My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1330 E Seventeenth St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Seventeenth St
>
1330 E Seventeenth St
>
1330 E Seventeenth St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:14 PM
Creation date
6/6/2025 1:18:39 PM
Metadata
Fields
Template:
Plan
Permit Number
20183938
101120775
Full Address
1330 E Seventeenth St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Standard Conditions for Engineering Services on Existing Structures <br />Proposed PV-Panels and Preliminary Design <br />Target T0286 - Santa Ana - Final Report <br />7/19/2024 <br />Sheet 3.1 <br />Prepared by PB <br />Checked by AY <br />• PV solar panels shall be installed on the roof as arrays on a ballasted racking system. A typical ballasted racking <br />system is designed to resist wind uplift and sliding by placing concrete blocks (ballast) as counterweight on the <br />racks. The system does not increase uplift on the building because the ballast should be designed to resist the <br />additional uplift in order to provide the code required factor of safety. <br />• If the PV racking system is mechanically attached to the roof deck, then the uplift and shear forces at each <br />mechanical attachment are not to exceed the capacity noted in this report under the conclusion section. <br />• It is assumed that the panels will be approximately 12 inches above the rooftop at the high end. <br />• It is assumed that the average design weight includes the weight of the panels, racking system and the ballast <br />and all required assemblies. <br />PPE-05184.03 <br />• The analysis is based on the information gathered from the field and/or information provided to Pure Power <br />Engineering and is assumed to be current and accurate. <br />• Unless noted otherwise, the structure and the foundation system are assumed to be in good condition, free of <br />defects, and can achieve theoretical strength. <br />• It is assumed that the structure has been properly maintained and shall be properly maintained during its <br />service. The superstructure and the foundation system are assumed to be designed with proper engineering <br />practice and fabricated, constructed and erected in accordance with the design documents. Pure Power will <br />accept no liability which may arise due to any existing deficiency in design, material, fabrication, erection, <br />construction, etc. or lack of maintenance. <br />• The analysis results are only applicable for the proposed additions and alterations specified in this report. Any <br />deviation of the proposed equipment and placement, etc., will require Pure Power to generate an additional <br />structural analysis. <br />• The analysis does not include the design of the racking system or the ballast it requires. The analysis is <br />performed to verify the capacity of the main structural system. Connections are assumed to have the capacity of <br />the main structural members. <br />• Pure Power assumes that the existing building has NOT been modified or altered from its original design. <br />Building landlord/client shall inform PPE with any kind of modification and/or alteration that may have been <br />done to the existing building during its lifetime. <br />1330 E Seventeenth <br />St4/10/2025
The URL can be used to link to this page
Your browser does not support the video tag.