My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010 & 2012 N Bush Ave, #100 and #101 - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bush St
>
2012 N Bush St Unit# 100
>
2010 & 2012 N Bush Ave, #100 and #101 - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:19 PM
Creation date
6/6/2025 1:18:39 PM
Metadata
Fields
Template:
Plan
Permit Number
101121423
101121424
Full Address
2012 N Bush St Unit# 100
2012 N Bush St Unit# 101
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1' <br />- <br />8 <br />" <br />4'-0" <br />5' <br />- <br />0 <br />" <br />(N) <br />f i n i s h f l o o r1' <br />- <br />8 <br />" <br />4'-0" <br />5' <br />- <br />0 <br />" <br />(N) <br />f i n i s h f l o o r <br />Vaul <br />t <br />e <br />d <br /> <br />c <br />e <br />i <br />l <br />i <br />n <br />g <br />Vaul <br />t <br />e <br />d <br /> <br />c <br />e <br />i <br />l <br />i <br />n <br />g <br />light <br />fixture <br />light <br />fixture <br />light <br />fixture <br />ACB <br />12 <br />10 <br />7' <br />- <br />0 <br />" <br />OWNER/CLIENT <br />PROJECT LOCATION <br />PROJECT TITLE <br />SHEET TITLE <br />DATE <br />AS SHOWN <br />SCALE <br />02 / 24 <br />D R A F T I N G S E R V I C E <br />TE <br />L <br /> <br />: <br /> <br /> <br /> <br />( <br />9 <br />5 <br />1 <br />) <br /> <br />9 <br />9 <br />2 <br />- <br />7 <br />2 <br />3 <br />4 <br />ju <br />a <br />n <br />. <br />g <br />o <br />n <br />z <br />a <br />l <br />e <br />z <br />. <br />1 <br />9 <br />7 <br />1 <br />@ <br />h <br />o <br />t <br />m <br />a <br />i <br />l <br />. <br />c <br />o <br />m <br />SOUTH AND WEST ELEVATION <br />FI <br />N <br />. <br />G <br />. <br />S <br />& <br /> <br />P <br />WA <br />R <br />D <br />F. <br />M <br />. <br />C <br />. <br />FR <br />. <br /> <br />D <br />R <br />. <br /> <br />VL <br />. <br /> <br />S <br />L <br />. <br />KE <br />E <br />P <br /> <br />L <br />A <br />B <br />E <br />L <br /> <br />O <br />N <br /> <br />T <br />H <br />E <br /> <br />W <br />A <br />T <br />E <br />R <br /> <br />H <br />E <br />A <br />T <br />E <br />R <br />3. <br /> <br /> <br /> <br />W <br />A <br />T <br />E <br />R <br /> <br />T <br />O <br /> <br />B <br />E <br /> <br />5 <br />0 <br /> <br />G <br />A <br />L <br />L <br />O <br />N <br />S <br /> <br />M <br />I <br />N <br />. <br />1. <br /> <br /> <br /> <br />A <br />L <br />L <br /> <br />H <br />O <br />R <br />I <br />Z <br />O <br />N <br />T <br />A <br />L <br /> <br />C <br />E <br />I <br />L <br />I <br />N <br />G <br /> <br />D <br />R <br />Y <br />W <br />A <br />L <br />L <br /> <br />A <br />P <br />P <br />L <br />I <br />E <br />D <br /> <br />T <br />O <br /> <br />T <br />R <br />U <br />S <br />S <br />E <br />S <br />2. <br /> <br /> <br /> <br />A <br />L <br />L <br /> <br />E <br />X <br />T <br />E <br />R <br />I <br />O <br />R <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />S <br /> <br />T <br />O <br /> <br />B <br />E <br /> <br />W <br />H <br />I <br />T <br />E <br />. <br /> <br />R <br />E <br />F <br />E <br />R <br /> <br />T <br />O <br /> <br />P <br />L <br />A <br />N <br /> <br />FO <br />R <br /> <br />S <br />I <br />Z <br />E <br /> <br />A <br />N <br />D <br /> <br />E <br />X <br />T <br />E <br />R <br />I <br />O <br />R <br /> <br />E <br />L <br />E <br />V <br />A <br />T <br />I <br />O <br />N <br /> <br />F <br />O <br />R <br /> <br />A <br />L <br />L <br /> <br />B <br />R <br />E <br />A <br />K <br />- <br />U <br />P <br />S <br />SH <br />A <br />L <br />L <br /> <br />B <br />E <br /> <br />5 <br />/ <br />8 <br />" <br /> <br />G <br />Y <br />P <br />S <br />U <br />M <br /> <br />B <br />O <br />A <br />R <br />D <br />SI <br />N <br />G <br />L <br />E <br /> <br />H <br />U <br />N <br />G <br />OP <br />T <br />I <br />O <br />N <br />A <br />L <br />SL <br />I <br />D <br />E <br />R <br /> <br />O <br />R <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br />FI <br />X <br />E <br />D <br /> <br />G <br />L <br />A <br />S <br />S <br />CE <br />I <br />L <br />I <br />N <br />G <br />EL <br />E <br />V <br />A <br />T <br />I <br />O <br />N <br />F. <br />G <br />. <br />S. <br />H <br />. <br />SL <br />. <br />OP <br />T <br />. <br />CL <br />' <br />G <br />. <br />EL <br />E <br />V <br />. <br />W/ <br />SH <br />E <br />L <br />F <br /> <br />& <br /> <br />P <br />O <br />L <br />E <br />FR <br />E <br />N <br />C <br />H <br /> <br />D <br />O <br />O <br />R <br />FL <br />O <br />O <br />R <br /> <br />M <br />A <br />T <br />E <br />R <br />I <br />A <br />L <br /> <br />C <br />H <br />A <br />N <br />G <br />E <br />FI <br />N <br />I <br />S <br />H <br /> <br />G <br />R <br />A <br />D <br />E <br />WI <br />T <br />H <br />WA <br />R <br />D <br />R <br />O <br />B <br />E <br />VI <br />N <br />I <br />L <br /> <br />S <br />L <br />I <br />D <br />E <br />R <br />G& <br />S <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />a <br />l <br /> <br />D <br />e <br />s <br />i <br />g <br />n <br /> <br />a <br />n <br />d <br /> <br />P <br />l <br />a <br />n <br />n <br />i <br />n <br />g <br />JU <br />A <br />N <br /> <br />G <br />O <br />N <br />Z <br />A <br />L <br />E <br />Z <br />12 <br />5 <br />9 <br />4 <br /> <br />M <br />i <br />c <br />h <br />i <br />g <br />a <br />n <br /> <br />S <br />t <br />, <br /> <br />G <br />r <br />a <br />n <br />d <br /> <br />T <br />e <br />r <br />r <br />a <br />c <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />3 <br />1 <br />3 <br />AB <br />B <br />R <br />E <br />V <br />I <br />A <br />T <br />I <br />O <br />N <br />S <br /> <br />TY <br />P <br />I <br />C <br />A <br />L <br /> <br /> <br />N <br />O <br />T <br />E <br />S <br />PL <br />A <br />N <br />S <br /> <br />P <br />R <br />E <br />P <br />A <br />R <br />E <br /> <br />B <br />Y <br />: <br />SHEET <br />Mailing address: <br />JC IMP EXP INC <br />14881 ALDER LN, TUSTIN, <br />CA 92780-6742 <br />6" CLEAR TO GRADE <br />4" CLEAR PAVED SURFACE <br />WEEP SCREED <br />3 1/2" MIN. <br />CONC. <br />FLANGE <br />ATTACHMENT <br />STUDS <br />EARTH <br />WEATHER-RESISTIVE <br />BARRIER REQ. 2 LAYERS <br />OF TYPE "D" PAPER OVER <br />WOOD PANELING. TO LAP <br />THE WEEP SREED <br />ATTACHMENT FLANGE <br />STUCCO <br />ELEVATION KEY NOTES <br />INDICATES ELEVATION NOTES - SEE NUMBERS BELOW : <br />ALL MANUFACTURED EQUIPMENT AND MATERIAL SHALL BE INSTALLLED AS PER <br />MANUFATURES'S SPECIFICATION AND DIMENSIONS VERIFIED WITH INSTALLATION <br />REQUIREMENTS ON SITE. <br />1. ROOF SHINGLE OWENS CORNING CLASS "A", DURATION PRODUCT LINE, OVER 2-LAYERS <br />OF 30# ASTM D 226 TYPE I FELT PAPER MIN. UNDERLAYMENT TO BE INSTALLED IN <br />COMPLIANCE WITH 2022 CRC SECTION R905.2.7 <br />3. WOOD FASCIA PAINTED. <br />2. SMOOTH STUCCO 2-LAYERS OF GRADE "D" PAPER WATER RESISTIVE BARRIER MATCHING <br />EXISTING. SEE STUCCO NOTES. <br />STUCCO NOTES <br />1.STUCCO SYSTEM SHALL COMPLY WITH ICC ESR-1194. <br />2.GENERAL INSTALLATION. THE EXTERIOR COATING MUST BE APPLIED BY HAND-TROWELLING <br />OR MACHINE-SPRAYING, IN ONE COAT OR TWO COATS, TO A MINIMUM 3/8 INCH <br />THICKNESS, UNLESS NOTED OTHERWISE. <br />3.THE LATH MUST BE EMBEDDED IN THE MINIMUM COATING THICKNESS AND THEREFORE <br />CANNOT BE EXPOSED. <br />4.THE FINISH COAT MUST BE APPLIED IN ACCORDANCE WITH MANUFACTURED <br />INSTRUCTIONS. <br />NOTES <br />1.WATER RESISTIVE BARRIER SHALL BE INSTALLED AS REQUIRED IN SECTION R703.2 <br />AND R703.7.3 CRC-2022. <br />2.NEW STUCCO (EXTERIOR PLASTER) SHALL BE IN COMPLIANCE WITH ASTM C 926, <br />ASTM C 1063 AND THE PROVISIONS OF CRC-2022. <br />3.LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION-RESISTANT MATERIAL. <br />EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 1 1 <br />2 INCH-LONG, 11 <br />GAGE NAILS HAVING A 7 <br />16 INCH HEAD, OR 7 <br />8 INCH-LONG, SPACED NOT MORE THAN 6 <br />INCHES AS REQUIRED IN SECTION R 703.7.1 CRC-2022. <br />4.PLASTERING WITH PORTLAND CEMENT PLASTER SHALL BE NOT LESS THAN THREE <br />COATS WHERE APPLIED OVER METAL LATH OR WIRE LATH AND NOT LESS THAN TWO <br />COATS WHERE APPLIED OVER MASONRY, CONCRETE, <br />PRESSURE-PRESERVATIVE-TREATED WOOD OR DECAY-RESISTANT WOOD PER SECTION <br />R317.1 AND SECTION R703.7.2 CRC-2022. <br />4. NEW LIGHT FIXTURE. ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD <br />RUNS OF RUNS OF NOT LESS THAN 1 FOOT CANDLE. PER CRC-2022 SECTION <br />R-303.7 <br />5. ATTIC VENTILATION SHALL COMPLY WITH CRC-2022 SECTION R806.1, R806.2 <br />7. CRAWL ACCESS. MIN 18" X 24". PER CRC-2022 SECTION R 408.4 <br />8. UNDER FLOOR VENTS SHALL COMPLY CRC-2022 SECTION R 408.1 <br />WEEP SCREED DETAIL <br />6. WINDOW SILL HEIGHT 44" MAX ABOVE FINISH FLOOR PER SECTION 310.2.2 <br />CRC-2022 <br />1.BUILDINGS SHALL BE PROVIDED WITH APPROVED ADDRESS <br />IDENTIFICATION. <br />2.THE ADDRESS IDENTIFICATION SHALL BE LEGIBLE AND PLACED IN A <br />POSITION THAT IS VISIBLE FROM THE STREET OR ROAD FRONTING THE <br />PROPERTY. <br />3.ADDRESS IDENTIFICATION CHARACTERS SHALL CONTRAST WITH THEIR <br />BACKGROUND. <br />4.ADDRESS NUMBERS SHALL BE ARABIC NUMBERS OR ALPHABETICAL <br />LETTERS. NUMBERS SHALL NOT BE SPELLED OUT. EACH CHARACTER <br />SHALL BE NOT LESS THAN 4 INCHES (102 MM) IN HEIGHT WITH A <br />STROKE WIDTH OF NOT LESS THAN 0.5 INCH (12.7 MM). <br />5.WHERE REQUIRED BY THE FIRE CODE OFFICIAL, ADDRESS <br />IDENTIFICATION SHALL BE PROVIDED IN ADDITIONAL APPROVED <br />LOCATIONS TO FACILITATE EMERGENCY RESPONSE. <br />6.WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING <br />ADDRESS CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, <br />POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE <br />STRUCTURE. ADDRESS IDENTIFICATION SHALL BE MAINTAINED. <br />ADDRESS IDENTIFICATION <br />PER SECTION 319.1 CRC-2022 <br />DOORBELL per R327.1.4 <br />Doorbell buttons or controls, when installed, shall not exceed 48 <br />inches above exterior floor or landing, measured from the top of the <br />doorbell button assembly. Where doorbell buttons integrated with <br />other features are required to be installed above 48 inches <br />measured from the exterior floor or landing, a standard doorbell <br />button or control shall also be provided at a height not exceeding <br />48 inches above exterior floor or landing, measured from the top of <br />the doorbell button or control. <br />1. ALL NEW SHINGLE SHALL MATCH COLOR, SHAPE AND TEXTURE OF <br />EXISTING IN MAIN HOUSE. <br />2.NEW SIDING, STUCCO SHALL MATCH WITH EXISTING MAIN <br />RESIDENCE COLOR & SIZE <br />3.ALL NEW WINDOW SHALL MATCH STYLE, TRIM AND OPERATING <br />STYLE OF PRIMARY RESIDENCE. <br />FINISHING NOTES <br />PROPOSED ADU's FINISHING NOTES <br />WEST ELEVATION (UNIT #101) <br />1/4" = 1'-0" <br />1' <br />- <br />8 <br />" <br />4'-0" <br />5' <br />- <br />0 <br />" <br />(N) <br />f i n i s h f l o o r <br />(N) <br />UNIT #101 <br />ACCESS <br />3'-0" <br />(N) <br />5' <br />- <br />0 <br />" <br />1' <br />- <br />8 <br />" <br />TEMP <br />light <br />fixture <br />1' <br />- <br />8 <br />" <br />4'-0" <br />5' <br />- <br />0 <br />" <br />(N) <br />f i n i s h f l o o r <br />UNIT #100 <br />ACCESS <br />3'-0" <br />(N) <br />TEMP light <br />fixture <br />light <br />fixture <br />1 2 54 <br />SOUTH ELEVATION (UNIT#100 & UNIT#101) <br />1/4" = 1'-0" <br />3 <br />Mi <br />n <br /> <br />4 <br />' <br />- <br />0 <br />" <br />Elec sub <br />panel adu #1 <br />3'-6" <br />11'-0"11'-0" <br />13'-9"16'-1"16'-0"13'-9" <br />ridge <br />structural <br />beam <br />dorm attic <br />vent <br />dorm attic <br />vent <br />end gable <br />attic vent <br />light <br />fixture <br />f i n i s h g r a d e <br />9' <br />- <br />0 <br />" <br />1' <br />- <br />0 <br />" <br />20 <br />' <br />- <br />0 <br />" <br />10 <br />' <br />- <br />0 <br />" <br />f i n i s h f l o o r <br />d o o r / w i n d o w <br />6' <br />- <br />8 <br />" <br />h e i g h t <br />f i n i s h r i d g e <br />t o p p l a t e <br />f i n i s h c e i l i n g <br />New Roof shingle owens corning class "A", duration <br />product line, over 2-layers of 30# ASTM D 226 type I <br />felt paper min. underlayment to be installed in compliance <br />with 2022-CRC section R905.2.7 <br />ESR-1475 <br />SEE FINISHING NOTE <br />New siding <br />See finishing notes 6"Concrete <br />landing <br />2'-0" <br />f i n i s h g r a d e <br />9' <br />- <br />0 <br />" <br />1' <br />- <br />0 <br />" <br />20 <br />' <br />- <br />0 <br />" <br />10 <br />' <br />- <br />0 <br />" <br />d o o r / w i n d o w <br />6' <br />- <br />8 <br />" <br />h e i g h t <br />f i n i s h r i d g e <br />t o p p l a t e <br />f i n i s h c e i l i n g <br />fascia painted <br />New Roof shingle owens corning class "A", duration <br />product line, over 2-layers of 30# ASTM D 226 type I <br />felt paper min. underlayment to be installed in compliance <br />with 2022-CRC section R905.2.7 <br />ESR-1475 <br />SEE FINISHING NOTE <br />6" <br />12 <br />10 <br />Concrete <br />landing <br />Concrete <br />landing <br />3'-0"3'-0" <br />2'-0" <br />2'-0" <br />2'-0" <br />3'-0" <br />(N) <br />3' <br />- <br />8 <br />" <br />3' <br />- <br />0 <br />" <br />5' <br />- <br />0 <br />" <br />1' <br />- <br />8 <br />" <br />Mi <br />n <br /> <br />4 <br />' <br />- <br />0 <br />" <br />Elec sub <br />panel adu #2 <br />3'-0" <br />(N) <br />3' <br />- <br />8 <br />" <br />3' <br />- <br />0 <br />" <br />fascia painted 12 <br />5 <br />3'-0" <br />light <br />fixture <br />1'-6" <br />FRONT <br />PORCH <br />Concrete <br />landing <br />3'-0" <br />Architectural <br />detail see <br />Main house <br />& finishing <br />details <br />COVER <br />PATIO <br />fascia painted <br />wo <br />o <br />d <br /> <br />p <br />o <br />s <br />t <br />wo <br />o <br />d <br /> <br />p <br />o <br />s <br />t <br />kne <br />e <br /> <br />b <br />r <br />a <br />c <br />e <br />kne <br />e <br /> <br />b <br />r <br />a <br />c <br />e <br />kne <br />e <br /> <br />b <br />r <br />a <br />c <br />e <br />wo <br />o <br />d <br /> <br />p <br />o <br />s <br />t <br />kne <br />e <br /> <br />b <br />r <br />a <br />c <br />e <br />wo <br />o <br />d <br /> <br />p <br />o <br />s <br />t <br />kne <br />e <br /> <br />b <br />r <br />a <br />c <br />e <br />wo <br />o <br />d <br /> <br />p <br />o <br />s <br />t <br />kne <br />e <br /> <br />b <br />r <br />a <br />c <br />e <br />PROPOSED (2) TWO NEW <br />ADU's. <br />1. PROPOSED NEW GAF AUTUMN BROWN COMPOSITION SHINGLE. ASTM D3161 & <br />ASTM 7158. FIRE RATING, UL CLASS A, ANSI/UL 790. <br />2.PROPOSED NEW EXTERIOR FIBER-CEMENT (MEDIUN DENSITY) LAP SIDING. HARDIE <br />TRIM HZ10 0.75 IN. X 3.5 IN X 12 FT. PRIMER RUSTIC GRAIN FIBER CEMENT TRIM <br />BOARD. GRAY COLOR PAINTED. <br />3.PROPOSED WHITE ALUMINUM SINGLE HUNG WINDOWS. <br />4.PROPOSED WHITE WINDOWS HEADER MOLDING, SILL & 2 SIDE TRIMS. <br />WEATHER-RESISTANT MATERIAL. <br />(SHOULD BE SIMILAR BUT NOT EXACT MATCH TO EXISTING MFD) <br />fascia painted12 <br />5 <br />1'-6" <br />fascia painted <br />2'-0"2'-0" <br />2010 AND 2012 N BUSH <br />AVE #100 AND #101, SANTA <br />ANA, CA 92706-2818 <br />01-A-8 <br />REG <br />ISTERED PROF E S S IONAL ENGI <br />NE <br />ER <br />STATE OF CAL IFORNIA <br />NO. C-31397 <br />EXP. 12/31/2024 <br />C I V I L <br />LEO A . A GUILERA <br />2010 & 2012 N Bush Ave, <br />#100 and #1012/21/2025
The URL can be used to link to this page
Your browser does not support the video tag.