www.hilti.com
<br />Hilti PROFIS Engineering 3.0.95
<br />Input data and results must be checked for conformity with the existing conditions and for plausibility!
<br />PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
<br />5
<br />Company:
<br />Address:
<br />Phone I Fax:
<br />Design:
<br />Fastening point:
<br /> |
<br />Masonry - Jun 19, 2024
<br />Page:
<br />Specifier:
<br />E-Mail:
<br />Date:
<br />5
<br />6/19/2024
<br />4 Shear load (Most utilized anchor 2)
<br />Load Vs [lb]Capacity Vt [lb]Utilization bV = Vs/Vt [%]Status
<br /> Overall strength para and perp, (Dir. x+)1 --8 OK
<br />1Shear utilization may result from parallel and perpendicular shear (see details)
<br />4.1 Overall strength parallel
<br />Vt,Base,||= Value refer to Hilti Technical Data
<br />Vt,||= Vt,Base,|| · fred,E,|| · fred,s,|| · fred,Temp
<br />Vt,||³ Vs,||
<br />Variables
<br />cmin [in.]ccr [in.]smin [in.]scr [in.]Temperature [°F]
<br />4.000 12.000 5.000 11.000 68
<br />Results
<br />Vt,|| [lb]Vt,Base,|| [lb]Vs,|| [lb]fred,E,||fred,S,||fred,Temp Utilization bV,|| [%]
<br />0 1,371 0 0.000 0.000 1.000 0
<br />4.2 Overall strength perpendicular
<br />Vt,Base,^= Value refer to Hilti Technical Data
<br />Vt,^= Vt,Base,^ · fred,E,^ · fred,s,^ · fred,Temp
<br />Vt,^³ Vs,^
<br />Variables
<br />cmin [in.]ccr [in.]smin [in.]scr [in.]Temperature [°F]
<br />4.000 12.000 5.000 11.000 68
<br />Results
<br />Vt,^ [lb]Vt,Base,^ [lb]Vs,^ [lb]fred,E,^fred,S,^fred,Temp Utilization bV,^ [%]
<br />1,261 1,371 90 1.000 0.920 1.000 7
<br />4.3 Shear interaction
<br />bV,|| = Vs,||
<br />Vt,||
<br />bV,^ = Vs,^
<br />Vt,^d Utilization bV [%]Status
<br />0.000 0.071 1.667 8 OK
<br />bV = bd
<br />V,|| + bd
<br />V,^ <= 1.0
<br />P1.22
<br />1700 E St Andrew Pl -
<br />ADA Upgrades12/2/2024
|