My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1330 E Seventeenth St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Seventeenth St
>
1330 E Seventeenth St
>
1330 E Seventeenth St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:14 PM
Creation date
6/6/2025 1:18:39 PM
Metadata
Fields
Template:
Plan
Permit Number
20183938
101120775
Full Address
1330 E Seventeenth St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
3.0 Wind Load: <br />Wind Analysis per ASCE 7-16- Wind Tunnel Procedure, Chapter 31 <br />3.1 Wind Load Data: <br /> <br />Basic Wind Speed (Vult) =95 mph (ASCE, Fig. 26.5-1) <br />Exposure Category:C (ASCE, Sec. 26.7.3) <br />Topographic Factor (Kzt) =1 (ASCE, Fig. 26.8-1) <br />Directionality Factor (Kd) =0.85 (ASCE, Table 26.6-1) <br />Exposure Coefficient (Kz) =0.90 (ASCE, Table 26.10-1) <br />Ground Elevation Factor (Ke) =0.99 (ASCE, Table 26.9-1) <br />Velocity Pressure (qz) =0.00256*Kz*Kzt*Kd*Ke*V^2 =17.61 psf (ASCE, Eqn. 26.10-1) <br /> <br />3.2 Roof / Array Zone Map: <br />Figure 3-1. South corner zones – 90-180° wind directions Figure 3-2. North corner zones – 0- 90° wind direction <br /> <br />Roof Zone Map Dimensions per CPP Wind Tunnel Study <br />Height (ft.)LB* (ft.)Velocity Pressure (qz) (psf) <br />20 20.00 17.61 <br />*LB = Characteristic length per wind tunnel study <br /> <br />3.3 Wind Design Equations: <br />FL = qz Aref GCL FL = sum of lift on panel and deflector. <br />FD = qz Aref GCD FD = sum of drag on panel and deflector. <br />FL - D Companion = qz Aref GCL - D Companion <br />FD - L = The accompanying uplift corresponding to maximum <br />drag. <br />Where <br />qz = Velocity Pressure (Ref. Section 3.1, Wind Load) <br />Aref = Module Area (Ref. Section 1.1, General) <br />GCL GCD , GCL-D Companion= Vary and related to wind zone map (Proprietary Wind Tunnel Coefficients) <br />11/04/2024 <br />APPROVED FOR CONSTRUCTION <br />7 <br />PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 <br />(978) 688.4900 - www.panelclaw.com <br />1330 E Seventeenth <br />St4/10/2025
The URL can be used to link to this page
Your browser does not support the video tag.