />s <br />i <br />g <br />n <br /> <br />G <br />r <br />o <br />u <br />p <br />. <br /> <br /> <br />i <br />n <br />c <br />. <br />, <br /> <br />a <br /> <br />C <br />a <br />l <br />i <br />f <br />o <br />r <br />n <br />i <br />a <br /> <br />c <br />o <br />r <br />p <br />o <br />r <br />a <br />t <br />i <br />o <br />n <br />, <br /> <br />A <br />L <br />L <br /> <br />R <br />I <br />G <br />H <br />T <br />S <br /> <br />R <br />E <br />S <br />E <br />R <br />V <br />E <br />D <br />Title 24 Experts <br />Nikan Design Group <br />Inc. <br />7518 Jumilla Ave. <br />Winnetka, CA 91306 <br />818-561-9333 <br />20 <br />2 <br />3 <br />Title 24 Compliance: <br />Nikan Design Group <br />Inc. (Title 24 Experts) <br />7518 Jumilla Ave. <br />Winnetka, CA 91306 <br />818-561-9333 <br />Client: <br />Project Name: <br />DRAWN BY: <br />MARAL RAHMANI <br /> <br />T24.1 <br />TITLE 24 <br />COMPLIANCE <br /> <br />Project Number: <br />75-240304-04 <br /> Issue Date: 03/04/2024 <br />PLAN AND PERMIT INC. <br />ARCHITECTURAL DESIGN SERVICES <br />9891 IRVINE CENTER DR #200 <br />IRVINE, CA 92618 <br />(714)-715-0923 <br />biz@planandpermit.com <br />PROPERTY OWNER: <br />PETERSON RESIDENCE <br />1908 GREENLEAF ST. <br />SANTA ANA, CA <br />92706 <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:PETERSON RESIDENCE Calculation Date/Time:2024-10-07T21:40:23-07:00 (Page 1 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:1908 GREENLEAF UNIT 2_T24.ribd22x <br />Registration Number:Registration Date/Time:    HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-10-07   21:40:43 <br />GENERAL INFORMATION <br />01 Project Name PETERSON RESIDENCE <br />02 Run Title Title 24 Analysis <br />03 Project Location 1908 GREENLEAF ST. UNIT 2 <br />04 City SANTA ANA 05 Standards Version 2022 <br />06 Zip code 92706 07 Software Version EnergyPro 9.3 <br />08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)90 <br />10 Building Type Single family 11 Number of Dwelling Units 1 <br />12 Project Scope Addition and/or Alteration 13 Number of Bedrooms 1 <br />14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 2 <br />16 Existing Cond. Floor Area (ft2)1357 17 Fenestration Average U-factor 0.3 <br />18 Total Cond. Floor Area (ft2)1357 19 Glazing Percentage (%)8.40% <br />20 ADU Bedroom Count 1 21 ADU Conditioned Floor Area 894 <br />22 Fuel Type Natural gas 23 No Dwelling Unit:No <br />COMPLIANCE RESULTS <br />01 Building Complies with Computer Performance <br />02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. <br />03 Building does not incorporate Special Features <br />424-P010240138A-000-000-0000000-0000 10/07/2024 21:57 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:PETERSON RESIDENCE Calculation Date/Time:2024-10-07T21:40:23-07:00 (Page 2 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:1908 GREENLEAF UNIT 2_T24.ribd22x <br />Registration Number:Registration Date/Time:    HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-10-07   21:40:43 <br />ENERGY USE SUMMARY <br />Energy Use Standard Design Source <br />Energy (EDR1) (kBtu/ft2 -yr) <br />Standard Design TDV Energy <br />(EDR2) (kTDV/ft2 -yr) <br />Proposed Design Source <br />Energy (EDR1) (kBtu/ft2 -yr) <br />Proposed Design TDV Energy <br />(EDR2) (kTDV/ft2 -yr) <br />Compliance <br />Margin (EDR1) <br />Compliance <br />Margin (EDR2) <br />Space Heating 0 3.96 0 5.15 0 -1.19 <br />Space Cooling 0 24.11 0 21.96 0 2.15 <br />IAQ Ventilation 0 2.51 0 2.51 0 0 <br />Water Heating 0 43.3 0 42.17 0 1.13 <br />Self <br />Utilization/Flexibility <br />Credit <br />0 0 <br />Efficiency Compliance <br />Total 0 73.88 0 71.79 0 2.09 <br />Photovoltaics 0 0 <br />Battery 0 <br />Flexibility <br />Indoor Lighting 0 7.29 0 7.29 <br />Appl. & Cooking 0 45.71 0 45.65 <br />Plug Loads 0 27.1 0 27.1 <br />Outdoor Lighting 0 1.69 0 1.69 <br />TOTAL COMPLIANCE 0 155.67 0 153.52 <br />424-P010240138A-000-000-0000000-0000 10/07/2024 21:57 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:PETERSON RESIDENCE Calculation Date/Time:2024-10-07T21:40:23-07:00 (Page 3 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:1908 GREENLEAF UNIT 2_T24.ribd22x <br />Registration Number:Registration Date/Time:    HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-10-07   21:40:43 <br />ENERGY USE INTENSITY <br />Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage <br />Gross EUI1 24.63 24.22 0.41 1.66 <br />Net EUI2 24.63 24.22 0.41 1.66 <br />Notes <br />    1. Gross EUI is Energy Use Total (not including PV) / Total Building Area. <br />    2. Net EUI is Energy Use Total (including PV) / Total Building Area. <br />REQUIRED SPECIAL FEATURES <br />The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. <br />•NO SPECIAL FEATURES REQUIRED <br />HERS FEATURE SUMMARY <br />The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional <br />detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry <br />•Indoor air quality ventilation <br />•Kitchen range hood <br />•Verified heat pump rated heating capacity <br />BUILDING - FEATURES INFORMATION <br />01 02 03 04 05 06 07 <br />Project Name Conditioned Floor Area (ft2)Number of Dwelling <br />Units Number of Bedrooms Number of Zones Number of Ventilation <br />Cooling Systems <br />Number of Water <br />Heating Systems <br />PETERSON RESIDENCE 1357 1 1 2 0 1 <br />ZONE INFORMATION <br />01 02 03 04 05 06 07 <br />Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status <br />1ST FLOOR Conditioned (N) MINI SPLIT1 894 8 DHW Sys 1 Existing Unchanged <br />424-P010240138A-000-000-0000000-0000 10/07/2024 21:57 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:PETERSON RESIDENCE Calculation Date/Time:2024-10-07T21:40:23-07:00 (Page 4 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:1908 GREENLEAF UNIT 2_T24.ribd22x <br />Registration Number:Registration Date/Time:    HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-10-07   21:40:43 <br />ZONE INFORMATION <br />01 02 03 04 05 06 07 <br />Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status <br />2ND FLOOR Conditioned (N) MINI SPLIT1 463 8 DHW Sys 1 Existing Unchanged <br />OPAQUE SURFACES <br />01 02 03 04 05 06 07 08 09 10 11 <br />Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and <br />Door Area (ft2)Tilt (deg)Wall Exceptions Status Verified Existing <br />Condition <br />NORTH Wall 1ST FLOOR R-15 Wall 0 Right 131.28 13 90 none Existing No <br />NORTH Wall 2 1ST FLOOR R-15 Wall 0 Right 57.3 4.5 90 none Existing No <br />SOUTH Wall 1ST FLOOR RATED R-15 Wall 180 Left 168 0 90 none Existing No <br />SOUTH Wall 2 1ST FLOOR R-15 Wall 180 Left 28 0 90 none Existing No <br />EAST Wall 1ST FLOOR NEW R-15 Wall 0 Right 112 44 90 none New n/a <br />WEST Wall 1ST FLOOR R-15 Wall 270 Back 72 20 90 none Existing No <br />WEST Wall 2 1ST FLOOR RATED R-15 Wall 270 Back 105 0 90 none Existing No <br />NORTH Wall 3 1ST FLOOR NEW R-15 Wall 0 Right 8 0 90 none New n/a <br />EAST Wall 2 1ST FLOOR NEW R-15 Wall 90 Front 32 4 90 none New n/a <br />EAST Wall 3 1ST FLOOR R-15 Wall 90 Front 32 0 90 none Existing No <br />NORTH Wall 4 2ND FLOOR R-15 Wall 0 Right 114.87 40 90 none Existing No <br />NORTH Wall 5 2ND FLOOR R-15 Wall 0 Right 7 0 90 none New n/a <br />NORTH Wall 6 2ND FLOOR R-15 Wall 0 Right 50.12 4.5 90 none Existing No <br />SOUTH Wall 3 2ND FLOOR R-15 Wall 180 Left 147 0 90 none Existing No <br />SOUTH Wall 4 2ND FLOOR R-15 Wall 180 Left 171.5 0 90 none Existing No <br />EAST Wall 4 2ND FLOOR R-15 Wall 90 Front 127.12 24 90 none Existing No <br />EAST Wall 5 2ND FLOOR R-15 Wall 90 Front 28 0 90 none New n/a <br />WEST Wall 3 2ND FLOOR R-15 Wall 270 Back 35 0 90 none Existing No <br />WEST Wall 4 2ND FLOOR R-15 Wall 270 Back 154 0 90 none Existing No <br />FLOOR 2ND FLOOR R-19 Floor No <br />Crawlspace n/a n/a 463 n/a n/a Existing No <br />424-P010240138A-000-000-0000000-0000 10/07/2024 21:57 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:PETERSON RESIDENCE Calculation Date/Time:2024-10-07T21:40:23-07:00 (Page 5 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:1908 GREENLEAF UNIT 2_T24.ribd22x <br />Registration Number:Registration Date/Time:    HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-10-07   21:40:43 <br />OPAQUE SURFACES - CATHEDRAL CEILINGS <br />01 02 03 04 05 06 07 08 09 10 11 12 13 14 <br />Name Zone Construction Azimuth Orientation Area <br />(ft2) <br />Skylight <br />Area (ft2) <br />Roof Rise (x <br />in 12) <br />Roof <br />Reflectance <br />Roof <br />Emittance <br />Cool <br />Roof Status <br />Verified <br />Existing <br />Condition <br />Existing <br />Construction <br />Roof 2ND FLOOR R-30 Roof No <br />Attic 90 Front 463 0 9.5 0.1 0.85 No Existing No <br />FENESTRATION / GLAZING <br />01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 <br />Name Type Surface Orientatio <br />n Azimuth Width <br />(ft) <br />Heigh <br />t (ft)Mult.Area <br />(ft2)U-factor U-factor <br />Source SHGC SHGC Source Exterior <br />Shading Status <br />Verified <br />Existing <br />Condition <br />W-3030 Window NORTH Wall Right 0 1 9 0.58 Table <br />110.6-A 0.65 Table <br />110.6-B Bug Screen Existing No <br />B-2020 Window NORTH Wall Right 0 1 4 0.3 NFRC 0.23 NFRC Bug Screen New NA <br />W-1630 Window NORTH Wall <br />2 Right 0 1 4.5 0.55 Table <br />110.6-A 0.67 Table <br />110.6-B Bug Screen Existing No <br />A-6040 SL Window EAST Wall Right 0 1 24 0.3 NFRC 0.23 NFRC Bug Screen New NA <br />B-2020 2 Window EAST Wall 2 Front 90 1 4 0.3 NFRC 0.23 NFRC Bug Screen New NA <br />D-4068 Window NORTH Wall <br />4 Right 0 1 40 0.3 NFRC 0.23 NFRC Bug Screen New NA <br />1630 FIX Window NORTH Wall <br />6 Right 0 1 4.5 0.55 Table <br />110.6-A 0.67 Table <br />110.6-B Bug Screen Existing No <br />W-6040 Window EAST Wall 4 Front 90 1 24 0.58 Table <br />110.6-A 0.65 Table <br />110.6-B Bug Screen Existing No <br />424-P010240138A-000-000-0000000-0000 10/07/2024 21:57 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:PETERSON RESIDENCE Calculation Date/Time:2024-10-07T21:40:23-07:00 (Page 6 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:1908 GREENLEAF UNIT 2_T24.ribd22x <br />Registration Number:Registration Date/Time:    HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-10-07   21:40:43 <br />OPAQUE DOORS <br />01 02 03 04 05 06 <br />Name Side of Building Area (ft2)U-factor Status Verified Existing Condition <br />Door-1 EAST Wall 20 0.2 New n/a <br />Door WEST Wall 20 0.2 Existing No <br />SLAB FLOORS <br />01 02 03 04 05 06 07 08 09 10 <br />Name Zone Area (ft2)Perimeter (ft) <br />Edge Insul. <br />R-value and <br />Depth <br />Edge Insul. <br />R-value and <br />Depth <br />Carpeted Fraction Heated Status Verified Existing <br />Condition <br />(E) <br />Slab-on-Grade 1ST FLOOR 443 90 none 0 80%No Existing No <br />(N) <br />Slab-on-Grade 1ST FLOOR 4 3 none 0 80%No New n/a <br />OPAQUE SURFACE CONSTRUCTIONS <br />01 02 03 04 05 06 07 08 <br />Construction Name Surface Type Construction Type Framing Total Cavity <br />R-value <br />Interior / Exterior <br />Continuous <br />R-value <br />U-factor Assembly Layers <br />R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 <br />Inside Finish: Gypsum Board <br />Cavity / Frame: R-15 / 2x4 <br />Exterior Finish: 3 Coat Stucco <br />RATED R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 <br />Inside Finish: Gypsum Board <br />Cavity / Frame: R-15 / 2x4 <br />Exterior Finish: 3 Coat Stucco <br />NEW R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 <br />Inside Finish: Gypsum Board <br />Cavity / Frame: R-15 / 2x4 <br />Exterior Finish: 3 Coat Stucco <br />424-P010240138A-000-000-0000000-0000 10/07/2024 21:57 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />1908 N Greenleaf St Unit# <br />24/22/2025