Laserfiche WebLink
P1.27 <br />Saint Andrew Accessibility Upgrades <br />1700 East Saint Andrew Place, Santa Ana, California 92705 <br />24-7734 <br />6/21/2024 <br />NN <br />FENCE DESIGN: <br />Dimensions of the fence: <br />h = 8ft (measured from ground) <br />s = 7ft <br />B = 8ft <br />B/s = 8ft/7ft = 1.14 < 2 ------> Case C does not need to be considered as per ASCE7-16, <br />Figure 29.3-1 (see next page for snapshot) <br />See next page for wind calculation excel sheet <br />Fence <br />Post <br />Fence <br />Beam <br />8ft 8ft <br />6" <br />7' <br />6" <br />1700 E St Andrew Pl - <br />ADA Upgrades12/2/2024