Laserfiche WebLink
www.hilti.com <br />Hilti PROFIS Engineering 3.0.95 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />6 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />Masonry - Jun 19, 2024 <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />6 <br />6/19/2024 <br />5 Combined tension and shear loads (Most utilized anchor 2) <br />bP = Ps <br />Pt <br />bV,|| = Vs,|| <br />Vt,|| <br />bV,^ = Vs,^ <br />Vt,^a Utilization bP,V [%]Status <br />0.234 0.000 0.012 1.667 25 OK <br />bP,V = ba <br />P + ba <br />V,|| + ba <br />V,^ <= 1.0 <br />6 Warnings <br />• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, <br /> EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the <br /> anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates <br /> the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The <br /> proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for <br /> agreement with the existing conditions and for plausibility! <br />• Refer to the manufacturer's product literature for cleaning and installation instructions. <br />• For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ <br />• The min. sizes of the bricks, the masonry compressive strength, the type / strength of the mortar and the grout (in case of fully grouted CMU <br /> walls) has to fulfill the requirements given in the relevant ESR-approval or in the PTG. <br />• Only the local load transfer from the anchor(s) to the wall is considered, a further load transfer in the wall is not covered by PROFIS! <br />• Wall is assumed as being perfectly aligned vertically – checking required(!): Noncompliance can lead to significantly different distribution of forces <br /> and higher tension loads than those calculated by PROFIS. Masonry wall must not have any damages (neither visible nor not visible)! While <br /> installation, the positioning of the anchors needs to be maintained as in the design phase i.e. either relative to the brick or relative to the mortar <br /> joints. <br />• The effect of the joints on the compressive stress distribution on the plate / bricks was not taken into consideration. <br />• If no significant resistance is felt over the entire depth of the hole when drilling (e.g. in unfilled butt joints), the anchor should not be set at this <br /> position or the area should be assessed and reinforced. Hilti recommends the anchoring in masonry always with sieve sleeve. Anchors can only <br /> be installed without sieve sleeves in solid bricks when it is guaranteed that it has not any hole or void. <br />• The accessories and installation remarks listed on this report are for the information of the user only. In any case, the instructions for use <br /> provided with the product have to be followed to ensure a proper installation. <br />• The compliance with current standards (e.g. 2018, 2015, 2012, 2009 and 2006 IBC) is the responsibility of the user. <br />• Drilling method (hammer, rotary) to be in accordance with the approval! <br />• Masonry needs to be built in a regular way in accordance with state-of the art guidelines! <br />Fastening meets the design criteria! <br />P1.23 <br />1700 E St Andrew Pl - <br />ADA Upgrades12/2/2024